• Title/Summary/Keyword: Threshold concentration

Search Result 465, Processing Time 0.031 seconds

Corrosion Characteristics of Steel Reinforcements Induced by Internal Chlorides in Concrete and Determination of Chloride Thresholds (콘크리트 내부염소이온에 의한 철근의 부식특성 및 임계 염소이온농도의 결정 연구)

  • 오병환;장승엽;신용석
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.3
    • /
    • pp.193-203
    • /
    • 1999
  • The corrosion of steel reinforcements in concrete is of great concern in recent years. This study is focused on the corrosion behavior of steel bars induced by internal chlorides in concrete at early ages. The main objective of this study is to determine the chloride thresholds causing depassivation and active corrosion of steel reinforcement in concrete. To examine the threshold concentration of chloride ion, the half-cell potential, chemical composition of expressed pore solutions of concrete and the rate of corosion area of the specimens were measured. Major variables include the added amount of chlorides in concrete, types of binders, and water-to-binder ration. From the present comprehensive experimental results, the factors influencing chloride-induced corrosion are investigated, and the chloride thresholds causing active corrosion of steel bars are proposed. The present study will enable to specify the realistic chloride limit in concrete which can be used in the future technical specification.

FIELD EMISSION CHARACTERISTICS OF DIAMOND FILMS

  • Park, Kyung-Ho;Lee, Soon-Il;Koh, Ken-Ha;Park, Jung-Il;Park, Kwang-Ja
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.5
    • /
    • pp.505-511
    • /
    • 1996
  • The field emission characteristics of diamond films deposited by microwave plasma enhanced chemical vapor deposition (MPECVD) method were investigated. Diamond films were deposited on n-type Si(100) wafer using various mixtures of hydrogen and methane gas, and the I-V characteristics are measured. We observed that the field emission characteristics depend on the $CH_4$ concentration and the diamond film thickness. All the films show remarkable emission characteristics; low turn-on voltage, high emission current density at lower voltage, uniform stable current density, and good stability and reproducibility. The threshold field for producing a current density of 1mA/$\textrm{cm}^2$ is found as low as 7.6V/$\mu\textrm{m}$.

  • PDF

CONDUCTIVITY of a-C:H FILMS MODIFIED WITH Ag NANOCLUSTERS

  • Sarsembinov, Sh.Sh.;Mahmoud, F.A.;Prikhodko, O.Yu.;Ryaguzov, A.P.;Maksimova, S.Ya.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.403-404
    • /
    • 2005
  • The conductivity of diamond like carbon films embedded with silver nanoclusters were investigated as a function of silver concentrations in the film. By increasing the concentration of silver in the film from 0 to 20 at% the conductivity varied from $10^{-13}$ to $10^2\;ohm^{-1}\;cm^{-1}$. The data have been discussed within the model of a dielectric matrix containing conductive inclusions. The conductivity data analysis using percolation theory has been showed that percolation threshold occurred at Ag percentage in the film $x_c$ =5 at %.

  • PDF

An Experimental Investigation of Particle Impingement Erosion in Hydraulic System (유압시스템의 입자 침해 침식의 실험적 고찰)

  • 이재천
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.15-21
    • /
    • 2001
  • This study assesses the wear process of particle impingement erosion which is a major source of erosion among fluid power components. First, Bitter's theory was modified to simplify engineering calculations. Second, actual experiments were conducted to validate the modified equation. And the effect of concentration and size distribution of impinging particles was tested. Little deviation from the prediction of the modified equation was observed. To develop an analytical approach to the erosion mechanism, further experimental data are required to establish a correlation with other engineering parameters.

  • PDF

Investigation on Electrical Property of Amorphous Oxide SiZnSnO Semiconducting Thin Films (비정질 산화물 SiZnSnO 반도체 박막의 전기적 특성 분석)

  • Byun, Jae Min;Lee, Sang Yeol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.4
    • /
    • pp.272-275
    • /
    • 2019
  • We investigated the electrical characteristics of amorphous silicon-zinc-tin-oxide (a-SZTO) thin films deposited by RF-magnetron sputtering at room temperature depending on the deposition time. We fabricated a thin film transistor (TFT) with a bottom gate structure and various channel thicknesses. With increasing channel thickness, the threshold voltage shifted negatively from -0.44 V to -2.18 V, the on current ($I_{on}$) and field effect mobility (${\mu}_{FE}$) increased because of increasing carrier concentration. The a-SZTO film was fabricated and analyzed in terms of the contact resistance and channel resistance. In this study, the transmission line method (TLM) was adopted and investigated. With increasing channel thickness, the contact resistance and sheet resistance both decreased.

Study on Electric Characteristics of IGBT Having P Region Under Trench Gate (Trench Gate 하단 P-영역을 갖는 IGBT의 전기적 특성에 관한 연구)

  • Ann, Byoung Sub;Yuek, Jinkeoung;Kang, Ey Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.5
    • /
    • pp.361-365
    • /
    • 2019
  • Although there is no strict definition of a power semiconductor device, a general description is a semiconductor that has capability to control more than 1 W of electricity. Integrated gate bipolar transistors (IGBTs), which are power semiconductors, are widely used in voltage ranges above 300 V and are especially popular in high-efficiency, high-speed power systems. In this paper, the size of the gate was adjusted to test the variation in the yield voltage characteristics by measuring the electric field concentration under the trench gate. After the experiment Synopsys' TCAD was used to analyze the efficiency of threshold voltage, on-state voltage drop, and breakdown voltage by measuring the P- region and its size under the gate.

Design and Fabrication of MOSFET Type Hydrogen Gas Sensor Using MEMS Process (MEMS 공정기술을 적용한 MOSFET형 수소센서의 설계, 제작에 관한 연구)

  • Kim, Bum Joon;Kim, Jung Sik
    • Korean Journal of Metals and Materials
    • /
    • v.49 no.4
    • /
    • pp.304-312
    • /
    • 2011
  • In this study, MOSFET type micro hydrogen gas sensors with platinum catalytic metal gates were designed, fabricated, and their electrical characteristics were analyzed. The devised MOSFET Hydrogen Sensors, called MHS-1 and -2, were designed with a platinum gate for hydrogen gas adsorption, and an additional sensing part for higher gas sensitivity and with a micro heater for operation temperature control. In the electrical characterization of the fabricated Pt-gate MOSFET (MHS-1), the saturated drain current was 3.07 mA at 3.0 V of gate voltage, which value in calculation was most similar to measurement data. The amount of threshold voltage shift and saturated drain current increase to variation of hydrogen gas concentration were calculated and the hydrogen gas sensing properties were anticipated and analyzed.

Thiamine deficiency as one of the mechanisms for neurotoxicity induced by lead intoxication in rats.

  • Cheong, Jae-Hoon;Ryu, Jae-Ryeon;Kim, Hye-Chung;Lee, Sang-Derk;Ko, Kwang-Ho
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1995.10a
    • /
    • pp.137-146
    • /
    • 1995
  • In this study, it was tested whether lead intoxication could change thiamine content and the thiamine related biochemical factor such as activity of transketolase in the brain, and whether the changes of the myelin composition :s well as the seizure threshold induced by lead intoxication in rats be related to these changes of thiamine status and thiamine related biochemical factors. In addition, it was also tested whether administration of excessive thiamine can reverse the toxic manifestation of lead in lead intoxicated animals. Five groups of Wistar rats were prepared: 1)Control group, 2)lead treated group, 3)thiamine treated group, 4)lead plus thiamine treated group and 5)thiamine deficiency group. Each group of animals was divided into three subgroups based on ages: 3, 7 and 10 weeks of age subgroups. Lead concentration, thiamine content, the activity of transketolase and myelin composition in brain areas and threshold of electric shock seizure were tested in each group. Lead concentrations in all brain regions of lead treated group were higher than those of control group, and those of lead plus thiamine treated group were significantly lower than those of lead treated group. Thiamine contents in the brain regions of lead treated group were significantly lower than those of control group, and those of lead plus thiamine treated group were recovered back to those of control group. Activities of transketolase of lead treated group were significantly lower than those of control group, while those of lead plus thiamine treated group were recovered back to those of control group. The cases of which was observed with the concomitant changes of thiamine content and transketolase activity in myelin content or constituent of all the brain regions tested were total amount of myelin protein in the cerebellum of 3 week old rats, and phospholipid in the cerebellum of 3 week old rats and the telencephalon of 16 week old rats. Thresholds of the electroshock seizure of lead-treated group and thiamine-deficient group in 3, 7 week old rats were significantly lower than those of control group, while those of the lead plus thiamine-treated group were similar to those of control group. Changes of the electroshock seizure threshold induced by lead intoxication were observed in 3 week and 7 week old animals with the concomitant decrement of thiamine content in all the brain regions tested. These observations were reversed by the supplementation with thiamine to those animals. However, the changes of seizure threshold induced by lead intoxication corelated with the changes of thiamine contents as well as. transketolase due to lead intoxication. The changes of myelin phospholipid as one of myelin composition and those of myelin Protein content only in the cerebellum of 3 week old rats correlated with the changes of the seizure threshold as well as thiamine content due to lead intoxication. The results from the present study may indicate that neurotoxicity of lead in rats may be mediated at least in part through the changes of thiamine status. Such changes of thiamine status may induce the changes of myelin composition such as myelin phospholipid and those of myelin protein content especially in the cerebellum of 3 week old rats which may eventually affect the threshold of seizure.

  • PDF

A Study on Exposure to Volatile Organic Compounds at Gas Stations in Korea (국내 일부 주유소 내에서의 휘발성 유기화합물 노출에 관한 연구)

  • Song, Sang Hwan;Paik, Nam Won;Ha, Kwon Chul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.1
    • /
    • pp.58-73
    • /
    • 2000
  • Objectives : This study was performed to evaluate BTEX exposure to gas station service attendants and the critical affect of benzene and MtBE airborne concentration. Methods : the degree of exposure to airborne BTEX and MtBE was examined in the service attendants at seven gas stations across the country during a summer season. The TWAs(time-weighted averages) of atmospheric concentration of substances in personal and area samples, were calculated. The component ratio of BTEX and MtBE in the samples of bulk gasoline from each station studied was also measured. Results : The airborne concentrations of BTEX and MtBE showed a lognormal distribution and The TWA concentrations of benzene in personal samples from each station were 0.089 ppm - 0.18 ppm, and those of toluene were 0.097 ppm - 0.2 ppm. The average TWA concentrations of xylene and ethyl benzene was 0.03 ppm and 0.001 ppm, respectively. The TWA concentrations of MtBE were 0.4 ppm - 1.3 ppm. The volume concentrations of MtBE, toluene, ethyl benzene and xylene in the bulk gasoline samples were 3 - 7.4 %, 3 - 12 %, 0.64 % and 1.5 - 10 %, respectively. Conclusions : The benzene concentration was detected to exceed the ACGIH threshold benzene level of 0.5 ppm, in one of 74 personal and area samples. MtBE, a substitute for aromatic compounds such as benzene in gasoline, was found to bring about a greater chance of exposure to carcinogen, due to its high vapor pressure and carcinogenicity.

  • PDF

A Bioreactor for the Effective Removal of the Hydrogen Sulfide from Biogas (바이오가스에 포함된 고농도 황화수소의 효율적 제거를 위한 미생물반응기)

  • Namgung, Hyeong-Kyu;Yoon, Chang No;Song, JiHyeon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.6
    • /
    • pp.811-817
    • /
    • 2013
  • A two-stage bioreactor system using sulfur-oxidizing bacteria was studied to abate high strength hydrogen sulfide ($H_2S$) from biogas. The two-stage bioreactor consisted of a $H_2S$ absorption column (0.5 L) and a microbial oxidation column (1 L) in series, and the liquid medium was continuously recirculated through the columns. The objectives of this study were to determine the feasibility of the bioreactor for biogas desulfurization and to investigate the effect of the medium circulation rate on the system performance. An averaged concentration of $H_2S$ introduced to the bioreactor was 530 ppm, corresponding to an overall loading rate of $44.4g/m^3/hr$. During the initial 20 days period at the medium recirculation rate of 8 reactor volumes per hour (12 L/hr), the dissolved oxygen (DO) concentration in the oxidation column was 6 mg/L, while the DO in the absorption column was 0.5 mg/L showing that the oxygen contents of the biogas stream was not altered. Because of the biological oxidation of $H_2S$ in the oxidation column, the sulfate concentration increased from 200 mg/L to 5,600 mg/L in the liquid medium. The removal efficiency of $H_2S$ was greater than 99% in the initial operation period. After the initial period, the medium recirculation rate between the two columns was stepwise changed eight times from 1.0 to 40 vol/hr (1.5~60 L/hr). At the recirculation rate of faster than 4 vol/hr, the $H_2S$ removal efficiencies were found to be high, but the efficiency declined at the lower recirculation rates than the threshold.