• Title/Summary/Keyword: Tight contact

Search Result 61, Processing Time 0.023 seconds

Hollow Beam Atom Tunnel (속 빈 레이저 빔을 이용한 원자 가이드)

  • 송연호
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.130-131
    • /
    • 2000
  • One of the more promising proposals for guiding and focusing neutral atoms involves dark hollow laser beams. When the frequency of the laser is detuned to the blue of resonance, the dipole force the atoms feel in the light confines them to the dark core where the atoms can be transported with minimal interaction with the light. The ability of the all-light atom guides to transport large number of ultracold atoms for long distances without physical walls leads to the possibility of a versatile tool for atom lithography, atom interferometry, atomic spectroscopy as well as for transporting and manipulating Bose-Einstein condensates. Furthermore since the atoms transported in all-light atom guides do not come into contact with matter, they can in principle be used to transport antimatter as well. The ability to vary the core size of the hollow beam makes the all-light atom guide potentially useful for focusing neutral atoms. The atoms could be focused as tight as the core size of the hollow beam at its waist. This new focusing scheme, called the atom funnel, would not show spherical and chromatic aberrations that conventional harmonic focusing suffers from. (omitted)

  • PDF

Substrate bonding technique using the agar-epoxy composites for flexible LCD

  • Bae, Ji-Hong;Jang, Se-Jin;Choi, Hong;Kim, Sang-Il;Kim, Jae-Hoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.733-736
    • /
    • 2007
  • We have proposed novel bonding technique of substrates for developing the flexible LCD with high quality. The gel type mixture of agarose and UV curable epoxy developed to obtain tight bonding ability and enhanced electro-optical characteristic simultaneously. This technique can be used to roll-to-roll process for fabricating the flexible LCDs.

  • PDF

Factors affecting transfer frequency of pAM$\beta$$_1$from streptococcus faecalis to lactobacillus casei (Streptococcus faecalis의 pAM $\beta$$_1$을 lactobacillus casei로의 전이에 영향을 미치는 요인)

  • 허정원;강성훈
    • Korean Journal of Microbiology
    • /
    • v.28 no.3
    • /
    • pp.188-191
    • /
    • 1990
  • The streptococcal plasmid pAM$\beta_{1}$ (erythromycin resistance)was transferred via conjugation from Streptococcus faecalis DS 5 to Lactobacillus casei YIT 9018 by a filter mating method. The transfer frequency depended greatly on the type, pore size and side(front or back) of membrane filter. Water passing through a membrane under reduced pressure induced very tight contact between the cells, increased the transconjugation frequency about 1.3 to 37-fold when Millipore membrane filter (0.45.$\mu$m, front side up) was used.

  • PDF

The threat of Monkeypox in the Philippines: another problematic preparation and management for the healthcare system?

  • Dalmacito A. Cordero Jr.
    • Clinical and Experimental Vaccine Research
    • /
    • v.12 no.1
    • /
    • pp.77-79
    • /
    • 2023
  • The Philippines is still in a tight battle with the coronavirus disease 2019 pandemic since many cases are detected daily. With the continuous spread of another disease worldwide-monkeypox, many Filipinos are alarmed if the country's healthcare system is prepared enough, especially with the detection of its first case. Learning from the unfortunate experiences of the country during the current pandemic is essential in facing another health crisis. With this, recommendations for a robust healthcare system are proposed centered on: a massive digital information campaign about the disease; training healthcare workers to raise awareness about the virus and its transmission, management, and treatment; an intensified surveillance and detection procedure to monitor cases and execute contact tracing properly; and a persistent procurement of vaccines and drugs for treatment, with a well-designed vaccination program.

Intrusion phenomenon of natural tooth bounded by implant-prostheses: a clinical report (임플란트 사이에 있는 자연치 함입 증례)

  • Kim, Joong-Hyun;Yang, Sun-Bong;Jo, Young-Sung;Park, Young-Bum
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.324-330
    • /
    • 2014
  • In case of implant-tooth connected prosthesis, a natural tooth tends to intrude. There are several mechanisms that explain an intrusion phenomenon. So it is reco mmended not to connect an implant with a natural tooth. A 68-year-old female had upper left $2^{nd}$ premolar and $2^{nd}$ molar extracted and underwent implant surgery on the missing area. We made an implant prosthesis and treated upper left $1^{st}$ molar with a gold crown. 2.5 year later, the patient complained about loose proximal contact and food impaction between upper left $1^{st}$ molar and $2^{nd}$ molar. Mesial side of upper left $2^{nd}$ molar implant prosthesis was soldered so that proximal contact became tight again. But after 7 months, about 2 mm intrusion of upper left $1^{st}$ molar occurred, and the patient felt periodontally originated pain on intruded upper left $1^{st}$ molar. After the gold crown on upper left $1^{st}$ molar was removed, extrusion occurred and pain was relived.

A STUDY ON THE STABILITY OF IMPLANT SCREW BY USE OF THE SEALER (Sealer의 사용이 임프란트 나사의 안정성에 미치는 영향)

  • Lee Heung-Tae;Kim Nak-Hyung;Chung Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.4
    • /
    • pp.366-375
    • /
    • 2001
  • The objective of this study was to investigate the surface contact and screw joint stability between screw and implant interface by use of sealer. The implants evaluated in this study were Steri-Oss futures(Hexlock $3.8D{\times}10mm$: Steri-Oss, Yorba Linda, CA), and Steri-Oss staight abutment. Titanium alloy screws were used to secure abutments to implants. The other titanium alloy screws applicating sealer(Impla-Seal, Implant Support Systems, Inc. Irvine, CA) were used to secure abutments to implants. In one another sample, 6kg of force was applied during simulated intraoral movements after abutment screws were secured to the implants with sealer. All samples were cross sectioned with sandpaper and polished with $0.1{\mu}m\;Al_2O_3$. Then samples were recorded with an scanning electron microscope. The results were as follows : 1. In the case of titanium alloy screw, irregular contacts and relatively large gap were present at thread mating surface. Also abutment screw/implant interface demonstrate incomplete seating and only one surface contact of threads between implant and screw. 2. In the case of titanium alloy screw applecating sealer, sealer was present between implant and screw. Therefore implant and screw had relatively close and tight contact without the presence of large gap. 3. On the other hand, in the case of titanium alloy screw applicating sealer and dynamic loading of suprastructures, sealer was partially present between implant and screw. Conclusively, sealer fills voids, creating a barrier to moisture and bacteria. In addition, loading of suprastructures may change the situation and limit the indications for gap sealing.

  • PDF

Studies on the Stabilities of Insectcides Combined with some Stabilizers (살충제제(殺蟲製劑)의 안정성(安定性)에 관(關)한 연구(硏究))

  • Woo, Chong-Hak;Kim, Jae-Wan
    • Journal of Pharmaceutical Investigation
    • /
    • v.1 no.1
    • /
    • pp.101-108
    • /
    • 1971
  • The stability and toxicity test for p.p'-DDT, DDVP and dipterex that put to used sample in this study effects is follows A. about p.p'-DDT (1) In elevating the stability of p.p'-DDT, best stabilizing solvent was benzene. (2) The stability-agent has no difficulty as long as it not contain metal ion for instance $Z_n^{2+}$,$C_r^{3+}$,$Al^{3+}$,and $Fe^{2+or3+}$ but in case of contain $F_e^{3+}$, the combination of salicylaminoguanidine is best effective. (3) Using this product for water-suspension, We must use span 40 for stability agent and adding it at the same time. (4) We must use container which does not week alkali and metal ion but it is to preserved in tight light-resistant container. (5) The stopper of container is adapted with above-mentioned condition of container, but it is better not to use metal material. (6) This product needs opening ventilation more than 30 minutes after diffusion or spray and in the room we remove cause of remained poison by cleaning the bottom. B. about DDVP and Dipterex (1) Benzene or toluene in best solvent to preserve stability of DDVP and Dipterex. (2) Span 40 is superior for stability agent of this product and second is span 80. (3) The pH of solution is very stable in pH 5-6 and comparative stable in alkali more than p,p'-DDT. (4) Container is to preserved in tight, lightresistant container and especially be careful of outflow and inflow of water. (5) Because this product is centeral stimulant poison, we must pay attention to prevent cause of contact diadermic toxicity after use.

  • PDF

A STUDY ON MASTICATORY PERFORMANCE AND MUSCLE ACTIVITY IN REMOVABLE PARTIAL DENTURE WEARERS (자연치열자와 가철성 국소의치 장착자의 저작효율과 근활성도에 관한 비교 연구)

  • Paik, Jin;Park, Nam-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.1
    • /
    • pp.81-103
    • /
    • 1998
  • The purpose of this study was to compare and evaluate the differences in masticatory performance, muscle activity, and patterns of occlusal contact between persons with natural dentition and removable partial denture wearers. Twenty healthy adult subjects with more than 28 teeth and thirteen removable partial denture wearers that classified Kennedy classification I was selected. The degree of pulverized rice and peanut was measured and analyzed by means of sieving method to compare the masticatory performance. For the muscle activity, EMG was recorded in selected muscles(Temporalis and masseter muscle) during mastication and resting state. The occlusal record in maximal intercuspation was taken with a silicone occlusal bite registration material for analysis of the patterns of occlusal contact. The obtained results were as follows: 1. When chewed peanuts, masticatory performance ratio at 10-sieve size was 81.31% in natural dentition group. In removable partial denture wearer, 27.01% without RPD and 69.09% with RPD. When chewed rice, 42.04%, 11.87%, and 21.58%, respectively. The differences of masticatory performance ratio between groups were statistically significant at the 0.05 level. 2. The mean EMG value in resting state was $1.06{\mu}V$ on temporal muscle, $0.98{\mu}V$ on masseter muscle in natural dentition group. In removable partial denture wearers, $1.13{\mu}V$ on temporal muscle, $1.05{\mu}V$ on masseter muscle without RPD and $1.11{\mu}V$ on temporal muscle, $1.04{\mu}V$ on masseter muscle with RPD. 3. The mean EMG value during mastication was $45.64{\mu}V$ in natural dentition group, and in removable partial denture wearers, $22.06{\mu}V$ without RPD and $31.01{\mu}V$ with RPD when chewed peanuts. When chewed rice, $45.24{\mu}V,\;25.53{\mu}V\;and\;32.14{\mu}V$, respectively. The differences of mean masticatory EMG value between groups were statistically significant at the 0.05 level. 4. The number of posterior occlusal contact point was 20.15 in natural dentition group and 11.92 in removable partial denture wearers. The area of perforated surface was $16.50mm^2$ in natural dentition group and $6.06mm^2$ in removable partial denture wearers. The area of contact surface was $78.93mm^2,\;51.52mm^2$, respectively. 5. The area of contact surface was effective to masticatory performance ratio in natural dentition group and removable partial denture wearers (p<0.05). From these results, it is concluded that in partially edentulous patient, masticatory efficiency can be improved by removable partial denture wearing, and for efficient mastication, tight occlusal contact surface shoud be maintained by maximum support that is provided from mucosa.

  • PDF

Growth of Endothelial Cells on Microfabricated Silicon Nitride Membranes for an In Vitro Model of the Blood-brain Barrier

  • Harris, Sarina G.;Shuler, Michael L.
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.8 no.4
    • /
    • pp.246-251
    • /
    • 2003
  • The blood-brain barrier (BBB) is composed of the brain capillaries, which are lined by endothelial cells displaying extremely tight intercellular junctions. Several attempts at creating an in vitro model of the BBB have been met with moderate success as brain capillary endothelial cells lose their barrier properties when isolated in cell culture. This may be due to a lack of recreation of the in vivo endothelial cellular environment in these models, including nearly constant contact with astrocyte foot processes. This work is motivated by the hypothesis that growing endothelial cells on one side of an ultra-thin, highly porous membrane and differentiating astrocyte or astrogliomal cells on the opposite side will lead to a higher degree of interaction between the two cell types and therefore to an improved model. Here we describe our initial efforts towards testing this hypothesis including a procedure for membrane fabrication and methods for culturing endothelial cells on these membranes. We have fabricated a 1 $\mu\textrm{m}$ thick, 2.0 $\mu\textrm{m}$ pore size, and 55% porous membrane with a very narrow pore size distribution from low-stress silicon nitride (SiN) utilizing techniques from the microelectronics industry. We have developed a base, acid, autoclave routine that prepares the membranes for cell culture both by cleaning residual fabrication chemicals from the surface and by increasing the hydrophilicity of the membranes (confirmed by contact angle measurements). Gelatin, fibronectin, and a 50/50 mixture of the two proteins were evaluated as potential basement membrane protein treatments prior to membrane cell seeding. All three treatments support adequate attachment and growth on the membranes compared to the control.

Dishevelling Wnt and Hippo

  • Kim, Nam Hee;Lee, Yoonmi;Yook, Jong In
    • BMB Reports
    • /
    • v.51 no.9
    • /
    • pp.425-426
    • /
    • 2018
  • As highly conserved signaling cascades of multicellular organisms, Wnt and Hippo pathways control a wide range of cellular activities, including cell adhesion, fate determination, cell cycle, motility, polarity, and metabolism. Dysregulation of those pathways are implicated in many human diseases, including cancer. Similarly to ${\beta}-catenin$ in the Wnt pathway, the YAP transcription co-activator is a major player in Hippo. Although the intracellular dynamics of YAP are well-known to largely depend on phosphorylation by LATS and AMPK kinases, the molecular effector of YAP cytosolic translocation remains unidentified. Recently, we reported that the Dishevelled (DVL), a key scaffolding protein between canonical and non-canonical Wnt pathway, is responsible for nuclear export of phosphorylated YAP. The DVL is also required for YAP intracellular trafficking induced by E-cadherin, ${\alpha}-catenin$, or metabolic stress. Note that the p53/LATS2 and LKB1/AMPK tumor suppressor axes, commonly inactivated in human cancer, govern the reciprocal inhibition between DVL and YAP. Conversely, loss of the tumor suppressor allows co-activation of YAP and Wnt independent of epithelial polarity or contact inhibition in human cancer. These observations provide novel mechanistic insight into (1) a tight molecular connection merging the Wnt and Hippo pathways, and (2) the importance of tumor suppressor contexts with respect to controlled proliferation and epithelial polarity regulated by cell adhesion.