• Title/Summary/Keyword: Three-switch

Search Result 437, Processing Time 0.03 seconds

Advanced Three-Phase PFC Power Converters with Three-Phase Diode Rectifier and Four-Switch Boost Chopper

  • Nishimura Kazunori;Hirachi Katsuya;Hiraki Eiji;Ahmed Nabil A.;Lee Hyun-Woo;Nakaoka Mutsuo
    • Journal of Power Electronics
    • /
    • v.6 no.4
    • /
    • pp.356-365
    • /
    • 2006
  • This paper presents an improved three-phase PFC power rectifier with a three-phase diode rectifier cascaded four-switch boost converter. Its operating principle contains the operating principle of two conventional three-phase PFC power rectifiers: one switch boost converter type and a two switch boost converter type. The operating characteristics of the four switch boost converter type three-phase PFC power rectifier are evaluated from a practical point of view, being compared with one switch boost converter type and two switch boost converter topologies.

A Cognitive Evaluation of Hand Switch Layouts in the Main Control Board of Nuclear Power Plants (원자력 발전소 주 제어반의 제어 스위치 배치에 대한 인지적 수행도 평가)

  • Byun, Seong-Nam;Lee, Dong-Hoon
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.26 no.2
    • /
    • pp.136-145
    • /
    • 2000
  • The objective of this study is to evaluate the human performance relating to the layouts of the two different hand switch types with two and three buttons in the nuclear power plants. Using a computer simulation, the cognitive performance for the hand switch layouts was measured on the basis of response and task completion times. Comparative analyses were performed with three different layouts representing the current switch arrangements in the Yonggwang nuclear plants 5 and 6 and Ulchin 3 and 4, respectively. Statistical analyses revealed that the performance of the two-buttoned switch layouts was found to be better than those of the three-buttoned switch. Furthermore, the superiority of the two-buttoned switch type is consistent regardless of various layout types. These results imply that the difference of the cognitive performance can be attributable to the switch types rather than to the switch layouts. Therefore, from the cognitive perspective, the two-buttoned switch type is recommended for future power nuclear plants.

  • PDF

Driving Algorithm on Three Phase BLDC Motor Applied 4-Switch using Voltage Doubler (Voltage Doubler를 이용한 4-스위치 3상 BLDC 전동기 구동 알고리즘)

  • Yoon, Yong-Ho;Lee, Jung-Suk;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.1
    • /
    • pp.48-52
    • /
    • 2011
  • Over the years, traditionally, six-switch three-phase inverters have been widely utilized for variable speed alternating current motor drives. Recently, some efforts have been made on the application of four-switch three phase inverter for uninterruptible power supply and variable speed drives. This is due to some advantages of the four-switch three phase inverter over the conventional six-switch three-phase inverters such as reduced price due to reduction in number of switches, reduced switching losses, reduced number of interface circuits to supply logic signals for the switches, simpler control algorithms to generate logic signals, less chances of destroying the switches due to lesser interaction among switches, and less real-time computational burden. However such as slow di/dt and speed limitation, are the inherent characteristics and main drawbacks of the four-switch configuration. Those problems can be overcome in conjugation with Voltage-doublers which has additional advantage, such as unity power factor correction.

POWER FACTOR CORRECTION OF CO2 WELDING MACHINE USING SINGLE-SWITCH THREE-PHASE AC/DC CONVERTER

  • Kim, Jse-Mun;Kim, Yuen-Chung;Ahn, Jung-Jun;Won, Chung-Yuen;Kim, Sei-Chan
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.663-667
    • /
    • 1998
  • This paper describes for reducing harmonic distortion on CO2 welding machine with nonlinear load characteristic using single-switch three-phase AC/DC converter. The low-order harmonic component amplitude of the phase current of single-switch three-phase discontinuous mode is calculated. Experimental results show that CO2 welding machine with single-switch three-phase AC/DC converter is effectively controlled with power factor correction for phase current during welding time.

  • PDF

An Evaluation of Operator Performance Related to the Switch Types in Man Control Rooms of the Nuclear Power Plants (주관적 작업부하 평가기법을 이용한 원자력 발전소 주제어반 제어 스위치 사용 인적 수행도 평가)

  • Byun, Seung-Nam
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.26 no.1
    • /
    • pp.54-65
    • /
    • 2000
  • The objective of this study is to evaluate the operator performance relating to hand switches with two or three buttons in the main control rooms of nuclear power plants. Based on the comparative analysis of the nuclear power plants, two different subjective workload-rating scales were used to evaluate the performance of 48 operators: the Overall Workload(OW) and National Aeronautics and Space Administration Task Load Index (NASA TLX). The survey questions consisting of the eight-items were asked to evaluate the operating experiences for the two different switch types. The OW scales ratings were applied to measure the workload of the switch-related tasks. The ratings revealed that signal detection tasks caused less workload in the three-buttoned-switch operators than the other switch group. However, in the switch operation tasks, the switch types did not show statistically significant effects on workload level. The NASA TLX scale ratings were performed based on detailed task scenarios that assumed the accident of small break loss of coolant, what we call, the small LOCH. The NASA TLX was administered to three different task groups: the reactor, the turbine, and the electric operator groups. Based on the NASA TLX, the two-buttoned switch groups showed higher workload than those with the three-buttoned switches. However, a statistically significant difference was found only in the reactor operator groups. When the current switch type was assumed to be changed for the other type, all of the three-buttoned switch groups were predicted to have higher workload than the other switch groups, respectively. The implications of these findings were discussed.

  • PDF

Three-Phase Three-Switch Buck-Type Rectifier Based on Current Source Converter for 5MW PMSG Wind Turbine Systems

  • Chae, Beomseok;Suh, Yongsug;Kang, Tahyun
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1501-1512
    • /
    • 2018
  • This paper proposes a three-phase three-switch buck-type converter as the MSC of a wind turbine system. Owing to a novel switching modulation scheme that can eliminate the unwanted diode rectifier mode switching state, the proposed system exhibits a satisfying ac voltage and current waveform quality and torque ripple up to the level of a typical current source rectifier even under a wide power factor operating range. The proposed system has been verified through simulations and HILS tests on a PMSG wind turbine model of 5MW/4160V. The proposed converter has been shown to provide a stator current THD of 3.9% and a torque ripple of 1% under the rated power condition. In addition to the inherent advantage of the reduced switch count of three-phase three-switch buck-type converters, the proposed switching modulation technique can make this converter a viable solution for the MSC placed inside of a nacelle, which is under severe volume, weight and mechanical vibration design limits.

A Current Control Algorithm for Torque Ripple Reduction of Four-Switch Three-Phase Brushless DC Motors (4스위치 3상 BLDC 전동기의 토크 리플 저감을 위한 전류제어 알고리즘)

  • 박상현;김태성;이병국;현동석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.126-133
    • /
    • 2004
  • In this paper, a new current control algorithm is proposed for four-switch three-phase brushless DC(BLDC) motor drives, which are suitable for low cost applications. A current reference generation scheme is developed and implemented to obtain high performance characteristics in the four-switch system, such as small torque ripple and fast dynamic speed/torque response. Especially, the proposed scheme can successfully reduce the torque ripple during commutations, so that it can be expected that the four-switch system can be much more practically applied for the industrial application areas.

Field Oriented Control for Induction Motor Using Four Switch Three Phases Inverter

  • Tuyen, Nguyen D.;Hoang, Nguyen M.;Lee, Hong-Hee;Chun, Tae-Won
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.216-218
    • /
    • 2008
  • This paper presents a space vector pulse width modulation (SVPWM) technique for four-switch three-phase (4S3P) inverter topology. The method aims to apply Field Oriented Control (FOC) of Induction motor using 4S3P. The simulations are carried out and the experimental results are given to verify the feasibility of this method.

  • PDF

Reduced Current Distortion of Three-Phase Three-Switch Buck-Type Rectifier using Carrier Based PWM in EV Traction Battery Charging Systems (전기 자동차 배터리 충전장치용 3상 3스위치 전류형 정류기의 전류 왜곡 감소를 위한 펄스 폭 변조 스위칭 기법)

  • Chae, Beomseok;Kang, Taewon;Kang, Tahyun;Suh, Yongsug
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.4
    • /
    • pp.375-387
    • /
    • 2015
  • This study investigates an economic and highly efficient power-converter topology and its modulation scheme for 60 kW rapid EV charger system. The target system is a three-phase three-switch buck-type rectifier topology. A new carrier-based PWM scheme, which is characterized by simple implementation using logic gates, is introduced in this paper. This PWM scheme replaces the diode rectifier equivalent switching state with an active switching state to produce the same effective current flowing path. As a result, the distortion of input current during the polarity reversal of capacitor line voltage can be mitigated. The proposed modulation technique is confirmed through simulation verification. The proposed modulation technique and its implementation scheme can expand the operation range of the three-phase three-switch buck-type rectifier with high-quality AC input and capacitor ripple current.