• Title/Summary/Keyword: Time Spacing

Search Result 448, Processing Time 0.021 seconds

Study of the Characteristics and Crystal Growth of a shorted Wire by Overcurrent (과전류에 의해 단락된 전선의 결정성장 특성에 관한 연구)

  • Park, Jin-Young;Bang, Sun-Bae;Ko, Young-Ho
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.83-90
    • /
    • 2017
  • If an overcurrent exceeding the rated value is applied to an electric wire, the temperature of the electric wire increases, and the electric wire covering deteriorates to cause a short circuit. The upper limit temperature of the wire varies according to the magnitude of the overcurrent. When a short circuit occurs at each upper temperature limit, a cooling speed difference occurs during the solidification process due to the temperature difference between the short circuit temperature and the wire surface temperature. At this time, the pattern characteristics of the dendritic structure formed on the molten cross section are different. In this study, the upper temperature limit, which varied according to the overcurrent magnitude, was measured. At the time a short circuit occurred, the second branch spacing (dendrite Arm Spacing : DAS) of the dendrite was analyzed and the numerical value was quantified. The experimental results showed that the upper temperature limit increases with the magnitude of the overcurrent, and that the second branch spacing increases with increasing wire temperature.

Active tuned tandem mass dampers for seismic structures

  • Li, Chunxiang;Cao, Liyuan
    • Earthquakes and Structures
    • /
    • v.17 no.2
    • /
    • pp.143-162
    • /
    • 2019
  • Motivated by a simpler and more compact hybrid active tuned mass damper (ATMD) system with wide frequency spacing (i.e., high robustness) but not reducing the effectiveness using the least number of ATMD units, the active tuned tandem mass dampers (ATTMD) have been proposed to attenuate undesirable oscillations of structures under the ground acceleration. Likewise, it is expected that the frequency spacing of the ATTMD is comparable to that of the active multiple tuned mass dampers (AMTMD) or the multiple tuned mass dampers (MTMD). In accordance with the mode generalised system in the specific vibration mode being controlled (simply referred herein to as the structure), the closed-form expression of the dimensionless displacement variances has been derived for the structure with the attached ATTMD. The criterion for the optimum searching may then be determined as minimization of the dimensionless displacement variances. Employing the gradient-based optimization technique, the effects of varying key parameters on the performance of the ATTMD have been scrutinized in order to probe into its superiority. Meanwhile, for the purpose of a systematic comparison, the optimum results of two active tuned mass dampers (two ATMDs), two tuned mass dampers (two TMDs) without the linking damper, and the TTMD are included into consideration. Subsequent to work in the frequency domain, a real-time Simulink implementation of dynamic analysis of the structure with the ATTMD under earthquakes is carried out to verify the findings of effectiveness and stroke in the frequency domain. Results clearly show that the findings in the time domain support the ones in the frequency domain. The whole work demonstrates that ATTMD outperforms two ATMDs, two TMDs, and TTMD. Thereinto, a wide frequency spacing feature of the ATTMD is its highlight, thus deeming it a high robustness control device. Furthermore, the ATTMD system only needs the linking dashpot, thus embodying its simplicity.

Performance-Based Evaluation on Evacuation Safety of Road Tunnels Considering Fire Size and Evacuation Exit (화재 크기와 피난연결통로를 고려한 도로터널의 성능기반 피난안전성 평가)

  • Si-Hyun Oh;In-Wook Heo;Sang-Ki Lee;Seung-Ho Choi;Sunnie Haam
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.4
    • /
    • pp.28-36
    • /
    • 2024
  • In this study, an analytical evaluation of evacuation safety in typical road tunnels was conducted. The Fire Dynamics Simulator (FDS) was employed to perform fire simulations with varying fire sizes to determine the allowable evacuation time in road tunnels. Additionally, evacuation simulations were performed using Pathfinder, considering the width of barrier doors and the spacing of evacuation passageways, to calculate the required evacuation time. A comparison between the allowable and required evacuation times was conducted to assess the impact of fire size, passageway spacing, and barrier door width on tunnel evacuation safety. The results from the fire and evacuation simulations indicated that an increase in fire size and passageway spacing, along with a decrease in door width, resulted in an increase in the number of casualties. Conversely, increasing the barrier door width to more than 1.2meters led to a reduction in casualties as passageway spacing increased.

Identification of moving train loads on railway bridge based on strain monitoring

  • Wang, Hao;Zhu, Qingxin;Li, Jian;Mao, Jianxiao;Hu, Suoting;Zhao, Xinxin
    • Smart Structures and Systems
    • /
    • v.23 no.3
    • /
    • pp.263-278
    • /
    • 2019
  • Moving train load parameters, including train speed, axle spacing, gross train weight and axle weights, are identified based on strain-monitoring data. In this paper, according to influence line theory, the classic moving force identification method is enhanced to handle time-varying velocity of the train. First, the moments that the axles move through a set of fixed points are identified from a series of pulses extracted from the second derivative of the structural strain response. Subsequently, the train speed and axle spacing are identified. In addition, based on the fact that the integral area of the structural strain response is a constant under a unit force at a unit speed, the gross train weight can be obtained from the integral area of the measured strain response. Meanwhile, the corrected second derivative peak values, in which the effect of time-varying velocity is eliminated, are selected to distribute the gross train weight. Hence the axle weights could be identified. Afterwards, numerical simulations are employed to verify the proposed method and investigate the effect of the sampling frequency on the identification accuracy. Eventually, the method is verified using the real-time strain data of a continuous steel truss railway bridge. Results show that train speed, axle spacing and gross train weight can be accurately identified in the time domain. However, only the approximate values of the axle weights could be obtained with the updated method. The identified results can provide reliable reference for determining fatigue deterioration and predicting the remaining service life of railway bridges.

A numerical study on the optimum spacing of disc cutters considering rock strength and penetration depth using discrete element method (암반강도 및 압입깊이에 따른 디스크커터의 최적간격 산정을 위한 개별요소법 기반 수치해석 연구)

  • Lee, Sang Yun;Song, Ki-il;Jung, Ju Hwan
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.4
    • /
    • pp.383-399
    • /
    • 2020
  • Optimizing the spacing of the disc cutter is a key element in the design of the TBM cutter head, which determines the drilling performance of the TBM. The full-scale linear cutting test is known as the most reliable and accurate test for calculating the spacing of the disc cutter, but it has the disadvantage of costly and time-consuming for the full-scale experiment. In this study, through the numerical analysis study based on the discrete element method, the tendency between Specific Energy-S/P ratio according to uniaxial compression strength and penetration depth of rock was analyzed, and the optimum spacing of 17-inch disc cutter was derived. To examine the appropriateness of the numerical analysis model, the rolling force acting on the disc cutter was compared and reviewed with the CSM model. As a result of numerical analysis for the linear cutting test, the rolling force acting on the disc cutter was analyzed to be similar to the rolling force derived from the theoretical formula of the CSM model. From the numerical analysis on 5 UCS cases (50 MPa, 70 MPa, 100 MPa, 150 MPa, 200 MPa), it is found that the range of the optimum spacing of the disc cutter decreases as the rock strength increases. And it can be concluded that 80~100 mm of disc cutter spacing is the optimum range having minimum specific energy regardless of rock strength. This tends to coincide with the optimal spacing of previously reported disk cutters, which underpins the disk cutter spacing calculated through this study.

Performance Analysis of Space-Time Codes in Realistic Propagation Environments: A Moment Generating Function-Based Approach

  • Lamahewa Tharaka A.;Simon Marvin K.;Kennedy Rodney A.;Abhayapala Thushara D.
    • Journal of Communications and Networks
    • /
    • v.7 no.4
    • /
    • pp.450-461
    • /
    • 2005
  • In this paper, we derive analytical expressions for the exact pairwise error probability (PEP) of a space-time coded system operating over spatially correlated fast (constant over the duration of a symbol) and slow (constant over the length of a code word) fad­ing channels using a moment-generating function-based approach. We discuss two analytical techniques that can be used to evaluate the exact-PEPs (and therefore, approximate the average bit error probability (BEP)) in closed form. These analytical expressions are more realistic than previously published PEP expressions as they fully account for antenna spacing, antenna geometries (uniform linear array, uniform grid array, uniform circular array, etc.) and scattering models (uniform, Gaussian, Laplacian, Von-mises, etc.). Inclusion of spatial information in these expressions provides valuable insights into the physical factors determining the performance of a space-time code. Using these new PEP expressions, we investigate the effect of antenna spacing, antenna geometries and azimuth power distribution parameters (angle of arrival/departure and angular spread) on the performance of a four-state QPSK space-time trellis code proposed by Tarokh et al. for two transmit antennas.

Computation of Thermal Flow for Automotive Lamp by Using Geometric Octree Method (기하학적 Octree 격자생성법을 이용한 자동차 헤드램프 내부의 열유동 계산)

  • Sah Jong-Youb;Park Jong-Ryul;Kang Dong-Min
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.152-156
    • /
    • 2001
  • Three dimensional orthogonal grid generation is able to control effectively the grid spacing near the boundaries, but there are some difficulty to meshing complex geometry. The mesh complex geometry by orthogonal grid generation method must divide block of geometry It is required a careful skill, and long time. Its also difficulty to make unstructured mesh on complex geometry. Particularly, three dimensional geometry must have more time and effort. Recently, there have been growing interests in mesh generation of complex grometry, aslike an automobile headlamp, the heart. The method of easily meshing complex geometry is resarched to solve them. We suggest octree grid into one among these methods. As octrce grid is automaticaly adapted at the boundaries by determine the level operations to control the grid spacing near the boundaries are unnecessary. In this paper we showed throe dimensional mesh generation, and heat-flow analysis on the octree mesh.

  • PDF

The Effects of Blouse Types on Ventilation Clothing Microclimate (블라우스내에 형성되는공기층이 의복내환기에 미치는 영향 연구)

  • Park Woo Mee;Choi Chul Ho
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.16 no.2
    • /
    • pp.169-180
    • /
    • 1992
  • The purpose of this study is to investigate the effects of type of clothing microclimate and exercise condition on ventilation. The experimental system employed a trace gas technique of the previous research. Clothing microclimate volume measurement was based on the substitution water technique for inter-clothing air volume. The experimental variables were tested at four levels of clothing microclimate spacing, microclimate shape of the previous research and two levels of exercise conditions. 2, 4, 6 cm ease were added to B/2+4 of basic blouse pattern for the microclimate spacing variable. Each combination of three variables were tested in triplicate. Analysis of variance of experimental variables on vetilation, such as oxygen exchange rate, half time of first order model was conducted. Oxygen exchange rate and half time of first order model are affected by the shape of microclimate air and exercise condition.

  • PDF

A Stop-and-Go Cruise Control Strategy with Guaranteed String Stability (String Stability를 보장하는 정지/서행 순항제어 시스템)

  • 박요한;이경수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.6
    • /
    • pp.227-233
    • /
    • 2002
  • A vehicle longitudinal control strategy with guaranteed string stability for vehicle stop-and-go(SG) cruise control is presented in this paper. The SG cruise control systems should be designed such that string stability can be guaranteed in addition to that every vehicle in a string of SG cruise control vehicles must track any bounded acceleration and velocity profile of its preceding vehicle with a bounded spacing and velocity error. An optimal vehicle following control law based on the information of the 1311owing distance (clearance) and its velocity relative to the vehicle ahead (relative velocity) has been used and string stability analysis has been done based on the control law and constant time gap spacing policy, A validated multi-vehicle simulation package has been shown that the string stability analysis using the approximate model of the vehicle servo-loop which includes vehicle powertrain and brake control system dynamics is valid in the design of the SG cruise control law with guaranteed string stability.

Analysis and Preventive Countermeasures of Power Line Twisting for 4-conductor bundle Transmission Line (4도체 송전선로의 전력선 염회 분석 및 방지 방안)

  • Min, B.W.;An, J.S.;NamKung, D.;Park, J.W.;Kim, Y.D.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.406-410
    • /
    • 2001
  • For 4-conductor bundle transmission line spacer damper are equipped so as to keep the spacing between sub conductors. For 4-conductor bundle the subspan spacing of a spacer damper is determined and applied in order that the bundle may get restored to a normal state when 4-conductor bundle is rolled by rigid body vibration due to wind. But 4 conductors of 345kV 4-conductor bundle transmission line were twisted by the angle of $315^{\circ}$ for the first time korea. In this paper, we will analyze the reason of the power line twisting of 4-conductor bundle which occurred for the first time in korea and offer the preventive countermeasures for this

  • PDF