• 제목/요약/키워드: Tip Leakage

검색결과 172건 처리시간 0.024초

Electrical characteristics of lateral poly0silicon field emission triode using LOCOS process

  • Lee, Jae-Hoon;Lee, Myoung-Bok;Park, Dong-Il;Ham, Sung-Ho;Lee, Jong-Hyun;Lee, Jung-Hee
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제3권1호
    • /
    • pp.38-42
    • /
    • 1999
  • Using the LOCOS process, we have fabricated the lateral type polysilicon field emission triodes with poly-Si/oxide/Si structure and investigated their current-voltage characteristics for three biasing modes of operation. The fabricated devices exhibit excellent electrical performances such as a relatively low turn-on anode voltage of 14 V at VGC = 0V, a stable and high emission current of 92${\mu}$A/triode over 90 hours, a small gate leakage current of 0.23 ${\mu}$A/triode and an outstanding transconductance of 57${\mu}$S/5triodes at VGC = 5V and VAC = 26V. these superior electrical operation is believed to be due to a large field enhancement effect, which is related to the sharp cathode tips produced by the LOCOS process as well as the high aspect ratio (height /radius ) of the cathode tip end.

  • PDF

극저비속도 원심펌프의 성능과 내부유동특성에 관한 연구 (A Study on the Performance and Internal Flow Characteristics of a Very Low Specific Speed Centrifugal Pump)

  • 쿠로카와준이치;이영호;최영도
    • 대한기계학회논문집B
    • /
    • 제29권7호
    • /
    • pp.784-794
    • /
    • 2005
  • In the very low specific speed range ($n_s=0.24$ < 0.25, non-dimensional), the efficiency of centrifugal pump designed by a conventional method is very low in common. Therefore, positive-displacement pumps have long been used widely. Recently, since the centrifugal pumps are becoming higher in rotational speed and smaller in size, there expects to develop a new centrifugal pump with a high performance to replace the positive-displacement pumps. The purpose of this study is to investigate the internal flow characteristics of a very low specific speed centrifugal pump and to examine the effect of internal flow pattern on pump performance. The results show that the theoretical head definition of semi-open impeller should be revised by the consideration of high slip factor in the semi-open impeller, and the leakage flow through the tip clearance results in a large effect on the impeller internal flow. Strong reverse flow at the outlet of semi-open impeller reduces the absolute tangential velocity considerably, and the decreased absolute tangential velocity increasese the slip factor with the reduction of theoretical head.

Phytotoxin Production of Nigrospora sphaerica Pathogenic on Turfgrasses

  • Park, Gyung-Ja;Kim, Jin-Cheol;Shon, Mi-Jeong;Kim, Heung-Tae;Cho, Kwang-Yun
    • The Plant Pathology Journal
    • /
    • 제16권3호
    • /
    • pp.137-141
    • /
    • 2000
  • A causal fungus of turfgrass blight was isolated from the infected leaves of zoysiagrass (Zoysia japonica Steud.) and identified as Nigrospora sphaerica (Sacc.) Mason by using a light misroscope. Its conidia are large (14-20 ${\mu}{\textrm}{m}$ diameter), shiny, black, aseptate, and smooth-walled spheres. The fungus caused typical blighting symptoms on the two turfgrass plants of bermudagrass (Cynodon dactylon (L.) Pers.) and bentgrass (Agrostis palustris Huds.). The fungus was found to produce a phytotoxic subtance to be associated with the pathogenic mechanism. A phytotoxin was isolated from the liquid cultures of N. sphaerica by repeated silica gel column chromatography and its structure was determined to be 5, 6-dihydro-5-hydroxy-6-propenyl-2H-pyr-2-one (T-3 compound). It was not a host-specific toxin showing phytotoxic effects to various plants inclusing turfgrasses in the leaf-wounding assay, the whole plant test, and the cellular leakage test. The compound caused leaf tip dieback symptoms in turfgrass plants similar to those caused by the pathogen. Thus, T-3 compound is thought to be involved in the development of Nigrospora blight.

  • PDF

로터 블레이드 스윕을 적용한 부분흡입형 축류 초음속 터빈의 성능특성에 대한 수치적 연구 (A Numerical Study on the Performance Characteristics of a Partial Admission Axial Supersonic Turbine with Swept Rotor Blades)

  • 정수인;김귀순
    • 한국추진공학회지
    • /
    • 제17권3호
    • /
    • pp.1-8
    • /
    • 2013
  • 본 연구에서는 액체로켓엔진의 터보펌프용 초음속 터빈 로터 블레이드에 스윕 각도 ${\pm}15^{\circ}$를 적용하여 전방스윕(FSW), 후방스윕(BSW)모델의 유동형태 및 성능을 기준모델(NSW)과 비교하여 스윕 적용의 효과를 살펴보았다. 3차원 Navier-Stokes 유동해석에는 상용 코드인 FLUENT 6.3 Parallel을 사용하였다. BSW 모델은 기준 모델(NSW)에 비해 팁 간극으로 빠져나가는 누설 손실량을 줄이는데 효과가 있었고 정효율 증가에도 영향을 미쳤다. BSW 모델은 앞전 충격파의 강도를 다소 완화 시키고 허브 부근의 영역에서 다른 모델에 비해 좋은 성능을 보인다.

Identification of the Failure of VFD Heat Sink at Fossil Power Plant

  • Jung, Jine-sung;Lee, Han-sang;Kim, Min-tae;Kim, Eui-hyun
    • Corrosion Science and Technology
    • /
    • 제8권4호
    • /
    • pp.153-156
    • /
    • 2009
  • The water cooling system for VFD (Variable Frequency Drive) of a fossil fuel power plant was reported to be shut down due to a water leak at the metal connection of the heat-sink to the hoses. In order to identify the cause of the failure, the system was visually inspected, and corrosion products were analyzed with SEM equipped with EDX. The failure was observed repeatedly at the nipples of certain location, suggesting galvanic corrosion. In a U-shaped heat sink with two nipples, for inlet and outlet, only one nipple was corrosively damaged at the tip, while the other was not. Most of the corrosion products were observed at the sound nipple and in the filter, identified as $Cu(OH)_2$. Some other corrosion products, composed of mostly $Cu_2O$, were found at the corrosively attacked nipple. A fair amount of Cl was also detected on the surface of the damaged nipple. It was concluded that galvanic corrosion was occurred due to a current leakage over the whole system, and the damage was accelerated by the accumulated chlorine ions in the cooling water.

PTV 계측법에 의한 극저비속도 원심펌프의 내부유동특성에 관한 연구 (A Study on the Internal Flow Characteristics of a Very Low Specific Speed Centrifugal Pump by PTV)

  • 최영도;마쯔이준;쿠로카와준이치;이영호
    • 한국유체기계학회 논문집
    • /
    • 제9권1호
    • /
    • pp.9-18
    • /
    • 2006
  • In the range of very low specific speed ($n_s<0.25$, non-dimensional), the performance of a centrifugal pump is much different from that of a centrifugal pump of normal ns and the efficiency of the pump drops rapidly with the decrease of $n_s$. In order to examine the reason of unstable performance characteristics of the very low $n_s$- centrifugal pump, the internal flow of the pump with a semi-open impeller is measured by a PTV(Particle Tracking Velocimetry) system. The purpose of this study is to make clear the internal flow characteristics and to obtain basic knowledge of the pump performance. The results show that the leakage flow through tip clearance give a strong effect on the flow pattern of impeller passage. A large vortex in the impeller passage and a strong reverse flow at impeller outlet are formed in the range of small flow rates, and the vortex and the reverse flow together reduce the absolute tangential velocity at the impeller outlet and cause the performance instability.

점성 손실모델 도입에 의한 축류 압축기 준 3차원 압축성 유동해석 (A Study on the Quasi-3-Dimensional Compressible Flow Calculation by Introduction of Viscous Loss Model in Axial-Flow Compressor)

  • 조강래;이진호;김주환
    • 대한기계학회논문집
    • /
    • 제13권5호
    • /
    • pp.1044-1051
    • /
    • 1989
  • 본 연구에서는 Wu가 제시한 수학적 모델에 기초를 둔 비점성 준3차원 유동해 석에 실제 유체의 점성효과 및 2차유동 등에 의해 발생하는 손실들을 손실모델로 반영하여 그 타당성 유무를 검토하는 데 목적을 두었다.

비전도성 액체의 전기수력학적 미립화를 위한 전하 주입 특성에 관한 실험적 연구 (An Experimental Study on Charge Injection to Non-Conducting Liquid for Electrohydrodynamic Atomization)

  • 이기준;박종승;이상용
    • 대한기계학회논문집B
    • /
    • 제28권11호
    • /
    • pp.1376-1383
    • /
    • 2004
  • In the present work, a series of experiments have been performed on electro-hydrodynamic atomization of non-conducting liquid using a charge injection type nozzle. Effects of liquid flow rate, input voltage, and distance between the needle and the ground electrode (nozzle-embedded metal plate) have been examined. For fixed electrode distances, total and spray currents increase with the increase of liquid flow rate and input voltage. When the distance between the needle tip and the ground electrode becomes closer, the total, leakage and spray currents increase, while the onset voltage for the dielectric breakdown decreases. When the electric field strength of the liquid jet exceeds that for the air breakdown, a portion of the electric charges in the liquid jet is dissipated into the ambient air, and the charge density shows a limiting value. Atomization quality can be improved by increasing the liquid flow rate due to the higher charge density and the enhanced aerodynamic effect.

스윕 각이 적용된 부분 흡입형 초음속 축류 터빈의 정상, 비정상 공력 특성에 관한 수치적 연구 (Numerical Study on Steady and Unsteady Flow Characteristics of Nozzle-Rotor Flow in a Partial Admission Supersonic Axial Turbine with Sweep Angle)

  • 정수인;김귀순
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2012년도 제38회 춘계학술대회논문집
    • /
    • pp.173-179
    • /
    • 2012
  • 본 논문에서는 부분 흡입형 초음속 터빈의 로터 블레이드에 ${\pm}15^{\circ}$의 스윕 각도를 적용하여 그에 의한 효과와 공력 특성을 살펴보기 위해 정상상태 유동해석과 비정상상태 유동해석을 동시에 수행하고 그 결과를 비교해 보았다. 3차원 Navier-Stokes 유동해석에는 상용 코드인 FLUENT 6.3 Parallel을 사용하였다. 모든 계산 케이스들에서 정상상태 유동해석에 비해 비정상상태의 경우가 손실이 더욱 크게 나오는 결과를 나타내었다. 후방스윕(BSW)모델은 기준모델(NSW)에 비해 팁 간극으로 빠져나가는 누설 손실량을 줄이는데 큰 효과가 있었고 비정상상태 유동 해석에서는 로터 출구면 정효율의 증가현상이 더욱 뚜렷하게 나타났다.

  • PDF

Scanning Probe Microscopy를 이용한 국소영역에서의 실리콘 나노크리스탈의 전기적 특성 분석 (Characterization of Electrical Properties of Si Nanocrystals Embedded in a SiO$_{2}$ Layer by Scanning Probe Microscopy)

  • 김정민;허현정;강치중;김용상
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권10호
    • /
    • pp.438-442
    • /
    • 2005
  • Si nanocrystal (Si NC) memory device has several advantages such as better retention, lower operating voltage, reduced punch-through and consequently a smaller cell area, suppressed leakage current. However, the physical and electrical reasons for this behavior are not completely understood but could be related to interface states of Si NCs. In order to find out this effect, we characterized electrical properties of Si NCs embedded in a SiO$_{2}$ layer by scanning probe microscopy (SPM). The Si NCs were generated by the laser ablation method with compressed Si powder and followed by a sharpening oxidation. In this step Si NCs are capped with a thin oxide layer with the thickness of 1$\~$2 nm for isolation and the size control. The size of 51 NCs is in the range of 10$\~$50 m and the density around 10$^{11}$/cm$^{2}$ It also affects the interface states of Si NCs, resulting in the change of electrical properties. Using a conducting tip, the charge was injected directly into each Si NC, and the image contrast change and dC/dV curve shift due to the trapped charges were monitored. The results were compared with C-V characteristics of the conventional MOS capacitor structure.