• Title/Summary/Keyword: Time slice

Search Result 238, Processing Time 0.032 seconds

DAMGO modulates two-pore domain K+ channels in the substantia gelatinosa neurons of rat spinal cord

  • Cho, Pyung Sun;Lee, Han Kyu;Lee, Sang Hoon;Im, Jay Zoon;Jung, Sung Jun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.20 no.5
    • /
    • pp.525-531
    • /
    • 2016
  • The analgesic mechanism of opioids is known to decrease the excitability of substantia gelatinosa (SG) neurons receiving the synaptic inputs from primary nociceptive afferent fiber by increasing inwardly rectifying $K^+$ current. In this study, we examined whether a ${\mu}$-opioid agonist, [D-Ala2,N-Me-Phe4, Gly5-ol]-enkephalin (DAMGO), affects the two-pore domain $K^+$ channel (K2P) current in rat SG neurons using a slice whole-cell patch clamp technique. Also we confirmed which subtypes of K2P channels were associated with DAMGO-induced currents, measuring the expression of K2P channel in whole spinal cord and SG region. DAMGO caused a robust hyperpolarization and outward current in the SG neurons, which developed almost instantaneously and did not show any time-dependent inactivation. Half of the SG neurons exhibited a linear I~V relationship of the DAMGO-induced current, whereas rest of the neurons displayed inward rectification. In SG neurons with a linear I~V relationship of DAMGO-induced current, the reversal potential was close to the $K^+$ equilibrium potentials. The mRNA expression of TWIK (tandem of pore domains in a weak inwardly rectifying $K^+$ channel) related acid-sensitive $K^+$ channel (TASK) 1 and 3 was found in the SG region and a low pH (6.4) significantly blocked the DAMGO-induced $K^+$ current. Taken together, the DAMGO-induced hyperpolarization at resting membrane potential and subsequent decrease in excitability of SG neurons can be carried by the two-pore domain $K^+$ channel (TASK1 and 3) in addition to inwardly rectifying $K^+$ channel.

Characterization of Cone-beam Computed Tomography System for Small Animal (콘빔형 소동물용 전산화단층촬영(CT) 장치의 성능평가)

  • Kang, Hyeong-Geun;Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.1
    • /
    • pp.19-24
    • /
    • 2010
  • A cone-beam computed tomography (CT) system for a small animal has been widely used in the bio-medical application. This paper introduced simple methods for evaluating a cone-beam CT system using a simple tungsten wire phantom of 10{$\mu}m$ diameter and a water phantom. Slice images and three-dimensional tomography images were obtained through 360 projection views per one sample rotation under stable X-ray tube conditions for a long running time. The cone-beam CT system at a position of a 1.07 magnification showed a spatial frequency of 13.78 lp/mm ($36.2{\mu}m$ spatial resolution) and gave a CNR of 10.33 and a S/N of 5.87 under a tube voltage of 80kV.

MR Angiography with Simultaneous Data Acquisition of Arteries and Veins(SAAV) Method and Artery-Vein Color Mapping in 0.3T MRI System (0.3T MRI 시스템에서의 동.정맥 동시 획득을 위한 자기공명 혈류 영상 기법(SAAV)과 동.정맥 color mapping)

  • 조종운;조지연;서성만;은충기;문치웅
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.275-280
    • /
    • 2003
  • The method of simultaneous data acquisition of arteries and veins(SAAV) was suggested to obtain MR angiography of arteries and veins at 0.3T low filed MRI system (Magfinder, AlLab. Korea). Two separated artery- and vein-images were put together using AVCM(Artery-Vein Color Mapping) algorithm and presented in the same image. In this study, artery- and vein-separated angiograms of volunteer's neck were obtained. Two dimensioal blood-enhanced images wre sequentially obtained using SAAV pulse sequence based on time-of-flight(TOF) method with flow compensation. Imaging parameters were TR/TE=70/12msec. FOV=230mm, slice thickness = 3mm, flip angle=90$^{\circ}$, matrix size=256${\times}$256${\times}$64mm. TSat TH/SPA=15/20mm, Ts_v=10msec and Ts_a=40ms. 3D MRA images were reconstructed using the maximum intensity projection(MIP) and the artery-vein color mapping(AVCM) algorithm. This study showed good possibility of clinical applications of MRA in 0.3T which provides valuable diagnostic information of clinical vascular diseases.

A Group Update Technique based on a Buffer Node to Store a Vehicle Location Information (차량 위치 정보 저장을 위한 버퍼 노드 기반 그룹 갱신 기법)

  • Jung, Young-Jin;Ryu, Keun-Ho
    • Journal of KIISE:Databases
    • /
    • v.33 no.1
    • /
    • pp.1-11
    • /
    • 2006
  • It is possible to track the moving vehicle as well as to develop the location based services actively according to the progress of wireless telecommunication and GPS, to the spread of network, and to the miniaturization of cellular phone. To provide these location based services, it is necessary for an index technique to store and search too much moving object data rapidly. However the existing indices require a lot of costs to insert the data because they store every position data into the index directly. To solve this problem in this paper, we propose a buffer node operation and design a GU-tree(Group Update tree). The proposed buffer node method reduces the input cost effectively since the operation stores the moving object location data in a group, the buffer node as the unit of a non-leaf node. hnd then we confirm the effect of the buffer node operation which reduces the insert cost and increase the search performance in a time slice query from the experiment to compare the operation with some existing indices. The proposed tufter node operation would be useful in the environment to update locations frequently such as a transportation vehicle management and a tour-guide system.

Encryption of MPEG using Error Propagation by a Receiver (수신단에서 에러 전파 특성을 이용한 MPEG 암호화)

  • Jeong, Seo-Hyun;Lee, Sung-Ju;Chung, Young-Wha;Kim, Sang-Chun;Min, Byoung-Ki
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.21 no.3
    • /
    • pp.183-188
    • /
    • 2011
  • According to increased multimedia data(i.e., MPEG video stream) in mobile application, protecting data becomes an important problem in the multimedia data delivery. SECMPEG is a selective encryption approach for protecting multimedia data. However, the computational overhead of SECMPEG's security level 3 is quite large because it encrypts the whole I-frames whose size is relatively larger than P/B-frames. Therefore, we need to analyze the characteristics of MPEG2 standard and derive an effective encryption of the I-frames. In this paper, we propose a slice-level, selective encryption approach by using the error-propagation characteristics of I-frames by a receiver. Our experimental results show that the proposed approach can reduce the execution time of SECMPEG's security level 3 by a factor of 30 without degradation of the security.

Development of Biopsy Assist Device on Computed Tomography Using 3D Printing Technology (3D 프린팅 기술을 이용한 전산화단층영상 기반 조직 생검 보조기구 개발)

  • Jeong-Wan Kim;Youl-Hun Seoung
    • Journal of radiological science and technology
    • /
    • v.46 no.2
    • /
    • pp.151-157
    • /
    • 2023
  • The purpose of this study was to develop an assist device that could correct and support patient position during biopsy on computed tomography (CT) using 3D printing technology. The development method was conducted in the order of 3D design, 3D output, intermediate evaluation for product, final assist device evaluation. The 3D design method was conducted in the order of prior research data survey, measurement, primary modeling, 3D printing, output evaluation, and supplementary modeling. The 3D output was the 3D printer (3DWOX 2X, Sindoh, Korea) with additive manufacturing technology and the polylactic acid (PLA) materials. At this time, the optimal strength was evaluated to infill degree of product as the 3D printing factors into 20%, 40%, 60%, and 80%. The intermediate evaluation and supplementation was measured noise in the region of interest (ROI) around the beam hardening artifact on the CT images. We used 128-channel MDCT (Discovery 75 HD, GE, USA) to scan with a slice thickness of 100 kVp, 150 mA, and 2.5 mm on the 3D printing product. We compared the surrounding noise of the final 3D printing product with the beginning of it. and then the strength of it according to the degree of infill was evaluated. As a result, the surrounding noise of the final and the early devices were measured at an average of 3.3 ± 0.5 HU and 7.1 ± 0.1 HU, respectively, which significantly reduced the noise of the final 3D printing product (p<0.001). We found that the percentage of infill according to the optimal strength was found to be 60%. Finally, development of assist devices for CT biopsy will be able to minimize artifacts and provide convenience to medical staff and patients.

Optimizations of 3D MRI Techniques in Brain by Evaluating SENSE Factors (삼차원 자기공명영상법의 뇌 구조 영상을 위한 최적화 연구: 센스인자 변화에 따른 신호변화 평가)

  • Park, Myung-Hwan;Lee, Jin-Wan;Lee, Kang-Won;Ryu, Chang-Woo;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.161-170
    • /
    • 2009
  • Purpose : A parallel imaging method provides us to improve temporal resolution to obtain three-dimensional (3D) MR images. The objective of this study was to optimize three 3D MRI techniques by adjusting 2D SESNE factors of the parallel imaging method in phantom and human brain. Materials and Methods : With a 3 Tesla MRI system and an 8-channel phase-array sensitivity-encoding (SENSE) coil, three 3D MRI techniques of 3D T1-weighted imaging (3D T1WI), 3D T2-weighted imaging (3D T2WI) and 3D fluid attenuated inversion recovery (3D FLAIR) imaging were optimized with adjusting SESNE factors in a water phantom and three human brains. The 2D SENSE factor was applied on the phase-encoding and the slice-encoding directions. Signal-to-noise ratio(SNR), percent signal reduction rate(%R), and contrast-to-noise ratio(CNR) were calculated by using signal intensities obtained in specific regions-of-interest (ROI). Results : In the phantom study, SENSE factor = 3 was provided in 0.2% reduction of signals against without using SENSE with imaging within 5 minutes for 3D T1WI. SENSE factor = 2 was provided in 0.98% signal reduction against without using SENSE with imaging within 5 minutes for 3D T2WI. SENSE factor = 4 was provided in 0.2% signal reduction against without using SENSE with imaging around 6 minutes for 3D FLAIR. In the human brain study, SNR and CNR were higher with SENSE factors = 3 than 4 for all three imaging techniques. Conclusion : This study was performed to optimize 2D SENSE factors in the three 3D MRI techniques that can be scanned in clinical time limitations with minimizing SNR reductions. Without compromising SNR and CNR, the optimum 2D SENSE factors were 3 and 4, yielding the scan time of about 5 to 6 minutes. Further studies are necessary to optimize 3D MRI techniques in other areas in human body.

  • PDF

The Clinical Outcomes of Off-Pump Coronary Artery Bypass Grafting in the Octogenarians (80세 이상 고령 환자에서 심폐바이패스 없이 시행한 관상동맥우회술의 중단기 성적)

  • Kim Do-Kyun;Lee Chang Young;Lee Kyo Joon;Joo Hyun Chul;Yoo Kyung-Jong
    • Journal of Chest Surgery
    • /
    • v.38 no.10 s.255
    • /
    • pp.680-684
    • /
    • 2005
  • Background: With the increasing age of the population, coronary artery bypass grafting in the elderly patients is becoming common. Off-pump coronary artery bypass grafting (OPCAB) has been proven to be less morbidity and to facilitate early recovery. The elderly patients may have benefits by avoiding the adverse effects of the cardiopulmonary bypass. The purpose of this study is to evaluate our results of OPCAB in elderly patients. Material and Method: A retrospective chart review was carried out for 12 patients aged over 80 years who underwent isolated OPCAB from January 2001 and March 2004. Data were collected risk factors for disease, extent of coronary disease, and in-hospital outcomes. Postoperative graft patiency was evaluated in 9 patients by multi-slice computed tomography. Result: Eleven patients had triple vessel disease or left main disease. Four patients were suffered from preoperative CVA, and 4 patients had chronic obstructive pulmonary disease. Two patients had myocardial infarction (MI), among them 1 patient was suffered from pulmonary edema after preoperative MI. There was no perioperative death, perioperative MI, and no ventricular arrhythmia. Also there was no perioperative stroke and renal failure. But there was one deep sternal infection who recovered by treating of muscle flap. Atrial fibrillation was newly developed in 1 patient, but was well controlled by medication. Mean intubation time was $15.9\pm4.4(8\~20hrs)$ hrs and mean ICU stay was $2.9\pm0.8(2\~4 days)$ days. Mean hospital day was $21.6\pm14.3(13\~56 days)$ days. Postoperative mean CK-MS was $11.3\pm14.1\;ng/mL$. Early postoperative graft patency rate was $100\%(24/24)$. Follow-up was completed in all patients. In this time, there was no patients with angina or death. Conclusion: The results of this study suggest that OPCAB reduces morbidity and favors hospital outcomes. Therefore, OPCAB is safe, reasonable and might be preferable operative strategy in elderly patients.

Flip Angle of the Optimal T1 Effect Using FLASH Pulse Sequence at 3T Abdominal MRI (FLASH를 이용한 3T 복부검사에 있어서 최적의 T1효과를 위한 적정 Flip Angle)

  • Han, Jae-Bok;Choi, Nam-Gil
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.101-106
    • /
    • 2009
  • Purpose of this study is to compare the signal intensity (SI) and CNR with T1 weighted image using FLASH at 3T abdominal MRI by varying flip angle (FA). Totally 20 patients (male : 12, female : 8, Age : $28{\sim}63$ years with mean : 51) were examined by 3 Tesla MR scanner (Magnetom Tim Trio, SIEMENS, Germany) with 8 channel body array coil between september and October 2008. Imaging parameters were as follows : FLASH sequence, TR : 120 ms, TE : minimum, FOV (field of view) : $360{\times}300\;mm$, Matrix : $256{\times}224$, slice : 6 mm, scan time : 15 sec and Breath-hold technique. Abdominal image, with a 50 ml syringe filled with water placed in the FOV measuring the water signal, were acquired with varying FA through $10^{\circ}$ to $90^{\circ}$ with $10^{\circ}$ interval. SI's were measured three times at liver parenchyme, water, spleen and background and averaged. The CNR's were measured between the ROIs (region of interest). Statistic analysis was performed with ANOVA test using SPSS software (version 17.0). Less than FA $30^{\circ}$, abdominal images were severely inhomogeneity. Especially, T1 effect of water signal was weak. As the flip angle increased, the signal intensity decreased at all the regions. Especially, flip angle of the highest signal intensity was observed with $40^{\circ}$ at the liver parenchyme, $20^{\circ}$ at water, $30^{\circ}$ at the spleen, respectively. The CNR between liver and water was -60.92 at FA $10^{\circ}$ and 15.16 at FA $80^{\circ}$. The CNR between liver and spleen was -3.18 at FA $10^{\circ}$ and 9.65 at $80^{\circ}$. In conclusion, FA $80^{\circ}$ is optimal for T1 weighted effect using FLASH pulse sequence at 3.0 T abdominal MRI.

  • PDF

Reducing of Craniofacial Radiation Dose Using Automatic Exposure Control Technique in the 64 Multi-Detector Computed Tomography (64 다중 검출기 전산화단층촬영에서 관전류 자동노출조절 기법을 이용한 두개부 방사선량 감소 정도 평가)

  • Seoung, Youl-Hun;Kim, Yong-Ok;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.137-144
    • /
    • 2010
  • The purpose of this study was to evaluate the usefulness of reducing of craniofacial radiation dose using automatic exposure control (AEC) technique in the 64 multi-detector computed tomography (MDCT). We used SOMATOM Definition 64 multi-detector CT, and head of whole body phantom (KUPBU-50, Kyoto Kagaku CO. Ltd). The protocol were helical scan method with 120 kVp, 1 sec of rotation time, 5 mm of slice thickness and increment, 250 mm of FOV, $512{\times}512$ of matrix size, $64{\times}0.625\;mm$ of collimation, and 1 of pitch. The evaluation of dose reducing effect was compared the fixed tube current of 350 with AEC technique. The image quality was measured the noise using standard deviation of CT number. The range of craniofacial bone was to mentum end from calvaria apex, which devided three regions: calvaria~superciliary ridge (1 segment), superciliary ridge~acanthion (2 segment), and acanthion~mentum (3 segment). In the fixed tube current technique, CTDIvol was 57.7 mGy, DLP was $640.2\;mGy{\cdot}cm$ in the all regions. The AEC technique was showed that 1 segment were 30.7 mGy of CTDIvol, 340.7 $mGy{\cdot}cm$ of DLP, 2 segment were 46.5 mGy of CTDIvol, $515.0\;mGy{\cdot}cm$ of DLP, and 3 segment were 30.3 mGy of CTDIvol, $337.0\;mGy{\cdot}cm$ of DLP. The standard deviation of CT number was 2.622 with the fixed tube current technique and 3.023 with the AEC technique in the 1 segment, was 3.118 with the fixed tube current technique and 3.379 with the AEC technique in the 2 segment, was 2.670 with the fixed tube current technique and 3.186 with the AEC technique in the 3 segment. The craniofacial radiation dose using AEC Technique in the 64 MDCT was evaluated the usefulness of reducing for the eye, the parotid and thyroid with high radiation sensitivity particularly.