• 제목/요약/키워드: Tip

검색결과 5,531건 처리시간 0.038초

가스터빈 블레이드 끝단 형상에 따른 블레이드 끝단 및 그 주변에서의 열전달 계수 변화 (Effect of Blade Tip Geometry on Heat Transfer Coefficients on Gas Turbine Blade Tips and Near Tip Regions)

  • 곽재수
    • 대한기계학회논문집B
    • /
    • 제30권4호
    • /
    • pp.328-336
    • /
    • 2006
  • Detailed heat transfer coefficient distributions an two. types of gas turbine blade tip, plane tip and squealer tip, were measured using a hue-detection base transient liquid crystals technique.. The heat transfer coefficients an the shroud and near tip regions of the pressure and suction sides af the blade were also. measured. The heat transfer measurements were taken at the three different tip gap clearances af 1.0%, 1.5%, and 2.5% of blade span. Results shaw the overall heat transfer coefficients on the tip and shroud with squealer tip blade were lower than those with plane tip blade. By using squealer tip, however, the reductions af heat transfer coefficients near the tip regions of the pressure and suction sides were nat remarkable.

평면팁과 스퀼러팁 터빈 동익의 압력손실 특성 비교 (Comparisons of Aerodynamic Loss Generated by a Squealer-Tip Turbine Rotor Blade with That by a Plane-Tip One)

  • 채병주;이상우
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.161-164
    • /
    • 2006
  • Three-dimensional flow and aerodynamic loss in the tip-leakage flow region of a high-turning first-stage turbine rotor blade with a squealer tip have been measured with a straight miniature five-hole probe for the tip gap-to-chord ratio, h/e, of 2,0%. This squealer tip has a indent-to-chord ratio, $h_{st}/c$, of 5.5%. The results are compared with those for a plane tip ($h_{st}/c\;=\;0.0%$). The squealer tip tends to reduce the mass flow through the tip gap and to suppress the development of the tip-leakage vortex. Therefore, it delivers lower aerodynamic loss in the near-tip region than the plane tip does. At the mid-span, however, the aerodynamic loss has nearly the same value for the two different tips.

  • PDF

스퀄러팁 터빈 동익 하류에서의 3차원 유동 및 압력손실 (Three-Dimensional Flow and Aerodynamic Loss Downstream of a Turbine Rotor Blade with a Squealer Tip)

  • 채병주;이상우
    • 대한기계학회논문집B
    • /
    • 제30권9호
    • /
    • pp.913-920
    • /
    • 2006
  • Three-dimensional flow and aerodynamic loss in the tip-leakage flow region of a high-turning first-stage turbine rotor blade with a squealer tip have been measured with a straight miniature five-hole probe for the tip gap-to-chord ratio, h/c, of 2.0%. This squealer tip has a indent-to-chord ratio, $h/{st}/c$, of 5.5%. The results are compared with those for a plane tip $(h_{st}/c=0.0%)$. The squealer tip tends to reduce the mass flow through the tip gap and to suppress the development of the tip-leakage vortex. Therefore, it delivers lower aerodynamic loss in the near-tip region than the plane tip does. At the mid-span, however, the aerodynamic loss has nearly the same value for the two different tips.

프로펠러팬에서의 Tip Vortex 거동 (Behavior of Tip Vortex in a Propeller Fan)

  • 김성협;고천아인;정상아홍
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1377-1382
    • /
    • 2004
  • Flow fields in a half ducted propeller fan have been investigated by three-dimensional Reynolds-averaged Navier-Stokes (RANS) simulations and a vortex core identification technique. The simulation at the design operating condition shows that the tip vortex onset point is located at 30 percent tip chord of the suction surface on the blade tip. There is no interaction between the tip vortex and the adjacent blade, so that the tip vortex smoothly convects to the rotor exit. However, the high vorticity in the tip vortex causes the wake and the tip leakage flow to be twined around the tip vortex and to interact with the pressure surface of the adjacent blade. This flow behavior corresponds well with experimental results by Laser Doppler Velocimetry. On the contrary, the simulation at the low-flowrate operating condition shows that the tip vortex onset point is located at the 60 percent tip chord of the suction surface. In contrast to the design operating condition, the tip vortex grows almost tangential direction, and impinges directly on the pressure surface of the adjacent blade.

  • PDF

수치계산에 의한 축류터보기계의 유동장과 유동온실의 평가 III [회전차 익말단의 누설손실과 효율저하에 대한 평가] (Evaluation of Flowfield and Flow Losses insied Axial Turbomachinery Using Numerical Calculation [Evaluation of Tip Leakage Loss and Reduction of Efficiency by Tip Clearance])

  • 노수혁;조강래
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1998년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.240-247
    • /
    • 1998
  • Leakage vortices formed near blade tip causes an increase of total pressure loss near casing endwall region and as a result, the efficiency of rotor decreases. The reduction of rotor efficiency is related to the size of tip clearance. In this study, the three-dimensional flowfields in an axial flow rotor were calculated with varying tip clearance under various flow rates, and the numerical results were compared with experimental ones. The effects of tip clearance and attack angle on the leakage vortex and overall performance, and the less distributions were investigated through numerical calculations. In this study, tip leakage flow rate and total pressure loss by tip clearance were evaluated using numerical results and aprroximate equations were presented to evaluate the reduction of rotor efficiency by tip leakage flow.

  • PDF

운전 익단간극을 고려한 마이크로터빈 코어용 원심압축기의 성능특성 연구 (Performance Test of Centrifugal Compressor for Microturbine with Running Tip Clearance)

  • 강정식;임병준;차봉준;양수석
    • 한국유체기계학회 논문집
    • /
    • 제8권1호
    • /
    • pp.7-15
    • /
    • 2005
  • Tip clearance of centrifugal compressor affects the performance. Larger tip clearance results in lower efficiency. What really affects the performance is the running tip clearance, not the cold tip clearance. When the compressor is operating, blade strain and the pressure difference between impeller backplate and hub affects the running tip clearance. This paper describes measured running tip clearance and its effects on the performance of centrifugal compressor. Cold tip clearance before operation was 0.4 mm and running tip clearance varied from 0.86 mm to 0.25 mm with impeller exit pressure. As the pressure at impeller exit increases, the running tip clearance tends to decreases. The target running tip clearance for Compressor at $100\%$ speed was 0.3 mm, and it turned out to be exactly 0.30 mm from experiment.

가스 터빈 블레이드 팁과 그 주변에서의 열전달 계수 (Heat Transfer Coefficients on a Gas Turbine Blade Tip and Near Tip Regions)

  • 곽재수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.430-435
    • /
    • 2003
  • Detailed heat transfer coefficient distributions on a gas turbine blade tip were measured using a hue-detection base transient liquid crystals technique. The heat transfer coefficients on the shroud and near tip regions of the pressure and suction sides of a blade were also measured. Both plane tip and squealer tip blade were considered. The heat transfer measurements were taken at the three different tip gap clearance of 1.0%, 1.5%, and 2.5% of blade span. Results show the overall heat transfer coefficients on the tip and shroud with squealer tip blade were lower than those with plane tip blade. However, the reductions of heat transfer coefficients near the tip regions of the pressure and suction sides were not remarkable.

  • PDF

운전 익단간극을 고려한 마이크로터빈 코어용 원심압축기의 성능특성 연구 (Performance Test of Centrifugal Compressor for Microturbine with Running Tip Clearance)

  • 강정식;임병준;차봉준;양수석
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.411-418
    • /
    • 2004
  • Tip clearance of centrifugal compressor affects the performance. Larger tip clearance results in lower efficiency. What really affects the performance is the running tip clearance, not the cold tip clearance. When the compressor is operating, blade strain and the pressure difference between impeller backplate and hub affects the running tip clearance. This paper describes measured running tip clearance and its effects on the performance of centrifugal compressor. Cold tip clearance before operation was 0.4 mm and running tip clearance varied from 0.86 mm to 0.25 mm with impeller exit pressure. As the pressure at impeller exit increases, the routing tip clearance tends to decreases. The target running tip clearance for compressor at $100\%$ speed was 0.3 mm and it turned out to be exactly 0.30 mm from experiment.

  • PDF

Model-based Reference Trajectory Generation for Tip-based Learning Controller

  • Rhim Sungsoo;Lee Soon-Geul;Lim Tae Gyoon
    • Journal of Mechanical Science and Technology
    • /
    • 제19권spc1호
    • /
    • pp.357-363
    • /
    • 2005
  • The non-minimum phase characteristic of a flexible manipulator makes tracking control of its tip difficult. The level of the tip tracking performance of a flexible manipulator is significantly affected by the characteristics of the tip reference trajectory as well as the characteristics of the flexible manipulator system. This paper addresses the question of how to best specify a reference trajectory for the tip of a flexible manipulator to follow in order to achieve the objectives of reducing : tip tracking error, residual tip vibration, and the required actuation effort at the manipulator joint. A novel method of tip-based learning controller for the flexible manipulator system is proposed in the paper, where a model of the flexible manipulator system with a command shaping filter is used to generate a smooth and realizable tip reference trajectory for a tip-based learning controller.

수치계산에 의한 축류터보기계의 회전차 익말단의 누설손실과 효율저하에 대한 평가 (Evaluation of Tip Leakage Loss and Reduction of Efficiency of Axial Turbomachinery Using Numerical Calculation)

  • 노수혁;조강래
    • 한국유체기계학회 논문집
    • /
    • 제2권1호
    • /
    • pp.73-80
    • /
    • 1999
  • Leakage vortices formed new blade tip causes an increase of total pressure loss near the casing endwall region and as a result, the efficiency of rotor decreases. The reduction of rotor efficiency is related to the size of the tip clearance. In this study, the three-dimensional flowfields in an axial flow rotor were calculated by varying the tip clearance under various flow rates, and the numerical results were compared with experimental ones. The effects of tip clearance and attack angle on the leakage vortex and overall performance, and the loss distributions were investigated through numerical calculations. In this study, tip leakage flow rate and total pressure loss by tip clearance were evaluated using numerical results and approximate equations were presented to evaluate the reduction of rotor efficiency by tip leakage flow.

  • PDF