• Title/Summary/Keyword: Three-phase line-interactive

Search Result 19, Processing Time 0.044 seconds

Development of Three-Phase Line-Interactive Dynamic Voltage Restorer with Hybrid Detection Method (Hybrid 검출방식을 적용한 삼상 선로 응동형 DVR(Dynamic Voltage Restorer))

  • Jeong, Jong-Kyou;Han, Byung-Moon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.901_902
    • /
    • 2009
  • This paper describes the development of a three-phase Line-Interactive DVR(Dynamic Voltage Restorer), which is applied to Hybrid detection method and super-capacitor. The operational feasibility was verified through computer simulations with PSCAD/EMTDC software, and experimental will be work with 3kVA prototype. The developed system can compensates the input voltage sag and interruption within 2ms, in which the maximum allowable sensitive load, such as computer, communication equipment, automation equipment, and medical equipment. The developed system has a simple structure to be easily implemented with commercially available components and to be highly reliable in operation.

  • PDF

The Utility Power Factor Control system of Photovoltaic Power Generation System

  • Koh Kang-Hoon;Lee Hyun-Woo;Suh Ki-Young;Taniguchi Katsunori
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.673-676
    • /
    • 2001
  • The photovoltaic power generation system has a great future as clean energy instead of fossil fuel, which has many environmental problems such as exhausted gas or air pollution. In a utility interactive photovoltaic generation system, a three phase inverter is used for the connection between the photovoltaic array and the utility. This paper presents a three phase inverter for photovoltaic power system with current controller, voltage controller, PLL control system and the phase detector of interactive voltage by using dq transformation. The proposed inverter system provides a sinusoidal ac current for domestic loads and the utility line with unity power factor.

  • PDF

A Study on DC Changing Algorithm of the Line-Interactive UPS with Dual Converter Structure (2중 컨버터 구조를 갖는 계통 연계형 UPS의 DC 충전 알고리듬에 관한 연구)

  • Lee, Woo-Cheol;Yoo, Dong-Sang
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.27-34
    • /
    • 2005
  • This paper presents a three phase Line-Interactive uninterruptible power supply(UPS) system with dual converter structure. The three phase UPS system consists of two active power compensator topologies. One is a series active compensator, which works as a voltage source in phase with the source voltage to have the sinusoidal source current and high power factor under the deviation and distortion of the source voltage. The other is a parallel active compensator, which works as a conventional sinusoidal voltage source in phase with the source voltage, providing to the load a regulated and sinusoidal voltage with low total harmonic distortion(THD). This paper presents in the series and parallel active compensator charging method depending on the amplitude of the source voltage. The conventional Line-Interactive UPS system is responsible for the DC charging and output voltage regulation at the same time, but UPS system with dual converter structure, a series active compensator can also charge the DC link. Therefore the charging algorithm using the series and parallel compensator needs to be researched. Therefore, by making the DC link voltage stable it can contribute the stability of series and parallel compensator. The simulation and experimental result are depicted in this paper to show the effect of the proposed algorithm.

Rapid response control A Utility Interactive Photovoltaic Generation System (계통연계형 태양광발전 시스템의 속응성 제어)

  • Chung, Choon-Byeong;Jeon, Kee-Young;Lee, Sang-Hyun;Han, Kyung-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.279-285
    • /
    • 2007
  • Since the residential load is an AC load and the output of solar cell is a DC power, the photovoltaic system needs the DC/AC converter to utilize solar cell. In case of driving to interact with utility line, in order to operate at unity power factor, converter must provide the sinusoidal wave current and voltage with same phase of utility line. Since output of solar cell is greatly fluctuated by insolation, it is necessary that the operation of solar cell output in the range of the vicinity of maximum power point. In this paper, DC/AC converter is three phase PWM converter with smoothing reactor. And then, feedforward control used to obtain a superior characteristic for current control and digital PLL circuit used to detect the phase of utility line.

  • PDF

A Study on Utility Interactive Energy System using PWM Converter (PWM 컨버터를 이용한 계통연계 에너지시스템에 관한 연구)

  • Kim, Gil-Dong;Lee, Han-Min;Hong, Yong-Ki;Kim, Dea-Gyun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.288-291
    • /
    • 2007
  • Since the residential load is an AC load and the output of solar cell is a DC power, the photovoltaic system needs the DC/AC converter to utilize solar cell. In case of driving to interact with utility line, in order to operate at unity power factor, converter must provide the sinusoidal wave current and voltage with same phase of utility line. Since output of solar cell is greatly fluctuated by insolation, it is necessary that the operation of solar cell output in the range of the vicinity of maximum power point. In this paper, DC/AC converter is three phase PWM converter with smoothing reactor. And then, feedforward control used to obtain a superior characteristic for current control and digital PLL circuit used to detect the phase of utility line.

  • PDF

A Utility Interactive Photovoltaic Generation System using PWM Converter (PWM 컨버터를 이용한 계통연계형 태양광발전 시스템)

  • Kim, Dae-Gyun;Jeon, Kee-Young;Hahm, Nyon-Kun;Chung, Choon-Byeong;Lee, Seung-Hwan;Oh, Bong-Hwan;Lee, Hoon-Goo;Han, Kyung-Hee
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.3
    • /
    • pp.111-118
    • /
    • 2005
  • Since the residential load is an AC load and the output of solar cell is DC power, the photovoltaic system needs the DC/AC converter to utilize solar cell. In case of driving to interact with utility line, in order to operate at unity power factor, converter must provide the sinusoidal wave current and voltage with same phase of utility line. Since output of solar cell is greatly fluctuated by insolation, it is necessary that the operation of solar cell output in the range of the vicinity of maximum power point. In this paper, DC/AC converter is three phase PWM converter with smoothing reactor. And then, feed-forward control used to obtain a superior characteristic for current control and digital PLL circuit used to detect the phase of utility line.

A Utility Interactive Photovoltaic Generation System using PWM Converter (PWM 컨버터를 이용한 계통연계형 태양광발전 시스템)

  • Kim D. G.;Chung J. H.;Chung C. B.;Kim S. N.;Lee S. H.;Kang S. W.;Oh B. H.;Lee H. G.;Kim Y. J.;Han K. H.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.133-136
    • /
    • 2004
  • Since the residential load is an AC load and the output of solar cell is a DC power, the photovoltaic system needs the DC/AC converter to utilize solar cell. In case of driving to interact with utility line, in order to operate at unity power factor, converter must provide the sinusoidal wave current and voltage with same phase of utility line. Since output of solar cell is greatly fluctuated by insolation, it is necessary that the operation of solar cell output in the range of the vicinity of maximum power point. In this paper, DC/AC converter is three phase PWM converter with smoothing reactor. And then, feedforward control used to obtain a superior characteristic for current control and digital PLL circuit used to detect the phase of utility line.

  • PDF

A Utility Interactive Photovoltaic Generation System Using PWM Converter (PWM 컨버터를 이용한 계통연계형 태양광발전 시스템)

  • Chung, J.H.;Jho, J.M.;Jeon, K.Y.;Lee, S.H.;Oh, B.H.;Kim, S.N.;Kim, Y.J.;Han, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1253-1255
    • /
    • 2003
  • Since the residential load is an AC load and the output of solar cell is a DC Power, the photovoltaic system needs the DC/AC converter to utilize solar cell. In case of driving to interact with utility line, in order to operate at unity power factor, converter must provide the sinusoidal wave current and voltage with same phase of utility line. Since output of solar cell is greatly fluctuated by insolation. it is necessary that the operation of solar cell output in the range of the vicinity of maximum power point. In this paper DC/AC converter is three phase PWM converter with smoothing reactor. And then, feedforward control used to obtain a superior characteristic for current control and digital PLL circuit used to detect the phase of utility line.

  • PDF

New Control Scheme for LIDVR Considering Asymmetry Input Voltage Conditions (비대칭 입력 전압 상태를 고려한 LIDVR의 새로운 제어방법)

  • Han Chul-Woo;Kim Tae-Jin;Kang Dae-wook;Hyun Dong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.510-514
    • /
    • 2002
  • Power Quality and reliability are becoming important issues for critical and sensitive loads. The recent growth in the use of impactive and nonlinear loads has caused many power quality problems such as voltage flicks, harmonics and unbalances, which may cause the modem automatic devices to fail, misoperate, or shut down. This paper deals with 7-Level H-Bridge Line-Interactive Dynamic Voltage Restorer (LIDVR) system. It has the power factor near to unity under normal source voltage, can compensate the harmonic current of the load and instant interruption, and has the fast response. Currently, most of the DVR design studies are based on the assumption of the balanced three-phase system. But, actually line fault occurred $1{\phi}\;{sag}\;or\;2{\phi}$ sag. Hence, proposed new control scheme compensate asymmetry input voltage. Finally, simulation results verify the proposed 7-Level H-Bridge LIDVR system.