• 제목/요약/키워드: Through Plate Type

Search Result 474, Processing Time 0.038 seconds

판상형 산화아연의 합성 및 응용에 관한 연구 동향

  • Jang, Ui-Sun
    • Ceramist
    • /
    • v.20 no.4
    • /
    • pp.55-73
    • /
    • 2017
  • As one of the most versatile semiconductors, zinc oxide (ZnO) with one-dimensional (1-D) nanostructures has been significantly developed for the application of ultraviolet (UV) lasers, photochemical sensors, photocatalysts, and so on. Such 1-D nanowires could be easily achieved due to the anisotropic growth rate along the [0001] direction. However, such typical growth habit leads to decrease the surface area of the (0001) plane, which plays a central role in not only UV lasing action but also photocatalytic reaction. This fact lead us to develop ZnO crystal with enhanced polar surface area through crystal growth control. The purpose of this review is to provide readers a simple route to plate-type ZnO crystal with highly enhanced polar surfaces and their applications for UV-laser, photocatalyst, and antibacterial agents. In addition, we will highlight the recent study on pilot-scale synthesis of plate-type ZnO crystal for industrial applications.

The basic study of the detail development of the Wall-type APT joint using Slip Form and Deck plate. (Slip Form과 Deck Plate를 채용한 벽식 APT의 접합부 Detail개발의 기초적 연구)

  • Lee, Hee-Doo;Park, Shin;Lim, Nam-Gi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.127-132
    • /
    • 2003
  • The purpose of current study is about how to construct wall-type APT in slip form and Deck plate applied different connection of materials that wall and slab. A proposal construct's solution is using the continuous a binding string that the main of contents are slab or stairs which horizon structure part construction is joined the vertical structure part, new we Proposed of 2 solution that new technology development. We'll suggest that the development is in the construct of higher stories APT more better other construction method. We expect that the new method is good but we have many things to solute themes. Thus, we decided that this development contents are needed that correct structural investigation and constructor's security of speciality and through a fact construct, correct verification.

  • PDF

Implementation of curved type a metallic plate system at the Bone contact (골 접촉 곡선형 금속 고정 시스템 구현)

  • Kim, Jeong-Lae
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.5
    • /
    • pp.285-292
    • /
    • 2007
  • This study was developed the metallic plate for fixation in the femur fracture for the orthopedic region and rigid fixation with plates has a firm place in fracture treatment. Most plates can be used for rigid as well as biological and dynamical fracture fixation. The device's designation and sizing has a specific with bending structural stiffness and strength, known meaning that is reliable regardless of the plate by the short type and long type. Short plate have a wrapping of femur and long plate have to preserve a pole of femur. The bending strength of the curved metallic long plate has to evaluate a 11,000N and The bending strength of the curved metallic short plate has to evaluate a 6,525N. The tensile stress through to press a plate is $1573N/m^2\;and\;1539N/m^2$. The device can be used to support Revision case of Hip Implant and to use a case of Hip screw compression of Hip Neck Fracture.

  • PDF

Ultrasonic ranging technique for obstacle monitoring above reactor core in prototype generation IV sodium-cooled fast reactor

  • Kim, Hoe-Woong;Joo, Young-Sang;Park, Sang-Jin;Kim, Sung-Kyun
    • Nuclear Engineering and Technology
    • /
    • v.52 no.4
    • /
    • pp.776-783
    • /
    • 2020
  • As the refueling of a sodium-cooled fast reactor is conducted by rotating part of the reactor head without opening it, the monitoring of existing obstacles that can disturb the rotation of the reactor head is one of the most important issues. This paper deals with the ultrasonic ranging technique that directly monitors the existence of possible obstacles located in a lateral gap between the upper internal structure and the reactor core in a prototype generation IV sodium-cooled fast reactor (PGSFR). A 10 m long plate-type ultrasonic waveguide sensor, whose feasibility has been successfully demonstrated through preliminary tests, was employed for the ultrasonic ranging technique. The design of the sensor's wave radiating section was modified to improve the radiation performance, and the radiated field was investigated through beam profile measurements. A test facility simulating the lower part of the upper internal structure and the upper part of the reactor core with the same shapes and sizes as those in the PGSFR was newly constructed. Several under-water performance tests were then carried out at room temperature to investigate the applicability of the developed ranging technique using the plate-type ultrasonic waveguide sensor with the actual geometry of the PGSFR's internal structures.

Evaluation of Beam Behavior with External Bonded L-type GFRP Plate through bending Test (L형 GFRP 외부부착 보강된 보의 휨 실험을 통한 보강 거동분석)

  • Jeong, Yeong-Seok;Kwon, Min-Ho;Kim, Jin-Sup;Nam, Gwang-sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.86-93
    • /
    • 2020
  • The demand for maintenance in Korea infrastructure facilities constructed since the 1970s has increased significantly compared to the demand for new construction. Moreover, after the Gyeongju and Pohang earthquakes, seismic performance evaluation, repair, and retrofitting projects have been carried out. Therefore, in this study, a specimen was designed following the L-type GFRP Plate Externally Bonded Retrofit method, one among other retrofit methods. The L-type GFRP Plate was bonded to the specimen by epoxy and a washered steel nail. A four-point bending test was performed to confirm the strengthening effect of the Externally Bonded Retrofit method using an L-type GFRP Plate. The strengthening effect of the L-type GFRP plate was proven experimentally, and the behavior of the beam designed following the L-type GFRP Plate Externally Bonded Retrofit method was evaluated according to Korea's "Design Manual & Specification for Strengthening of RC Structures by Advanced Composites System". Furthermore, the effectiveness of the bonding method, a combination of epoxy and washered steel nail, was also checked. The results showed that the design, according to the guidelines mentioned above, predicted the strength of the member well, but the failure mode did not satisfy the design assumption because of unexpected damage to the GFRP plate due to the fixing method, washered steel nail.

Results of Arthroscopic-assisted Minimally Invasive Removal of a Lateral Periarticular Plate used for the Treatment of AO Type-C Distal Femoral Fractures (AO C-형 원위 대퇴골 골절의 치료로 삽입된 관외측 금속판의 절경 보조하 최소 침습적 제거의 결과)

  • Kim, Young-Mo;Lee, June-Kyu;Yang, Jae-Hoon;Kim, Bo-Kun;Lee, Won-Gu
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.46-52
    • /
    • 2009
  • Purpose: To evaluate the usefulness of minimally invasive arthroscopy-assisted plate removal of a laterally inserted periarticular distal femur plate used for the treatment of AO type-C distal femur fractures. Materials and Methods: From October 2002 to November 2005, we evaluated 17 patients whose plates were removed through minimally invasive arthroscopy-assisted plate-removal technique and 15 patients who got their plates removed through conventional method without using arthroscopy, 32 patients in total. All these patients included in this study initially underwent open reduction and internal fixation of the distal femoral fractures with a lateral plate, and complained of continued pain over the lateral femoral condyle after the fracture fixation. The average age was 42.6 (ranges: 20~66) and initial fracture types included 16 cases of C1, 11 cases of C2, and 5 cases of C3 following AO/ASIF classification guidelines. Measured outcomes included: associated intra-articular pathologies, time needed to return to activities of daily living, patients' overall satisfaction, complications following the removal of hardware, and pain before and 6 months after the operation. Results: The distal-most end of the plate was placed in the knee joint in all cases and damage of the lateral articular capsule was found in 23 cases. Continuous wound discharge after surgery was found in one case who underwent arthroscopy-assisted plate removal, and it was treated by irrigation and re-suture. Average time needed to return to activities of daily living was 7 days in arthroscopy assisted group and 7.6 days in conventionally removed group. Fourteen patients (82.4%) who underwent arthroscopyassisted plate-removal reported above 'fair' satisfaction and the Visual analog scale pain score decreased from 4.9 to 1.9, six months after the plate removal. Thirteen patients(86.7%) who underwent conventional plate removal reported above 'fair' satisfaction and the Visual analog scale pain score decreased from 5.2 to 2.5, six months after the operation. Conclusion: Through minimally invasive arthroscopic-assisted plate removal, intrarticular pathology of the knee joint was able to be simultaneously identified and treated at the time of hardware removal. Damage of lateral capsule of the knee joint caused by the inserted plate for the treatment of type C distal femoral fracture was very frequently found and following the plate removal, patients experienced an improvement in pain score. We therefore recommend routine lateral distal femoral plate removal if the bony union is attained in such cases as type C distal femoral fractures whose distal most end of the plates are located in the joint.

  • PDF

Visualization of Vortex Flow around Coolant Outlets Using PIV and LDV (PIV와 LDV를 이용한 냉각수 토출구 주위의 와류 가시화 연구)

  • Hong, Ji-Woo;Shin, Su-Yong;Ahn, Byoung-Kwon
    • Journal of the Korean Society of Visualization
    • /
    • v.19 no.3
    • /
    • pp.136-142
    • /
    • 2021
  • Submerged and semi-submerged vehicles expel cooling water through an outlet. In this process, induced noise and vibration by the flow around the outlet have been reported, and it may cause problems directly related to survivability of the navy vessels. The coolant outlet has a net-type structure and circular columns are mostly used. In this study, flow measurements using PIV and LDV were performed for different type outlets; conventional (flat plate with round bar) and improved (flat and flat plate) configurations. Experiments were conducted at a cavitation tunnel where pressure and steady flow rate conditions are ensured for sufficient time to measure the flow. The average velocity field of the outlets were measured and compared through LDV measurements, and instantaneous vorticities were evaluated through PIV measurements. The results show that the improved type of the outlet is advantageous in terms of flow stability compared to the conventional type of the outlet.

Design of Partial Half-Through Type Plate Girder Railway Bridge (부분중로형 판형 철도교의 계획과 설계)

  • Kim, Sung-Won;Kwon, So-Jin;Kim, Jong-Hee;Han, Chul
    • Proceedings of the KSR Conference
    • /
    • 2001.10a
    • /
    • pp.299-303
    • /
    • 2001
  • In this paper, we introduce the Partial Half-Through Type Plate Girder Bridge proposed by Hyundai Development Co. and KRTC Consortium in Turn-Key Based design last year, and this type of bridge may be adapted to the railway bridge under similar conditions. This bridge across the North Han River was to be concerned its find view and the protection of water source. For its location is inside the dam, it required the long span and the clearance for the flood also. Its new composite section was able to diminish the deflection and vibration. Its shop-fabrication could control its quality easily, and might to be launched. This structural type have satisfied its functions, construction situations, and overall safeties, so this is the field-oriented type. However the composition and connections of the proposed members are different to the recent forms, and difficult to be applied to present specifications. Therefore it requires a certification on the application for more safety by not only analytical verifications but also experimental studies. Nevertheless, this type of bridge may have some more applications from now on.

  • PDF

Thermal buckling analysis of embedded graphene-oxide powder-reinforced nanocomposite plates

  • Ebrahimi, Farzad;Nouraei, Mostafa;Dabbagh, Ali;Rabczuk, Timon
    • Advances in nano research
    • /
    • v.7 no.5
    • /
    • pp.293-310
    • /
    • 2019
  • In this paper, thermal-buckling behavior of the functionally graded (FG) nanocomposite plates reinforced with graphene oxide powder (GOP) is studied under three types of thermal loading once the plate is supposed to be rested on a two-parameter elastic foundation. The effective material properties of the nanocomposite plate are considered to be graded continuously through the thickness according to the Halpin-Tsai micromechanical scheme. Four types of GOPs' distribution namely uniform (U), X, V and O, are considered in a comparative way in order to find out the most efficient model of GOPs' distribution for the purpose of improving the stability limit of the structure. The governing equations of the plate have been derived based on a refined higher-order shear deformation plate theory incorporated with Hamilton's principle and solved analytically via Navier's solution for a simply supported GOP reinforced (GOPR) nanocomposite plate. Some new results are obtained by applying different thermal loadings to the plate according to the GOPs' negative coefficient of thermal expansion and considering both Winkler-type and Pasternak-type foundation models. Besides, detailed parametric studies have been carried out to reveal the influences of the different types of thermal loading, weight fraction of GOP, aspect and length-to-thickness ratios, distribution type, elastic foundation constants and so on, on the critical buckling load of nanocomposite plates. Moreover, the effects of thermal loadings with various types of temperature rise are investigated comparatively according to the graphical results. It is explicitly shown that the buckling behavior of an FG nanocomposite plate is significantly influenced by these effects.

A Study on Design of Notches in Valve Plate of Swash Plate Type Axial Piston Pumps Operated Bi-directionally (양방향 구동 사판식 액시얼 피스톤 펌프의 밸브 플레이트 노치 설계에 관한 연구)

  • Choi, Sae Ryung;Lee, Ill Yeong;Han, Sung Min;Shin, Jung Woo
    • Journal of Drive and Control
    • /
    • v.13 no.3
    • /
    • pp.39-46
    • /
    • 2016
  • Flow and pressure ripple in swash plate type piston pumps is largely dependent on the design of notches(silencing grooves) in the valve plate. In uni-directional pumps, the basic design concept for notches in the valve plate could be said to be established. It is easily deduced that the design concept for notches in uni-directional pumps can not be simply applied to bi-directional pumps requested for EHA(electric hydrostatic actuators). To carry out systematic research on technological issues regarding notch applications to bi-directional piston pumps, five notch designs are devised. The effects of the notch designs on the characteristics of the pump are investigated by numerical simulations and experiments. Through this study, basic concepts about notch design for bi-directional piston pumps are suggested.