• Title/Summary/Keyword: Time progress

Search Result 2,177, Processing Time 0.028 seconds

Image-based Absorbed Dosimetry of Radioisotope (영상기반 방사성동위원소 흡수선량 평가)

  • Park, Yong Sung;Lee, Yong Jin;Kim, Wook;Ji, Young Hoon;Kim, Kum Bae;Kang, Joo Hyun;Lim, Sang Moo;Woo, Sang-Keun
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.86-92
    • /
    • 2016
  • An absorbed dose calculation method using a digital phantom is implemented in normal organs. This method cannot be employed for calculating the absorbed dose of tumor. In this study, we measure the S-value for calculating the absorbed dose of each organ and tumor. We inject a radioisotope into a torso phantom and perform Monte Carlo simulation based on the CT data. The torso phantom has lung, liver, spinal, cylinder, and tumor simulated using a spherical phantom. The radioactivity of the actual absorbed dose is measured using the injected dose of the radioisotope, which is Cu-64 73.85 MBq, and detected using a glass dosimeter in the torso phantom. To perform the Monte Carlo simulation, the information on each organ and tumor acquired using the PET/CT and CT data provides anatomical information. The anatomical information is offered above mean value and manually segmented for each organ and tumor. The residence time of the radioisotope in each organ and tumor is calculated using the time activity curve of Cu-64 radioactivity. The S-values of each organ and tumor are calculated based on the Monte Carlo simulation data using the spatial coordinate, voxel size, and density information. The absorbed dose is evaluated using that obtained through the Monte Carlo simulation and the S-value and the residence time in each organ and tumor. The absorbed dose in liver, tumor1, and tumor2 is 4.52E-02, 4.61E-02, and 5.98E-02 mGy/MBq, respectively. The difference in the absorbed dose measured using the glass dosimeter and that obtained through the Monte Carlo simulation data is within 12.3%. The result of this study is that the absorbed dose obtained using an image can evaluate each difference region and size of a region of interest.

Prediction of Target Motion Using Neural Network for 4-dimensional Radiation Therapy (신경회로망을 이용한 4차원 방사선치료에서의 조사 표적 움직임 예측)

  • Lee, Sang-Kyung;Kim, Yong-Nam;Park, Kyung-Ran;Jeong, Kyeong-Keun;Lee, Chang-Geol;Lee, Ik-Jae;Seong, Jin-Sil;Choi, Won-Hoon;Chung, Yoon-Sun;Park, Sung-Ho
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.132-138
    • /
    • 2009
  • Studies on target motion in 4-dimensional radiotherapy are being world-widely conducted to enhance treatment record and protection of normal organs. Prediction of tumor motion might be very useful and/or essential for especially free-breathing system during radiation delivery such as respiratory gating system and tumor tracking system. Neural network is powerful to express a time series with nonlinearity because its prediction algorithm is not governed by statistic formula but finds a rule of data expression. This study intended to assess applicability of neural network method to predict tumor motion in 4-dimensional radiotherapy. Scaled Conjugate Gradient algorithm was employed as a learning algorithm. Considering reparation data for 10 patients, prediction by the neural network algorithms was compared with the measurement by the real-time position management (RPM) system. The results showed that the neural network algorithm has the excellent accuracy of maximum absolute error smaller than 3 mm, except for the cases in which the maximum amplitude of respiration is over the range of respiration used in the learning process of neural network. It indicates the insufficient learning of the neural network for extrapolation. The problem could be solved by acquiring a full range of respiration before learning procedure. Further works are programmed to verify a feasibility of practical application for 4-dimensional treatment system, including prediction performance according to various system latency and irregular patterns of respiration.

  • PDF

Development of Video Image-Guided Setup (VIGS) System for Tomotherapy: Preliminary Study (단층치료용 비디오 영상기반 셋업 장치의 개발: 예비연구)

  • Kim, Jin Sung;Ju, Sang Gyu;Hong, Chae Seon;Jeong, Jaewon;Son, Kihong;Shin, Jung Suk;Shin, Eunheak;Ahn, Sung Hwan;Han, Youngyih;Choi, Doo Ho
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.85-91
    • /
    • 2013
  • At present, megavoltage computed tomography (MVCT) is the only method used to correct the position of tomotherapy patients. MVCT produces extra radiation, in addition to the radiation used for treatment, and repositioning also takes up much of the total treatment time. To address these issues, we suggest the use of a video image-guided setup (VIGS) system for correcting the position of tomotherapy patients. We developed an in-house program to correct the exact position of patients using two orthogonal images obtained from two video cameras installed at $90^{\circ}$ and fastened inside the tomotherapy gantry. The system is programmed to make automatic registration possible with the use of edge detection of the user-defined region of interest (ROI). A head-and-neck patient is then simulated using a humanoid phantom. After taking the computed tomography (CT) image, tomotherapy planning is performed. To mimic a clinical treatment course, we used an immobilization device to position the phantom on the tomotherapy couch and, using MVCT, corrected its position to match the one captured when the treatment was planned. Video images of the corrected position were used as reference images for the VIGS system. First, the position was repeatedly corrected 10 times using MVCT, and based on the saved reference video image, the patient position was then corrected 10 times using the VIGS method. Thereafter, the results of the two correction methods were compared. The results demonstrated that patient positioning using a video-imaging method ($41.7{\pm}11.2$ seconds) significantly reduces the overall time of the MVCT method ($420{\pm}6$ seconds) (p<0.05). However, there was no meaningful difference in accuracy between the two methods (x=0.11 mm, y=0.27 mm, z=0.58 mm, p>0.05). Because VIGS provides a more accurate result and reduces the required time, compared with the MVCT method, it is expected to manage the overall tomotherapy treatment process more efficiently.

Deduction and Verification of Optimal Factors for Stent Structure and Mechanical Reaction Using Finite Element Analysis (스텐트의 구조 및 기계적인 반응에 대한 최적인자 도출과 유한요소해석법을 통한 검증)

  • Jeon, Dong-Min;Jung, Won-Gyun;Kim, Han-Ki;Kim, Sang-Ho;Shin, Il-Gyun;Jang, Hong-Seok;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.201-208
    • /
    • 2010
  • Recently, along with technology development of endoscopic equipment, a stent has been developed for the convenience of operation, shortening of recovery times, and reduction of patient's pain. To this end, optimal factors are simulated for the stent structure and mechanical reaction and verified using finite element analysis. In order to compare to present commercialized product such as Zilver (Cook, Bloomington, Indiana, USA) and S.M.A.R.T (Cordis, Bridgewater Towsnhip, New Jersey, USA), mechanical impact factors were determined through Taguchi factor analysis, and flexibility and expandability of all the products including ours were tested using finite element analysis. Also, important factors were sought that fulfill the optimal condition using central composition method of response surface analysis, and optimal design were carried out based on the important factors. From the centra composition method of Response surface analysis, it is found that importat factors for flexibility is stent thickness (T) and unit area (W) and those for expandability is stent thickness (T). In results, important factors for optimum condition are 0.17 mm for stent thickness (T) and $0.09\;mm^2$ for unit area (W). Determined and verified by finite element analysis in out research institute, a stent was manufactured and tested with the results of better flexibility and expandability in optimal condition compared to other products. Recently, As Finite element analysis stent mechanical property assessment for research much proceed. But time and reduce expenses research rarely stent of optimum coditions. In this research, Important factor as mechanical impact factor stent Taguchi factor analysis arrangement to find flexibility with expansibility as Finite element analysis. Also, Using to Center composition method of Response surface method appropriate optimized condition searching for important factor, these considering had design optimized. Production stent time and reduce expenses was able to do the more coincide with optimum conditions. These kind of things as application plan industry of stent development period of time and reduce expenses etc. be of help to many economic development.

A research on Hyang-Yack-Ku-Keup-Bang(鄕藥救急方) (Restoration and Medico-Historic Investigation) (향약구급방(鄕藥救急方)에 대(對)한 고증(考證))

  • Sheen, Yeong-Il
    • Korean Journal of Oriental Medicine
    • /
    • v.2 no.1
    • /
    • pp.71-83
    • /
    • 1996
  • Hyang-Yack-Ku-Keup-Bang(鄕藥救急方) is our own, medical work written about the middle of the time of Korea Dynasty. I restored and researched this book because it needed to be illuminated about its medico-historic value and then I came to some conclusions as follows. 1. Hyang-Yack-Ku-Keup-Bang was published in Dae-jang-do-kam(大藏都監) of Kanghaw island(江華島) about the middle of Korea Dynasty. Choi Ja-ha(崔自河) republished it on original publication ground in Euiheung(義興) of Kyungsang-Province(慶尙道) in July, Taejong's(太宗) 17th year of Chosen Dynasty (A.D.1417) and this book was published again in Chungcheng Province(忠淸道) in Sejong's(世宗) 9th year(A.D.1427). The book published in Taejong's days was in the possession of books department of Kung-nae-cheng(宮內廳) in Japan and was the oldest medical book of existing ones. 2. Bang-Jung-Hyang-Yack-Mock-Cho-Bu(方中鄕藥目草部) of this book was originally intended to be adjusted in each division with the title of Bang-Jung-Hyang-Yack-Mock(方中鄕藥目). But Herb part(草部) only followed editing progress of Jeung-Lew-Bon-Cho(證類本草), the rest is not divided into each part and is together arranged at the below of Herb part with the title of Bang-Jung-Hyang-Yack-Mock-Cho-Bu. The Korean inscriptions on some drugstuffs in this book are different between Native Name(鄕名) of three volumes of provisions and general-spoken(俗云) of Bang-Jung-Hyang-Yack-Mock-Cho-Bu. In this, it is estimated that the publishing time and editor of tile volume of provisions and Bang-Jung-Hyang-Yack-Mock-Cho-Bu are different. I think Choi Ja-ha compiled this behind three volumes of provisions when he published. 3. This book picked some prescriptions which consisted of obtainable drugs with ease in Korea in the books of Chell-Keum-Yo-Bang(千金要方), Oi-Dae-Bi-Yo(外臺秘要), Tae-Peong-Sung-Hye-Bang(太平聖惠方), Ju-Hu-Bang(?後方), Kyung-Hum-Yang- Bang(經驗良方) Bo-Je-Bon-Sa-Bang(普濟本事方) Bi-Ye-Baik-Yo-Bang(備預百要方) and so on and got together our own prescriptions. On the whole Bi-Ye-Baik-Yo-Bang was a chief referrence book, On this, other books referred to and corrected. 4. In provisions quoted from Hyang-Yack-Jip-Sung-Bang(鄕藥集成方), there are seven provisions; leg-paralysis part, coughing part, headache part, obstetrics part, etc. don't show in this book. This is why Choi Ja-ha published only certain texts on Dae-jang-do-kam edition his own posession. So we can think the existing edition has a little misses compared with original edition. 5. This book recorded only names of drugstuffs in animal drug department like fowls, crab, goldbug, earthworm, etc. and didn't tell us ways of taking those. This is effect of Buddhist culture on medicine. This is efforts to practice 'Don't murder';one of Five Prohibition of Buddhism. 6. Beacause this book was published at the time, when our originative medicine would be set forth. This followed the Chinese ways in Theory, Treatment, Prescription and used 'Hyang Yack' in Medication out of theory of Korean medicine, which was a transitional form. So this is all important material which tell us aspects of development of 'Hyang Yack' the middle of Korea Dynasty.and this is also the beginning of originative, medical works like Dong-Eui-Bo-Kam(東醫寶鑑), Dong-Eui-Su-Bo-Won(東醫壽世保元). 7. There are few contents based on 'Byen-Jeung-Lon-Chi(辨證論治)'in this book. So we can see this book is not for doctors who study medical thoughts but for general public who suffer from diseases resulted from war. Because this book was written for a first-aid treatmeant, this is an index of medical service for the people those days. And this is also an useful datum for first-aid medicine or military medicine in these modern days. 8. Nowadays, parts of learned world of Korean medicine disregard essential theories and want to explain Korean medicine only by the theories or the methods of Western medicine. Moreover they don't adopt Chinese and Japanese theorys & thoughts about Oriental medicine in our own style and just view in there level. What was worse, there is a growing tendency for them to indulge in a trimming policy of scholarship and to take others' ideas. I think these trends to ignore our own medical thoughts involving growth of 'Hyang Yack' in the middle of Korea Dynasty, Dong-Eui-Bo-Kam and Dong-Eui-Su-Se-Bo-Won. So we, as researchers of Korean medicine, must get out of this tendency, and take over brilliant tradition and try to develop originative Korean medicine.

  • PDF

Characteristic Evaluation of Optically Stimulated Luminescent Dosimeter (OSLD) for Dosimetry (광유도발광선량계(Optically Stimulated Luminescent Dosimeter)의 선량 특성에 관한 고찰)

  • Kim, Jeong-Mi;Jeon, Su-Dong;Back, Geum-Mun;Jo, Young-Pil;Yun, Hwa-Ryong;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.123-129
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate dosimetric characteristics of Optically stimulated luminescent dosimeters (OSLD) for dosimetry Materials and Methods: InLight/OSL $NanoDot^{TM}$ dosimeters was used including $Inlight^{TM}MicroStar$ Reader, Solid Water Phantom, and Linear accelerator ($TRYLOGY^{(R)}$) OSLDs were placed at a Dmax in a solid water phantom and were irradiated with 100 cGy of 6 MV X-rays. Most irradiations were carried out using an SSD set up 100 cm, $10{\times}10\;cm^2$ field and 300 MU/min. The time dependence were measured at 10 minute intervals. The dose dependence were measured from 50 cGy to 600 cGy. The energy dependence was measured for nominal photon beam energies of 6, 15 MV and electron beam energies of 4-20 MeV. The dose rate dependence were also measured for dose rates of 100-1,000 MU/min. Finally, the PDD was measured by OSLDs and Ion-chamber. Results: The reproducibility of OSLD according to the Time flow was evaluated within ${\pm}2.5%$. The result of Linearity of OSLD, the dose was increased linearly up to about the 300 cGy and increased supralinearly above the 300 cGy. Energy and dose rate dependence of the response of OSL detectors were evaluated within ${\pm}2%$ and ${\pm}3%$. $PDD_{10}$ and PDD20 which were measured by OSLD was 66.7%, 38.4% and $PDD_{10}$ and $PDD_{20}$ which were measured by Ion-chamber was 66.6%, 38.3% Conclusion: As a result of analyzing characteration of OSLD, OSLD was evaluated within ${\pm}3%$ according to the change of the time, enregy and dose rate. The $PDD_{10}$ and $PDD_{20}$ are measured by OSLD and ion-chamber were evaluated within 0.3%. The OSL response is linear with a dose in the range 50~300 cGy. It was possible to repeat measurement many times and progress of the measurement of reading is easy. So the stability of the system and linear dose response relationship make it a good for dosimetry.

  • PDF

The Achievements and limitations of the U. S. Welfare Reform (미국 복지개혁의 성과와 한계)

  • Kim, Hwan-Joon
    • Korean Journal of Social Welfare
    • /
    • v.53
    • /
    • pp.129-153
    • /
    • 2003
  • This study examines the socio-economic impacts of recent welfare reform in the United States. Based on the neo-conservative critique to the traditional public assistance system for low-income families, the 1996 welfare reform has given greater emphases on reducing welfare dependency and increasing work effort and self-sufficiency among welfare recipients. In particular, the welfare reform legislation instituted 60-month lifetime limits on cash assistance, expanded mandatory work requirements, and placed financial penalties for noncompliance. With the well-timed economic boom in the second half of the 1990s, the welfare reform seems to achieve considerable progress; welfare caseload has declined sharply to reach less than 50% of its 1994 peak, single mothers' labor force participation has increased substantially, and child poverty has decreased. In spite of these good signals, the welfare reform also has several potential problems. Many welfare leavers participate in the labor market, but not all (or most) of them. The economic well being of working welfare leavers did not increased significantly, because earnings increase was canceled out by parallel decrease in welfare benefits. Furthermore, most of working welfare leavers are employed in jobs with poor employment stability and low wages, making them highly vulnerable to frequent layoff, long-time joblessness, persistent poverty, and welfare recidivism. Another serious problem of the welfare reform is that a substantial number of welfare recipients are faced with extreme difficulties in finding jobs, because they have severe barriers to employment. The new welfare system with 5-year time limit can severely threaten the livelihoods of these people. The welfare reform presupposes that welfare recipients can achieve self-reliance by increasing their labor market activities. However, empirical evidences suggest that many people are unable to respond to the new, work-oriented welfare strategy. It may be a very difficult task to achieve both objectives of the welfare reform((1) providing adequate income security for low-income families and (2) promoting self-sufficiency) at the same time, because sometimes they are conflicting each other. With this in mind, a possible solution can be to distinguish welfare recipients into "(Very)-Hard-to-Employ" group and "(Relatively)-Ready-to-Work" group, based on elaborate examinations of a wide range of personal conditions. For the former group, the primary objective of welfare policies should be the first one(providing income security). For the "Ready-to-Work" group, follow-up services to promote job retention and advancement, as well as skill-training and job-search services, are very important. The U. S. experiences of the welfare reform provide some useful implications for newly developing Korean public assistance policies for the able-bodied low-income population.

  • PDF

The Development of Education Model for CA-RP(Cognitive Apprenticeship-Based Research Paper) to Improve the Research Capabilities for Majors Students of Radiological Technology (방사선 전공학생의 연구역량 증진을 위한 인지적 도제기반 논문작성 교육 모형 개발)

  • Park, Hoon-Hee;Chung, Hyun-Suk;Lee, Yun-Hee;Kim, Hyun-Soo;Kang, Byung-Sam;Son, Jin-Hyun;Min, Jung-Hwan;Lyu, Kwang-Yeul
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.99-110
    • /
    • 2013
  • In the medical field, the necessity of education growth for the professional Radiation Technologists has been emphasized to become experts on radiation and the radiation field is important of the society. Also, in hospitals and companies, important on thesis is getting higher in order to active and cope with rapidly changing internal and external environment and a more in-depth expert training, the necessity of new teaching and learning model that can cope with changes in a more proactive has become. Thesis writing classes brought limits to the in-depth learning as to start a semester and rely on only specific programs besides, inevitable on passive participation. In addition, it does not have a variety opportunity to present, an actual opportunity that can be written and discussed does not provide much caused by instructor-led classes. As well as, it has had a direct impact on the quality of the thesis, furthermore, having the opportunity to participate in various conferences showed the limitations. In order to solve these problems, in this study, writing thesis has organized training operations as a consistent gradual deepening of learning, at the same time, the operational idea was proposed based on the connectivity integrated operating and effective training program & instructional tool for improving the ability to perform the written actual thesis. The development of teaching and learning model consisted of 4 system modeling, scaffolding, articulation, exploration. Depending on the nature of the course, consisting team following the personal interest and the topic allow for connection subject, based on this, promote research capacity through a step-by-step evaluation and feedback and, fundamentally strengthen problem-solving skills through the journal studies, help not only solving the real-time problem by taking wiki-space but also efficient use of time, increase the quality of the thesis by activating cooperation through mentoring, as a result, it was to promote a positive partnership with the academic. Support system in three stages planning subject, progress & writing, writing thesis & presentation and based on cognitive apprenticeship. The ongoing Coaching and Reflection of professor and expert was applied in order to maintain these activities smoothly. The results of this study will introduce actively, voluntarily and substantially join to learners, by doing so, culture the enhancement of creativity, originality and the ability to co-work and by enhance the expertise of based-knowledge, it is considered to be help to improve the comprehensive ability.

Change of Fragrant Components by Flowering Stages in Lilium Oriental Hybrid 'Casa Blanca' (오리엔탈 나리 '카사블랑카'의 개화단계별 향기성분 변화)

  • Rho, A Ran;Pak, Chun Ho
    • Horticultural Science & Technology
    • /
    • v.19 no.2
    • /
    • pp.163-169
    • /
    • 2001
  • This experiment was conducted to find out suitable extraction time of available fragrant component in Lilium Oriental Hybrida 'Casa Blanca' based on qualitative and quantitative variation of its fragrant component in its flowering stages. The content of essential oil in its flowering stages increased with the progress of flowering stages except flower bud stage and it had the most oil content in its stage after full bloom. The analysis of the essential oil in Lilium Oriental Hybrida 'Casa Blanca' in its flowering stages shows that its main constituents were farnesol (18.96%), benzyl salicylate (13.81%), butyl-hydroxy toluene (12.87%), geranyl linalool isomer (7.46%), isoeugenol (7.17%) in its each stage. Benzenoids had much content at half bloom stage and full bloom stage while fatty acid derivatives had much content at initial flowering stage and after flowering stage. Most benzenoids such as butyl-hydroxy toluene and isoeugenol, which are some of main constituents of Lilium Oriental Hybrida 'Casa Blanca' had strong antioxidant effect. So they were expected to be used as antioxidant agents for food, feed, vegetable oil. The content of monoterpene compounds like geranyl linalool isomer increased at its later stage. Sesquiterpene such as farnesol, which is main component of lily existed only at full bloom stage. Therefore farnesol and geranyl linalool isomer of Lilium Oriental Hybrida 'Casa Blanca' are expected to be used for important spices with good fragrance. The suitable extraction time for the usable main constituents of Lilium Oriental Hybrida 'Casa Blanca' is as follows; farnesol and benzyl salicylate: at full bloom stage, butyl-hydroxy toluene: at half bloom stage, geranyl linalool isomer and isoeugenol: at stage after full bloom. Finally there was variation in essential oil components and contents of Lilium Oriental Hybrida 'Casa Blanca' in its flowering stages and they are expected to be used usefully for flavor industry, food industry, aromatherapy, when they are extracted at their suitable extraction time.

  • PDF

Optimization of β-Glucan Extraction Process from Rice Bran and Rice Germ Using Response Surface Methodology (미강과 배아로부터 β-glucan의 추출조건 최적화 및 기능성 생리활성)

  • Jeon, Ju-Yeong;Park, Ji-Hae;Kim, Se-Hwan;Choi, Yong-Hee
    • Food Engineering Progress
    • /
    • v.13 no.1
    • /
    • pp.8-15
    • /
    • 2009
  • This study was investigated on optimal conditions of the functional activities of ${\beta}$-glucan which was extracted from rice bran (RB) and rice germ (RG) using response surface methodology. The extraction temperature was varied in the $80-100^{\circ}C$, the extraction time between 2-10 min, and the ethanol concentration was in the interval of 30-70%. A central composite design was applied to investigate the effects of independent variables of extraction temperature ($X_1$), extraction time ($X_2$) and ethanol concentration ($X_3$) on dependent variables such as electron donating ability of RB ($Y_1$), electron donating ability of RG ($Y_2$), total phenolics of RB ($Y_3$), total phenolics of RG ($Y_4$), ${\beta}$-glucan contents of RB ($Y_5$) and ${\beta}$-glucan contents of RG ($Y_6$). As a result, the highest $Y_1$ level was 84.02% at $92.60^{\circ}C$, 2.75 min and 60.41% in saddle point. This value was affected by extraction temperature (P<0.05). The value of $Y_2$ was found to be the highest at $87.52^{\circ}C$, 2.23 min and 54.40% in saddle point. The highest $Y_3$ level was $98.56^{\circ}C$, 6.69 min and 40.26% in saddle point, and this extraction was greatly influenced by extraction temperature (P<0.01) and ethanol concentration (P<0.05). The value of $Y_4$ was found to be highest at $95.73^{\circ}C$, 9.19 min and 53.67% in minimum point. The value of $Y_5$ was found to be the highest at $96.23^{\circ}C$, 7.70 min and 63.69% in saddle point. The value of $Y_6$ was found to be highest at $87.82^{\circ}C$, 2.10 min and 50.03% in minimum point, and this extraction was greatly influenced by extraction time (P<0.01).