• Title/Summary/Keyword: Time Domain Response

Search Result 822, Processing Time 0.028 seconds

Evaluation of energy response of space steel frames subjected to seismic loads

  • Ozakgul, Kadir
    • Structural Engineering and Mechanics
    • /
    • v.54 no.4
    • /
    • pp.809-827
    • /
    • 2015
  • In this paper, seismic energy response of inelastic steel structures under earthquake excitations is investigated. For this purpose, a numerical procedure based on nonlinear dynamic analysis is developed by considering material, geometric and connection nonlinearities. Material nonlinearity is modeled by the inversion of Ramberg-Osgood equation. Nonlinearity caused by the interaction between the axial force and bending moment is also defined considering stability functions, while the geometric nonlinearity caused by axial forces is described using geometric stiffness matrix. Cyclic behaviour of steel connections is taken into account by employing independent hardening model. Dynamic equation of motion is solved by Newmark's constant acceleration method in the time history domain. Energy response analysis of space frames is performed by using this proposed numerical method. Finally, for the first time, the distribution of the different energy types versus time at the duration of the earthquake ground motion is obtained where in addition error analysis for the numerical solutions is carried out and plotted depending on the relative error calculated as a function of energy balance versus time.

Transient Response of a Permeable Crack Normal to a Piezoelectric-elastic Interface: Anti-plane Problem

  • Kwon, Soon-Man;Lee, Kang-Yong
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.9
    • /
    • pp.1500-1511
    • /
    • 2004
  • In this paper, the anti-plane transient response of a central crack normal to the interface between a piezoelectric ceramics and two same elastic materials is considered. The assumed crack surfaces are permeable. By virtue of integral transform methods, the electro elastic mixed boundary problems are formulated as two set of dual integral equations, which, in turn, are reduced to a Fredholm integral equation of the second kind in the Laplace transform domain. Time domain solutions are obtained by inverting Laplace domain solutions using a numerical scheme. Numerical values on the quasi-static stress intensity factor and the dynamic energy release rate are presented to show the dependences upon the geometry, material combination, electromechanical coupling coefficient and electric field.

Time-Domain Electric Field Integral Equation Solving for a Stable Solution of Electromagnetic Transient Scattering (안정된 전자파 과도 산란해를 얻기 위한 시간영역 전장 적분방정식 해석)

  • Jeong, Baek-Ho;Kim, Chae-Yeong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.39 no.4
    • /
    • pp.201-208
    • /
    • 2002
  • In this paper, we present a new formulation using time-domain electric field integral equation (TD-EFIE) to obtain transient scattering response from arbitrarily shaped three-dimensional conducting bodies. The time derivative of the magnetic vector potential is approximated with a central finite difference and the scalar potential is time averaged by dividing it into two terms. This approach with an implicit method using central difference results in accurate and more stable transient scattering responses from conducting objects. Detailed mathematical steps are included and several numerical results are presented and compared with the inverse discrete Fourier transform (IDFT) of the frequency-domain solution.

S-Domain Equivalent System for Electromagnetic Transient Studies PART I : Frequency Dependent Network Equivalent (전자기 과도현상 해석을 위한 S 영역 등가시스템 PART I : 주파수 의존 시스템 등가)

  • 왕용필
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.11
    • /
    • pp.632-638
    • /
    • 2003
  • Modern power systems are very complex and to model them completely is impractical for electromagnetic transient studies. Therefore areas outside the immediate area of interest must be represented by some form of frequency dependent equivalent. The s-domain rational function form of frequency dependent equivalent does not need refitting if the simulation time-step is changed in the electromagnetic transient program. This is because the s-domain rational function coefficients are independent of the simulation time-step, unlike the z-domain rational function coefficients. S-domain rational function fitting techniques for representing frequency dependent equivalents have been developed using Least Squares Fitting(LSF). However it does not suffer the implementation error that exited in this work as it ignored the instantaneous term. This paper Presents the formulation for developing 1 Port Frequency Dependent Network Equivalent(FDNE) with the instantaneous term in S-domain and illustrates its use. This 1 port FDNE have been applied to the CIGRE Benchmark Rectifier test AC system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the 1 port (FDNE) developed with Thevenin and Norton Equivalent network. The study results have indicated the robustness and accuracy of 1 port FDNE for electromagnetic transient studies.

Digital Time-Domain Simulation of Ferroresonance of Potential Transformer in the 154 kV GAS Insulated Substation

  • Shim, Eung-Bo;Woo, Jung-Wook;Han, Sang-Ok
    • KIEE International Transactions on Power Engineering
    • /
    • v.11A no.4
    • /
    • pp.9-14
    • /
    • 2001
  • This paper reports a set of digital time-domain simulation studies conducted on 154 kV wound Potential Transformer(PT) int he 154 kV Gas Insulated Substation(GIS). The Electro-Magnetic Transient Program(EMTP) is used to develop the PT model and conduct the transient studies. The accuracy of the PT model is verified through comparison of the EMTP simulation results with those obtained from the field test results. The investigations shows that the developed model can accurately predict PT transient resonance, especially, the phenomenon of ferroresonance. The model is developed not only to determine impact of transients on PT response but also to design ferroresonance suppressor devices of PT. And it can also be used to predict PT transient response on power system monitoring and protection scheme.

  • PDF

Dynamic Analysis of 3-D Rigid Foundations by Boundary Elements (강성기초의 3차원 동적 경계요소해석)

  • Lee, Chan Woo;Kim, Moon Kyum;Hwang, Hak Joo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.5
    • /
    • pp.53-65
    • /
    • 1993
  • In this work the dynamic response of 3-D arbitrarily shaped rigid massless foundation is numerically obtained using boundary element under non-relaxed boundary condition. The problem is formulated in time domain by the boundary element method. The fundamental solutions used in this work are the Stokes solutions of the three dimensional elastodynamics. This method has advantages over frequency domain techniques in that it provides in a natural and direct way the time history of the response and forms the basis for elct:ension to nonlinear problems. This work is verified and can be used for practical purpose.

  • PDF

A Decision Support Systems Design for Process Control (공정통제용 의사결정지원 시스템)

  • 김정식
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.10 no.16
    • /
    • pp.39-51
    • /
    • 1987
  • This paper deals with the case analysis of second order processes under sampled-data. Proportional Integral-Derivative(PID) control, and development of Decision Support Systems(DSS) for such processes. In this paper three techniques were described for identifying the dynamics of closed loop stable processes. The first, called pulse testing is a frequency-domain method, which yields the frequency response diagram of an open loop process. The second is a time-domain method which yields the gain and time constants of the process model. The third technique is based on step response and gives the parameters of PID controllers. The development of DSS design programs consisting of above three techniques will provide very powerful tools in the microcomputer based process control.

  • PDF

A New Design Tool for PID and First Order Controllers in Parameter Space (ICCAS 2004)

  • Kim, Keun-Sik;Cho, Tae-Shin;Choi, Sun-Wook;Kim, Young-Chol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.8-13
    • /
    • 2004
  • In the paper, we present a practical design tool which allows us to design PID types and the first order lead/lag compensators incorporating the step response requirements in the stability. For a given plant transfer function of arbitrary order, this program provides a set of controller gains that satisfies both stability and time domain performances. This implies that even if one selects any controller parameters inside the set, the closed loop system with the controller gains meets the design objectives. This tool based on Matlab and GUI will be very useful for control design in the controller parameter space, especially when time domain requirement is given.

  • PDF

Equivalent Circuit Model for Four Port Connector System (4포트 커넥터 시스템의 등가회로 변환에 관한 연구)

  • Shim, Min-Kyu;Kim, Jong-Min;Nah, Wan-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1105-1110
    • /
    • 2007
  • This paper describes an equivalent circuit modeling of 4-port connector system. A coupled transmission line was designed and fabricated, mimicking a 4-port connector system, and then S-parameters were measured using 4 port VNA (Vector Network Analyzer). The S-parameters from measurement and from Full-wave simulator coincided quite nice. By using these S parameters, an equivalent circuit parameters for a 4-port system was obtained. The time domain response from the equivalent circuit model matched to the signals, which was measured using TDR(Time Domain Reflectometry) meter. We were also convinced that there should be enough bandwidth to get a meaningful time domain result from Fourier inverse transformation of the S parameters. In addition, we applied the conversion algorithm to the 4-port connector system, which calculates the S-parameters of a 4 port system using the data from a 2-port VNA with the other ports open. Comparison of the two data, one from measurement and the other one from the conversion algorithm, was made in this manuscript.

Nonlinear Hydroelastic Analysis Using a Time-domain Strip Theory m Regular Waves (규칙파중 시간영역 스트립이론을 이용한 비선형 유탄성 해석)

  • CHO IL-HYOUNG;HAN SUNG-KON;KWON SEUNG-MIN
    • Journal of Ocean Engineering and Technology
    • /
    • v.19 no.4 s.65
    • /
    • pp.1-8
    • /
    • 2005
  • A nonlinear time-domain strip theory for vertical wave loads and ship responses is to be investigated. The hydrodynamic memory effect is approximated by a higher order differential equation without convolution. The ship is modeled as a non-uniform Timoshenko beam. Numerical calculations are presented for the S175 Containership translating with the forward speed in regular waves. The approach described in this paper can be used in evaluating ship motions and wave loads in extreme wave conditions and validating nonlinear phenomena in ship design.