• Title/Summary/Keyword: Time zero

Search Result 1,775, Processing Time 0.038 seconds

Changes in the Luminal Surface of the PTFE Graft used in Systemic- pulmonary Shunt Operation (체폐단락술에 사용되었던 PTFE 인조혈관 내면의 변화)

  • Park, Yeong-Hwan;Jang, Byeong-Cheol;Sin, Dong-Hwan;Jo, Beom-Gu
    • Journal of Chest Surgery
    • /
    • v.29 no.8
    • /
    • pp.836-843
    • /
    • 1996
  • Histologic, and scanning electron microscopic observa ions were made of 12 biopsy specimens from polytetrdiluoroethylene (PTFE) grafts that had been Implanted as systemic-pulmonAry shunt for improving oxygenation of cyanotic congenital heart disease and harvested near the end of pulmonary artery side at the time of redo shunt or tonal correction between 1985 and 1992. The types of shunt operation are modified Blalock-Taussig shunt in 10 cases, Waterston-Cooley shunt in 1 And Potts shunt in 1 case. The 5 mm PTFE graft was used In 10, 4mm in 1 and 6mm in 1 case. The mean duration of implantalion was 0 $\pm$ 14.1 months(rl.on 12 months to 55 months). The plAtelets were aggregated between gaps'of Coretex surface and intimal thickening was noted about 10 to 20 months after implantation. Endothelial cells were found in the 40-months patent PTFE graft by light and scanning electron microscopy. In the specimen of poor flow or zero flow graft, severe intimal hyperplasia and thrombi which was made of platelets were noted . Based on this experience, we think that the patency will be maintained well if the connective tissue could be Hxed firmly over the Inner layer of the Goretex and the endothelial cell layer sllould form over the con- nective tissue and platelet aggregation should be prevented.

  • PDF

Flotation Characteristics of Malachite by Various Collectors (포수제(捕收劑) 종류(種類)에 따른 공작석(孔雀石)의 부유선별(浮遊選別) 특성(特性))

  • Kim, Hyung-Seok;Kim, Wan-Tae;Han, In-Kyu;Kim, Sang-Bae
    • Resources Recycling
    • /
    • v.19 no.4
    • /
    • pp.58-64
    • /
    • 2010
  • In order to select the proper collector for the flotation of malachite, we had floated malachite by using various collectors. When measuring the zeta potential of malachite, we knew that the point of zero charge of malachite is found at pH 8.2 and malachite particles are negatively charged above this pH value; and positively, below this pH value. The floatability of malachite by the anionic collectors like sodium oleate and Aeropromoter 845, was about 97% in pH 5~11 range, whereas that of malachite by alkyl hydroxamate and the cationic collector like dodecyl trimethyl ammonium chloride and dodecyl ethyl methyl ammonium chloride, was below 15% above pH 5 regardless of dosage increase of collector and flotation time. The malachite sulphidised by $(NH_4)_2S$ was floated above 97% by potassium amyl xanthate. The dosage of potassium amyl xanthate decreased and the flotation period shortened to one third than when it was not sulphidised by $(NH_4)_2S$. Therefore, potassium amyl xanthate and the anionic collectors like sodium oleate and Aeropromoter 845 can be used as the collector of malachite.

Geopotentinl Field in Nonlinear Balance with the Sectoral Mode of Rossby-Haurwitz Wave on the Inclined Rotation Axis (섹터모드의 로스비하우어비츠 파동과 균형을 이루는 고도장)

  • Cheong, Hyeong-Bin;Park, Ja-Rin
    • Journal of the Korean earth science society
    • /
    • v.28 no.7
    • /
    • pp.936-946
    • /
    • 2007
  • Analytical geopotential field in balance with the sectoral mode (the first symmetric mode with respect to the equator) of the Rossby-Haurwitz wave on the inclined rotation axis was derived in presence of superrotation background flow. The balanced field was obtained by inverting the divergence equation with the time derivative being zero. The inversion consists of two steps, i.e., the evaluation of nonlinear forcing terms and the finding of analytical solutions based on the Poisson's equation. In the second step, the forcing terms in the from of Legendre function were readily inverted due to the fact that Legendre function is the eigenfunction of the spherical Laplacian operator, while other terms were solved either by introducing a trial function or by integrating the Legendre equation. The balanced field was found to be expressed with six zonal wavenumber components, and shown to be of asymmetric structure about the equator. In association with asymmetricity, the advantageous point of the balanced field as a validation method for the numerical model was addressed. In special cases where the strength of the background flow is a half of or exactly the same as the rotation rate of the Earth it was revealed that one of the zonal wavenumber components vanishes. The analytical balanced field was compared with the geopotential field which was obtained using a spherical harmonics spectral model. It was found that the normalized difference lied in the order of machine rounding, indicating the reliability of the analytical results. The stability of the sectoral mode of Rossby-Haurwitz wave and the associated balanced field was discussed, comparing with the flrst antisymmetric mode.

Basic Analysis of Heat and Mass Transfer Characteristics of Tubular Membrane Humidifier for Proton Exchange Membrane Fuel Cell (이온교환막 연료전지용 원통형 막 가습기의 열 및 물질전달특성 기초 연구)

  • Bae, Ho-June;Ahn, Kook-Young;Lee, Young-Duk;Kang, Sang-Kyu;Yu, Sang-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.5
    • /
    • pp.473-480
    • /
    • 2011
  • The proton exchange membrane (PEM) fuel cell system is critically dependent on the humidity, which should be properly maintained over the entire operating range. A membrane humidifier is used for the water management in the PEMFC because of the membrane humidifier's reliable performance and zero parasitic power loss. In the PEMFC system, the membrane humidifier is required to provide appropriate humidity for the design point of the fuel cell. Although the performance of the fuel cell depends on the performance of the humidifier, few studies have provided a systematic analysis of the humidifier. We carry out an experimental analysis of the membrane humidifier using a vapor condensation bottle. The dry air pressure, water flow temperature, and air flow rate were chosen as the operating parameters. The results show that the time constant for the dynamic response of the membrane humidifier is relatively short, but additional analysis should be carried out.

Physiological Function in vitro of Biopolymer from Bacillus coagulans CE-74 (Bacillus coagulans CE-74에 의해 생산된 Biopolymer의 생리적 기능성)

  • Lee, Seon-Ho;Choi, Hee-Jin;Son, Jun-Ho;Bae, Du-Kyung;Bae, Jong-Ho;Kim, Sung;An, Bong-Jeon;Choi, Cheong
    • Applied Biological Chemistry
    • /
    • v.44 no.3
    • /
    • pp.137-142
    • /
    • 2001
  • In order to prove physiological function of biopolymer from Bacillus coagulans CE-74, in vitro experiments simulating the passive membrane transport of gastrointestinal tract were carried out using dialysis membrane. And inhibition effect of isolated biopolymer on tyrosinase and angiotensin converting enzyme (ACE) were observed. The glucose retardation index after 30 min dialysis was 43.5% in the presence of 2% biopolymer. As the dialysis period became longer, the retarding effect toward glucose absorption decreased and the effect was close to zero after 5 hr dialysis. The bile acid retardation index after 30 min dialysis was 34% and 44.2% in the presence of 1% and 2% biopolymer, respectively. The effect decreased as the dialysis time elapsed. It was measured by arosinase inhibition activity of biopolymer that inhibition effect was 48.5% in $20\;{\mu}g/{\mu}l$. In a ACE inhibition activity, biopolymer showed inhibition activity as 97% in $10\;{\mu}g/{\mu}l$.

  • PDF

Detection of Abnormal Area of Ground in Urban Area by Rectification of Ground Penetrating Radar Signal (지하투과레이더 신호의 보정을 통한 도심지 내 지반 이상구간의 검측)

  • Kang, Seonghun;Lee, Jong-Sub;Lee, Sung Jin;Lee, Jin Wook;Hong, Won-Taek
    • The Journal of Engineering Geology
    • /
    • v.27 no.3
    • /
    • pp.217-231
    • /
    • 2017
  • The subsidence of ground in urban area can be caused by the occurrence of the cavity and the change in ground volumetric water content. The objective of this study is the detection of abnormal area of ground in urban area where the cavity or the change in ground volumetric water content is occurred by the ground penetrating radar signal. GPR survey is carried out on the test bed with a circular buried object. From the GPR survey, the signals filtered by the bandpass filtering are measured, and the methods consisting of gain function, time zero, background removal, deconvolution and display gain are applied to the filtered signals. As a result of application of the signal processing methods, the polarity of signal corresponds with the relation of electrical impedance of the cavity and the ground in test bed. In addition, the relative permittivity calculated by GPR signal is compared with that of predicted by volumetric water content of the test bed. The relative permittivities obtained from two different methods show similar values. Therefore, the abnormal area where the change in ground volumetric water content is occurred can be detected from the results of the GPR survey in case the depth of underground utilities is known. Signal processing methods and estimation of relative permittivity performed in this study may be effectively used to detect the abnormal area of ground in urban area.

Dietary Protein Sources Affect Internal Quality of Raw and Cooked Shell Eggs under Refrigerated Conditions

  • Wang, X.C.;Zhang, H.J.;Wu, S.G.;Yue, H.Y.;Wang, J.;Li, Jie;Qi, Guang-Hai
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.28 no.11
    • /
    • pp.1641-1648
    • /
    • 2015
  • This study was conducted to evaluate the effects of various protein sources (soybean meal, SBM; cottonseed protein, CSP; double-zero rapeseed meal, DRM) on the internal quality of refrigerated eggs. A total of 360 laying hens (32 wk of age) were randomly allotted to six treatment groups (five replicates per treatment) and fed diets containing SBM, CSP, or DRM individually or in combination with equal crude protein content (SBM-CSP, SBM-DRM, and CSP-DRM) as the protein ingredient(s). A $6{\times}3$ factorial arrangement was employed with dietary types and storage time (0 d, 2 wk, and 4 wk) as the main effects. After 12 wk of diet feeding, a total of 270 eggs were collected for egg quality determination. The egg Haugh unit (HU) in the CSP, SBM-DRM, and DRM groups were significantly lower than those in the SBM and SBM-CSP groups. The hardness and springiness of the cooked yolk in the CSP group were significantly higher than those in the other treatment groups. A lower HU, lower yolk index and higher albumen pH were observed in the DRM group compared to the SBM and SBM-CSP groups when the eggs were stored to 4 wk, and the HU was improved in the CSP-DRM group compared to the DRM group (p<0.05). Higher yolk hardness was observed in the CSP group compared to the other groups during storage (p<0.05), but the hardness of the cooked yolk in the SBM-CSP and CSP-DRM groups showed no difference in comparison to the SBM group. In conclusion, CSP may ameliorate the negative effects of DRM on the HU of refrigerated eggs, and SBM or DRM may alleviate the adverse effects of CSP on yolk hardness.

Technology Analysis on Automatic Detection and Defense of SW Vulnerabilities (SW 보안 취약점 자동 탐색 및 대응 기술 분석)

  • Oh, Sang-Hwan;Kim, Tae-Eun;Kim, HwanKuk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.94-103
    • /
    • 2017
  • As automatic hacking tools and techniques have been improved, the number of new vulnerabilities has increased. The CVE registered from 2010 to 2015 numbered about 80,000, and it is expected that more vulnerabilities will be reported. In most cases, patching a vulnerability depends on the developers' capability, and most patching techniques are based on manual analysis, which requires nine months, on average. The techniques are composed of finding the vulnerability, conducting the analysis based on the source code, and writing new code for the patch. Zero-day is critical because the time gap between the first discovery and taking action is too long, as mentioned. To solve the problem, techniques for automatically detecting and analyzing software (SW) vulnerabilities have been proposed recently. Cyber Grand Challenge (CGC) held in 2016 was the first competition to create automatic defensive systems capable of reasoning over flaws in binary and formulating patches without experts' direct analysis. Darktrace and Cylance are similar projects for managing SW automatically with artificial intelligence and machine learning. Though many foreign commercial institutions and academies run their projects for automatic binary analysis, the domestic level of technology is much lower. This paper is to study developing automatic detection of SW vulnerabilities and defenses against them. We analyzed and compared relative works and tools as additional elements, and optimal techniques for automatic analysis are suggested.

Development of Algorithm and Program for the Ground Fault Detection in Ungrounded Distribution Power System (비접지 배전계통 지락고장 검출 알고리즘 및 프로그램 개발)

  • Park, So-Young;Shin, Chang-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.10
    • /
    • pp.2619-2627
    • /
    • 2009
  • The ground fault is occupying 70% among the total number of faults in ungrounded distribution power system. When the ground fault occurs in ungrounded system, the fault current is so small that it is hard to detect. But fault handling is very important because to continue power supply during fault conditions may cause the fault spreading and the distribution device in trouble. This paper presents the fault line detection method by using GPT signal detecting zero sequence voltage, and the fault section detection method by detecting whether GPT signal is disappeared or not during shifting normally open switch, which is connecting switch between distribution lines with open state in order to restore the outage area under emergency situation, and during isolating each section one by one which belongs to the fault line. This method is efficient because there is no whole power interruption during the fault section detection, and it is possible to perform both the fault section detection and the service restoration for the outage area at the same time, and it can apply to various distribution system configuration. Program for the fault restoration was developed applying proposed method, and it has been validated by applying to the pilot project of distribution automation system in Vietnam which has the ungrounded distribution system.

A Study on the Payment Mechanism of Independent Guarantee -focusing on matters that the relevant parties involved should know- (청구보증상 지급메커니즘에 따른 실무상 유의점)

  • Oh, Won-Suk;Kim, Pil-Joon;Lee, Woon-Chang
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.46
    • /
    • pp.133-158
    • /
    • 2010
  • Independent guarantee is a creation of the need from the both sides, i.e. the applicant (principal debtor) and the beneficiary (creditor). The former used to have to deposit cash in favor of the beneficiary in case of his default, which laid a burden on his liquidity while the latter still wanted to have the equivalent to cash. Independent guarantee satisfied the both parties by freeing the applicant of a deposit and maintaining the beneficiary's right at the same time. The fact that independent guarantee has three payment mechanisms is not widely known to the public. They are (i) payment on first demand, (ii) payment upon submission of third-party documents, (iii) payment upon submission of an arbitral or court decision. From the applicant's point of view, the order in his favor is (iii), followed by (ii) and (i). As there shouldn't be a case where one party is at a disadvantage against the other, useful insight is being sought for the benefit of the applicant. First, the applicant can offer his intention to provide a payment mechanism (ii) or (iii) rather than (i) if he must deliver it. Second, if the beneficiary still wants to have (i) and the applicant is in a position not to reject it, the latter should thoroughly check any provisions that may work against him later. Third, the applicant could use counterbalancing provisions in underlying contract to cope with protective clauses in the guarantees. Forth, the applicant should review the beneficiary's sincerity to prevent unfair calling risks. The applicant may use an ECA(Export Credit Agency) in his country to which he can transfer not only unfair calling risks, but also political risks. On the other hand, a bank needs to keep the following advice in mind. The foremost important thing for the bank not to forget is that it provides a guarantee as a service provider, not as a responsible party for the feasibility of the project, etc. Credit risk of the applicant should require the greatest attention when issuing a guarantee: the bank should look into the possibility that it can procure immediate reimbursement from its customers after payment to the beneficiary. Second, the applicant's ability to complete the project should be reviewed by checking its track records, techniques and reputation, etc. Third, the bank may also use an ECA to cover the beneficiary's unfair calling risks as well as political risks. In the case of Korea, as Korea Export Insurance Corporation(KEIC) can cover all the risks mentioned above, the bank could use its service called 'Export Bond Insurance.' What's better for the bank is that ECA cover can enhance the bank's asset quality by putting it zero on its risk weighted asset.

  • PDF