• 제목/요약/키워드: Time of flight measurements

검색결과 53건 처리시간 0.026초

$SF_{6+}Ar$혼합기체의 전자수송특성 개선에 관한 연구 (A Study on the Improvement of the Electron Transport Properties in $SF_{6+}Ar$ Mixtures Gas)

  • 하성철;김상남;유회영;서상현;임상원;전병훈
    • 한국전기전자재료학회논문지
    • /
    • 제11권1호
    • /
    • pp.67-73
    • /
    • 1998
  • In this paper, the electron swarm parameters in the 0.5% and 0.2% SF\ulcorner+Ar mixtures are measured by time of flight method over the E/N(Td) range from 30 to 300(Td). The measurements have been carried out by the double shutter drift tube with variable drift distance from the cathod. A two-term approximation of the boltzmann equation analysis and Monte Carlo simulation have been also used to study electron transport coefficients. We have calculated W, $ND_L,\;ND_T,\;\alpha,\;\eta,\;\alpha-\eta$, and the limiting breakdown electric field to gas mixtures ratio in pure $SF_6$+Ar mixtures. The electron energy distribution function has been analysed in $SF_6$+Ar mixtures at E/N : 200(Td) for a case of the equilibrium region in the mean electron energy. The measured results and the calculated results have been compared each other.

  • PDF

Precision Assessment of Near Real Time Precise Orbit Determination for Low Earth Orbiter

  • Choi, Jong-Yeoun;Lee, Sang-Jeong
    • Journal of Astronomy and Space Sciences
    • /
    • 제28권1호
    • /
    • pp.55-62
    • /
    • 2011
  • The precise orbit determination (POD) of low earth orbiter (LEO) has complied with its required positioning accuracy by the double-differencing of observations between International GNSS Service (IGS) and LEO to eliminate the common clock error of the global positioning system (GPS) satellites and receiver. Using this method, we also have achieved the 1 m positioning accuracy of Korea Multi-Purpose Satellite (KOMPSAT)-2. However double-differencing POD has huge load of processing the global network of lots of ground stations because LEO turns around the Earth with rapid velocity. And both the centimeter accuracy and the near real time (NRT) processing have been needed in the LEO POD applications--atmospheric sounding or urgent image processing--as well as the surveying. An alternative to differential GPS for high accuracy NRT POD is precise point positioning (PPP) to use measurements from one satellite receiver only, to replace the broadcast navigation message with precise post processed values from IGS, and to have phase measurements of dual frequency GPS receiver. PPP can obtain positioning accuracy comparable to that of differential positioning. KOMPSAT-5 has a precise dual frequency GPS flight receiver (integrated GPS and occultation receiver, IGOR) to satisfy the accuracy requirements of 20 cm positioning accuracy for highly precise synthetic aperture radar image processing and to collect GPS radio occultation measurements for atmospheric sounding. In this paper we obtained about 3-5 cm positioning accuracies using the real GPS data of the Gravity Recover and Climate Experiment (GRACE) satellites loaded the Blackjack receiver, a predecessor of IGOR. And it is important to reduce the latency of orbit determination processing in the NRT POD. This latency is determined as the volume of GPS measurements. Thus changing the sampling intervals, we show their latency to able to reduce without the precision degradation as the assessment of their precision.

VERTICAL OZONE DENSITY PROFILING BY UV RADIOMETER ONBOARD KSR-III

  • Hwang Seung-Hyun;Kim Jhoon;Lee Soo-Jin;Kim Kwang-Soo;Ji Ki-Man;Shin Myung-Ho;Chung Eui-Seung
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2004년도 한국우주과학회보 제13권2호
    • /
    • pp.372-375
    • /
    • 2004
  • The UV radiometer payload was launched successfully from the west coastal area of Korea Peninsula aboard KSR-III on 28, Nov 2002. KSR-III was the Korean third generation sounding rocket and was developed as intermediate step to larger space launch vehicle with liquid propulsion engine system. UV radiometer onboard KSR-III consists of UV and visible band optical phototubes to measure the direct solar attenuation during rocket ascending phase. For UV detection, 4 channel of sensors were installed in electronics payload section and each channel has 255, 290, 310nm center wavelengths, respectively. 450nm channel was used as reference for correction of the rocket attitude during the flight. Transmission characteristics of all channels were calibrated precisely prior to the flight test at the Optical Lab. in KARI (Korea Aerospace Research Institute). During a total of 231s flight time, the onboard data telemetered to the ground station in real time. The ozone column density was calculated by this telemetry raw data. From the calculated column density, the vertical ozone profile over Korea Peninsula was obtained with sensor calibration data. Our results had reasonable agreements compared with various observations such as ground Umkhr measurement at Yonsei site, ozonesonde at Pohang site, and satellite measurements of HALOE and POAM. The sensitivity analysis of retrieval algorithm for parameters was performed and it was provided that significant error sources of the retrieval algorithm.

  • PDF

로켓 모션테이블 실시간 모의시험

  • 선병찬;박용규;최형돈;조광래
    • 항공우주기술
    • /
    • 제3권1호
    • /
    • pp.170-178
    • /
    • 2004
  • 본 논문은 KSR-III 개발경험을 토대로 모션테이블을 이용한 로켓 6자유도 실시간모의시험(HILS) 방안에 대해 다루고 있다. 모션테이블 HILS 시험을 통해, 3축 모션테이블의 동특성 지연에 따른 제어루프의 안정성을 판단하고 종합 HILS 시험을 위한 기초 자료를 제공하게 된다. 모션테이블 HILS 초기화 시험을 통해, 관성항법장치 초기정렬을 위한 초기자세 각 유지 알고리듬 시험, 발사시작 신호 모사를 통한 시각동기화 시험, 외부기록계를 이용한 실시간 조정시험 등을 수행하게 되고, 개루프 HILS 시험을 통해 정상 상태 비행 상황 및 슬로싱, 벤딩, TWD, 바람, 추력비정렬오차 등의 영향이 존재하는 비행 상황에 대한 모션테이블 운용 시험을 수행하게 되며, 최종적으로 모션테이블 자세각을 궤환루프의 입력으로 궤환시킨 폐루프 HILS를 통해 제어루프의 안정성 시험을 완료하게 된다.

  • PDF

Measurement of TOF of fast neutrons with 238U target

  • Li, Meng;Guan, Yuanfan;Lu, Chengui;Zhang, Junwei;Yuan, Xiaohua;Duan, Limin;Yang, Herun;Hu, Rongjiang;He, Zhiyong;Wei, Xianglun;Ma, Peng;Gan, Zaiguo;Yang, Chunli;Zhang, Hongbin;Chen, Liang;Qiu, Tianli;Hou, Yikai
    • Nuclear Engineering and Technology
    • /
    • 제53권6호
    • /
    • pp.1964-1969
    • /
    • 2021
  • We developed a Dual-PPACs detector for fast neutron measurements that consists of two sets of PPAC: conventional PPAC and fission PPAC. A238U(U3O8) coating is placed in the fission PPAC's anode, which is used as the neutrons conversion layer. An experiment was performed to measure neutron time-of-flight (TOF) in which 252Cf spontaneous fission source was used. An excellent time resolution of 164ps has been observed at 6 mbar in isobutene gas. With the excellent time resolution of Dual-PPACs detector, exact neutron energy can be extracted from the timing measurement. The experimental detection efficiency was 1.9 × 10-7, consistent with the efficiency of 2.5 × 10-7 given by a Geant4 simulation. Ultimately, the results show that the Dual-PPACs detector is a suitable candidate for measuring fast neutrons in the future CiADS system.

Measurement of Drifting Mobility and Transit Time of Holes and Electrons in Stabilized a-Se Film

  • Kim, Jae-Hyung;Park, Chang-Hee;Nam, Sang-Hee
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.362-363
    • /
    • 2007
  • The transport property of stabilized amorphous selenium typical of the material used in direct conversion x-ray imaging devices was studied using the moving photo-carrier grating (MPG) technique and time-of-flight (TOF) measurements. For MPG measurement, the electron and hole mobility, and recombination lifetime of a-Se films with arsenic (As) additions have been obtained. For TOF measurement, a laser beam with pulse duration of 5ns and wavelength of 350 nm was illuminated on the surface of a-Se with thickness of $400{\mu}m$.

  • PDF

Pressure-volume-temperature gauging method experiment using liquid nitrogen under microgravity condition of parabolic flight

  • Seo, Mansu;Park, Hana;Yoo, DonGyu;Jung, Youngsuk;Jeong, Sangkwon
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제16권2호
    • /
    • pp.64-69
    • /
    • 2014
  • Measuring an exact amount of remaining cryogenic liquid propellant under microgravity condition is one of the important issues of rocket vehicle. A Pressure-Volume-Temperature (PVT) gauging method is attractive due to its minimal additional hardware and simple gauging process. In this paper, PVT gauging method using liquid nitrogen is investigated under microgravity condition with parabolic flight. A 9.2 litre metal cryogenic liquid storage tank containing approximately 30% of liquid nitrogen is pressurized by ambient temperature helium gas. During microgravity condition, the inside of the liquid tank becomes near-isothermal condition within 1 K difference indicated by 6 silicon diode sensors vertically distributed in the middle of the liquid tank. Helium injection with higher mass flow rate after 10 seconds of the waiting time results in successful measurements of helium partial pressure in the tank. Average liquid volume measurement error is within 11% of the whole liquid tank volume and standard deviation of errors is 11.9. As a result, the applicability of PVT gauging method to liquid propellant stored in space is proven with good measurement accuracy.

Experiment of Drifting Mobilities of Holes and Electrons in Stabilized a-Se Film

  • Kang, Sang-Sik;Park, Ji-Koon;Park, Jang-Yong;Kim, Jae-Hyung;Nam, Sang-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • 제4권6호
    • /
    • pp.9-12
    • /
    • 2003
  • The electrical properties of stabilized amorphous selenium typical of the material used in direct conversion x-ray imaging devices are reported. Carrier mobility was measured using time-of-flight (TOF) measurements to investigate the transport properties of holes and electrons in stabilized a-Se film. A laser beam with pulse duration of 5 ns and wavelength of 350nm was illuminated on the surface of a-Se with thickness of 400 $\mu\textrm{m}$. The photo induced signals of a-Se film as a function of time were measured. The measured transit times of hole and electron were about 8.73${\mu}\textrm{s}$ and 229.17${\mu}\textrm{s}$, respectively. The hole and electron drift mobilities decreases with increase of electric field up to 4V/$\mu\textrm{m}$. Above 4V/$\mu\textrm{m}$, the measured drift mobilities exhibited no observable dependence with respect to electric field. The experimental results showed that the hole and electron drifting mobility were 0.04584 $\textrm{cm}^2$ V$\^$-1/s$\^$-1/ sand 0.00174 $\textrm{cm}^2$V$\^$-1/s$\^$-1/ at 10 V/$\mu\textrm{m}$.

3D Head Modeling using Depth Sensor

  • Song, Eungyeol;Choi, Jaesung;Jeon, Taejae;Lee, Sangyoun
    • Journal of International Society for Simulation Surgery
    • /
    • 제2권1호
    • /
    • pp.13-16
    • /
    • 2015
  • Purpose We conducted a study on the reconstruction of the head's shape in 3D using the ToF depth sensor. A time-of-flight camera (ToF camera) is a range imaging camera system that resolves distance based on the known speed of light, measuring the time-of-flight of a light signal between the camera and the subject for each point of the image. The above method is the safest way of measuring the head shape of plagiocephaly patients in 3D. The texture, appearance and size of the head were reconstructed from the measured data and we used the SDF method for a precise reconstruction. Materials and Methods To generate a precise model, mesh was generated by using Marching cube and SDF. Results The ground truth was determined by measuring 10 people of experiment participants for 3 times repetitively and the created 3D model of the same part from this experiment was measured as well. Measurement of actual head circumference and the reconstructed model were made according to the layer 3 standard and measurement errors were also calculated. As a result, we were able to gain exact results with an average error of 0.9 cm, standard deviation of 0.9, min: 0.2 and max: 1.4. Conclusion The suggested method was able to complete the 3D model by minimizing errors. This model is very effective in terms of quantitative and objective evaluation. However, measurement range somewhat lacks 3D information for the manufacture of protective helmets, as measurements were made according to the layer 3 standard. As a result, measurement range will need to be widened to facilitate production of more precise and perfectively protective helmets by conducting scans on all head circumferences in the future.

칼새 날개의 비틀림 각에 대한 공력측정 및 PIV 연구 (Aerodynamic Force Measurements and PIV Study for the Twisting Angle of a Swift Wing Model)

  • 복정진;장조원
    • 한국항공우주학회지
    • /
    • 제43권9호
    • /
    • pp.765-772
    • /
    • 2015
  • 칼새 비행의 생체모방 초소형 비행체 적용 가능성을 확인하기 위한 공력측정과 위상동기 PIV 연구가 수행되었다. 2축 회전자유도의 로봇 날개 모델과 불어내기식 풍동을 사용하였다. 비틀림 각은 ${\pm}0$, ${\pm}5$, ${\pm}10$, ${\pm}20$도의 진폭을 갖고, 스트로크각은 90도의 위상차를 갖는 단순조화함수로 변화시켰다. 비틀림 각에 따른 시간에 대한 양력계수 변화는 작은 공력감소와 지연만을 나타내며 주목할 만한 차이를 보이지 않았다. 그러나 항력은 작은 비틀림 각 변화가 큰추력을 생성할 수 있음을 보여주었다. 이러한 것들은 칼새가 비행 중에 작은 비틀림 각을 사용하는 이유를 간접적으로 설명해 준다. PIV연구 결과는 공력지연이 날개주위의 와류구조와 밀접한 관계있다는 것을 보여준다. 이러한 결과는 칼새 모방형 초소형비행체 설계에 있어 비틀림 각은 필수적인 파라미터로서 반드시 고려되어야 함을 의미한다.