• Title/Summary/Keyword: Time Difference

Search Result 14,184, Processing Time 0.038 seconds

A Comparative Study on Closed vs. Open Endotracheal Suctioning on the Newborn Infants Treated with Ventilator (인공호흡기 사용 신생아의 폐쇄형과 개방형 기관흡인에 관한 연구)

  • Park, Jeong-Won;Park, Yeong-Ae
    • 아동간호학회:학술대회논문집
    • /
    • 1997.11a
    • /
    • pp.61-74
    • /
    • 1997
  • Endotracheal suctioning is a routine procedure used for clearing secretions from the airway of the intubated infant. This procedure is not without complications. Endotracheal suctioning has been associated with decreases in $PaO_2$, decreases in systemic venous oxygenation, alterations in mean arterial Pressure, disturbances in cardiac rhythm and development of nosocomial pneumonia. So several endotracheal suctioning techniques have been developed to prevent these blown complications. Another method of Endotracheal suctioning eliminates the risk associated with disconnecting the infant from the ventilatior to perform the suctioning procedure. Studies examining closed endotracheal suctioning methods reported that the closed method results in less arterial oxygen saturation, and less systemic venous oxygen desaturation. However those studies have focused on adult patients, and there have been no published studies for newborn infants. The specific purpose of this study is to investigate the two methods and to make a comparison in terms of (1)variations in $SaO_2$, heart rate, and respiration rate appeared before and after the endotracheal suctioning; (2)difference in occurrence of nosocomial infection; (3)difference in recovery time to arrive at pre-suction baseline after suctioning and in nursing time taken for the suctioning. The present study is based on the data obtained from two groups of newborn infants : one group comprises 8 infants with closed suctioning (a total of 304 suctions) among 17 infants treated with ventilator and the other group 9 infants with open method (a total of 629 suctions). The data were analyzed using the SPSS statistical program package. As the distribution test on dependent variables with the Skewnesser Shapiro Wilk test showed an asymmetric distribution, the Wilcoxon Matched-pairs Singled- Ranks test was used for the test of variations in $SaO_2$, heart rate, and respiration rate appeared before and after the endotracheal suctioning. The difference in $SaO_2$ recovery time and nursing time was analyzed with the Mann-Whitney U-Test. The difference in physiologic consequences and occurrence of nosocomial infection between the two groups was analyzed with the Fisher's Exact Test. The results of the study are summarized as follows. For the hypothesis 1 (There would be a difference in $SaO_2$, heart rate, and respiration rate before and after suctioning between the two suctioning methods), the difference in $SaO_2$ turns out to be statistically significant (P=0.015), but heart rate and respiration rate do not procedure a notable difference (P=0.630). The hypothesis 2 (There would be a difference in rates at which a complication arises after suctioning between the two groups) does not prove to be statistically valid (P=0.246). For the hypothesis 3(There would be a difference in $SaO_2$ recovery time and nursing time between the two groups), the average $SaO_2$ recovery time after suctioning turned out to have somewhat significant difference (P=0.064), however the difference in nursing time taken for the suctioning was not statistically significant (P=0.610). The analyses indicate that the closed endotracheal suctioning is more efficient as compared with the open method, in maintaining pre-suction baseline $SaO_2$ and a rapid recovery of newborn infants. Based on these results we suggust to apply the closed method to newborn infants in the ventilation treatment. We also suggest to extend the investigation to include the comparison of suction cost taking into account the case in which a complication arises after endotracheal suctioning between the two groups.

  • PDF

A FOURTH-ORDER ACCURATE FINITE DIFFERENCE SCHEME FOR THE EXTENDED-FISHER-KOLMOGOROV EQUATION

  • Kadri, Tlili;Omrani, Khaled
    • Bulletin of the Korean Mathematical Society
    • /
    • v.55 no.1
    • /
    • pp.297-310
    • /
    • 2018
  • In this paper, a nonlinear high-order difference scheme is proposed to solve the Extended-Fisher-Kolmogorov equation. The existence, uniqueness of difference solution and priori estimates are obtained. Furthermore, the convergence of the difference scheme is proved by utilizing the energy method to be of fourth-order in space and second-order in time in the discrete $L^{\infty}-norm$. Some numerical examples are given in order to validate the theoretical results.

Field Application of Mass Concrete Using Setting Time Difference of Super Retarding Agent for Reduction of Hydration Heat (초지연제의 응결시간차를 이용한 매스 콘크리트의 수화열 저감을 위한 현장 적용)

  • 전충근;심보길;손성운;신동안;오선교;한천구
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2004.05a
    • /
    • pp.11-14
    • /
    • 2004
  • In this paper, field application of mass concrete using setting time difference of super retarding agent is reported to reduce hydration heat of concrete placed at newly constructed apartment house in Busan. Horizontal placing lift is applied. According to test results. slump and air content meets the requirement of target values. For compressive strength, it exceeds the nominal strength ordered by the costumer. Compressive strength of concrete cured in place is achieved more than the values of nominal strength at l4days. For temperature history, maximum temperature of center at top section shows 58.5$^{\circ}C$, and at bottom section, 62.6$^{\circ}C$. According to naked eye's investigation, no hydration heat crack is observed at the surface of concrete.

  • PDF

Finite Difference Time Domain Analysis for Film Bulk Acoustic Wave Resonator used in Microwave Region (시간 영역 유한 차분법(FDTD)을 이용한 마이크로파 대역의 압전 박막 공진기 해석)

  • 송영민;정재호;이용현;이정희;최현철
    • Proceedings of the IEEK Conference
    • /
    • 2000.11a
    • /
    • pp.489-492
    • /
    • 2000
  • Film Bulk Acoustic Wave Resonator(FBAR) used in microwave region was analyzed with Finite Difference Time-Domain Methods(FDTD) in this paper. FBAR have been analyzed with one dimensional Mason model analysis or Finite Element methods(FEM), but the first couldn't analyze effect of area variation and spurious characteristics, the second had difficulty in element separation because of thin electrode. So in this paper FBAR was analyzed by Finite Difference Time-Domain Methods and it's results were transformed to frequency domain using Discrete Fourier Transform.

  • PDF

Analysis of Coaxial Line Transmission Charactristics and Shielding Effectiveness Using by Finite Difference Time Domain Method (시간영역 유한차분법을 이용한 동축선로의 전송특성 및 차폐효과 해석)

  • 남상식;윤현보;김정렬;백낙준;우종우
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.6 no.4
    • /
    • pp.11-19
    • /
    • 1995
  • In this paper, the Finite Difference Time Domain (FDTD) method is used to analyse the characteristics of the coaxial line transmission coefficent, shielding effectiveness, and compared to results of the moment method. The excitation mode of the Gaussian pulse is assumed to be a TEM-mode instead of the TE or TM-mode and in order to eliminate the reflected wave with in short length of the line. Calculated value of shielding effectiveness of the coaxial line by the FDTD are in good agreement with the results of the moment method.

  • PDF

A Study on the Wet Type Ultrasonic Flow-meter System Development (습식방식의 초음파 유량계 시스템 개발에 관한 연구)

  • Lee Eung-Suk;Kwon Oh-Hoon;Rho Myung-Hwan;Lee Hyung-Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.12 s.243
    • /
    • pp.1638-1644
    • /
    • 2005
  • This paper suggests fur the study on a fluid velocity measuring system using ultrasonic transducer. In general, the time difference method to measure the distance between transducers has been known. In this paper, the practical technology for manufacturing ultrasonic flow meter system is studied using the time difference method. The ultrasonic transducer was designed and manufactured. The transmission and receiving algorithm for ultrasonic signal was studied. The ultrasonic flow measuring system was experimented in laboratory using a water reservoir for verifying the distance measuring accuracy. Finally, it was tested in flow calibration laboratory for the velocity measuring performance. The system, designed in this study, showed 0.3 mm resolution in distance measurement. For precise flow measurement, a high speed triggering algorithm is required for ultrasonic signal receiving.

Field Application of Setting Time Difference Method Using SRA for Reduction of Hydration Heat of Mass Concrete (매스콘크리트의 수화열저감을 위한 초지연제 응결시간차 공법의 현장 적용 -대전 가오지구 코오롱 하늘채 아파트 현장-)

  • Jeon Chung-Keun;Kim Jong;Shin Dong-An;Yoon Gi-Won;Oh Seon-Gyo;Han Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.21-24
    • /
    • 2005
  • In this paper, field application of mass concrete using setting time difference of super retarding agent is reported to reduce hydration heat of concrete placed at newly constructed apartment house in Daejeon. Horizontal placing lift is applied. According to test results,: slump and air content meets the requirement of target values. For compressive strength, it exceeds the nominal strength ordered by the costumer. For temperature history, maximum temperature of center at top section shows $25.6^{\circ}C$, and at bottom section, $35.4^{\circ}C$. According to naked eye's investigation, no hydration heat crack is observed at the surface of concrete.

  • PDF

Generation of Non-uniform Meshes for Finite-Difference Time-Domain Simulations

  • Kim, Hyeong-Seok;Ihm, In-Sung;Choi, Kyung
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.128-132
    • /
    • 2011
  • In this paper, two automatic mesh generation algorithms are presented. The methods seek to optimize mesh density with regard to geometries exhibiting both fine and coarse physical structures. When generating meshes, the algorithms attempt to satisfy the conditions on the maximum mesh spacing and the maximum grading ratio simultaneously. Both algorithms successfully produce non-uniform meshes that satisfy the requirements for finite-difference time-domain simulations of microwave components. Additionally, an algorithm successfully generates a minimum number of grid points while maintaining the simulation accuracy.

Analysis of Surface Color Characteristics of Wood in Accelerated Weathering Test (촉진열화실험에 따른 목재 부재의 재색 특성 분석)

  • Kim, Gwang-Chul;Park, Chun-Young
    • Journal of the Korea Furniture Society
    • /
    • v.26 no.3
    • /
    • pp.262-266
    • /
    • 2015
  • This study was carried out to analyze the surface color change according to the weathering time. The surface color of material was one of evaluation indexes in exposure experiment. For the purpose, accelerated weathering test was performed with wood. The weathering time level was composed with 0, 500, 1000, 1500 and 2000 hours and color difference was estimated with the color difference meter. The surface color was changed to 500 hours that lightness and redness were decreased and yellowness was increased. However it did not changed after 500 hours. It means that the surface color could be the evaluation index of deterioration of the wood but it means very little after certain time.

Sound Source Tracking Control of a Mobile Robot Using a Microphone Array (마이크로폰 어레이를 이용한 이동 로봇의 음원 추적 제어)

  • Han, Jong-Ho;Han, Sun-Sin;Lee, Jang-Myung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.4
    • /
    • pp.343-352
    • /
    • 2012
  • To follow a sound source by a mobile robot, the relative position and orientation of the sound source from the mobile robot have been estimated using a microphone array. In this research, the difference among the traveling times of the sound source to each of three microphones has been used to calculate the distance and orientation of the sound source from the mobile robot which carries the microphone array. The cross-correlation between two signals has been applied for detecting the time difference between two signals, which provides reliable and precise value of the time difference comparing to the conventional methods. To generate the tracking direction to the sound source, fuzzy rules are applied and the results are used to control the mobile robot in a real-time. The efficiency of the proposed algorithm has been demonstrated through the real experiments comparing to the conventional approaches.