• Title/Summary/Keyword: Time Division

Search Result 12,118, Processing Time 0.038 seconds

Time Reversal Beam Focusing of Ultrasonic Array Transducer on a Defect in a Two Layer Medium

  • Jeong, Hyun-Jo;Lee, Jeong-Sik;Bae, Sung-Min
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.3
    • /
    • pp.242-247
    • /
    • 2009
  • The ability of time reversal techniques to focus ultrasonic beams on the source location is important in many aspects of ultrasonic nondestructive evaluation. In this paper, we investigate the time reversal beam focusing of ultrasonic array sensors on a defect in layered media. Numerical modeling is performed using the commercially available software which employs a time domain finite difference method. Two different time reversal approaches are considered - the through transmission and the pulse-echo. Linear array sensors composed of N elements of line sources are used for signal reception/excitation, time reversal, and reemission in time reversal processes associated with the scattering source of a side-drilled hole located in the second layer of two layer structure. The simulation results demonstrate the time reversal focusing even with multiple reflections from the interface of layered structure. We examine the focusing resolution that is related to the propagation distance, the size of array sensor and the wavelength.

Quantifiable and feasible estrus detection using the ultrasonic sensor array and digital infrared thermography

  • Lee, Ji Hwan;Lee, Dong Hoon;Yun, Won;Oh, Han Jin;An, Ji Seon;Kim, Young Gwang;Kim, Gok Mi;Cho, Jin Ho
    • Journal of Animal Science and Technology
    • /
    • v.61 no.3
    • /
    • pp.163-169
    • /
    • 2019
  • Detection of estrus is an essential factor as a method of successful breeding in the sow. As increasing the adaption of the information and communication technology (ICT) into swine industry, this study focuses on a possibility and quantification of standing time, vulva and body temperature as methods of estrus detection, comparing each time and temperature in estrus and non-estrus period, and analyzing each success rate of new and existing methods. Ultrasonic sensor array and digital infrared thermography were used to evaluate whether new methods such as standing time and number, and vulva and skin temperature can be replaced, or these methods can be quantifiable in estrus period. Ultrasonic sensor array was installed beside the stall and digital infrared thermography was placed in the rear of sow to collect the dates of sow in estrus and non-estrus period. This study showed total standing time, number and number over 10 minutes, and vulva temperature of the sow in estrus period were increased (p < 0.05) compared with those of sow in non-estrus period, respectively. Detection of estrus using standing time and vulva temperature tended (p = 0.06) to increase the success rate when artificial insemination (AI) was performed. In conclusion, standing time and vulva temperature increased when estrus happened. Success rate of AI of sow using these methods showed an increasing trend. Therefore, existing method using the naked eye can be replaced to new method such as vulvar temperature and standing time when detecting the estrus.

Optimization of Robot Welding Process of Subassembly Using Genetic Algorithm in the Shipbuilding (유전자 알고리즘을 이용한 조선 소조립 로봇용접공정의 최적화)

  • Park, Ju-Yong;Seo, Jeong-Jin;Kang, Hyun-Jin
    • Journal of Welding and Joining
    • /
    • v.27 no.2
    • /
    • pp.57-62
    • /
    • 2009
  • This research was carried out to improve the productivity in the subassembly process of shipbuilding through optimal work planning for the shortest work time. The work time consist of welding time, moving time of gantry, teaching time of robot and robot motion time. The shortest work time is accomplished by even distribution of work and the shortest welding sequence. Even distribution of work was done by appling the simple algorithm. The shortest work sequence was determined by using GA. The optimal work planning decreased the total work time of the subassembly process by 4.1%. The result showed the effectiveness of the suggested simple algorithm for even distribution of work and GA for the shortest welding sequence.

Methodology for Extracting Trap Depth using Statistical RTS Noise Data of Capture and Emission Time Constant

  • Oh, Dong-Jun;Kwon, Sung-Kyu;Song, Hyeong-Sub;Kim, So-Yeong;Lee, Ga-Won;Lee, Hi-Deok
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.2
    • /
    • pp.252-259
    • /
    • 2017
  • In this paper, we propose a novel method for extracting an accurate depth of a trap that causes RTS(Random Telegraph Signal) noise. The error rates of the trap depth rely on the mean time constants and its ratio. Here, we determined how many data of the capture and emission time constant are necessary in order to reduce the trap depth error caused by an inaccurate mean time constant. We measured the capture and emission time constants up to 100,000 times in order to ensure that the samples had statistical meaning. As a result, we demonstrated that at least 1,000 samples are necessary to satisfy less than 10% error for trap depth. This result could be used to improve the accuracy of RTS noise analysis.

Imaging of a Defect in Thin Plates Using the Time Reversal of Single Mode Lamb Wave: Simulation

  • Jeong, Hyun-Jo;Lee, Jung-Sik;Bae, Sung-Min;Lee, Hyun-Ki
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.3
    • /
    • pp.261-270
    • /
    • 2010
  • This paper presents an analytical investigation for a baseline-free imaging of a defect in plate-like structures using the time-reversal of Lamb waves. We first consider the flexural wave (A0 mode) propagation in a plate containing a defect, and reception and time reversal process of the output signal at the receiver. The received output signal is then composed of two parts: a directly propagated wave and a scattered wave from the defect. The time reversal of these waves recovers the original input signal, and produces two additional side bands that contain the time-of-flight information on the defect location. One of the side band signals is then extracted as a pure defect signal. A defect localization image is then constructed from a beamforming technique based on the time-frequency analysis of the side band signal for each transducer pair in a network of sensors. The simulation results show that the proposed scheme enables the accurate, baseline-free detection of a defect, so that experimental studies are needed to verify the proposed method and to be applied to real structure.

Variation in Residence Time and Water Exchange Rate by Release Time of Pollutants Over a Tidal Cycle in Masan Bay (조석 주기별 오염물질 방출에 따른 마산만의 체류시간 및 해수교환율 변화)

  • Park, Sung-Eun;Lee, Won-Chan;Hong, Sok-Jin;Kim, Hyung-Chul;Kim, Jin-Ho
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.14 no.4
    • /
    • pp.249-256
    • /
    • 2011
  • Lagrangian particle transport model coupled with the EFDC have been performed to estimate the residence time and water exchange rate by release time of pollutants over a tidal cycle in Masan Bay. The modelled residence time for the whole bay was about 40 days, ranging from less than 20 days in the southern parts of Budo, to over 100 days in the upper parts of Somodo. The spatial difference of residence time was controlled by tidal residual currents and the distance to the bay channel. The area mean residence time during spring and neap tides was estimated to be about 36 days and 42 days, respectively. The time required for 30% exchange of water was calculated as ranging from 65 to 105 days by release time of pollutants.

Predictors of Small Bowel Transit Time for Capsule Endoscopy in Children with Inflammatory Bowel Disease

  • Itsuhiro Oka;Rie Funayama;Hirotaka Shimizu;Ichiro Takeuchi;Shuko Nojiri;Toshiaki Shimizu;Katsuhiro Arai
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.26 no.4
    • /
    • pp.181-192
    • /
    • 2023
  • Purpose: The development of assistive devices has allowed for the performance of capsule endoscopy in children. Anticipating the capsule's transit time could affect the efficacy of the investigation and potentially minimize the fasting period. This study determined the predictors of small bowel transit time for small-bowel capsule endoscopy in children and adolescents with inflammatory bowel disease. Methods: We retrospectively examined children and adolescents with inflammatory bowel disease who underwent capsule endoscopy by the age 18 at a Japanese tertiary care children's hospital. Small bowel transit time predictors were analyzed using multiple regression with explanatory variables. Results: Overall, 92 patients, aged 1-17 years, with inflammatory bowel disease (63 Crohn's disease and 29 ulcerative colitis cases) were examined for factors affecting small bowel transit time. In the simple regression analysis, diagnosis, age, height, weight, serum albumin, general anesthesia, and small intestine lesions were significantly associated with small bowel transit time. In the multiple regression analyses, serum albumin (partial regression coefficient: -58.9, p=0.008), general anesthesia (partial regression coefficient: 127, p<0.001), and small intestine lesions (partial regression coefficient: 30.1, p=0.037) showed significant associations with small bowel transit time. Conclusion: Hypoalbuminemia, the use of general anesthesia for endoscopic delivery of the capsule, and small intestine lesions appeared to be predictors of prolonged small bowel transit time in children and adolescents with inflammatory bowel disease. Expecting the finishing time may improve examination with a fasting period reduction, which benefits both patients and caregivers.

Development of a New Duplex Real-Time Polymerase Chain Reaction Assay for Detection of Dicer in G. gallus

  • Ji, Xiaolin;Wang, Qi;Gao, Yulong;Wang, Yongqiang;Qin, Liting;Qi, Xiaole;Gao, Honglei;Wang, Xiaomei
    • Journal of Microbiology and Biotechnology
    • /
    • v.23 no.5
    • /
    • pp.630-636
    • /
    • 2013
  • Recently, there has been a growing body of evidence showing that cellular microRNAs (miRNAs) are involved in virus-host interactions. Numerous studies have focused on analyses of the expression profiles of cellular miRNAs, but the expression patterns of Dicer, which is responsible for the generation of miRNAs, have only rarely been explored in Gallus gallus. We developed a duplex real-time reverse transcriptase polymerase chain reaction (RT-PCR) assay for the relative quantification of the mRNAs of Dicer and ${\beta}$-actin in G. gallus. To apply this method, the expression of Dicer in avian cells after infection with avian leukosis virus subgroup J (ALV-J) was detected using our established duplex real-time RT-PCR. The duplex real-time RT-PCR assay is sufficiently sensitive, specific, accurate, reproducible, and cost-effective for the detection of Dicer in G. gallus. Furthermore, this study, for the first time, demonstrated that ALV-J can induce differential expression of Dicer mRNA in the ALV-J-infected cells.

Identification of Brucella melitensis isolates originating from Mongolia and diagnostic real-time PCR evaluation using a specific SNP (몽골 유래 Brucella melitensis 동정 및 특이 SNP를 이용한 real-time PCR법에 의한 진단 평가)

  • Kang, Sung-Il;Kim, Ji-Yeon;Kim, Suk Mi;Lee, Jin Ju;Sung, So-Ra;Kim, Yeon-Hee;Jung, Suk Chan;Her, Moon
    • Korean Journal of Veterinary Research
    • /
    • v.55 no.2
    • /
    • pp.105-110
    • /
    • 2015
  • A real-time PCR assay using hybridization probe (HybProbe) has been developed to detect Brucella (B.) melitensis strains. The primer and HybProbe sets were designed based on the gap gene of chromosome I with a specific single nucleotide polymorphism of B. melitensis. Specificity of the assay was confirmed by comparison to reference Brucella species and other related strains. In the melting curve analysis, B. melitensis generated a peak at $67^{\circ}C$ unlike those for other Brucella species observed at $61^{\circ}C$. Sensitivity of the assay for B. melitensis ranged from 20 ng to 200 fg of genomic DNA. The ability to identify 94 Mongolian B. melitensis isolates using the real-time PCR assay was identical to that of classical biotyping methods and differential multiplex PCR. These data showed that this new molecular technique is a simple and quick method for detecting B. melitensis, which will be important for the control and prevention of brucellosis.

Delay Time Estimation in Frequency Selective Fading Channels

  • Lee Kwan-Houng;Song Woo-Young
    • Journal of information and communication convergence engineering
    • /
    • v.3 no.3
    • /
    • pp.119-121
    • /
    • 2005
  • This paper aims to estimate the delay time of multiple signals in a multi-path environment. It also seeks to carry out a comparative analysis with the existing delay time under the proposed algorithm to develop a new algorithm that applies the space average method in a MUSIC algorithm. Unlike the existing delay time estimation algorithm, the developed algorithm was able to estimate the delay time in 5ns low. Therefore, the algorithm proposed in this paper improved the existing delay time estimated algorithm.