• Title/Summary/Keyword: Tissue remodeling

Search Result 234, Processing Time 0.031 seconds

Influence of implant mucosal thickness on early bone loss: a systematic review with meta-analysis

  • Di Gianfilippo, Riccardo;Valente, Nicola Alberto;Toti, Paolo;Wang, Hom-Lay;Barone, Antonio
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.4
    • /
    • pp.209-225
    • /
    • 2020
  • Purpose: Marginal bone loss (MBL) is an important clinical issue in implant therapy. One feature that has been cited as a contributing factor to this bone loss is peri-implant mucosal thickness. Therefore, in this report, we conducted a systematic review of the literature comparing bone remodeling around implants placed in areas with thick (≥2-mm) vs. thin (<2-mm) mucosa. Methods: A PICO question was defined. Manual and electronic searches were performed of the MEDLINE/PubMed and Cochrane Oral Health Group databases. The inclusion criteria were prospective studies that documented soft tissue thickness with direct intraoperative measurements and that included at least 1 year of follow-up. When possible, a meta-analysis was performed for both the overall and subgroup analyses. Results: Thirteen papers fulfilled the inclusion criteria. A meta-analysis of 7 randomized clinical trials was conducted. Significantly less bone loss was found around implants with thick mucosa than around those with thin mucosa (difference, -0.53 mm; P<0.0001). Subgroups were analyzed regarding the apico-coronal positioning, the use of platform-matched vs. platform-switched (PS) connections, and the use of cement-retained vs. screw-retained prostheses. In these analyses, thick mucosa was found to be associated with significantly less MBL than thin mucosa (P<0.0001). Among non-matching (PS) connections and screw-retained prostheses, bone levels were not affected by mucosal thickness. Conclusions: Soft tissue thickness was found to be correlated with MBL except in cases of PS connections used on implants with thin tissues and screw-retained prostheses. Mucosal thickness did not affect implant survival or the occurrence of biological or aesthetic complications.

Does the prosthesis weight matter? 3D finite element analysis of a fixed implant-supported prosthesis at different weights and implant numbers

  • Tribst, Joao Paulo Mendes;Dal Piva, Amanda Maria de Oliveira;Borges, Alexandre Luiz Souto;Rodrigues, Vinicius Aneas;Bottino, Marco Antonio;Kleverlaan, Cornelis Johannes
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.2
    • /
    • pp.67-74
    • /
    • 2020
  • PURPOSE. This study evaluated the influence of prosthesis weight and number of implants on the bone tissue microstrain. MATERIALS AND METHODS. Fifteen (15) fixed full-arch implant-supported prosthesis designs were created using a modeling software with different numbers of implants (4, 6, or 8) and prosthesis weights (10, 15, 20, 40, or 60 g). Each solid was imported to the computer aided engineering software and tetrahedral elements formed the mesh. The material properties were assigned to each solid with isotropic and homogeneous behavior. The friction coefficient was set as 0.3 between all the metallic interfaces, 0.65 for the cortical bone-implant interface, and 0.77 for the cancellous bone-implant interface. The standard earth gravity was defined along the Z-axis and the bone was fixed. The resulting equivalent strain was assumed as failure criteria. RESULTS. The prosthesis weight was related to the bone strain. The more implants installed, the less the amount of strain generated in the bone. The most critical situation was the use of a 60 g prosthesis supported by 4 implants with the largest calculated magnitude of 39.9 mm/mm, thereby suggesting that there was no group able to induce bone remodeling simply due to the prosthesis weight. CONCLUSION. Heavier prostheses under the effect of gravity force are related to more strain being generated around the implants. Installing more implants to support the prosthesis enables attenuating the effects observed in the bone. The simulated prostheses were not able to generate harmful values of peri-implant bone strain.

MMP-2 and MMP-9 are Differentially Involved in Molar Growth

  • Kim, Min-Seok;Kang, Jee-Hae;Kim, Dong-Hoo;Yoo, Hong-Il;Jung, Na-Ri;Yang, So-Young;Lee, Eun-Ju;Kim, Sun-Hun
    • International Journal of Oral Biology
    • /
    • v.36 no.4
    • /
    • pp.195-201
    • /
    • 2011
  • Matrix metalloproteinases (MMPs) have been implicated in tissue development and re-modeling. Dynamic morphological changes of tooth germs reflect involvement of these enzymes during odontogenesis. The present study was performed to investigate expression and localization of MMP-2 and MMP-9, which have been known to have type IV collagenase activities, in rat tooth germs at different developmental stages. MMP-2 expression was increased gradually in the tooth germs from cap to crown staged germs at both transcription and translation levels. The localization of this molecule was detected in secretory ameloblasts and preameloblasts. The strong immunoreactivities were occasionally seen along the basement membrane between ameloblasts (or preameloblasts) and odontoblasts (preodontoblasts). However, weak reactivity was detected in odontoblasts and reduced enamel epithelium. The level of MMP-9 expression in the tooth germs was higher in cap stage than in crown staged germs at both transcription and translation levels. They were strongly expressed in both ameloblasts and odontoblasts. Even though reduced enamel epithelium after enamel formation and inner enamel epithelium at the cap stage exhibited weak reactivity, strong reactivity was detected in dental follicles and perifollicular tissues surrounding cap staged germs. These results suggested that MMP-2 may involve degradation of the basement membrane during hard tissue formation, whereas MMP-9 might be involved in remodeling of follicular tissues.

Comparison of cone-beam computed tomography and ultrasonography on experimental bone lesion (실험적 골 병소에 대한 콘빔형전산화단층영상과 초음파영상의 비교)

  • Kim, Min-Sung;Park, Cheol-Woo;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.40 no.3
    • /
    • pp.137-142
    • /
    • 2010
  • Purpose : This study was performed to evaluate the diagnostic ability of ultrasonography in detection of bone defects and new bone formation. Materials and Methods : Experimental bony defects were prepared on the parietal bone samples acquired from 3.5 kg New Zealand male rabbits. The defects were evaluated using ultrasonography and CBCT, and examined histologically at interval of 1, 3, 6, and 8 weeks. Results : Ultrasonograph demonstrated hyperechogenicity in the defect area at 3 weeks and broadened hyperechogenicity from the margin of bone defect at 6 and 8 weeks due to new bone formation. On the CBCT images, new bone formation was first observed at 3 weeks around the margin of the defect, and showed gradually increase at 6 and 8 weeks. Histologic findings revealed existence of the fibroblasts and fibrous connective tissue with abundant capillary vessels only at 1 week, but osteoid tissue and newly formed trabecular bone at 3 weeks. Bone remodeling in the defect area was observed at 6 weeks and increased calcification and dense trabecular bone formation was observed at 8 weeks. Conclusions : Ultrasonograph proved to be a very useful diagnostic tool in detecting the bony defect and new bone formation. Additionally, ultrasonography provided valuable information regarding the blood supply around the defect area.

Morphological differences between Water deer and Sika deer ovaries during estrus and pregnancy

  • Ji-Hye Lee;Yong-Su Park;Min-Gee Oh;Sang-Hwan Kim
    • Journal of Animal Reproduction and Biotechnology
    • /
    • v.38 no.2
    • /
    • pp.62-69
    • /
    • 2023
  • Background: Research on the reproductive physiology of Water and Sika deer, an endemic in Korea, still needs to be completed. This study analyzed the ovarian development and morphological characteristics of wild Water deer and Sika deer. Methods: Water deer and Sika deer ovaries were collected from the Korean Peninsula and Russia-Korean Peninsula border during the estrus and pregnancy seasons, respectively. And, morphological and physiological analysis and immunohistochemistry were conducted to confirm the detection of Ca2+ and assess the morphological changes in the ovaries. Results: The results of morphological analysis of ovaries during pregnancy and estrus, the development of the corpus luteum and follicles of Water deer showed similar patterns to other mammals. In contrast, the corpus luteum of Sika deer differed in tissue morphology and composition from Water deer. Ca2+ related to tissue metabolism was detected in the theca cells zone of Water deer on the estrus and was highly detected in the luteum cells zone during pregnancy. The hormone receptor protein expression patterns were generally higher in the ovaries of Water deer on the estrus and the pregnancy than in Sika deer. The expression of LH receptor was relatively low in the lutein cell zone, unlikely that of Water deer. The expression of VEGF was also different from Water deer, and the response in Sika deer was relatively very low compared to Water deer in expressing all proteins-related development. Conclusions: Therefore, the results of the study were shown that the composition of the corpus luteum of Sika deer is not clear compared to Water deer, and there are many differences in the functional and morphological formation of the corpus luteum.

DISTRIBUTION IN FIBRONECTIN OF THE RABBIT TEMPOROMANDIBULAR JOINT TISSUES FOLLOWING SURGICAL INDUCTION OF ANTERIOR DISK DISPLACEMENT : IMMUNOHISTOCHEMICAL STUDY (악관절원판의 인위적 전방변위술시행후 악관절구성조직에서 Fibronectin의 분포변화)

  • Kim, Uk-Kyu;Chung, In-Kyo;Park, Bong-Soo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.25 no.4
    • /
    • pp.337-349
    • /
    • 1999
  • The extracellular matrix(ECM) is a complex network of different combination of collagens, glycosaminoglycans, laminin, fibronectin, and many other glycoproteins including proteolytic enzymes. The composition and organization of the ECM contributes to the uniques physical or biomechanical properties of a tissue. Fibronectins(FN) are dimeric glycoproteins located on cell surfaces, in the matrix of connective tissue, and in blood. Fibronectins mediate cell attachment to collagen substratum and have been implicated in a variety of important biological processes, including embryogenesis and cell differentiation. The purpose of this study was to determine the effects of surgical induction of anterior disk displacement(ADD) on distribution of fibronectin in the rabbit temporomandibular joint(TMJ) tissues included the articular cartilage, disc, retrodiscal tissue, articular eminence using an immunohistochemical technique. The left TMJ was exposed surgically, and all discal attachments were severed except for the posterior attachment. The disk was then repositioned anteriorly and sutured to the zygomatic arch. The right TMJ served as a shamoperated control. Normal joints were used as a nonoperated control. Fourty-five rabbits were used for experiments in total. For fibronectin immunohistochemical study, eighteen rabbits (one normal group and 5 experimental groups, each group consists of 3 rabbits) were used. The experimental rabbits were sacrified after operation period of 2, 3, 4, 6 and 8 weeks on fibronectin. The obtained results were as follows ; 1. Fibronectin immunoreaction on all TMJ tissues(mandibular condyle, articular disc, retrodiscal tissue, articular eminence) in the normal rabbit was observed. Especially the reverse cell layer and proliferation zone of articular cartilage of condyle show strong positive reaction. 2. Depletion of fibronectin in the all TMJ tissues except hypertrophic zone of articular cartilage occurred at 2 weeks following induction of ADD. 3. The restoration of immunoreaction at 4 weeks was observed and a progressive increasing reaction at 6 weeks, 8 weeks also was found. Our study generally showed degenerative changes in TMJ tissues after ADD although TMJ tissues adapted or degenerated to abnormal loads and stress distribution according to the remodeling capacity of TMJ tissues.

  • PDF

THE EFFECT OF DENIAL ORTHOPEDIC FORCE TO IMPLANTS ON BONE TISSUE BEFORE COMPLETE OSSEOINTEGRATION (골유착 이전에 악정형력이 임프란트 주위조직에 미치는 영향)

  • Kim, Young-Ho;Lee, Cheol Won
    • The korean journal of orthodontics
    • /
    • v.28 no.3 s.68
    • /
    • pp.453-459
    • /
    • 1998
  • The dental implants for edentulous Patients have been used for more than 20 years. After the introduction of osseointegration by $Br{\aa}nemark$, the commercially pure titanium implants were accepted by most practitioners. Recently dental implants are used for orthodontic anchorages as well as prosthetic abutment. Many researchers have reported implants as a good orthodontic anchorage through basic research and clinical evaluation. But previous researches were done after the healing time for osseointegration of inserted implants. If dental implants are to be used for prosthetic abutment the healing time for osseointegration is necessary, but orthodontic forces to implants are different from bite force regarding its amount of force, duration and direction. The authors evaluated the effect of orthopedic force to implants on bone tissue before osseointegration. 48 implants were placed at 12 rabbits. 2 implants into left side and 2 implants into right side were inserted along the long axis of femur respectively 2 weeks (2 weeks group), 4 weeks (4 weeks group) and 6 weeks (6 weeks group) after implants placement, 300g force had been applied to the implants at left side femur by Ni-Ti close coil spring for 4 weeks (experimental group) and no force applied to implants at right side femur (control group). After the force application for 4weeks, rabbits were sacrificed and microscopic evaluation was done by hematoxylin-eosin stain and Masson trichrome stain. The result3 were followed. 1. All implants in experimental group remained rigid after the force application for 4 weeks. 2. More fibrous tissue between bone and implants were noticed at 2 weeks experimental group than 2 weeks control group 3. More bone remodeling was noticed at 4weeks group than 2 weeks group and it was difficult to find out fibrous tissue between bone and implants at both experimental and control group of 4 weeks group. 4. It was hard to distinguish experimental group from control group at 6 weeks group. Therefore if initial stability can be obtained on implant insertion, it can be possible to use implants as a orthodontic anchorage before the healing time for osseointegration.

  • PDF

Polymorphism, Genetic Effect and Association with Egg Production Traits of Chicken Matrix Metalloproteinases 9 Promoter

  • Zhu, Guiyu;Jiang, Yunliang
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.27 no.11
    • /
    • pp.1526-1531
    • /
    • 2014
  • Matrix metalloproteinases (MMP) are key enzymes involved in cell and tissue remodeling during ovarian follicle development and ovulation. The control of MMP9 transcription in ovarian follicles occurs through a core promoter region (-2,400 to -1,700 bp). The aim of this study was to screen genetic variations in the core promoter region and examine MMP9 transcription regulation and reproduction performance. A single cytosine deletion/insertion polymorphism was found at -1954 $C^+/C^-$. Genetic association analysis indicated significant correlation between the deletion genotype ($C^-$) with total egg numbers at 28 weeks (p = 0.031). Furthermore, luciferase-reporter assay showed the deletion genotype ($C^-$) had significantly lower promoter activity than the insertion genotype ($C^+$) in primary granulosa cells (p<0.01). Therefore, the identified polymorphism could be used for marker-assisted selection to improve chicken laying performance.

Roles of growth factors, calcitonic polypeptides and neuropeptides in bone metabolism, osteoporosis and rheumatis arthritis

  • Lee, Tae-Kyun;Kim, June-ki;Kim, Kap-Sung;Chang, Jun-Hyuk;Jeong, Ji-cheon;Nam, Kyung-Soo;Kim, Cheorl-Ho
    • The Journal of Dong Guk Oriental Medicine
    • /
    • v.9
    • /
    • pp.1-23
    • /
    • 2000
  • Osteoporosis is a common disorder characterized by reduced bone mineral density, deterioration of the microarchitecture of bone tissue and increased risk of fracture. The aim of treatment of osteoporosis is to maintain and, ideally, to restore bone strength safely. In recent years the role of polypeptide growth factors in bone metabolism has begun to appear. It has been proposed that alterations in the expression or production of growth factor can modulate the proliferation and activity of bone forming cells. Thus, the role of structurally diverse peptides for the management and diagnosis of osteoporosis has attracted the attention of many investigators. This paper reviews numerous findings concerning the use of polypeptides, hormones, and growth factors, for the management of osteoporosis. Many of the compounds mentioned here are experimental prototypes of new therapeutic classes. Though it is unlikely that some of the compounds may ever be used clinically, development of safe and efficacious agents in each class will define the future course of therapy for osteoporosis.

  • PDF

EFFECTS OF HYPOXIA ON THE FORMATION OF OSTEOCLAST (저산소증이 파골세포 분화에 미치는 영향에 관한 연구)

  • Sim, Hye-Young;Jung, Da-Un;Chae, Chang-Hoon;Lee, Young;Jang, Eun-Sik;Choi, Mee-Ra;Hong, Soon-Min;Park, Jun-Woo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.1
    • /
    • pp.23-26
    • /
    • 2010
  • The vascular changes in periodontal tissues cause local hypoxia which seems to affect the periodontal tissue cells. Abrupt changes in oxygen availability within the periodontium have been suggested to have a regulatory role in alveolar bone remodeling during tooth movement, bone growth or fracture healing. The purpose of this study was to study the effects of hypoxia on formation of osteoclast responsible for bone resorption, in vitro. Primary mouse bone marrow cells were cultured in normoxic (20% $O_2$) and hypoxic (1% $O_2$) conditions and assayed for cellular proliferation. The results obtained were as follows : 1. Reducing oxygen tension increased the formation of multinucleated osteoclasts. 2. Hypoxic stimulus increased the size of mature osteoclasts.