• 제목/요약/키워드: Thyristor dual converter system

검색결과 8건 처리시간 0.019초

도시 철도용 사이리스터 듀얼 컨버터 시스템의 3병렬 운전 제어 기법에 관한 연구 (A Study on Three Parallel Operation Control Algorithm of Thyristor Dual Converter System for Urban Railway Substation)

  • 김성안;한성우;조윤현
    • 전기학회논문지
    • /
    • 제66권2호
    • /
    • pp.459-467
    • /
    • 2017
  • An urban railway power substation consists of three thyristor dual converters. Two converters are connected to up and down trolley line to supply the electric energy or feed the regenerative energy back to the distribution. When the two converters break down, the remaining converter is used in an emergency. One thyristor dual converter system (TDCS) manages the energy of two or three railway stations. If the TDCS fails, the trains stop operating. To solve the problem, this paper proposes the three parallel operation control algorithm of thyristor dual converter system using the emergency converter. The broken TDCS can be replaced by the emergency converter in other TDCS. The effectiveness of this proposed control is verified by simulation.

철도 변전설비를 위한 싸이리스터 이중 컨버터 전력 시스템의 제어 기법 (Control Algorithm of Thyristor Dual Converter Power System for Railway Power Substations)

  • 한성우;이창희;김영우;문동옥
    • 전력전자학회논문지
    • /
    • 제20권6호
    • /
    • pp.573-579
    • /
    • 2015
  • A control algorithm of thyristor dual converter power system is proposed in this study for a railway power substation. The thyristor dual converter can use regenerative power without an additional system using control algorithm. An autonomous voltage and mode change method is also proposed to provide uninterrupted power to the railway. A 10 kW reduced model of the thyristor dual converter power system is built and tested to verify the validity of the proposed control algorithm.

도시철도의 직류전력 공급을 위한 사이리스터를 사용한 병렬 듀얼 컨버터의 순차적 모드 전환 제어 알고리즘에 대한 연구 (A Studies for Sequential Mode Change Control Algorithm of the Parallel Dual Converter of Using Thyristor for Supplying the Urban Railway DC Power)

  • 한성우;김성안;조윤현;변기식
    • 전기학회논문지
    • /
    • 제65권3호
    • /
    • pp.511-519
    • /
    • 2016
  • This paper is proposed control algorithm for the using thyristor of the parallel dual converter for Urban railway power supply in order to return the regenerative power generated by regenerative braking in urban railway train. Conventional control algorithm of Thyristor dual converter for urban railway power supply has voltage variation within a control range of hysteresis band. The purposed control algorithm of the parallel thyristor dual converter is to maintain a constant voltage without voltage variation in accordance with variable load through the Sequential mode change. And the control algorithm need calculating optimum initial firing angle to consider magnitude of the load current slope. For this purpose, Proposed algorithm for sequential conversion mode of the dual converter was verified by applying for the simulation.

철도 직류 급전용 싸이리스터 이중 컨버터 전력 시스템의 병렬운전 기법 (Parallel Control Algorithm of Thyristor Dual Converter Power System for DC Power Substation of Railway)

  • 김영우;문동옥;이창희
    • 전력전자학회논문지
    • /
    • 제22권1호
    • /
    • pp.9-17
    • /
    • 2017
  • A parallel control algorithm of thyristor dual-converter power system for the DC power supply of railway is proposed. The circulating current and current imbalance generated during parallel operation can be limited to control the output voltage of each power system by using the proposed parallel control algorithm. The proposed control algorithm can also eliminate output current sensor to achieve the same output response without additional costs. The validity of the proposed algorithm is verified through simulation and experiment.

교류 입력 전압 변동에 따른 사이리스터 듀얼 컨버터의 출력 특성 개선을 위한 알고리즘 개발 (Algorithm Development for Improving Output Characteristics of Thyristor Dual Converter with AC Input Voltage Variation)

  • 김성안;한성우;조윤현
    • 전기학회논문지
    • /
    • 제66권9호
    • /
    • pp.1437-1443
    • /
    • 2017
  • Electric energy is consumed or regenerated according to an operation of electric rail cars in urban railway power substations. A thyristor dual converter system is used to deal with the electric energy. Since the AC input voltage of power substations is $22.9kV{\pm}10%$, the magnitude of the AC voltage fluctuates according to load conditions, so the secondary side voltage of the DDY transformer also fluctuates. In the thyristor dual converter, the response characteristics of the DC output voltage and the DC output current are changed based on an initial firing angle in the cross mode conversion between the forward mode and the reverse mode. Therefore, this paper proposes the initial firing angle tracking algorithm considering fluctuation of the AC input voltage. The effectiveness of the proposed algorithm is verified by a simulation compared with the conventional algorithm.

철도 직류 급전용 싸이리스터 이중 컨버터 전력 시스템의 병렬운전에 대한 연구 (A Study on the Parallel Control Algorithm of Thyristor Dual Converter Power System for DC Power substation of Railway)

  • 김영우;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.314-315
    • /
    • 2017
  • 본 논문에서는 철도 직류 급전용 싸이리스터 이중 컨버터 전력 시스템의 병렬운전 제어기법을 제안한다. 싸이리스터 이중 컨버터 전력 시스템의 병렬운전 시 발생하는 순환전류 및 전류 불균형은 제안하는 병렬운전 기법을 통해 제어가 가능하다. 또한 제안하는 제어 기법은 동일한 응답을 가지면서 출력 측 전류 센서의 제거가 가능하다. 제안하는 제어기법의 타당성은 10kW급 축소모델의 시험을 통해 검증하였다.

  • PDF

항만하역장비용 직류전동기의 속도제어에 관한 연구 (A Study on DC Motor Speed Control for Building a Port Cargo Handling Equipment)

  • 안병원;박중순
    • 한국항만학회지
    • /
    • 제11권2호
    • /
    • pp.273-280
    • /
    • 1997
  • Recently the importance of the cargo handling equipments in a port has been increasing to get strong competition from other ports. Many ports are making efforts to modernize their cargo handling equipments. The kernel technology of such equipments is the speed control of DC motor which is used as an essential part of them. In this paper, we discuss the speed control of a DC motor as a basic work for building cargo handling equipments in a port. DC Motors are still widely used in industrial fields, as driving power motor for electrical fields. DC drives, being easy to control, are widely used in many variable-speed and position control drive system. Traditional analog control circuits used in such applications have many disadvantages. Complex control schemes are difficult to implement with analog components. All these factor and invention of the microprocessor has made it possible to use digital control circuits, using microprocessing system. These digital circuits have been found to be reliable, flexible, and also immune to noise. In this paper it presents the speed control of a SCR DC motor driver which using dual converter by 80c196kc microprocessor. We developed a thyristor power amplifier which does not cause damage thyristor because it is designed to prevent triggering the two SCRs in the same arm simultaneously. And it was analyzed voltage and currents wave at reactive load.

  • PDF

철도 변전설비를 위한 싸이리스터 듀얼 컨버터 실증시험 (Thyristor Dual Converter System Verification Test for Railway Power Substation)

  • 김병준;권국민;김영우;이창희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.320-321
    • /
    • 2019
  • 철도 변전설비를 위한 싸이리스터 듀얼 컨버터 시스템은 기존의 다이오드 정류기로 구성된 변전설비 시스템과는 다르게 전동차 제동 시 발생하는 에너지를 안정적으로 계통(22.9kV)에 전달 가능하다. 본 논문에서는 싸이리스터 듀얼 컨버터의 실증 시험을 통해 기존에 제안된 제어기법을 검증하였다. 실증 시험의 경우 부산 호포 차량기지(전동차 6량 1편성) 시험용 전동차가 기동 시 싸이리스터 듀얼 컨버터에서는 882kW의 에너지를 공급하며, 제동 시 시험용 전동차에서 싸이리스터 듀얼 컨버터로 756kW의 에너지가 회생되는 것을 확인 및 분석하여 본 시스템의 타당성을 검증하였다.

  • PDF