• Title/Summary/Keyword: Tightness

Search Result 438, Processing Time 0.028 seconds

2019 Novel Coronavirus (COVID-19) Pneumonia: Serial Computed Tomography Findings

  • Jiangping Wei;Huaxiang Xu;Jingliang Xiong;Qinglin Shen;Bing Fan;Chenglong Ye;Wentao Dong;Fangfang Hu
    • Korean Journal of Radiology
    • /
    • v.21 no.4
    • /
    • pp.501-504
    • /
    • 2020
  • From December 2019, Coronavirus disease 2019 (COVID-19) pneumonia (formerly known as the 2019 novel Coronavirus [2019-nCoV]) broke out in Wuhan, China. In this study, we present serial CT findings in a 40-year-old female patient with COVID-19 pneumonia who presented with the symptoms of fever, chest tightness, and fatigue. She was diagnosed with COVID-19 infection confirmed by real-time reverse-transcriptase-polymerase chain reaction. CT showed rapidly progressing peripheral consolidations and ground-glass opacities in both lungs. After treatment, the lesions were shown to be almost absorbed leaving the fibrous lesions.

Effect of Cyclic Wetting-drying on Self-healing of Cementitious Materials Containing Superabsorbent Polymers (습윤/건조 반복 작용이 고흡수율 폴리머를 함유한 시멘트계 재료의 자기치유에 미치는 영향)

  • Hong, Geuntae;Choi, Seongcheol
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.1
    • /
    • pp.88-96
    • /
    • 2020
  • In this study, the effect of cyclic wetting-drying on the self-healing of cementitious materials containing superabsorbent polymers (SAPs) were experimentally evaluated. In each cycle, cracked cement paste specimens containing various SAP dosages were exposed to wet conditions for 1 h, during which the capillary water absorption tests and water flow tests were conducted, and then exposed to dry conditions for 47 h. The capillary water absorption test results showed that the sorptivity values of the specimen without SAPs, SAP 0.5%, SAP 1.0%, and SAP 1.5% specimens were decreased by approximately 22.9%, 36.8%, 42.8%, and 46.3%, respectively, after 8 cycles. In addition, the water flow test results showed that the amount of water runoff through the cracks of all cracked specimens gradually decreased over wet/dry cycles, especially the reduction ratio of the amount of water runoff increased with increasing SAP dosage. Furthermore, the swelling behavior of SAPs in cracks by in gress water was con firmed via X-ray computed tomography (CT) analysis. These results indicate that the effective crack width can be reduced as SAPs absorb water and swell, while the water absorbed in SAPs can be released to crack surfaces under dry conditions, further promoting healing product formation. This study demon strates that the in corporation of SAPs can in crease the water tightness of cracks, thereby improving the self-healing efficiency of cementitious materials.

Hydrogeological Stability Study on the Underground Oil Storage Caverns by Numerical Modeling (수치모델링을 이용한 지하원유비축시설의 수리지질학적 안정성 연구)

  • 김경수;정지곤
    • The Journal of Engineering Geology
    • /
    • v.12 no.1
    • /
    • pp.35-51
    • /
    • 2002
  • This study aims to establish the methodology for design of an optimum water curtain system of the unlined underground oil storage cavern satisfying the requirements of hydrodynamic performance in a volcanic terrain of the south coastal area. For the optimum water curtain system in the storage facility, the general characteristics of groundwater flow system in the site are quantitatively described, i.e. distribution of hydraulic gradients, groundwater inflow rate into the storage caverns, and hydrogeologic influence area of the cavern. In this study, numerical models such as MODFLOW, FracMan/MAFIC and CONNECTFLOW are used for calculating the hydrogeological stability parameters. The design of a horizontal water curtain system requires considering the distance between water curtain and storage cavern, spacing of the water curtain boreholes, and injection pressure. From the numerical simulations at different scales, the optimum water curtain systems satisfying the containment criteria are obtained. The inflow rates into storage caverns estimated by a continuum model ranged from about 120 m$^3$/day during the operation stage to 130~140m$^3$/day during the construction stage, whereas the inflow rates by a fracture network model are 80~175m$^3$/day. The excavation works in the site will generate the excessive decline of groundwater level in a main fracture zone adjacent to the cavern. Therefore, the vertical water curtain system is necessary for sustaining the safe groundwater level in the fracture zone.

Comparison of Two Methods for Determining Initial Radius in the Sphere Decoder (스피어 디코더에서 초기 반지름을 결정하는 두 가지 방법에 대한 비교 연구)

  • Jeon, Eun-Sung;Kim, Yo-Han;Kim, Dong-Ku
    • Journal of Advanced Navigation Technology
    • /
    • v.10 no.4
    • /
    • pp.371-376
    • /
    • 2006
  • The initial radius of sphere decoder has great effect on the bit error rate performance and computational complexity. Until now, it has been determined either by considering the statistical property of channel or by using of MMSE solution. The initial radius obtained by using statistical property of channel includes the lattice point corresponding to the transmit signal vector with very high probability. The method using MMSE solution first calculates out the MMSE solution of the received signal, then maps the hard decision of this solution into the received signal space, and finally the distance between the mapped point and the received signal is selected as the initial radius of the sphere decoding. In this paper, we derive a simple equation for initial radius selection which uses statistical property of channel and compare it with the method using MMSE solution. To compare two methods we define new metric 'Tightness'. Through the simulation, we observe that in low and moderate SNR region, the method using MMSE solution provides more complexity reduction for decoding while in high SNR region, the method using channel statistics is better.

  • PDF

Fast Selection of Composite Web Services Based on Workflow Partition (워크플로우 분할에 기반한 복합 웹 서비스의 빠른 선택)

  • Jang, Jae-Ho;Shin, Dong-Hoon;Lee, Kyong-Ho
    • Journal of KIISE:Software and Applications
    • /
    • v.34 no.5
    • /
    • pp.431-446
    • /
    • 2007
  • Executable composite Web services are selected by binding a given abstract workflow with the specific Web services that satisfy given QoS requirements. Considering the rapidly increasing number of Web services and their highly dynamic QoS environment, the fast selection of composite services is important. This paper presents a method for quality driven comosite Web services selection based on a workflow partition strategy. The proposed method partitions an abstract workflow into two sub-workflows to decrease the number of candidate services that should be considered. The QoS requirement is also decomposed for each partitioned workflow. Since the decomposition of a QoS requirement is based on heuristics, the selection might fail to find composite Web services. To avoid such a failure, the tightness of a QoS requirement is defined and a workflow is determined to be partitioned according to the tightness. A mixed integer linear programming is utilized for the efficient service selection. Experimental results show that the success rate of partitioning is above 99%. Particularly, the proposed method performs faster and selects composite services whose qualities are not significantly different (less than 5%) from the optimal one.

The Conditions for Wearing and Purchasing Brassieres by Korean Women - Based on the Female College Students in their Early 20's - (한국 성인여성의 브래지어 착용 및 구매실태 조사연구 - 20대 전반 여대생을 중심으로 -)

  • Cha, Su-Joung;Sohn, Hee-Soon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.34 no.2
    • /
    • pp.303-317
    • /
    • 2010
  • This study helps in the production of brassieres suitable for female adults by researching the actual wearing conditions and purchasing status, satisfaction rate, and preferences of female college students in their early 20's. The collected data was analyzed by a SPSSWIN 13.0 Program and the results of the research are as follows. 1. There is a noticeable difference between the breast satisfaction rate and breast size, in addition the satisfactory rate was higher in the normal breast size or a little ample size than in the very small or very big size. According to the shape, the satisfactory rate for the breast appeared to be high in the case of the recognition and evaluation of the hemisphere type than the flat, cone, pop out, and downward type. 2. For fitness, the looseness at the top of the cup (pressed between the breasts at the upper part of the front middle), pressing and looseness at the upper sides of the cup, inappropriate size of the cup, tightness of the wings, tightness at the bottom round of the breasts, the narrow width of the wire, wide space of the shoulder strings, and the sliding of the shoulder strings had problems that needed improvement. 3. The major priorities for purchasing brassieres are size, fitness, and aesthetic qualities. As a result, the size and the fitness are more important than the trend or decorations since the brassiere has the function to support the breasts that shows that hygiene and sanitation are recognized as an important standard for undergarment selection. The size and the fitness are important factors regardless of breast types in the examination of the selection standards of the brassieres for each breast type, but the cone and hemisphere types have higher preferences for design; the pop out type has more considerations for the material of the cloth. The result show that appearance is more important for smaller breasts, but the functionality of the brassier is more important than the appearance for medium and larger breast sizes.

Clinical Symptoms and Personality Characteristics on MMPI of Patients in Hwa-Byung Clinic (홧병클리닉을 방문한 환자들의 임상 증상과 MMPI 상의 성격 특징에 대한 연구)

  • Lee, Yu-Jin;Baek, Kyung-Won;Kim, Ha-Kyung;Yun, Kyu-Wol;Lim, Weon-Jeong
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.16 no.2
    • /
    • pp.120-124
    • /
    • 2008
  • Objectives : The current study aimed at assessing clinical symptoms and personality characteristics on MMPI of patients in Hwa-Byung clinic. Methods : Thirty-one female patients($45.4{\pm}8.4$ years old) who visited to the Hwa-Byung Clinic in Ewha womans Dongdaemoon hospital were recruited. Semistructured interviews and laboratory tests for symptoms were performed for the patients group. Patients group and control group($42.9{\pm}8.0$ years old) completed MMPI. Results : All patients had symptoms of chest tightness or chest pain. 19(61.3%) out of 31 patients had gastrointestinal complaints. There were respiratory symptoms in 13(41.9%) patients. 12 patients(38.7%) suffered from difficulties in their sleep. 12 patients(38.7%) had psychiatric symptoms including anxiety or depressed mood. 8 patients(27.6%) were diagnosed as gastrointestinal diseases by the laboratory test. After controlling age and education, scores of Hs, D, Hy, Pt on MMPI in patients group were significantly higher than control group (p=0.001, p=0.049, p=0.000, and p=0.029, ANCOVA, respectively). Conclusion : In the current study, patients who have visited Hwa-Byung clinic showed various somatic symptoms including chest tightness, gastrointestinal symptoms, complaints in respiratory system and psychiatric symptoms. Based on laboratory tests, considerable proportion of patients was diagnosed as physical illnesses. Additionally, patients in Hwa-Byung clinic have a tendency to be more hypochondriatic, depressed, hysteric and anxious.

  • PDF

Evaluation of Tightness of Proximal tooth Contact on Implant Prostheses (임프란트 보철수복물에서의 인접치간 접촉강도의 평가)

  • Kim, Sang-Pil;Jung, J-Hyun;Kang, Dong-Wan;Oh, Sang-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.371-379
    • /
    • 2008
  • The aim of this study was to evaluate the tightness of proximal tooth contact(TPTC) using a novel device at rest state on implant prostheses. Ten healthy young adults with class I normal occlusion consented to participate in the study and twenty patients were restored with a total 20 single-implant crowns in the left maxillary and mandibular second molars for 10 single-implant crowns, respectively. Test area were divided by 4 groups. UM describes the contact between the upper natural left first molar and natural second molar; LM the contact between the lower natural left first molar and natural second molar; IUM the contact between the upper natural left first molar and implant second molar and ILM the contact between the lower natural left first molar and implant second molar. The TPTC was measured at rest state in each area. The mean TPTC of the UM, LM, IUM and ILM was 1.48(${\pm}0.44$) N, 1.78(${\pm}0.40$) N, 1.14(${\pm}0.37$) N and 1.30(${\pm}0.32$) N respectively. These results indicate that the TPTC was less between natural tooth and implant prosthesis than between natural teeth.

FEA(Finite Element Analysis) Study for Electronic Hydrogen Regulator of Confidentiality Improvement (전자식 수소레귤레이터 기밀성 향상을 위한 FEA 연구)

  • Son, Won-Sik;Song, Jae-Wook;Jeon, Wan-Jae;Kim, Seung-Mo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.175-181
    • /
    • 2019
  • In the case of a conventional single stage decompression regulator used for large depressurization in the hydrogen fuel cell system of a fuel cell electric vehicle (FCEV), problems can arise, such as pulsation, slow response, hydrogen brittleness, leakage, high weight, and high cost due to high decompression. Most of these problems can be overcome easily using two decompression mechanisms (two-stage structures). In addition, a wide outlet-pressure control range can be secured if an electronic solenoid is applied to the second decompression. Accordingly, it is necessary to improve the precision of the outlet pressure of a two-stage pressure-reducing regulator and develop techniques, such as leakage prevention, durability, light weight, and price reduction. Therefore, to improve the outlet pressure accuracy and prevent leakage, the structural part before and after decompression to improve the air tightness were divided and the analysis was carried out assuming that the valve part was closed (open ratio: 0%) after each initial internal pressure application.

Analysis and Investigation of International(UIC, EN, IEC) and Domestic Standards(Test Methods) for Climatic Wind Tunnel Test of Rolling Stock (철도차량 기후환경시험을 위한 국제 규격(UIC, EN, IEC) 및 국내 규격(시험방법) 분석 및 고찰)

  • Jang, Yong-Jun;Chung, Jong-Duk;Lee, Jae-Cheon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.782-789
    • /
    • 2020
  • The demand for the development of rolling stock technology to maintain the best performance in various climatic environments has increased to expand the overseas market of rolling stock. In this study, international and domestic standards that must be applied to build a harsh climatic environment test system were investigated and compared. The way of improvement for domestic standards is proposed. The wind velocities and temperatures are specified in the UIC, EN, and IEC standards for climatic wind tunnel, and EN 50125-1 provides the velocity test up to 180km/h, the largest wind speed. UIC and EN provide the lowest temperature of -45℃, and IEC 62498-1 provides the highest temperature 55℃. The solar radiation test was specified up to 1200W/m2 in the UIC, EN, and IEC. The IEC, EN, and KS R 9145 provide the water tightness standards, which are different from each other in water capacity, pressure, and methods. The snow test method was not well specified. KRTS-VE-Part 31 provides pressurization test methods. The airtightness standards for high-speed rolling stock are defined and regulated for internal pressure change rate in UIC 660 and 779-11. The domestic standard for the wind tunnel test was not well prepared, and the solar radiation test and snow test do not exist in Korea. Therefore, it is necessary to improve domestic standards to an international level for the climatic wind tunnel test of rolling stock.