• 제목/요약/키워드: Tip60

검색결과 244건 처리시간 0.029초

소독멸균 방법에 따른 초음파 스케일링 팁에 부착된 세균의 양상 (Morphological aspect of the attached bacteria by the sterilization method of the ultrasonic scaling tip)

  • 남설희;김유린
    • 한국치위생학회지
    • /
    • 제15권4호
    • /
    • pp.713-718
    • /
    • 2015
  • Objectives: The purpose of the study was to investigate the bacterial morphology attached on ultrasonic scaler tips using no cleansing solution, alcohol cotton, liquid chemical disinfecting agent, and autoclave method. Methods: Scaling tip was applied to the mouth and the ultrasonic scaler tips were assigned to four groups. Group 1 was control group with no cleansing solution. Group 2 was treated with alcohol cotton. Group 3 was treated with 2% green Y-Na solution in liquid chemical disinfecting agent, and Group 4 was sterilized by autoclave method. Live bacteria were observed by phase contrast microscopy. The scanning electron microscopy(SEM) revealed the morphological characteristics of scaler surface. The type of attached bacteria were analyzed using SPSS 21.0 program. The data were analyzed by one-way analysis of variance(ANOVA) and Tukey's post-hoc test. Results: The types of sterilization methods had influences on the bacterial viability. The numbers of cocci, bacilli, spiral form bacteria, and filamentous bacteria was observed in $89.00{\pm}3.60%$, $29.67{\pm}3.51%$, $3.33{\pm}0.57%$ and $1.67{\pm}0.57%$ in control group, $31.67{\pm}3.51%$, $63.33{\pm}4.04%$, $2.00{\pm}1.00%$ and $1.67{\pm}0.57%$ in alcohol cotton group, $69.67{\pm}4.50%$, $12.33{\pm}2.51%$, 0% and 0% in liquid chemical disinfecting agent group, and 0.0%, 0.0%, 0.0% and 0.0% in autoclave method group. The clean surface of ultrasonic scaler tip was shown on SEM by autoclave method. Conclusions: The most effective sterilization method of ultrasonic scaler tip was the autoclave method. Autoclave method is the most effective sterilization method and can reduce the cross-infection in the dental clinic.

Microguidewire Looping to Traverse Stented Parent Arteries of Intracranial Aneurysms

  • Cho, Young Dae;Rhim, Jong Kook;Yoo, Dong Hyun;Kang, Hyun-Seung;Kim, Jeong Eun;Han, Moon Hee
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권2호
    • /
    • pp.262-268
    • /
    • 2017
  • Objective : Stents are widely used in coil embolization of intracranial aneurysms, but on occasion, a microcatheter must traverse a stented segment of artery (so-called trans-cell technique) to select an aneurysm, or double stenting may necessary. In such situations, microguidewire passage and microcatheter delivery through a tortuous stented parent artery may pose a technical challenge. Described herein is a microguidewire looping technique to facilitate endovascular navigation in these circumstances. Methods : To apply this technique, the microguidewire tip is looped before entering the stented parent artery and then advanced distally past the stented segment, with the loop intact. Rounding of the tip prevents interference from stent struts during passage. A microcatheter is subsequently passed into the stented artery for positioning near the neck of aneurysm, with microguidewire assistance. The aneurysm is then selected, steering the microcatheter tip (via inner microguidewire) into the dome. Results : This technique proved successful during coil embolization of nine saccular intracranial aneurysms (internal carotid artery [ICA], 6; middle cerebral artery, 2; basilar tip, 1), performing eight trans-cell deliveries and one additional stenting. Selective endovascular embolization was enabled in all patients, resulting in excellent clinical and radiologic outcomes, with no morbidity or mortality directly attributable to microguidewire looping. Conclusion : Microguidewire looping is a reasonable alternative if passage through a stented artery is not feasible by traditional means, especially at paraclinoid ICA sites.

표면조도처리 된 합금화 용융아연도금강판의 저항 점 용접성 (Resistance Spot Weldability of Surface Roughness Textured Galvannealed Steel Sheets)

  • 박상순;김기홍;강남현;김영석;임영목;최영민;박영도
    • 대한금속재료학회지
    • /
    • 제46권8호
    • /
    • pp.495-505
    • /
    • 2008
  • With the high proportion of zinc coated steels in body-in-white assembly, newly developed surface roughness textured galvannealed steel sheets have been introduced. In this study, zinc coated and surface roughness textured steel sheets were welded by resistance spot welding to investigate its weldability including electrode wear test. Based on the results of tensile-shear test, nugget diameter changes, and electrode tip growth test, it was clear that both surface roughness textured steels (GA-T and GA-E) showed good weldability. Also, there was no large difference in weldability and electrode wear behavior between GA-T and GA-E steels which have different surface roughness morphology. An analysis of electrode degradation showed Fe and Zn penetration through the electrode tip surface at 2400 welds reached $55{\sim}60{\mu}m$ and $75{\sim}80{\mu}m$, respectively. Therefore, there is no significant effect of surface roughness morphology on spot weldability of surface roughness textured galvannealed steel sheets. However, slight difference in thickness of alloying layers existing on electrode tip was found between GA-T and GA-E steels.

방아쇠수지가 손목터널증후군 환자의 악력, 통증 및 상지기능에 미치는 영향: 단면적 연구 (Effect of Trigger Finger on Pain, Grip Strength and Function of Upper Limb of Patients with Carpal Tunnel Syndrome: A Cross-sectional Study)

  • 김명권;윤다은
    • 대한물리의학회지
    • /
    • 제16권1호
    • /
    • pp.63-71
    • /
    • 2021
  • PURPOSE: The purpose of this study was to investigate the effects of trigger finger on pain, muscle strength and function in carpal tunnel syndrome (CTS) patients. METHODS: A total of 60 subjects (30 carpal tunnel syndrome with trigger finger and 30 carpal tunnel syndrome without trigger finger) were assessment for pain, muscle strength (power grip, key pinch , tip to tip pinch, three jaw pinch) and function. The effect sizes of the two groups were compared, and the correlation between the trigger finger and each variable was analyzed. RESULTS: The results showed that there were significantly difference in the pain, muscle strength excluding three jaw pinch and function (p < .05). The results also showed correlation between trigger finger and pain (r = .552), muscle strength excluding three jaw pinch (power grip r = -.296, key pinch r = -.260, tip to tip pinch r = -.285), and function (r = .375). The function of carpal tunnel syndrome patients was related to pain (r = .550) and power grips (r = -.324) of muscle strength. CONCLUSION: In carpal tunnel syndrome patients with trigger finger compared to carpal tunnel syndrome, muscle weakness, pain increase, and function reduction were shown. In addition, trigger finger are correlated with muscle strength, pain and function, and muscle weakness and increased pain affect the daily living of carpal tunnel syndrome patients with triggers finger. Therefore, physical therapy interventions of carpal tunnel syndrome patients with trigger finger should be combined with treatment for muscle strength enhancement as well as pain reduction.

Comparison of Surface Microhardness of the Flowable Bulk-Fill Resin and the Packable Bulk-Fill Resin according to Light Curing Time and Distance

  • Hyung-Min Kim;Moon-Jin Jeong;Hee-Jung Lim;Do-Seon Lim
    • 치위생과학회지
    • /
    • 제23권2호
    • /
    • pp.123-131
    • /
    • 2023
  • Background: As a restorative material used to treat dental caries, the light-curing type resin is widely used, but it has the disadvantage of polymerization shrinkage. The Bulk-Fill composite resin was developed to solve these shortcomings, but the existing research mainly focused on comparing the physical properties of a composite resin and a Bulk-Fill resin. A study on the light curing time and distance of the Bulk-Fill resin itself tend to be lacking. Methods: This study compares the surface microhardness of specimens prepared by varying the light curing time and distance of smart dentin replacement (SDR) as a flowable Bulk-Fill resin and Tetric N-ceram as a packable Bulk-Fill resin, and confirms the polymerization time and distance that becomes the optimum hardness. To determine the hardness of the specimen, it was measured using the Vickers Hardness Number (Matsuzawa MMT-X, Japan). Results: In SDR, the surface microhardness decreased as the distance increased in all time groups in the change distance from the curing tip. In the change of light curing time with respect to the distance from curing tip, the surface microhardness increased as the time increased. In Tetric N-ceram, the surface microharness showed no significant difference in the change of the distance of curing tip in the group of 20 and 60 second. But in the group of 10 and 40 seconds, decreased as the distance increased. The surface microharness increased as the light curing time increased in all distance groups. Conclusion: When using SDR and Tetric N-ceram in clinical practice, it is considered that as the distance from the polymerization reactor tip increases, a longer light curing time than the polymerization time recommended by the manufacturer is required.

이중공기공급 이유체노즐의 선회각 변화에 따른 분무특성 (Effect of Swirl Angle on the Atomization Characteristics in Two-Fluid Nozzle with Dual Air Supplying System)

  • 김의수;강신명;최윤준;김덕진;이지근;노병준
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.54-60
    • /
    • 2008
  • The atomization characteristics of the dual air supplying twin-fluid nozzle were investigated experimentally using PIV and PDA systems. The two-fluid nozzle is composed of three main parts: the feeding injector to supply fluid that is controlled by a PWM (pulse-width modulation) mode, the adaptor as a device with the ports for supplying the carrier and assist air and the main nozzle to produce the spray. The main nozzle has the swirl tip with four equally spaced tangential slots, which give the injecting fluid an angular momentum. The angle of the swirl tip varied with 0$^{\circ}$ 30$^{\circ}$, 60$^{\circ}$ and 90$^{\circ}$, and the ratios of carrier air to assist air and ALR(total air to liquid) were 0.55 and 1.23, respectively. The macroscopic behavior of the spray was investigated using PIV system, and the mean velocity, turbulent intensity and SMD distributions of the sprays were measured using PDA system. As the results, the mean axial velocity at the spray centerline decrease with the increase of the swirl angle. The turbulent intensities of the axial and radial velocity were increased with the increase of the swirl angle. The mean SMD (Sauter mean diameter) of the radial direction along the axial distance shows the lowest value at the swirl angle of 60$^{\circ}$.

  • PDF

Study of cracks in compressed concrete specimens with a notch and two neighboring holes

  • Vahab, Sarfarazi;Kaveh, Asgari;Shirin, Jahanmiri;Mohammad Fatehi, Marji;Alireza Mohammadi, Khachakini
    • Advances in concrete construction
    • /
    • 제14권5호
    • /
    • pp.317-330
    • /
    • 2022
  • This paper investigated computationally and experimentally the interaction here between a notch as well as a micropore under uniaxial compression. Brazilian tensile strength, uniaxial tensile strength, as well as biaxial tensile strength are used to calibrate PFC2d at first. Then, uniaxial compression test was conducted which they included internal notch and micro pore. Experimental and numerical building of 9 models including notch and micro pore were conducted. Model dimensions of models are 10 cm × 10 cm × 5 cm. Joint length was 2 cm. Joints angles were 30°, 45° and 60°. The position of micro pore for all joint angles was 2cm upper than top of the joint, 2 cm upper than middle of joint and 2 cm upper than the joint lower tip, discreetly. The numerical model's dimensions were 5.4 cm × 10.8 cm. The fractures were 2 cm in length and had angularities of 30, 45, and 60 degrees. The pore had a diameter of 1 cm and was located at the top of the notch, 2 cm above the top, 2 cm above the middle, and 2 cm above the bottom tip of the joint. The uniaxial compression strength of the model material was 10 MPa. The local damping ratio was 0.7. At 0.016 mm per second, it loaded. The results show that failure pattern affects uniaxial compressive strength whereas notch orientation and pore condition impact failure pattern. From the notch tips, a two-wing fracture spreads almost parallel to the usual load until it unites with the sample edge. Additionally, two wing fractures start at the hole. Both of these cracks join the sample edge and one of them joins the notch. The number of wing cracks increased as the joint angle rose. There aren't many AE effects in the early phases of loading, but they quickly build up until the applied stress reaches its maximum. Each stress decrease was also followed by several AE effects. By raising the joint angularities from 30° to 60°, uniaxial strength was reduced. The failure strengths in both the numerical simulation and the actual test are quite similar.

BTA드릴의 절삭 기구와 마모 특성에 관한 연구 (A Study on Cutting Mechanism and Wear Character for BTA Drill)

  • 장성규;전언찬
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.105-108
    • /
    • 1995
  • So far,in deep drilling process there are several manufacturing problems such as hole deviation, hole over size, circularity,straightness and surface roughness. Whit regard to these problems, we atudied the abrasion process on carbided tip of BTA drill and got the follow test results through the abrasion characteristic test and analysis on cutting mechanism for the drill tooth and guide pad. 1) In SM55C drilling process, the most stable and reasonable drilling speed range for optmum abrasion characteristic of drill tooth was 60m.min. 2) The total drilling torque was about 60kg .deg.cm on condition drilling speed 60m/min and 0.15mm/rev. These results show that the theoretical burnising torque is well accord with the tested torque which is working on guide pad.

  • PDF

한국산 가자미과 어류의 미설골의 형태에 관하여 (MORPHOLOGY OF UROHYAL BONES OF PLEURONECTIDAE FISHES IN KOREAN WATERS)

  • 김용억
    • 한국수산과학회지
    • /
    • 제5권4호
    • /
    • pp.121-127
    • /
    • 1972
  • 한국산 가자미과어류의 미설골의 형태를 비교 관찰하여 다음과 같은 특질을 가지고 있음을 알았다. 1. 좌골부선단의 위치가 속 또는 종에 따라 달리하고 있는데, 주부의 선단에서 각을 이루는 부분까지의 거리의 1/2(Platichthys 및 Cleisthenes), 앞쪽에서 1/3(Eopsetta 및 Tanakius), 뒷쪽에서 1/4(Verasper 및 Dexistes), 동일위치 (Limanda, Clidoderma, Glyptocephalus 및 Microstomus), 2배의 거리 (Kareius 및 Pleuronichthys)에 있는 것등으로 나누어지며 , 좌골부선단의 모양은 절두형인 것(Eopsetta, Verasper, Limanda, Platichthys, Tanakius 및 Glyptocephalus), 끝이 뾰족하고 위로 향한 것(Kareius, Pleuronichthys, Clidoderma 및 Microstomus), 끝이 뾰족하며 앞으로 향한 것(Cleisthenes 및 Dexistes)등 세가지형으로 나누어진다. 2. 분문돌기는 발달정도에 따라 차이가 있고 그 모양도 다양하다. 비교적 큰 것에 속하는 것(Eopsetta, Verasper, Platichthys, Tanakius, Kareius 및 Dexistes), 작은 것(Pleuronichthys 및 Clidoderma), 막대기 모양인 것(Glyptocephalus), 보통인 것(Limanda, Microstomus 및 Cleisthenes)등 의 네가지로 나누어지며, 모양은 상연이 둘로 갈라져 날개 모양을 한 것(Eopsette, Verasper, Limanda, Platichthys, Tanakius, Glyptocephalus, Kareius, Pleuronichthys 및 Clidoderma), 끝이 뾰족한 것 (Microstomus 및 Cleisthenes), 절두형에다 내연이 발달한 것(Dexistes) 등 세가지로 나누어진다. 3. 주부와 좌골부가 만드는 각도는 Pleuronichthys, Clidoderma, Microstomus의 반타원형을 제외하고는 $30^{\circ}$에서 $60^{\circ}$까지의 각도를 이루고 있다.

  • PDF

상악견치 후방견인시 저항원 조절을 위한 MAS(Molar Anchoring Spring)의 초기 응력분포에 관한 광탄성학적 연구 (A PHOTOELASTIC STUDY ON THE INITIAL STRESS DISTRIBUTION OF THE MOLAR ANCHORING SPRING(MAS) DURING RETRACTION OF THE MAXILLARY CANINE)

  • 전윤식
    • 대한치과교정학회지
    • /
    • 제26권4호
    • /
    • pp.341-348
    • /
    • 1996
  • 저자는 마찰견인법으로 상악견치 후방견인시 저항원상실을 최소화하기 위해 근심 경사된 구치를 직립시키는 Molar Uprighting Spring의 작용기전을 응용하고 마찰견인법의 장점을 이용하여 임상적으로 사용이 용이하며 저항원상실이나 견치의 조절되지 못한 경사이동(uncontrolled tipping)등의 부작용을 최소화 할 수 있는 장치인 Molar Anchoring Spring(MAS)을 고안하였다. MAS를 임상에 적용한 결과 비교적 만족스러운 결과를 얻어 이에 장치를 소개하며 MAS의 저항원 조절능력과 견치의 이동양상을 평가하기 위하여 광탄성 모형을 제작한 후 주호선에 diameter 0.009" lumen size 0.030" NiTi closed coil spring만을 장착하여 250gm의 견인력이 발생하도록 한 경우와, 같은 NiTi closed coil spring으로 동일한 견인력 이 발생하도록 하고 .017" X .025" TMA wire로 $60^{\circ}$의 tip-back bend를 부여하여 수직교정력이 60-70gm이 되도록 제작한 MAS를 제1대구치 auxiliary tube에 삽입하고 견치 전방에 걸어준 경우를 비교실험 하여 견치견인시 초기응력분포를 관찰한 결과 다음과 같은 결과를 얻었다. 1. 주호선(main arch wire)에 저항원 조절을 위한 조치없이 견치에 수평견인력만을 가했을 때 구치부에 심한 저항원상실은 물론 견치의 원심이동양상도 조절되지 못한 경사이동(uncontrolled tipping)으로 나타났다. 2. 구치부의 저항원 조절을 위해 사용한 MAS는 견치의 원심이동 초기에 구치부 저항원 조절효과와 견치의 정출없는 조절된 경사이동(controlled tipping)을 유도할 수 있는 장치로 나타났다.

  • PDF