Feasibility Test of Flat-Type Faraday Cup for Ultrahigh-Dose-Rate Transmission Proton Beam Therapy

  • Sang-il Pak;Sungkoo Cho;Seohyeon An;Seonghoon Jeong;Dongho Shin;Youngkyung Lim;Jong Hwi Jeong;Haksoo Kim;Se Byeong Lee
    • 한국의학물리학회지:의학물리
    • /
    • 제33권4호
    • /
    • pp.108-113
    • /
    • 2022
  • Purpose: Proton therapy has been used for optimal cancer treatment by adapting its Bragg-peak characteristics. Recently, a tissue-sparing effect was introduced in ultrahigh-dose-rate (FLASH) radiation; the high-energy transmission proton beam is considered in proton FLASH therapy. In measuring high-energy/ultrahigh-dose-rate proton beam, Faraday Cup is considered as a dose-rate-independent measurement device, which has been widely studied. In this paper, the feasibility of the simply designed Faraday Cup (Poor Man's Faraday Cup, PMFC) for transmission proton FLASH therapy is investigated. Methods: In general, Faraday cups were used in the measurement of charged particles. The simply designed Faraday Cup and Advanced Markus ion chamber were used for high-energy proton beam measurement in this study. Results: The PMFC shows an acceptable performance, including accuracy in general dosimetric tests. The PMFC has a linear response to the dose and dose rate. The proton fluence was decreased with the increase of depth until the depth was near the proton beam range. Regarding secondary particles backscatter from PMFC, the effect was negligible. Conclusions: In this study, we performed an experiment to investigate the feasibility of PMFC for measuring high-energy proton beams. The PMFC can be used as a beam stopper and secondary monitoring system for transmission proton beam FLASH therapy.

선형가속기 10 MV 광자선에서 산란판(Beam Spoiler) 사용 시 표면선량 변화 (The Variation of Surface Dose by Beam Spoiler in 10 MV Photon Beam from Linear Accelerator)

  • 배성철;김준호;이철수
    • 대한방사선치료학회지
    • /
    • 제18권1호
    • /
    • pp.21-28
    • /
    • 2006
  • 목 적: 10 MV X-선의 선형가속기를 이용하여 두경부종양 및 임파선 전이 환자를 치료할 시 피부표면 종양에 균일한 선량을 부여하기 위하여 조직 등가물질로 산란판을 제작하였으며 팬톰을 이용한 피부선량을 측정하여 그 효과를 평가하였다. 대상 및 방법: 조직 등가 물질인 lucite로 산란판을 제작하여 가속기의 콜리메이터와 피부사이에 부착하였으며 조사면적의 크기($5{\times}5{\sim}30{\times}30cm^2$)와 산란판 두께 및 피부와 산란판 간의 거리에 따른 피부 및 체표 0.4 cm에서의 선량 변화를 측정하였다. 또한 자체 제작한 산란 판의 체표 선량 증강 효과를 평가하기위해 볼루스를 이용한 체표 선량을 측정하여 그 효과를 비교하였다. 결 과: 10 MV X-선 선형가속기와 피부 사이에 산란판을 설치하여 피부선량이 증가 되었으며 산란판의 위치에 따라 피부선량이 변화되었고, 0.4 cm 깊이의 선량과 최대선량지점이 피부표면쪽으로 이동하였다. 산란판이 일정할 경우 조사면적이 커질수록 표면선량이 증가하고 최대 선량점은 피부표면 방향으로 이동하였다. 또한 산란판의 두께가 두꺼울수록 표면선량이 증가하고 최대 선량점은 피부표면 방향으로 이동하였다. 결 론: 10 MV X-선을 이용하여 두경부 종양 및 임파선 전이 암을 치료할 경우 산란판을 이용하여 이차산란 전자를 피부표면 앞에서 발생시킴으로써 표면근접부의 선량을 증가시켜 종양부위에 균일한 선량을 조사할 수 있었다. 본 연구에서는 조사면적에 따라 적정 산란판 조건을 찾아 임상에서 유용하게 사용하고자 하였으며, 1.2 cm, 1.8 cm 두께의 산란판을 피부로부터 7 cm에 위치 시켰을때 $10{\times}10cm^2$ 조사면적의 표면선량이 각각 60%, 64%로 측정되었고, 0.4 cm 깊이의 선량이 94%, 94%로 가장 이상적으로 관찰되었다.

  • PDF

Co-60에 의한 전신조사시 선량분포 (Dose Distribution of Co-60 Photon Beam in Total Body Irradiation)

  • Kang, Wee-Saing
    • 한국의학물리학회지:의학물리
    • /
    • 제2권2호
    • /
    • pp.109-120
    • /
    • 1991
  • 골수이식을 받게 될 환자의 이상 골수를 완전히 죽이기 위해 MV 정도의 선질의 광자선에 의한 전신방사선요법이 시행되고 있다. 국소방사선요법에 이용되고 있는 방사선치료장치에 의한 일상적인 방법으로 환자의 전선에 걸쳐 방사선을 조사하기에는 조사면의 크기가 훨씬 미치지 못한다. 그래서 환자의 전선에 걸쳐 방사선을 조사할 수 있는 방법이 개발되어야 한다. 방사선 전신조사를 위한 여건이 병원에 따라 다를 것이기 때문에 병원에 따라 독특한 방법이 개발될 수 있다. 서울대학교병원에서는 코발트치료기 만이 두부를 기울일 수 있어서 전신조사에 이용될 수 있다. 코발트치료기의 두부를 밖으로 90$^{\circ}$ 기울일 때 선축은 수평이고 또한 맞은편 벽과 직각이 된다. 이 때 선원에서 맞은편 벽가지 거리는 319cm 이였다. 벽에서 환자의 중앙시상면까지 간격을 40cm라고 가정할 때, 중앙시상면에서 명목상 최대 조사면 크기가 122cm$\times$122em 이였고, 조사선량 분포를 측정한 결과로는 130cm$\times$129cm 이였으며 상하방향에서는 대칭이 아니였다. 환자가 쭈그리고 앉은 자세를 취한다면 조사면의 크기는 전신조사를 시행할 수 있을 정도로 충분히 크다. 환자 좌우폭의 평균을 30cm 라고 가정하고, 중앙시상면에서 선원쪽 15cm 위치에 기준표면 (SSD는 264cm, 명목상 조사면 크기 115.5cm$\times$155.5cm)을 두고 단면의 크기가 25cm$\times$25cm이고 두께가 30cm 인 폴리스티렌 팬톰에서 평판형 전리함으로 PDD를 측정하였다. 최대선량점의 깊이는 0.3cm 이였고 표면선량율은 82%, 50% 깊이는 16.9cm였다. 대향조사시 선축상 선량분포는 중점의 선량에서 10%이내로 일치하였다. SCD를 279cm. 최대 조사면, 기준깊이 15cm 에 대한 TPR 을 폴리스티렌 팬톰에서 깊이 10cm 에서 20cm 에 걸쳐 측정하였다 . 측정범위에서 TPR 은 직선성을 보였다. 인체팬톰의 최대 전단면(coronal plane) 에 있는 각 구멍에 TLD 조각을 넣고, 코발트 선원에서 팬톰의 시상면까지 거리를 279cm 되게 하고 선축은 팬톰의 27번 절편과 28번 절편의 접변과 최대 전단면의 교차선과 일치시켜 양방향에서 15분씩 조사하여 전단면에서 선량을 측정하였다. 팬톰내 선축상 중앙점의 선량을 기준으로 다른 부위의 선량을 비교하였다. 두경부와 복부, 폐의 하반에서 선량의 차이는 $\pm$ 10% 이내였고, 폐의 상반과 어깨와 골반 부위에서 선량은 10%이상 저선량을 보였다. 특히 어깨부위에는 30%이상 저선량을 보였다. 이로부터 서울대병원과 유사한 조건에서 코발트로 전신조사하는 경우에는 폐나 두경부에 대응하는 조직보상체를 이용하기보다는 어깨부위에 선량을 추가하는 것이 바람직할 것이라고 생각한다.

  • PDF

Mevatron KD 8067 선형가속기의 23 MV 광자선의 특성 (Characteristics of 23 MV Photon Beam from a Mevatron KD 8067 Dual Energy Linear Accelerator)

  • 김옥배;최태진;김영훈
    • Radiation Oncology Journal
    • /
    • 제8권1호
    • /
    • pp.115-124
    • /
    • 1990
  • 고 에너지 23MV광자선의 특성 중 임상적용에 중요한 심부선량 백분율, 조직-최대선량비 (TMR), 산란-최대선량비 (SMR), 표면선량 및 출력선량 보정계수등의 변수가 이온전리 (IC-10)함 및 평행 평판전리 (PS-033)함에 의해 측정 조사되었다. 명목상의 23 MV X-선에 대한 가속에너지는 $18.5\pm0.5$ MV로 측정되었다. Mevatron KD 8067의 23 MV X-선의 중심선속의 반가층이 기하학적인 좁은 선속으로 측정되었으며 반가층의 두께는 $24.5\;g/cm^2$이었다. 조직-최대선량비는 심부선량백분율표에서 구해졌으며, 실측치와 비교한 결과 각 조사면의 크기와 깊이에서 약간의 차이를 보였으나 평균 $0.7\pm0.5$의 오차를 나타내고 있어 계산에 의한 TMR 값과 잘 일치함을 보였다. 조사면 $0\times0\;cm^2$의 TMR 값은 zero 조사면의 유효감약계수에 의한 값과, 각 조사면의 조직-최대 선량비로 부터 비선형최소자승법에 의해 구해진 유효선흡수계수 및 반가층 측정에 의한 유효선흡수 계수에 의한 값들로 비교되었으며, $\mu=0.0283{\pm}0,0002cm^{-1}$을 보였고, 세 방법 모두 오차범위내에서 잘 일치됨을 보였다. 한편, 불규칙 조사면의 선량계산에 이용될 SMR은 조사면의 반경 50cm까지 계산되어 대형 조사 면에서도 선량율 산출이 이루어지도록 하였다. Mevatron KD 8067의 23 MV X-선의 조직 표면선량은 SSD 100 cm, 1$10\times10\;cm^2$의 조사면에서 최대조직선량율의 $9.6\%,\;25\times25\;cm^2$에서는 $25.4\%$를 보였다.

  • PDF

저용량 독시싸이클린 투여가 만성 치주염에 미치는 임상적 미생물학적 효과 (Clinical and microbiologic effects of the subantimicrobial dose of doxycycline on the chronic periodontitis)

  • 김상준;엄흥식;장범석;이재관
    • Journal of Periodontal and Implant Science
    • /
    • 제39권1호
    • /
    • pp.37-44
    • /
    • 2009
  • Purpose: Tetracycline and its chemically modified non-antibacterial analogues can inhibit certain host-derived tissue destructive collagenases such as matrix metalloproteinases. The purpose of this study was to evaluate clinical and microbiologic effects of the subantimicrobial dose of doxycycline(SDD) in conjunction with scaling and root planing. Materials and methods: A total of 30 patients with chronic periodontitis who were going to receive scaling and root planing were randomly allocated to receive either a doxycycline hyclate for 3 months or nothing. Clinical probing depth, clinical attachment level, gingival recession, and bleeding on probing were measured by one periodontist. After a periodontal examination, microbial samples were collected using sterile paper points. The effect of SDD in conjunction with scaling and root planing on alterations of the periodontal pathogens (Aggregatibacter actinomycetemcomitans, Tannerella forsythia, Porphyromonas gingivalis) were also assessed using l6S rRNA polymerase chain reaction. Results: During the treatment period, clinical parameters for both treatment group and control group were improved. After 3 months, reductions in probing depth and gains in clinical attachment level were significantly greater for the SDD group than control group. Microbial analysis showed that there was no alteration of the periodontal pathogens and no difference between the groups. Conclusion: This study suggested that the subantimicrobial dose of doxycycline as an adjunct therapy with scaling and root planing might be effective and safe in the management of chronic periodontitis.

ML-6M선형 가속기에서의 BEAM 특성에 대한 고찰

  • 문언철;윤병운;오양환
    • 대한방사선치료학회지
    • /
    • 제5권1호
    • /
    • pp.115-119
    • /
    • 1992
  • The beam characteristics and dosimetric measurements of the 6MV X-ray and 6MeV electron beam from a ML-6M linear accelerator are examined. The Percent Depth Dose(PDD) table and the tissue Maximum Ratio(TMR) table are taken from measurement as a function of the field size and the depth. The calculated TMR table from PDD table is compared with those from measurement. Other beam characteristics such as output factor, beam profile(including flatness, symmetry and penumbra), wedge, and the variation of Dmax are presented. All of these dosimetric measurements sufficiently characterized the beam to permit safe clinical use.

  • PDF

Mevatron KD 선형 가속기에서의 10MV X-선 특성 (Charateristics of 10MV X-ray Beam from a Mevatron KD Linear Accelerator)

  • 이병용;이명자
    • Radiation Oncology Journal
    • /
    • 제6권1호
    • /
    • pp.101-108
    • /
    • 1988
  • The beam characteristics and dosimetric measurements of the 10MV X-ray beam from a Mevatron KD linear accelerator are examined. The Percent Depth Dose (POD) table and the Tissue Maximum Ratio (TMR) table are taken from measurement as a function of the field size and the depth. The calculated TMR table from PDD table is compared with those from measurement. Other beam characteristics such as output factor, beam profile (including flatness, symmetry and penumbra), wedge, and the variation of Dmax are presented.

  • PDF

치료 방사선 선속(Flux)에 포함된 산란전자의 분포와 에너지 측정 (The Measurements of Energy and Distribution of Scattered Electrons in Therapeutic X-Ray Beam)

  • Vahc, Young-Woo;Park, Kyung-Ran;Ohyun Kwon;Lee, Yong-Ha;Kim, Tae-Hong;Kim, Sookil
    • 한국의학물리학회지:의학물리
    • /
    • 제13권1호
    • /
    • pp.1-8
    • /
    • 2002
  • 치료방사선 선형가속기에서 출력되는 광자선의 선속 (flux)에는 gantry head로부터 발생되는 오염전자를 포함하고 있으며, 오염전자의 발생은 주로 gantry head의 부속장비 또는 방사선 치료를 위해 gantry head 밑에 설치되는 부속장치 등에서 광자선과 매질의 전자쌍생성, 또는 컴프톤 산란전자 등의 물리적 현상으로 발생된다. 오염전자는 표면영역의 수cm 깊이의 선량 분포에 영향을 주고 있으며, 이것은 방사선 치료 시 skin-sparing 효과를 감소시키는 등 임상적인 측면에 영향을 주고 있다. 그러므로 선형가속기에서 발생되는 오염전자의 특성을 이해 할 필요가 있다. 본 연구는 선형가속기 (Clinac 1800, Varian )에서 출력되는 15MV 광자 선속에서 조사야의 크기가 0.0$\times$10.0 to 30.0$\times$30.0 $\textrm{cm}^2$에서 30.0$\times$30.0 $\textrm{cm}^2$ 대해 구리판(Cu)의 부분적 오염전자 제거 능력과, 조사야의 부분 차폐 방법을 이용하여 물팬톰 내의 선량분포의 변화를 측정하므로써 오염전자의 특성을 분석하였다. 그 결과 오염전자는 조사야의 중심축으로부터 넓게 퍼진 cone 모양의 분포를 하고 있었으며, 또한 오염전자가 갖는 평균 에너지는 약 3.0MeV로 나타났다. 그러므로 오염전자는 표면으로부터 2.5cm 깊이까지 분포하였다. 이러한 결과로써 광자선속에 포함된 오염전자를 제거하고 순수한 광자선을 이용한다면 buildup 영역 및 표면선량이 감소되고, 최대선량지점이 좀더 깊어진다.

  • PDF

2.5D 광자선 선량계산 알고리즘 개발 (Development of 2.5D Photon Dose Calculation Algorithm)

  • 조병철;오도훈;배훈식
    • 한국의학물리학회지:의학물리
    • /
    • 제10권2호
    • /
    • pp.103-114
    • /
    • 1999
  • 본 연구에서는 외부조사 광자선에 대한 3차원 선량계산 알고리즘 모델을 개발하기 위한 기초 연구로서 기존의 2D 선량 계산 알고리즘을 확장시켜 비동일 평면 조사가 가능한 2.5D 선량계산 모델을 개발하였다. 이를 위해 3차원 치료계획 및 선량계산에 적합하도록 환자 및 조사빔에 대한 3차원 좌표계 시스템을 정의하고, 이들 간의 좌표변환식을 유도하였다. 선량계산 알고리즘으로는 "Clarkson-Cunningham" 의 2D 광자선량 계산 알고리즘을 3차원으로 확장시켜 정형 조사면 및 비정형 조사면에 대한 선량계산과 wedge filter에 대한 선량계산이 가능하도록 하였고, Batho 방식을 적용하여 비 균질 보정을 구현하였다. 선량계산의 정확도를 평가하기 위해, AAPM TG #23 에 제시된 절차에 따라 자료에 제시된 4MV 광자선에 대한 실험 값과 본 연구에서 계산된 결과를 비교한 결과, 정형조 사면에 대한 PDD(percent depth dose)는 buildup 영역을 제외하면 $\pm$1% 이내, 비정형 조사면의 경우 $\pm$3% 이내에서 실험값과 일치하였다. 또한, wedge filter에 대한 PDD 및 profile은 $\pm$3% 이내, 45$^{\circ}$ oblique 입사빔에 대한 선량은 $\pm$4% 이내에서 실험값과 일치하였다. 비균질 보정의 경우 Lung/water 경계에서 7% 과소 평가되었고, Bone/water 경계에서 3% 과대 평가되는 것으로 나타났다. 이들 결과를 종합해 볼 때, 비균질 보정을 제외하고는 비교적 정확하게 선량을 계산하는 것으로 평가되었다. 추후 대부분의 상용 2.5D 치료계획시스템 (radiation treatment planning system; RTP)들이 비균질 보정 방법으로 사용하고 있는 Equivalent TAR(tissue-air ratio) 방식을 구현시키고자 하며, 본 연구에서 구현된 선량계산 모듈을 교육 및 연구용으로 활용할 수 있을 것으로 기대 한다.것으로 기대 한다.

  • PDF

종양의 온열치료를 위한 마이크로잔 조사장치의 제작과 응용 (Fabrication of Microwave Applicator for Hyperthermia and Thermal Distribution in Tissues)

  • 추성실;이종태;김귀언
    • Radiation Oncology Journal
    • /
    • 제2권1호
    • /
    • pp.11-20
    • /
    • 1984
  • The renewed interest in the use of hyperthermia in cancer therapy is bases on radiobiological and clinical evidence indicated that there may be a significant therapeutic advantage with the use of heat alone or combined with radiation or chemotherapy, There are many methods for generating heat for localized tumor as like radiofrequency, microwave, electromagnetic induction and ultrasound. But it is very difficult to be even thermal dose distribution and stable output of power and then the detection of temperature in tumor is difficult to be precise with thermocouples and semiconductor sensors. We designed the microwave heating generator, dipole antenna applicators and autometic temperature controlled thermocouples for localized hyperthermia on skin and in cavities. 1. The microwave generator with 120 W, 2,450MHz magnetron could be heating up to $40^{\circ}C\~50^{\circ}C\;for\;1\~2$ hours in living tissues. 2. The thermal dose distribution in tissue with microwave was described $42^{\circ}C\~44^{\circ}C$ with in 3 cm depth and $2\~6cm$ diameter area. 3. Skin surface heating applicator with spiral 3 times wave length antenna radiated high Power of microwave. 4, Intracavitary heating applicator with dipole antenna with autometic control temperature sensor kept up continuously constant temperature in tissue. 5. For constant thermal distribution, applied two steps power with 10W microwave after $17\~20W$ during first 10 minutes. 6. The cooling rate by blood flew in living tissue was rised as $10\%$ then meats.

  • PDF