• Title/Summary/Keyword: Tilt measurements

Search Result 78, Processing Time 0.028 seconds

Evaluation of acromial spur using ultrasonography

  • Kim, Hyungsuk;Choi, Syungkyun;Park, Soo Bin;Song, Hyun Seok
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.1
    • /
    • pp.15-20
    • /
    • 2021
  • Background: The presence of an acromial spur implies a rotator cuff disorder due to impingement between the acromial spur and the rotator cuff. The purpose of the study was to observe acromial spurs using ultrasonography and to compare measurements between plain radiographs and sonograms. Methods: We retrospectively enrolled 51 consecutive patients with acromial spurs, which were interpreted on preoperative plain radiographs (supraspinatus outlet view and 30° caudal tilt) and preoperative sonograms. The ultrasonography transducer was held vertically and continuously moved laterally, which corresponded to the long axis of the long head of the biceps. The distance from the most distal margin of the original acromion to the most projected point of the acromial spur was measured. Results: No significant difference was found between the plain radiograph and ultrasonography measurements (p=0.186). A moderate to strong correlation was detected between the ultrasonography and supraspinatus outlet-view measurements (r=0.776, p=0.000). Conclusions: Anteriorly projected acromial spurs were well-visualized by ultrasonography. No discrepancy in acromial spur length was detected between the use of plain radiography (supraspinatus outlet view and 30° caudal-tilt view) and ultrasonography. The correlation coefficients between the plain radiography and ultrasonography measurements exceeded 0.7.

X-ray Scattering Studies for Phase Separated Composite Organic Films

  • Choi, H.;Eom, K.E.;Wang, Q.;Kumar, S.;Kim, J.H.;Shin, S.T.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1229-1232
    • /
    • 2004
  • The ratio of optimized concentration on optical characteristics for phase-separated composite organic films (PSCOF) liquid crystal display is 30% of pre-polymer (NOA65) and 70% of ferroelectric liquid crystal (Felix). The layer structure in ferroelectric liquid crystal cell made by 30% NOA65 and 70% Felix materials is tilt-bookshelf layer structure. The angle of tilt-bookshelf structure are 17$^{\circ}$, 12$^{\circ}$ which are almost same of tilt angle of ferroelectric liquid crystal in Sm $C^{\ast}$ phase. We know that this result is from compensating the layer buckling. In this paper, we will discuss the effect of layer structure in PSCOF cell on ratio of concentration between pre-polymer and liquid crystal by x-ray measurements. We believe that technology of PSCOF is a good solution to solve the problems of align-defect and mechanical shock for future TV application and plastic LCD.

  • PDF

Target strength estimation by tilt angle and size dependence of rockfish (Sebastes schlegeli) using ex-situ and acoustic scattering model (현수법과 모델을 이용한 조피볼락의 유영자세각과 체장에 따른 음향 후방산란강도)

  • YOON, Euna;KIM, Kiseon;LEE, Intae;JO, Hyeon-Jeong;LEE, Kyounghoon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.53 no.2
    • /
    • pp.152-159
    • /
    • 2017
  • Rockfish was a commercially important fish specie in marine ranching areas in Korea. To estimate density and biomass of rockfish using acoustic method, target strength (TS) information is required on the species. This study measured TS dependence on tilt angle and size on 14 live rockfish individuals at 38, 70, and, 120 kHz by ex-situ measurement (tethered method) and acoustic scattering model (Krichhoff ray mode, KRM). The swimbladdered angle ranged from 18 to $30^{\circ}$ ($mean{\pm}s.d.=26{\pm}4^{\circ}$). The mean TS for all individuals was highest -35.9 dB of tilt angle $-17^{\circ}$ at 38 kHz, -35.4 dB of tilt angle $-25^{\circ}$ at 70 kHz, and -34.9 dB of tilt angle $-22^{\circ}$ at 120 kHz. The ex-situ TS-total length (TL, cm) relationships were $TS_{38kHz}=20log_{10}(TL)-67.1$, $TS_{70kHz}=20log_{10}(TL)-68.6$, and $TS_{120kHz}=20log_{10}(TL)-69.9$, respectively. The model TS-total length (TL, cm) relationships were $TS_{38kHz}=20log_{10}(TL)-66.4$, $TS_{70kHz}=20log_{10}(TL)-67.0$, $TS_{120kHz}=20log_{10}(TL)-67.0$. The two measurements between the ex-situ TS and KRM model for TS-tilt angle and fish size were found to be significantly correlated.

Development of Tilt angle measurement system of plastic thin-film using Position Sensitive Device (PSD를 이용한 플라스틱 박막 필름의 경사 각도 측정 시스템 개발)

  • Kim, Gi-Seung;Park, Yoon-Chang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.134-138
    • /
    • 2021
  • Various types of precision plastic thin films are used widely in high-performance displays, such as smartphones. For plastic thin-films manufactured by the Roll-to-Roll process, the film thickness must be measured and managed while moving. In the Roll-to-Roll process, wrinkles are generated when tension is applied to the film, which causes an inclination on the optical axis of the thickness gauge, resulting in a loss of accuracy. Therefore, this study attempted to develop an optical interference tomography measurement system. In this study, the tilt angle of the film was measured to correct the measurement value error in the thickness gauge caused by the tilt of the film. The system was constructed so that the laser was irradiated on the tilted film, and the laser reflected from the film was formed on the PSD. The relationship between the tilt angle of the film and the output value of the PSD was obtained experimentally. Using this, a device to measure the tilt angle of the film was constructed, and angle measurements were taken at a speed of 250,000Hz.

Effects of Deep Cervical Flexors Strengthening Exercise on Cervical-Shoulder Angle, Disability index and pain and in Patients with Chronic Neck Pain (깊은목굽힘근 강화운동이 만성 목통증 환자의 통증과 목-어깨각도, 장애지수 및 통증에 미치는 영향)

  • Kim, Jin-young
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.21 no.2
    • /
    • pp.33-37
    • /
    • 2015
  • Background: The purpose of this study on the effects of deep cervical flexors strengthening exercise to forward head posture and pain of neck in patients with chronic neck pain. Method: We selected 30 subjects among neck pain patients and carried out measurements. The subjects' forward head posture was measured including head tilt angle (HTA), neck flexion angle (NFA) and forward shoulder angle (FSA), neck disability index (NDI), numeric rating scale (NRS). The subjects underwent deep cervical flexors muscle strengthening with pressure bio-feedback device for 4 weeks. Then, after intervention, the subjects' forward head posture was measured again. It was performed Wilcoxon signed-ranks test for confirming the effect of deep cervical flexor muscles strengthening exercise. Results: As a result of comparison of measurements before and after intervention, we found that there were statistically significant improvement in the subjects' NDI, NRS and forward head posture including head tilt angle, neck flexion angle and forward shoulder angle. Conclusion: We concluded that deep cervical flexors strengthening exercise has the effect of alleviation of neck pain patients and is effective for forward head posture.

  • PDF

Changes of Minute Blood Flow in the Large Vessels during Orthostasis and Antiorthostasis, before and after Atropine Administration (체위변화가 두부 및 하지의 분시혈류량에 미치는 영향)

  • Park, Won-Kyun;Chae, E-Up
    • The Korean Journal of Physiology
    • /
    • v.19 no.2
    • /
    • pp.139-153
    • /
    • 1985
  • The passive tilt has been performed to study the orthostasis on the cardiovascular system. The orthostasis due to upright tilt was demonstrated as follows: the venous return, cardiac output and systemic arteiral blood pressure were decreased, whereas there was concomitant increase of heart rate, through the negative feedback mediated by such as the baroreceptor . Previous investigators have suggested that the tolerance to the orthostasis could he increased by blocking the cholinergic fiber with atropine which prevented vasodilation and bradycardia through the vasovagal reflex during the orthostasis. However, this hypothesis has not been clearly understood. This study was attempted to clarify the effect of atropine on the tolerance of the cardiovascular system to the upright and head-down tilt, and to investigate the change of the blood flow through head and lower leg with Electromagnetic flowmeter in both tilts before and after atropine state. Fourteen anesthetized dogs of $10{\sim}14kg$ were examined by tilting from supine position to $+77^{\circ}$ upright position (orthostasis), and then to $-90^{\circ}$ head-down position (antiorthostasis) for 10 minutes on each test. And the same course was taken 20 minutes after intravenous administration of 0.5mg atropine. The measurements were made of the blood flow(ml/min.) on the carotid artery, external jugular vein, femoral artery and femoral vein. At the same time pH, $PCO_2$, $PO_2$ and hematocrit (Hct) of the arterial and venous blood, and heart rate(HR) and respiratory rate (RR) were measured. The measurements obtained from upright and head-down tilt were compared with those from supine position. The results obtained are as follows: In upright tilt, the blood flow both on the artery and the vein through head and lower leg were decreased, however the decrement of blood flow through the head was greater than the lower leg And the atropine attenuated the decrement of the blood flow on the carotid artery, but not on the vessels of the lower leg. HR was moderately increased in upright tilt, but slightly in head-down tilt. The percent change of HR after the atropine administration was smaller than that before the atropine state in both upright and head-down tilts. Before the atropine state, RR was decreased in upright tilt, whereas increased in head-down tilt. However after the atropine state, the percent change of RR was smaller than that of before the atropine state in both upright and head-down tilts. In upright tilt, venous $PCO_2$ was increased, but arterial $PO_2$ and venous $PO_2$ were slightly decreased. Hct was increased in both upright and head-down tilts. The findings of blood $PCO_2$, $PO_2$ and Hct were not interferred by the atropine. In conclusion, 1;he administration of atropine is somewhat effective on improving the cardiovascular tolerance to postural changes. Thus, atropine attenuates the severe diminution of the blood flow to the head during orthostasis, and also reduces the changes of HR and RR in both orthostasis and antiorthostasis.

  • PDF

Development of a Ground Speed Monitoring System for Aerial Application (항공방제용 지면속도 감시장치의 개발)

  • 구영모;알빈워맥
    • Journal of Biosystems Engineering
    • /
    • v.25 no.3
    • /
    • pp.233-240
    • /
    • 2000
  • A commercially available Doppler radar was modified and evaluated for on-board monitoring of ground speed. The radar output was corrected for pitch angle of aircraft based on the output of an electrolytic tilt sensor. The effects of aircraft speed, height and mounting angle on error in the ground speed were evaluated. The speed error decreased with an increase of the mounting angle since the radar contact angle with respect to the ground approached to the mounting angle. The error increased with an increase of the nominal aircraft speed. The altitude insignificantly affected the speed error. The Doppler radar provided acceptable percent errors within 5% in most measurements. The error can be reduced within ${\pm}$1.5% by increasing the mounting angle ($43^{\circ}$). The error of -3.8% at the mounting angle of $29^{\circ}$could be reduced by adjusting the mounting angle with respect to the radar contact angle.

  • PDF

Construction of a Data Bank for Acoustic Target Strength with Fish Species, Length and Acoustic Frequency for Measuring Fish Size Distribution (어류 체장의 자동 식별을 위한 어종별, 체장별 및 주파수별 음향 반사 강도의 데이터 뱅크 구축)

  • LEE Dae-Jae;SHIN Hyeong-Il
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.38 no.4
    • /
    • pp.265-275
    • /
    • 2005
  • A prerequisite for deriving the abundance estimates from acoustic surveys for commercially important fish species is the identification of target strength measurements for selected fish species. In relation to these needs, the goal of this study was to construct a data bank for converting the acoustic measurements of target strength to biological estimates of fish length and to simultaneously obtain the target strength-fish length relationship. Laboratory measurements of target strength on 15 commercially important fish species were carried out at five frequencies of 50, 70, 75, 120 and 200 kHz by single and split beam methods under the controlled conditions of the fresh and the sea water tanks with the 389 samples of dead and live fishes. The target strength pattern on individual fish of each species was measured as a function of tilt angle, ranging from $-45^{\circ}$ (head down aspect) to $+45^{\circ}$ (head up aspect) in $0.2^{\circ}$ intervals, and the averaged target strength was estimated by assuming the tilt angle distribution as N $(-5.0^{\circ},\;15.0^{\circ})$. The TS to fish length relationship for each species was independently derived by a least-squares fitting procedure. Also, a linear regression analysis for all species was performed to reduce the data to a set of empirical equations showing the variation of target strength to a fish length, wavelength and fish species. For four of the frequencies (50, 75, 120 and 200 kHz), an empirical model for fish target strength (TS, dB) averaged over the dorsal sapect of 602 fishes of 10 species and which spans the fish length (L, m) to wavelength (\Lambda,\;m)$ ratio between 5 and 73 was derived: $TS=19.44\;Log(L)+0.56\;Log(\Lambda)-30.9,\;(r^2=0.53)$.

Reliability and validity of pelvic mobility measurement using a cushion sensor in healthy adults

  • Jung, Seung-Hwa;Kim, Su-Kyeong;Lee, Ji-Hyun;Choi, Soo-Ih;Park, Dae-Sung
    • Physical Therapy Rehabilitation Science
    • /
    • v.9 no.2
    • /
    • pp.74-81
    • /
    • 2020
  • Objective: To prevent low back pain, an objective evaluation tool to evaluate pelvic mobility and exercise to improve the flexibility of the lumbar region is needed. The purpose of this study was to compare the results of pelvic mobility measurements using the Wii Balance Board (WBB) and Sensbalance Therapy Cushion (STC), evaluate the usefulness of the STC as a tool for measuring pelvic mobility. Design: Cross-sectional study. Methods: Fifty healthy subjects participated in this study. The subjects performed pelvic mobility range, proprioception, reaction time and reach of the arm using the STC. The pelvic movement parameter was measured two times to determine the intra-rater reliability. To measure the correlation between lumbar muscle tension and pelvic mobility, Myovision was used to measure tension of L4, L5 level erector spinae muscle. Correlations between measured variables were checked to determine the validity of the pelvic mobility assessment tool. Results: STC showed high test-retest reliability in pelvic tilt measurement and reaching task [intraclass correlation coefficients (3,1)=0.804-0.915]. The relationship between WBB and STC showed a significant positive correlation with the pelvic tilt and reaching task (p<0.05). Posterior tilt and erector spinae activation (Lt. L5) showed a significant negative correlation (p<0.05). Left, right tilt and erector spinae activation (L5) showed a significant negative correlation (p<0.05). Conclusions: This study confirmed the advantages of the STC and found efficiency as an objective measuring device of pelvic mobility.

Development of Topological Correction Algorithms for ADCP Multibeam Bathymetry Measurements (ADCP 다중빔 수심계측자료의 위상학적 보정 알고리즘 개발)

  • Kim, Dong-Su;Yang, Sung-Kee;Kim, Soo-Jeong;Jung, Woo-Yul
    • Journal of Environmental Science International
    • /
    • v.22 no.5
    • /
    • pp.543-554
    • /
    • 2013
  • Acoustic Doppler Current Profilers (ADCPs) are increasingly popular in the river research and management communities being primarily used for estimation of stream flows. ADCPs capabilities, however, entail additional features that are not fully explored, such as morphological representation of river or reservoir bed based upon multi-beam depth measurements. In addition to flow velocity, ADCP measurements include river bathymetry information through the depth measurements acquired in individual 4 or 5 beams with a given oblique angle. Such sounding capability indicates that multi-beam ADCPs can be utilized as an efficient depth-sounder to be more capable than the conventional single-beam eco-sounders. The paper introduces the post-processing algorithms required to deal with raw ADCP bathymetry measurements including the following aspects: a) correcting the individual beam depths for tilt (pitch and roll); b) filtering outliers using SMART filters; d) transforming the corrected depths into geographical coordinates by UTM conversion; and, e) tag the beam detecting locations with the concurrent GPS information; f) spatial representation in a GIS package. The developed algorithms are applied for the ADCP bathymetric dataset acquired from Han-Cheon in Jeju Island to validate themselves applicability.