• Title/Summary/Keyword: Tissue Doppler

Search Result 101, Processing Time 0.029 seconds

Ultrasonic Measurement of Tissue Motion for the Diagnosis of Disease

  • Beach Kirk W.
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.1 no.1
    • /
    • pp.3-12
    • /
    • 2003
  • Ultrasonic pulsed Doppler velocimetry has become a standard international method of classifying carotid disease. Because the measured angle adjusted velocity increases as the Doppler angle increases, examinations should be performed at a convenient standard Doppler examination angle. An angle of 60 degrees is achievable throughout most examinations. Multiple Doppler viewing angles allow the acquisition of velocity vectors during the cardiac cycle, revealing the complex velocity patterns. Ultrasonic velocimetry (whether Doppler or time domain) is based on changes in the phase of the ultrasound echo. Other examinations can be done based on the echo phase. Slow motions of organs such as the brain can be used to monitor changes in edema. Measurements of tissue strain due to the pulsatile filling of the arterioles. This plethysmographic imaging method can display differences in tissue perfusion because of different tissue types and changes in autonomic activity.

  • PDF

Comparison of Doppler and CT Angiography as a Predictor of Healing Diabetic Foot Ulcers (당뇨발 치유 가능성의 예측을 위한 도플러와 CT 혈관조영술의 비교)

  • Park, Doug-John;Kim, Hyon-Surk;Han, Seung-Kyu;Kim, Hee-Young;Chun, Kyung-Wook;Kim, Woo Kyung
    • Archives of Plastic Surgery
    • /
    • v.35 no.5
    • /
    • pp.495-500
    • /
    • 2008
  • Purpose: Adequate tissue oxygenation is considered as an essential factor for wound healing. In the non-diabetic population, an uncompromised macrocirculation generally leads to adequate tissue oxygenation. On the contrary, the macrocirculation in diabetic patients may not correlate with tissue oxygenation because of structural changes in the capillary basement membrane. Nevertheless, many medical professionals in Korea rely on macrocirculation evaluation when predicting wound healing potential of the diabetic ulcers. The purpose of this study is to compare reliability of two common macrocirculation assessment methods, Doppler probing and CT angiography, on tissue oxygenation in diabetic foot patients. Methods: Doppler and CT angiography scores were given according to the patency of the anterior and posterior tibial arteries. Tissue oxygenation was measured by transcutaneous partial oxygen tension($TcpO_2$). Doppler and CT angiography scores were statistically analyzed against $TcpO_2$ values. Sixty-eight diabetic foot ulcer patients were included in this study. Results: The test was carried out on Doppler score and $TcpO_2$ variables displayed a p-value of 0.0202, and concluded that the two variables were statistically dependent. The test used to determine for linear trends between Doppler scores and $TcpO_2$ variables displayed a p-value of 0.0149, displaying statistical linear trend between the two variables. On the contrary, the tests between CT angiography scores and $TcpO_2$ variables showed p-values of 0.1242 and 0.6590, that means no correlation between CT angiography and $TcpO_2$ scores. Conclusion: Doppler probing is more reliable than CT angiography in predicting tissue oxygenation of diabetic foot ulcers.

Echocardiographic Assessment of Papillary Muscle Size and Function in Normal Beagle Dogs

  • Kim, Mijin;Choi, Sooyoung;Choi, Hojung;Lee, Youngwon;Lee, Kija
    • Journal of Veterinary Clinics
    • /
    • v.36 no.3
    • /
    • pp.155-158
    • /
    • 2019
  • Morphologic changes or functional impairments of the papillary muscle (PM) can influence mitral valve competence. The purpose of this study was to investigate PM size and contractile function using two-dimensional and color tissue Doppler echocardiography in normal dogs. 35 unsedated Beagle dogs without cardiovascular disease were examined. The vertical (VD) and horizontal diameter (HD) of the posterior and anterior PM was measured at end-diastole, and compared with the thickness of the left ventricular posterior wall (LVPWd). Longitudinal systolic movement of the PM was quantified as myocardial velocity and strain using tissue Doppler. The VD, HD, and ratios (VD/LVPWd, HD/LVPWd, VD/HD) were significantly greater in the posterior than anterior PM (P < 0.001). The VD and HD of posterior PM and the HD of anterior PM were significantly correlated with LVPWd (r = 0.47, 0.44, and 0.42, respectively). Body weight was significantly correlated with VD of posterior PM (r = 0.37). The peak systolic tissue velocity of the PM was $4.93{\pm}1.25cm/sec$ and peak strain was $-30.83{\pm}11.92%$. PM size and systolic function can be quantitatively assessed using two-dimensional and tissue Doppler. The establishment of these objective PM measurements may be useful to evaluate morphological and functional abnormalities of the canine PM.

Laser Doppler blood flowmeter using self-mixing effect for the measurement of tissue blood flow. (조직혈류측정을 위한 자기혼합형 레이저 도플러 혈류계의 검토.)

  • Ko, Han-Woo;Choi, Duck-Hee
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.11
    • /
    • pp.67-70
    • /
    • 1993
  • This preliminary study describes the self-mixing effect of laser diode for the measurement of tissue blood flow. A self-mixing effect of laser diode was detected by the single-mode laser diode and the moving target, and the Doppler shifted frequency was thanked linearly with the driving frequency of speaker. The measured Doppler shifted frequency was compared with the simulated data.

  • PDF

Hyaluronic Acid Filler Injection Guided by Doppler Ultrasound

  • Won Lee
    • Archives of Plastic Surgery
    • /
    • v.50 no.4
    • /
    • pp.348-353
    • /
    • 2023
  • Doppler ultrasound can be used to detect almost all arteries of the face before injecting the hyaluronic acid (HA) filler. The relatively more dangerous sites of filler injection are the glabellar wrinkle, forehead, temple, nose, and nasolabial fold area, and it is recommended to map the vasculature of these areas by Doppler ultrasound before performing filler injection. The Doppler ultrasound detection method is included as a video. Internal carotid arterial branches, the supratrochlear, supraorbital, and dorsal nasal arteries, and external carotid arterial branches, the superficial temporal and facial arteries, are very important arteries when injecting HA filler; thus, Doppler ultrasound detection is recommended.

Observation with Calcifications of Breast Tissue Phantoms Using Acoustic Resonance (공명현상을 이용한 유방조직 팬텀의 석회화 관찰)

  • Ha, Myeung-Jin;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.61-69
    • /
    • 2008
  • Diagnosis of breast ultrasound is better than mammography in the early detection of breast cancer, but, it is difficult to detect microcalcification. We studied on detection for calcification of breast tissue using acoustic resonance and power doppler with 7.5 MHz linear probe in breast ultrasound. We first constructed breast tissue phantom made of gelatin and saw breast, and then observed calcification by the change of external vibration. Calcification injected breast tissue phantom visualized the difference for brightness and region of color in ROI regions of power doppler. Acoustic resonance almost never visualized in low frequency regions, plateau constituted in about 300-400 Hz and colors vanished according to the increase of frequency.

  • PDF

In Vivo Doppler-Based Measurement of Bending Vibration Velocity in Liver Vibrated by Lo7v Frequency Signal (초음파 Doppler법에 의한 비침투적인 생체조직의 진동속도 계측)

  • 박무훈;장윤석
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.407-412
    • /
    • 1997
  • In this paper, we present a new method to diagnose the characteristics of the soft tissue, especially a liver. In order to diagnose the characteristics of a liver, it is necessary to evaluate the propagation delay time and propagation velocity of bending vibration In a liver. For this purpose, we measure the propagation velocity of bending vibration in a liver for low frequency forced vibration using a standard ultrasonic Doppler diagnosis equipment. We have carried out preliminary experiments by using an ultrasonic probe of 3.5MHz and obtained some results. This new measurement method developed here can be applied to new research and medical fields for acoustic non-invasive diagnosis of soft tissue.

  • PDF

Diagnosis of Micro-Calcified Lesions of Breast Tissue Phantoms Using Acoustic Resonance Coupled with Power Doppler (공명현상과 파워도플러를 이용한 유방조직 팬텀의 미세 석회화 병변 진단)

  • Kim, Jeong-Koo;Ha, Myeung-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.2
    • /
    • pp.80-86
    • /
    • 2008
  • Breast ultrasound has many advantages over mammography but suffers from a shortcoming of being not suitable in detecting microcalcification. We studied on a method based on acoustic resonance and power Doppler to detect calcification of breast tissue using a typical 7.5 MHz linear probe used in breast ultrasound examination. We first constructed a breast tissue phantom made of gelatin and then observed calcified legions as external vibrations varied. Calcification injected to the breast tissue phantom being resonated different from the surrounding medium, and its acoustic resonance driven by external vibrations was visualized by differences for color brightness and area in ROI of power doppler. In low frequency regions, the acoustic resonance almost not appeared and showed a plateau in $300{\sim}600\;Hz$ and the color vanished as the frequency further increased.

Development of Portable Arrhythmia Moniter Using Microcomputer(I) (마이크로 컴퓨터를 이용한 휴대용 부정맥 모니터의 개발(I)-하드웨어 설계를 중심으로-)

  • 이명호;안재봉
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.2
    • /
    • pp.169-182
    • /
    • 1986
  • Pulsed ultrasonic Doppler system is a useful diagnostic instrument to measure blood-flow-velocity, velocity profile, and volume-blood-flow. This system is more powerful compare with 2-dimensional B-scan tissue image. A system has been deve- loped and ii being evaluated using TMS 32010 DSP. We use this DSP for the purpose of real-time spectrum analyzer to obtain spectrogram in singlegate pulsed Doppler system and for the serial comb filter to cancel clutter and zero crossing counter to estimate Doppler mean frequency in multigate pulsed Doppler system. The Doppler shift of the backscattered signals is sensed in a phase detector. This Doppler signal corresponds to the mean velocity over a some region in space defined by the ultrasonic beam dimensions, transmitted pulse duration, and transducer ban(iwidth. Multi- gate pulsed Doppler system enable the transcutaneous and simultaneous assessment of the velocities in a number of adjacent sample volumes as a continuous function of time. A multigate pulsed Doppler system processing the information originating from presented.

  • PDF

Assessment of neovascularization during bone healing using contrast-enhanced ultrasonography in a canine tibial osteotomy model: a preliminary study

  • Jeon, Sunghoon;Jang, Jaeyoung;Lee, Gahyun;Park, Seungjo;Lee, Sang-kwon;Kim, Hyunwook;Choi, Jihye
    • Journal of Veterinary Science
    • /
    • v.21 no.1
    • /
    • pp.10.1-10.12
    • /
    • 2020
  • Blood perfusion of skeletal muscle and callus was evaluated using contrast-enhanced ultrasonography (CEUS) in a canine osteotomy model to determine the applicability of CEUS in the assessment of neovascularization during fracture healing and to compare the vascular signals on CEUS between external skeletal fixation and cast-applied dogs. In 6 Beagle dogs, a simple transverse osteotomy was performed at the left tibial shaft and external skeletal fixation (n = 3) or a cast (n = 3) was applied. Radiography, power Doppler ultrasonography (power Doppler), and CEUS were performed until complete union was achieved. On CEUS, vascular changes were quantitatively evaluated by measuring peak intensity (PI) and time to PI in the soft tissue and callus and by counting the vascular signals. Vascular signals from the soft tissue were detected on power Doppler and CEUS on day 2. Significantly more vascular signals were detected by CEUS than by power Doppler. On CEUS, PI in the surrounding soft tissue was markedly increased after the fracture line appeared indistinctively changed on radiography in all dogs. In the cast-applied dogs, vascular signals from the periosteal and endosteal callus were detected on CEUS before mineralized callus was observed on radiography. CEUS was useful in assessing the vascularity of soft tissue and callus, particularly in indirect fracture healing, and provided indications of a normally healing fracture.