• Title/Summary/Keyword: Time Domain Reflectometry

Search Result 199, Processing Time 0.032 seconds

Development of Buried Type TDR Module for Leak Detection from Buried Pipe (매설관 주변부 누수 탐지를 위한 매설형 TDR 모듈 개발)

  • Hong, Wontaek
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.11
    • /
    • pp.31-37
    • /
    • 2021
  • To prevent accidents due to the cavities and loosened layers formed due to water leakage from the deteriorated buried pipes, evaluation of the changes in water contents around the buried pipes is required. As a method to evaluate the water contents of the soils, time domain reflectometry (TDR) system can be adopted. However, slender electrodes used in standard TDR probe may be damaged when buried in the ground. Thus, in this study, buried type TDR module was developed for the evaluation of the water contents with maintaining required shape of the electrodes in the ground. The TDR module is composed of three electrodes connected to the core conductor and outer conductor and a casing to prevent deformation and maintain alignment of the electrodes in the ground. For the verification of TDR waveforms measured using the TDR module, comparative analysis was conducted with the TDR waveforms measured using the standard TDR probe, and the relationship between the volumetric water content of the soils and the travel time of the guided electromagnetic wave was constructed. In addition, a model test was conducted to test the applicability of the buried type TDR module, and the experimental result shows that the TDR module clearly evaluates the changes in volumetric water contents due to the leakage from the modeled buried pipe. Therefore, the buried type TDR module may be effectively used for the health monitoring of the buried pipe and the evaluation of the water contents around the pipes buried in the urban pavements.

Detection and Location of Cable Fault Using Improved SSTDR (개선된 SSTDR을 이용한 케이블 고장 검출과 위치 계산)

  • Jeon, Jeong-Chay;Kim, Jae-Jin;Choi, Myeong-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.9
    • /
    • pp.1583-1589
    • /
    • 2016
  • This paper proposes an improved spread spectrum time domain reflectometry (ISSTDR) using time-frequency correlation and reference signal elimination method in order to have more accurate fault determination and location detection than conventional (SSTDR) despite increased signal attenuation due to the long distance to cable fault location. The proposed method has a two-step process: the first step is to detect a peak location of the reference signal using time-frequency correlation analysis, and the second step is to detect a peak location of the correlation coefficient of the reflected signal by removing the reference signal. The proposed method was validated through comparison with existing SSTDR methods in open-and short-circuit fault detection experiments of low voltage power cables. The experimental results showed that the proposed method can detect correlation coefficients at fault locations accurately despite reflected signal attenuation so that cable faults can be detected more accurately and clearly in comparison to existing methods.

Temperature Sensitivity Analysis of TDR Moisture Content Sensor for Road Pavement (도로하부 함수비 계측을 위한 TDR 방식 함수비 센서 온도 민감도 분석)

  • Cho, Myunghwan;Lee, Yoonhan;Kim, Nakseok;Jee, Keehwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.1
    • /
    • pp.329-336
    • /
    • 2013
  • The infrastructure of flexible pavement is composed of aggregate subbase, anti-frost layer, and subgrade. In particular, the subgrade performance is affected by climates such as frost action and precipitation. The method of TDR(Time Domain Reflectometry) sensors to measure moisture contents in subgrade layer has been used in the research. Due to the TDR method using dielectric permitivity of soil and water, the sensors can be affected by the low subgrade temperatures. The air temperatures frequently drops below $-20^{\circ}C$ in the winter in Korea. As a result, it is necessary to estimate the accuracy of the TDR moisture sensors in the range of below zero temperatures. In this study, the subgrade temperatures of lower than $-2^{\circ}C$ were extended to evaluate temperature sensitivity of the TDR moisture sensors. The test results revealed that the moisture contents around the sensors were reduced while those of the upper part of specimen showed a tendency to increase as the specimen surface temperature drops below zero under the volumetric moisture contents(VMC) of 20% and 30%. However, the impact of temperature on the function of the sensor at lower water contents was found to be negligible if any.

Soil Moisture Monitoring at a Hillslope Scale Considering Spatial-Temporal Characteristics (봄, 가을철 시공간적 특성을 고려한 사면에서의 토양수분 거동파악)

  • Oh Kyoung-Joon;Lee Hye-Sun;Kim Do-Hoon;Kim Hyun-Jun;Kim Nam-Won;Kim Sang-Hyun
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.7 s.168
    • /
    • pp.605-615
    • /
    • 2006
  • In order to analyze movement of soil moisture, Time Domain Reflectometry(TDR) with multiplex system has been installed at the Bumreunsa hillslope of Sulmachun Watershed to configure spatial-temporal variation pattern considering seasonal characteristic. An intensive surveying was performed to build a refined digital elevation model(DEM) and flow determination algorithms with inverse surveying have been applied to establish an efficient soil moisture monitoring system. Soil moisture data were collected through an intensive and long term monitoring 380 hrs in November of 2003 and 1037 hrs in May and June of 2004. Soil moisture data shows corresponding variation characteristics of soil moisture on the up slope, buffer, main channel zones of the hillslope which were classified from terrain analysis. Measured soil moisture data were discussed in conjunction with flow characteristic through terrain analysis. Regardless season, immediate responses of soil moisture about rainfall looks similar but recession and recharge are primary characteristics of intermediate soil moisture variation for spring to summer and fall to winter season, respectively.

A Study on the Applicability of Levee Leakage Monitoring System Using Movable TDR Sensor (제방 누수 모니터링을 위한 이동식 TDR 센서의 적용성 평가)

  • Cho, Jinwoo;Choi, Bong-Hyuck;Cho, Won-Beom;Kim, Jin-Man
    • Journal of the Korean Geosynthetics Society
    • /
    • v.13 no.3
    • /
    • pp.1-10
    • /
    • 2014
  • Several types of methods such as resistivity survey, ground penetration radar, etc are used for detection of levee leakage and according to the river design guidelines detection of levee leakage is performed by measuring the hydraulic conductivity of levee soil. But, the former can not verify the leakage point and degree of saturation, the latter is an after treatment method. Movable sensor, which is a high-tech TDR system developed since 2000, can obtain directly the dielectric constant profile covering the whole depth of levee. In this study, laboratory and field model experiments were carried out using movable TDR sensor in order to evaluate the applicability as detection system of levee leakage, As the result, movable TDR system has proven to be 3 times more sensitive to water contents than dry unit weight, and the results conclude that the dielectric constant, water contents and density of the ground proved to have a correlation among them, and the dielectric constant is expected to be a basic data on detection of levee leakage.

Development of intrusion detection technique using fiber optic ROTDR sensor (광섬유 ROTDR 센서를 이용한 침입 탐지기법의 개발)

  • Baik, Se-Jong;Kwon, Il-Bum;Chung, Chul;Yu, Jae-Wang
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.209-217
    • /
    • 2002
  • The developing of buried fiber optic sensor with high sensitivity and broad-area detecting intruders is carried out using fiber optic ROTDR(Rayleigh Optical Time Domain Reflectometry). The sensing part was designed to be able to broad-area detect intrusion effect per optical fiber length under ground. The bending light losses in optical fibers are investigated by commercial mini ROTDR with wavelength $1.55{\mu}m$, distance range 5km, pulse width 20ns, SNR=5.7. The sensing fibers are selected as the common telecommunication fibers are the 1.5mm, 3.5 mm outer diameter, 4km each length fiber products. Experiments were investigate the characteristics of signal sensitivity according to applied intrusion weight. The relation between the applied weight and the bending loss was almost linear, and broad-area detect intrusion effects are the 2m resolution and $1.3m^2$ per optical fiber length respectively. The light loss by the applied weight on fiber was 0.17 dB/kg. that the sensitivity of the optical fiber sensor was sufficient to detect intruders passing over the buried optical fiber.

Experimental Study of Solute Transport in the Unsaturated Zone by using TDR (TDR(Time Domain Reflectometry)을 이용한 비포화영역에서 용존오염원의 거동에 관한 실험적 연구)

  • Park, Jae-Hyeon;Seo, Il-Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 1998.05a
    • /
    • pp.395-403
    • /
    • 1998
  • 오염원의 이송확산에 관한 많은 연구들이 수행되어 왔으나 특히 비포화 영역에서 오염원 이송확산을 측정하는 것은 매우 어려운 것으로 알려지고 있다. 비포화 토양에서의 오염원 이송확산은 매질의 함수량 변화에 영향을 받기 때문에 오염원 거동특성을 이해하려면 비포화 흐름 분석을 선행한 후 오염원의 이송확산 특성을 분석하여야 한다. 본 연구에서는 비포화 영역에서의 오염원 이송특성을 분석하기 위하여 TDR(Time Domain Reflectometry)을 이용하여 비포화 흐름 및 오염원 이송을 측정하였다. 이를 위하여 본 연구에서는 TDR을 이용하여 오염원 이송을 측정하는 방법을 개발하였으며, 이 방법을 이용하여 1차원의 토양기둥시료에서 비포화 흐름 및 오염원 이송확산에 관한 실험을 수행하고 수치모형을 적용함으로써 비포화 영역에서 오염원의 이송확산에 관한 거동특성을 규명하였다. 본 연구에서는 두 종류의 국내 토양시료(SUS, KUS)를 사용하였는데, 토양의 물리적 특성을 예비실험을 통하여 규명한 후 토양기둥시료를 이용한 본실험을 수행하였다. 비포화 천이흐름하의 오염원 이송확산 실험에서는 급격한 습윤전선의 전진에 따른 종형의 함수량변화를 관측할 수 있었고, 이때 오염원의 농도는 함수량의 천이구간의 중심점으로부터 전방영역의 농도분포가 습윤전선에서의 함수량 분포와 유사한 종형을 이루고 있음을 관측할 수 있었다. 비포화 정상흐름하의 오염원 이송확산 실험에서는 오염원이 이송하며 농도 천이구간이 확장되어지는 전형적인 형태를 보였다. 또한 예비실험에서 측정한 매개변수를 입력자료로하여 수행한 수치결과와 실험결과를 비교하였는데 비포화 흐름특성은 실험결과와 수치결과가 정량적으로 일치하는 경향을 보였으나, 오염원 이송확산 특성은 정량적으로 수치결과가 실험결과보다 더 많이 확산되는 경향을 보였다. 따라서 수치모형을 현장에 적용할 경우 확산지수 결정에 주의하여야 할 것으로 판단된다. 즉, 수치모형에 적용할 확산지수는 BTC 실험을 통하여 측정한 확산지수, 수치확산, 흡착계수, 적용영역의 크기 등을 고려하여 결정하여야 한다. 특히 본 논문에서는 TDR을 이용하여 최초로 천이상태의 함수량과 오염원 농도를 측정하였는데 이를 위하여 전기전도도와 함수량관계를 추정하는 식을 제안하였으며, 전기전도도와 토양수 농도, 전기전도도와 함수량의 관계를 이용한 천이상태의 오염원 농도 측정방법을 개발하였다. 특히 제안식에서는 한계함수량의 개념을 도입하여 전기전도도와 함수량관계를 추정하므로 추정식의 실험값 반영 정도를 증가시켰다. 본 연구에서 제안된 식을 이용하여 추정된 전기전도도와 함수량관계는 다른 제안식에 비하여 개선된 결과를 보여 주었고, 본 연구에서 개발한 오염원 농도 측정법을 이용하여 측정한 결과 함수량이 0.15이하에서는 측정오차가 크지만 함수량이 0.15이상일 경우 매우 좋은 결과를 보였는데 질량평형을 검토한 결과 약 5-10%의 오차율을 보였다. 따라서 본 논문에서 개발된 천이상태의 오염원 농도측정법은 용존 오염물질의 이송에 관한 정확한 실험을 제공할 것으로 판단된다.

  • PDF

Spatial Distribution of Macropore Development on a Hillslope (소유역의 사면에서의 대공극발달의 공간적 분포)

  • Kwak, Yong-Seok;Kim, Sang-Hyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.825-830
    • /
    • 2007
  • 사면에서 발생되는 강우유출과정에 기여하는 대공극의 영향은 그 중요성에도 불구하고 잘 알려져 있지 않다. 특히 대공극의 공간적분포특상에 대한 현장측정은 이뤄지지 않았다. 본 연구의 실험지역은 경기도 포천시 광릉수목원에 있는 작은 소유역이다. 이 지역의 정밀한 측량을 하여 수치고도모형(DEM)을 얻었다. 이 수치고도모형을 바탕으로 수치지형분석을 통해 흐름선을 파악하여 총 20지점을 선정하였다. 각 지점에서의 대공극을 통한 수직적인 유동들은 장력침투계를 사용하여 지표면아래 깊이 10cm에서 측정하였다. 공간적 토양의 특성분포를 파악하기 위해 각 지점에서의 체적밀도와 점토함량을 조사하였다. 토양수분의 공간적 분포 특성은 TDR(Time Domain Reflectometry)방식인 TRASE를 이용하여 토양수분 값을 얻었다. 이러한 다양한 공간적 특성들은 대공극발달의 공간적 분포특성을 파악하는 중요자료가 된다. 소유역을 크게 기여사면 면적을 기준으로 상부, 중부, 하부로 나누어 대공극의 유효 공극율과 대공극흐름율을 계산하였다. 상부에서의 유효 대공극율의 평균값과 변동계수는 각각 4.3%, 42.1%이고, 대공극흐름율의 평균값과 변동계수는 각각 45.0%, 26.6%이다. 중부에서는 유효 대공극율의 평균값과 변동계수는 6.8%, 37.3%이고, 대공극흐름율의 평균값과 변동계수는 56.2%, 14.4% 이다. 그리고 하부에서의 유효공극율의 평균값과 변동계수는 12.5%, 58.3% 이고 대공극흐름율의 평균값과 변동계수는 64.5%, 24%이다. 이는 유효 대공극율과 대공극흐름율의 비율은 기여사면 면적이 증가할수록 증가하였다. 이는 대공극을 통한 물 이송 능력이 원두부로 갈수록 증가한다는 것을 보여주고 있다.e, taurine, methionine, phenylalanine은 함량(含量)이 적었다. 5. 일건(日乾)중 총유리아미노산의 변화(變化)는 생시료(生試料)의 경우 2,041.2 mg%였으나 1일(日) 건조(乾燥) 후는 1,784.0 mg%로 감소(減少)하다가 그 이후 계속 증가(增加)하여 20일(日) 건조(乾燥) 후는 5,277.0 mg%였다. 6. 일건(日乾)중 leucine, isoleucine, valine은 대체로 증가(增加)하는 경향(傾向)을 나타내었으나 aspartic acid, proline, taurine은 대체로 감소(減少)하는 경향(傾向)을 나타내었다. 436.59mg%로 가장 많았고 군유산(軍有山) 차엽(茶葉)이 146.94mg%로 가장 적었으며 일반차엽(一般茶葉)의 평균치(平均値)는 264.59mg%, 용장(龍欌) 차엽(茶葉)이 223.10mg%, Yabukita 차엽(茶葉)이 256.49mg%였다. 7) 이상(以上)의 결과(結果)를 종합(綜合)할 때 용장(龍欌) 차엽(茶葉)은 일반차엽(一般茶葉)과 형질(形質) 뿐만 아니라, 성분(成分)도 다르므로 품종(品種)이 다른 수종(樹種)으로 추정(推定)되며 와운(臥雲) 차엽(茶葉)은 일반차엽(一般茶葉)과 형질(形質)은 다르나 성분상(成分上)의 비슷한 점으로 보아 동일계통(同一系統)의 변이(變異)된 대엽종(大葉種)으로 추정(推定)된다.5(${\pm}0.77$0.77) % 의 오차로 크게 감소하였다. 결론: 방사선이 통과하는 경로에 불균질조직인 폐가 존재할 경우에도 불균질조직에 대하여 조직의 밀도를 이용하여 보정하는 방법을 사용하여 투과선량으로부터 종양선량을 계산할 수 있음을 알 수 있었다.X>로 평균$43.26{\m

  • PDF

Evaluation of Oil Infiltration Behavior in Porous Media Using Dielectric Response (유전율에 의한 지반 매질내 유류침투거동 분석)

  • Kim Man-Il;Jeong Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.15 no.1
    • /
    • pp.29-39
    • /
    • 2005
  • For detecting a ground contamination survey, soil sampling method have been used a drilling or coring technique in general. However these methods are very difficult to systematically real-time monitoring of variation of contamination degree in field. ]'n this research frequency Domain Reflectometry (FDR) system was suggested and carried out to experimental approaches for determination of oil contamination on surface and underground. Experimental method using FDR method was discussed with feasibility of measurement in the laboratory column test. It is determined to degree of oil contamination due to response of dielectric constant re-lated with volumetric water content(θ/sub w/) and volumetric oil content( θ/sub al/ ) of saturated and unsaturated soil media. And physical properties such as effective porosity and oil residual ratio of saturated soil media were also measured through real-time monitoring works using installed FDR measurement sensors, which are defected characteristics of oil movement in the saturated soil media under the soil column tests. In the results of these experiments, a range of effective porosity was estimated to about 0.35 compared with initial porosity 0.40 of manufactured saturated soil media, which is also calculated to about 87.5% to the ratio of initial porosity to effective porosity. Finally oil residual ratio which is compared with volumetric water content and volumetric oil content was calculated about 62.5%.

Analysis of Sand Water Ratio and Drying Unit Weight Using Flat TDR System (Flat TDR 시스템을 이용한 모래의 함수비와 건조단위중량 분석)

  • Lee, Junesung;Kim, Daehyeon
    • The Journal of Engineering Geology
    • /
    • v.31 no.3
    • /
    • pp.333-342
    • /
    • 2021
  • In this study was conducted to measure the water content and dry unit weight of the ground using TDR (Time Domain Reflectometry) in order to supplement the problems of the conventional compaction management method. The Flat TDR system is a device that does not cause ground disturbance, and in order to verify the measured values, the dry density and water content were measured for samples of the ground subject at 7 sites other than Jumunjin Standard Temple. The water content section was divided into 6 sections of 3, 6, 9, 12, 15, and 18%, and the experimental results were confirmed according to the unified classification method. As a result of the indoor experiment, the water content showed an error of about 0.7% for the SP sample and about 1.3% for the SM sample. In addition, the dry unit weight confirmed an error of about 7% for the SP sample and about 5% for the SM sample. It was confirmed that stable values were derived in sandy or silty sandy ground except for clay or gravel. Through the experimental results, it was confirmed that the measured values of the flat TDR system derive similar values to the existing traditional compaction management method, and it was determined that the flat TDR equipment was suitable for construction sites that require quick constructability and economic feasibility.