• Title/Summary/Keyword: Timing monitoring

Search Result 136, Processing Time 0.025 seconds

Enlargement of Extraspinal Cysts in Spinal Dysraphism : A Reason for Early Untethering

  • Kim, Kyung Hyun;Wang, Kyu-Chang;Lee, Ji Yeoun
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.3
    • /
    • pp.342-345
    • /
    • 2020
  • Some types of spinal dysraphism can be accompanied by extraspinal cysts, including myelomeningocele, myelocystocele, myelocele, meningocele, limited dorsal myeloschisis, lipomyelomeningocele, and terminal myelocystocele. Each disease is classified according to the developmental mechanism, embryologic process, site of occurrence, or internal structure of the extraspinal cyst. In most cystic spinal dysraphisms except meningocele, part of the spinal cord is attached to the cyst dome. Most open spinal dysraphisms pose a risk of infection and require urgent surgical intervention, but when the cyst is accompanied by closed spinal dysraphism, the timing of surgery may vary. However, if the extraspinal cyst grows, it aggravates tethering by pulling the tip of the cord, which is attached to the dome of the cyst. This causes neurological deficits, so urgent surgery is required to release the tethered cord.

Evaluation of Cancer Treatment Using FDG-PET (FDG-PET을 이용한 암 치료 효과의 평가)

  • Ryu, Jin-Sook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.1
    • /
    • pp.64-73
    • /
    • 2002
  • FDG-PET has potential as an effective, non-invasive tool to measure tumor response to anticancer therapy. The changes in tumor FDG uptake may provide an early, sensitive guide to the clinical and subclinical response of tumors to cancer treatment, as well as functional assessment of residual viable tumor. This may allow the evaluation of subclinical response to anticancer drugs in early clinical trials and improvements in patients management. However, monitoring tumor responses with FDG-PET is still in its infancy. The methods of measurement of FDG uptake are currently diverse and timing with respect to anti cancer therapy variable. Therefore, there is a need for larger-scale trials along with standardized methodology and a collection of reproducibility data. The recent guideline from the European group seems to be the most comprehensive. In future, the combination of morphological and metabolic images may improve the quantitative nature of these measurements by relating tumor viability to total tumor mass. More data on sensitivity and specificity of FDG-PET technique are needed along with continued advancement of PET methodology.

Structural Dashboard Design for Monitoring Job Performance of Internet Web Security Diagnosis Team: An Empirical Study of an IT Security Service Provider

  • Lee, Jung-Gyu;Jeong, Seung-Ryul
    • Journal of Internet Computing and Services
    • /
    • v.18 no.5
    • /
    • pp.113-121
    • /
    • 2017
  • Company A's core competency is IT internet security services. The Web diagnosis team analyzes the vulnerability of customer's internet web servers and provides remedy reports. Traditionally, Company A management has utilized a simple table format report for resource planning. But these reports do not notify the timing of human resource commitment. So, upper management asked its team leader to organize a task team and design a visual dashboard for decision making with the help of outside professional. The Task team selected the web security diagnosis practice process as a pilot and designed a dashboard for performance evaluation. A structural design process was implemented during the heuristic working process. Some KPI (key performance indicators) for checking the productivity of internet web security vulnerability reporting are recommended with the calculation logics. This paper will contribute for security service management to plan and address KPI design policy, target process selection, and KPI calculation logics with actual sample data.

Design and Implementation of UHF RFID Reader System Supporting Sensor Data Processing (센서 데이터 처리를 지원하는 UHF RFID 리더 시스템의 설계 및 구현)

  • Shin, Dong-Beom;Lee, Heyung-Sub;Choi, Gil-Young;Kim, Dae-Young
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.12A
    • /
    • pp.925-932
    • /
    • 2009
  • Precise temperature monitoring is the major preconditioning to supervise quality losses within the transport chain for fresh products. ISO/IEC18000-6REV1 defines new protocols supporting BAP(Battery Assisted Passive) RFID tag which is completely compatible with EPCglobal Class1 Generation2 specification. In this paper, we designed a modem supporting BAP RFID tag with FPGA(Field Programmable Gate Array) and implemented sensor data processing function defined in ISO/IEC18000-6REV1. The transmit block of the modem supports pulse shaping filter and the output signal of the implemented RFID reader is satisfied with the spectrum mask defined in the standard. The receive block of the modem uses Gardner TED to synchronize timing of symbol. In this paper, we designed a modem supporting ISO/IEC18000-6REV1 standard and developed a RFID reader sndard. The developed RFID reader sndard can recognize sensor tag and passive tag in the wireless environment and supports real-time processing of the sensor data in the embedded linux platform.

Multi-constellation Local-area Differential GNSS for Unmanned Explorations in the Polar Regions

  • Kim, Dongwoo;Kim, Minchan;Lee, Jinsil;Lee, Jiyun
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.8 no.2
    • /
    • pp.79-85
    • /
    • 2019
  • The mission tasks of polar exploration utilizing unmanned systems such as glacier monitoring, ecosystem research, and inland exploration have been expanded. To facilitate unmanned exploration mission tasks, precise and robust navigation systems are required. However, limitations on the utilization of satellite navigation system are present due to satellite orbital characteristics at the polar region located in a high latitude. The orbital inclination of global positioning system (GPS), which was developed to be utilized in mid-latitude sites, was designed at $55^{\circ}$. This means that as the user is located in higher latitudes, the satellite visibility and vertical precision become worse. In addition, the use of satellite-based wide-area augmentation system (SBAS) is also limited in higher latitude regions than the maximum latitude of signal reception by stationary satellites, which is $70^{\circ}$. This study proposes a local-area augmentation system that additionally utilizes Global Navigation Satellite System (GLONASS) considering satellite navigation system environment in Polar Regions. The orbital inclination of GLONASS is $64.8^{\circ}$, which is suitable in order to ensure satellite visibility in high-latitude regions. In contrast, GLONASS has different system operation elements such as configuration elements of navigation message and update cycle and has a statistically different signal error level around 4 m, which is larger than that of GPS. Thus, such system characteristics must be taken into consideration to ensure data integrity and monitor GLONASS signal fault. This study took GLONASS system characteristics and performance into consideration to improve previously developed fault detection algorithm in the local-area augmentation system based on GPS. In addition, real GNSS observation data were acquired from the receivers installed at the Antarctic King Sejong Station to analyze positioning accuracy and calculate test statistics of the fault monitors. Finally, this study analyzed the satellite visibility of GPS/GLONASS-based local-area augmentation system in Polar Regions and conducted performance evaluations through simulations.

Performance Assessment of GBAS Ephemeris Monitor for Wide Faults (Wide Fault에 대한 GBAS 궤도 오차 모니터 성능 분석)

  • Junesol Song;Carl Milner
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.13 no.2
    • /
    • pp.189-197
    • /
    • 2024
  • Galileo is a European Global Navigation Satellite System (GNSS) that has offered the Galileo Open Service since 2016. Consequently, the standardization of GNSS augmentation systems, such as Satellite Based Augmentation System (SBAS), Ground Based Augmentation System (GBAS), and Aircraft Based Augmentation System (ABAS) for Galileo signals, is ongoing. In 2023, the European Union Space Programme Agency (EUSPA) released prior probabilities of a satellite fault and a constellation fault for Galileo, which are 3×10-5 and 2×10-4 per hour, respectively. In particular, the prior probability of a Galileo constellation fault is significantly higher than that for the GPS constellation fault, which is defined as 1×10-8 per hour. This raised concerns about its potential impact on GBAS integrity monitoring. According to the Global Positioning System (GPS) Standard Positioning Service Performance Standard (SPS PS), a constellation fault is classified as a wide fault. A wide fault refers to a fault that affects more than two satellites due to a common cause. Such a fault can be caused by a failure in the Earth Orientation Parameter (EOP). The EOP is used when transforming the inertial axis, on which the orbit determination is based, to Earth Centered Earth Fixed (ECEF) axis, accounting for the irregularities in the rotation of the Earth. Therefore, a faulty EOP can introduce errors when computing a satellite position with respect to the ECEF axis. In GNSS, the ephemeris parameters are estimated based on the positions of satellites and are transmitted to navigation satellites. Subsequently, these ephemeris parameters are broadcasted via the navigation message to users. Therefore, a faulty EOP results in erroneous broadcast ephemeris data. In this paper, we assess the conventional ephemeris fault detection monitor currently employed in GBAS for wide faults, as current GBAS considers only single failure cases. In addition to the existing requirements defined in the standards on the Probability of Missed Detection (PMD), we derive a new PMD requirement tailored for a wide fault. The compliance of the current ephemeris monitor to the derived requirement is evaluated through a simulation. Our findings confirm that the conventional monitor meets the requirement even for wide fault scenarios.

Gated Conductivity Imaging using KHU Mark2 EIT System with Nano-web Fabric Electrode Interface (나노웹 섬유형 전극 인터페이스와 KHU Mark2 EIT 시스템을 이용한 생체신호 동기 도전율 영상법)

  • Kim, Tae-Eui;Kim, Hyun-Ji;Wi, Hun;Oh, Tong-In;Woo, Eung-Je
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.1
    • /
    • pp.39-46
    • /
    • 2012
  • Electrical impedance tomography(EIT) can produce functional images with conductivity distributions associated with physiological events such as cardiac and respiratory cycles. EIT has been proposed as a clinical imaging tool for the detection of stroke and breast cancer, pulmonary function monitoring, cardiac imaging and other clinical applications. However EIT still suffers from technical challenges such as the electrode interface, hardware limitations, lack of animal or human trials, and interpretation of conductivity variations in reconstructed images. We improved the KHU Mark2 EIT system by introducing an EIT electrode interface consisting of nano-web fabric electrodes and by adding a synchronized biosignal measurement system for gated conductivity imaging. ECG and respiration signals are collected to analyze the relationship between the changes in conductivity images and cardiac activity or respiration. The biosignal measurement system provides a trigger to the EIT system to commence imaging and the EIT system produces an output trigger. This EIT acquisition time trigger signal will also allow us to operate the EIT system synchronously with other clinical devices. This type of biosignal gated conductivity imaging enables capture of fast cardiac events and may also improve images and the signal-to-noise ratio (SNR) by using signal averaging methods at the same point in cardiac or respiration cycles. As an example we monitored the beat by beat cardiac-related change of conductivity in the EIT images obtained at a common state over multiple respiration cycles. We showed that the gated conductivity imaging method reveals cardiac perfusion changes in the heart region of the EIT images on a canine animal model. These changes appear to have the expected timing relationship to the ECG and ventilator settings that were used to control respiration. As EIT is radiation free and displays high timing resolution its ability to reveal perfusion changes may be of use in intensive care units for continuous monitoring of cardiopulmonary function.

A Nobel Video Quality Degradation Monitoring Schemes Over an IPTV Service with Packet Loss (IPTV 서비스에서 패킷손실에 의한 비디오품질 열화 모니터링 방법)

  • Kwon, Jae-Cheol;Oh, Seoung-Jun;Suh, Chang-Ryul;Chin, Young-Min
    • Journal of Broadcast Engineering
    • /
    • v.14 no.5
    • /
    • pp.573-588
    • /
    • 2009
  • In this paper, we propose a novel video quality degradation monitoring scheme titled VR-VQMS(Visual Rhythm based Video Quality Monitoring Scheme) over an IPTV service prone to packet losses during network transmission. Proposed scheme quantifies the amount of quality degradation due to packet losses, and can be classified into a RR(reduced-reference) based quality measurement scheme exploiting visual rhythm data of H.264-encoded video frames at a media server and reconstructed ones at an Set-top Box as feature information. Two scenarios, On-line and Off-line VR-VQMS, are proposed as the practical solutions. We define the NPSNR(Networked Peak-to-peak Signal-to-Noise Ratio) modified by the well-known PSNR as a new objective quality metric, and several additional objective and subjective metrics based on it to obtain the statistics on timing, duration, occurrence, and amount of quality degradation. Simulation results show that the proposed method closely approximates the results from 2D video frames and gives good estimation of subjective quality(i.e.,MOS(mean opinion score)) performed by 10 test observers. We expect that the proposed scheme can play a role as a practical solution to monitor the video quality experienced by individual customers in a commercial IPTV service, and be implemented as a small and light agent program running on a resource-limited set-top box.

Design of a XML-based Data Store Architecture for Run-time Process Monitor (실행시간 프로세스 모니터를 위한 XML 기반의 데이터 저장소의 설계)

  • Jeong, Yoon-Seok;Kim, Tae-Wan;Chang, Chun-Hyon
    • The KIPS Transactions:PartA
    • /
    • v.10A no.6
    • /
    • pp.715-722
    • /
    • 2003
  • Monitoring is used to see if a real-time system provides a service on time. The target of monitoring is not only an interior system but also a remote system which is located in the remote network. Monitoring needs data store to monitor data from each system. But a data store should be designed on the considerations of time constraints and data accessibility. In this paper, we present an architecture of XML-based data store and network delivery. XML-based data store is based on XML which is a standardized data format. So any platform which supports TCP/IP and HTTP can access data in the data store without any conversion. The XML-based delivery architecture is designed to reduce the time of data access and delivery. In addition, some experiments were tested to provide the timing guideline to be kept by a real-time system which uses the architecture presented in this paper. The architecture of XML-based data store and delivery designed in this paper can be used in the domains of remote real-time monitoring and control.

Measurement of Reference Phase Offset for the Loran-C Transmitting Signal of Pohang (포항 로란-C 송신 신호의 기준위상 오프셋 측정)

  • Lee, Chang-Bok;Won, Sung-Ho;Lee, Jong-Koo;Kim, Young-Jae;Lee, Sang-Jeong;Yang, Sung-Hoon
    • Journal of Navigation and Port Research
    • /
    • v.36 no.6
    • /
    • pp.475-480
    • /
    • 2012
  • In order to establish eLoran (enhanced Long Range Navigation) system, it needs the advancement of receiver, transmitter, data channel addition for Loran information, differential Loran sites for compensating Loran-c signal and ASFs (Additional Secondary Factors) database, etc. In addition, the precise synchronization of transmitting station to the UTC (Coordinated Universal Time) is essential if Loran delivers the high absolute accuracy of navigation demanded for maritime harbor entrance. For better timing synchronization to the UTC among transmitting stations, it is necessary to measure and monitor the transmission delay of the station, and the correction information of the transmitting station should be provided to the user's receivers. In this paper we presented the measurement method of absolute delay of Pohang Loran transmitting station and developed a time delay measurement system and a phase monitoring system for Loran station. We achieved -2.23 us as a result of the absolute phase delay of Pohang station and the drift of Loran pulse of the station was measured about 0.3 us for a month period. Therefore it is necessary to measure the delay offset of transmitting station and to compensate the drift of the Loran signal for the high accuracy application of PNT (Positioning, Navigation and Timing).