• 제목/요약/키워드: Tilting detector

검색결과 15건 처리시간 0.024초

견관절 Superoinferior axial 검사 시 Tiltable standing detector의 유용성에 관한 고찰 (Study of the Usefulness of Tiltable standing detector in Testing Shoulder Joint Superoinferior axial)

  • 이동희;김병기;김기정;김민현;이민우;김순배;김경수
    • 대한디지털의료영상학회논문지
    • /
    • 제11권1호
    • /
    • pp.27-33
    • /
    • 2009
  • In this study, we compared the alteration of test positions according to various test equipments when testing shoulder joint superoinferior axial to estimate the clinical usefulness of tiltable standing detector. Our objectives were patients who visited our hospital. Among them we chose patients who were prescribed to get a shoulder axial test, again we selected 30 patients whose abduction is more than 90 degree.(2008. Nov.$\sim$2009 Jan.) With the patients cooperation, we used CR(Agfa, Belgium), fixed-detector(Canon, japan), Tiltable-detector(Philips, Netherlands). Tested with only one equipment(tiltable detector), and posed with the other two. We surveyed 5 inspectors and 30 patients, asking them to rate the convenience of test position. Also, we checked how long it takes to have the image appear on screen after testing with the equipment We provided a standard for an assessment of the image to an expert in bone radiology, an orthopedist and a radiologist with 5 years experience. When the patients were asked about the convenience of the equipments, 15 people(50%) answered CR is convenient and 14 people(46.7%) answered the Tilting detector is convenient, showing not much difference. However, when the inspectors were asked the same question, 4people(80%) out of 5 answered that the Tilting detector is more convenient The time test showed that CR takes 2 minutes and 50 seconds, the Fixed detector 1minute and 48 seconds andor had no distortion showing the shoulder joint space. However, even though the Fixed detector showed ac the Tilting detector takes 1 minute and 43 seconds to bring the image to the screen after the position. The results of the value of image taken by each equipment, CR and the Tilting detectromion, coracoid process, due to the unstable pose, they were quite distorted and scored poor in observing glenoid fossa. By this study, we can see that testing the shoulder joint superoinferior axial projection with a detector that has a tilting device would be more convenient than testing it with a CR.

  • PDF

고해상도 영상 획득을 위한 틸트 메커니즘 적용 기법 (Applying tilt mechanism for high-resolution image acquisition)

  • 송천호
    • 한국컴퓨터정보학회논문지
    • /
    • 제19권12호
    • /
    • pp.31-37
    • /
    • 2014
  • 본 연구논문에서는 고해상도 적외선 센서장비에서 조립오차에 의해 저하된 성능을 보완하기 위해 적외선 센서장비의 구성품인 렌즈조립체, 축거울 및 검출기의 민감도 분석을 통해 성능에 미치는 영향성을 확인하였고, 이를 보정하기 위해 검출기의 틸트 메커니즘 적용 방안에 대한 연구를 하였다. 검출기 틸트 메커니즘에는 장착면에 shim을 적용하여 tilt하는 방식인 Shim plate 방식과 tilt screw를 조정하여 검출면의 tilt를 조정하는 Tilting 나사 방식, 마지막으로 마이크로미터를 장착하여 정량적인 데이터를 획득할 수 있는 마이크로미터 헤드 방식으로 3가지 방식이 검토 되었다. 검토 결과 사용자의 조절이 용이하고 부피가 크지 않으며 실시간으로 영상을 보면서 조절이 가능한 Tilting 나사 방식을 적용하였으며, 실험결과 고해상도 영상을 획득할 수 있었으며 고해상도 영상획득을 구현하기 위한 장비에 적용이 필요한 기술임을 확인하였다.

구조가 간단한 마이크로파 센서 개발 (Development of Simple Structure Microwave Sensor)

  • 정순원;이재진;구경완
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.270-274
    • /
    • 2008
  • The microwave sensor in which the sensitivity was excellent and a structure is simple was developed and it manufactured. And the sensing range that uses the developed product was confirmed. When the developed microwave sensor was set up in the ceiling of a building, we confirmed that the amplitude of the sensitive area increased as the tilting angle was enlarged. The sensitive area became a greatest in case the tilting angle was 65 degree. According to the height of a ceiling, because the sensing range is determined, in case of using in the building in which the height of a ceiling is enough secured it is determined to secure the more wide sensitive area. Moreover, the configuration of the circuit having the simple structure makes the miniaturization of a product, and the light weight possible. It is considered to have the price competitive power which it reduces the manufacturing cost, is sufficient.

검출기 중심축을 자동 보정하는 초소형 CT 개발 및 성능평가 (Development and Performance Evaluation of an Ultra-Compact CT with Auto Calibration of Detector Center Axis)

  • 곽병우;류근호
    • 한국방사선학회논문지
    • /
    • 제17권5호
    • /
    • pp.651-662
    • /
    • 2023
  • 본 연구에서는 검출기의 중심축을 자동 보정하는 초소형 CT를 설계 및 제작하고 성능을 검증하였다. 3D CAD 데이터와 초소형 CT 검출기 중심축을 수동으로 보정하여 촬영한 X-ray 데이터를 사용하여 3차원 재구성 성능을 평가하였다. 그 결과, 중심축이 0.25° 이상 기울면 원형 깨짐 현상이 발생하면서 3차원 재구성 영상의 품질이 급격히 저하된다는 사실을 발견하였다. 검출기 중심축 자동보정 장치를 적용하여 검출기 중심축이 시편 회전축과 일치하도록 보정하여 3차원 재구성 성능을 향상시켰다.

PSD를 이용한 MMAD의 동작특성 측정에 관한 연구 (Measurements of Dynamic Response of Micro-Mirror using Position Sensitive Detector)

  • 김종국;김호성;신형재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 G
    • /
    • pp.2527-2529
    • /
    • 1998
  • Measurement equipment, which consists of He-Ne laser, objective lens, CCD camera and position sensitive detector, was developed for the dynamic response of micromirror. This equipment can measure the tilting direction and angle, the rise time and frequency response of micromirror to the input signal. It was found that the rise time of the micromirror was less than 10${\mu}m$ and the resonant frequency was about 25kHz.

  • PDF

레이저를 이용한 박판 버의 정밀측정 (Precision measuring of burrs on sheet metal using the laser)

  • 신홍규;홍남표;김헌영;김병희
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1824-1827
    • /
    • 2003
  • The sheet metal shearing process is normally used in the precision elements such as semi-conductor components. In precision elements, burrs usually reduce the quality of machined parts and cause interference, jamming and misalignment during assembly procedures and because of their sharpness, they can be safety hazard to personnel. Furthermore, not only burrs are hard to predict and avoid, but also deburring, the process of removing burrs, is time-consuming and costly. In order to get the burr-free parts, therefore, we developed the precise burr measuring system using the laser. The laser burr measuring system consists of the laser probe, the photo detector, the achromatic doublet lens, and the rotary & the X-Y table. In previous reports, we used simple vertical measuring method. But, as we used relatively bigger laser spot diameter and had the limited reflection angle, it was difficult to obtain the precise measuring results. So called, the spot size effect makes the profile of burr measured distorted and the burr height measured smaller. By introducing the novel laser measuring method which employing the achromatic lens system and the tilting mechanism, we could make the spot size smaller and get the appropriate beam direction angle. Through the experiments, the accuracy of the developed system is proved. The burr height measured during the punching process can be used for automatic deburring and in-situ aligning.

  • PDF

표면이 마모된 틸팅 패드 저널베어링의 열윤활 해석 및 온도 측정 (Thermohydrodynamic Analysis and Pad Temperature Measurement of Tilting Pad Journal Bearing with Worn Pad)

  • 이동현;선경호;김병옥;강동혁
    • Tribology and Lubricants
    • /
    • 제33권4호
    • /
    • pp.134-140
    • /
    • 2017
  • With the increase in adoption of tilting pad journal bearings (TPJBs), various failure mechanisms related to TPJBs have been reported, of which pad wear is a frequently reported one. Pad wear causes change in geometry of the bearing, which can sometimes result in the failure of the entire system. The objective of this research is to investigate the influence of pad wear on the pad temperature, which is one of the widely used condition monitoring methods for TPJBs. For the theoretical investigation, thermohydrodynamic (THD) analysis was conducted by solving the generalized Reynolds equation and the 3D energy equation. The results of the analysis show that the temperature of the loaded pad increases while that of the unloaded pad decreases, when there is wear on the loaded pads. In addition, the minimum film thickness decreases with an increase in the wear depth. A validation test was conducted with a test rig, which mimics the axial turbine when a test rotor is supported by two TPJBs. The test bearing consists of five pads with a diameter of 60 mm, and a resistance temperature detector (RTD) is installed in the pad for temperature monitoring. The test was performed by replacing the two loaded pads with the worn pad. The test result for the TPJB with wear depth of $30{\mu}m$ show that the temperatures of the loaded pads are $8^{\circ}C$ higher and that of the unloaded pad is $2.5^{\circ}C$ lower than that of the normal TPJB. In addition, the predicted pad temperature shows good agreement with the measured pad temperatures.

IR 레이저 기반 연기감지기를 위한 고정밀 자동초점 정합장치에 관한 연구 (A Study on High-precision Autofocus Matching Device for Smoke Detector Based on IR Laser)

  • 김관형;신동석;오암석
    • 한국정보통신학회논문지
    • /
    • 제18권11호
    • /
    • pp.2759-2764
    • /
    • 2014
  • 화재감지 시간을 단축하기 위해서 연기감지기가 활용되는 추세이며, 발신기와 수신기가 100m이상 이격되어 설치되는 구조의 연기감지기는 외부환경의 영향으로 인한 발신기의 각도변화에 따라 수광부 레이저 포인트 위치가 매우 민감하게 변화한다. 본 논문에서는 레이저 발신기와 수신기 간의 원거리 설치에 따른 레이저 초점 설정의 어려움을 해결하고 외부 환경에 따른 초점 정합의 문제를 해결하기 위해서 다중 웜기어를 활용한 고정밀 제어장치와 레이저 광선의 틀어진 각도를 조정 할 수 있는 자동초점 정합 알고리즘을 제시한다.

반복적인 방법을 이용한 임의의 DR detector 위치에서의 flat field correction 방법 연구 (An Iterative Method for Flat-Field Correction of Digital Radiography When Detector is at Any Position)

  • 김도일;이형구;김성현;박대섭;최보영;서태석
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.64-66
    • /
    • 2004
  • 디지털 래디오그래피 시스템을 이용하여 환자를 진료하기 위해서는 전처리 과정을 통해 DR 디텍터의 불량화소와 선을 제거하고 offset과 X선의 불균질성을 제거해야만 한다. 불균질성을 제거하기 위해 X-선의 flat field 영상이 필요하며 이는 X선관의 focal spot과 디텍터의 중심과 일치시켜 X선을 디텍터에 수직으로 입사시켜 얻는다. 이러한 영상 촬영구조는 환자를 촬영할 때에도 그대로 유지된다. 하지만 방사선 촬영 기법 중 여러 가지 요인으로 디텍터의 중심과 X선관의 중심을 일치시키지 않거나 디텍터를 기울여 촬영하는 방법들이 있다. 본 연구에서는 디텍터가 기울어져 있거나 또는 임의의 위치에서의 flat field correction 방법의 영향을 분석하고, 새로운 알고리즘을 이용하여 그 영향을 줄이고자 하였다. 본 연구의 결과로 DR 디텍터에서 X선의 flat field를 최대한 보장할 수 있을 것이다.

  • PDF

팬터그래프-전차선로 접촉부 영상처리 기술 개발 (Development of Image Processing Technology for Interaction between Pantograph and Overhead Contact Wire)

  • 김형준;박영;조용현;조철진;김인철
    • 한국전기전자재료학회논문지
    • /
    • 제22권12호
    • /
    • pp.1084-1088
    • /
    • 2009
  • The measurement of dynamic stagger in electric railways is one of the key test parameters to increase speed and maintain safety in electric railways. This paper is introduces a non-contact optical-based measuring instrument of a catenary system in electric railways. The instrument is implemented by utilizing a CCD (Charge Coupled Device) camera installed on the roof of a vehicle for vision acquisition and image processing techniques including the Canny edge detector and the Hough transform to detect contact wires and calculate dynamic stagger. To check the validity of our approach for the intended application, we measured stagger of a overhead wire of a Korea Tilting Train (TTX). The non-contact optical-based measurement system proposed in this paper performs real-time stagger measurement of an activated high-voltage contact wire. By results of this paper, the instrument should be applied to assess performance and reliability of newly developed electric railway vehicles.