• Title/Summary/Keyword: Three-dimensional scanning system

Search Result 136, Processing Time 0.029 seconds

New Evaluation System of Cosmetic Effects on Morphology of Skin Surface Using TSRLM with Image Analyser

  • Kim, Jong-Il;Lee, Joa-Hoon;Lee, Yoo-Young;Kim, Chang-Kew
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.16 no.1
    • /
    • pp.47-63
    • /
    • 1990
  • Image analyser was used to understand the condition of skin surface and to evaluate the efficacy of cosmetic treatment. It was unsatisfactory to analyse skin surface structure although several methods using image analyser had been presented. We developed the new system composed of image analyser and Tandem Scanning Reflected Light Microscope (TSRLM) having the remarkable optical sectioning property as image input device. By using this new system, we quantitatively measured the change of skin surface, the depth and width of furrow in micron unit, resulted by cosmetic treatments. And also three dimensional image of skin was reconstructed with serial sectioned images, which were captured through TSRLM, for better understanding of the effect of cosmetic treatment. It was found that skin relief was more easily understood and the change of skin surface caused by cosmetic treatment was more accurately measured by using this system. In addition, we was also aware of the possibility of in vivo direct measurement of skin furrow without replica. It was conceivable that our system could be applicable for study of cosmetic effects further.

  • PDF

Matching for Cylinder Shape in Point Cloud Using Random Sample Consensus (Random Sample Consensus를 이용한 포인트 클라우드 실린더 형태 매칭)

  • Jin, YoungHoon
    • Journal of KIISE
    • /
    • v.43 no.5
    • /
    • pp.562-568
    • /
    • 2016
  • Point cloud data can be expressed in a specific coordinate system of a data set with a large number of points, to represent any form that generally has different characteristics in the three-dimensional coordinate space. This paper is aimed at finding a cylindrical pipe in the point cloud of the three-dimensional coordinate system using RANSAC, which is faster than the conventional Hough Transform method. In this study, the proposed cylindrical pipe is estimated by combining the results of parameters based on two mathematical models. The two kinds of mathematical models include a sphere and line, searching the sphere center point and radius in the cylinder, and detecting the cylinder with straightening of center. This method can match cylindrical pipe with relative accuracy; furthermore, the process is rapid except for normal estimation and segmentation. Quick cylinders matching could benefit from laser scanning and reverse engineering construction sectors that require pipe real-time estimates.

Fabrication of Three-Dimensional Micro Optical and Fluidic System Using Dual Stage Nanostereolithography Process (이중 스테이지를 이용한 대면적 3차원 광/유체 마이크로 디바이스 제작에 관한 연구)

  • Lim, Tae Woo;Yang, Dong-Yol
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.10
    • /
    • pp.552-557
    • /
    • 2015
  • The nanostereolithography process using a femtosecond laser has been shown to have strong merits for the direct fabrication of 2D/3D micro structures. In addition, a femtosecond laser provides efficient tools for precise micromachining owing to the advantages of a small and feeble heat effect zone. In this paper, we report an effective fabrication process of 3D micro optical and fluidic devices using nanostereolithography process composed of a dual stage system. Process conditions for additive and subtractive fabrication are examined. The Piezo stage scanning system is used for 3D micro-fabrication in unit area of sub-mm scale, and the motor stage is employed in fabrication on the scale of several mm. The misalignment between the pizeo- and motor- stages is revised through rotational transformation of CAD data in the unit domain. Here, the effectiveness of the proposed process is demonstrated through examples using 3D optical and microfluidic structures.

Restoration using dental CAD/CAM system in severe tooth wear patient: A case report

  • Kee, Wonjin;Kim, Hyeran;Lim, Hyun-Pil;Yun, Kwi-Dug;Park, Chan
    • Oral Biology Research
    • /
    • v.42 no.4
    • /
    • pp.262-268
    • /
    • 2018
  • In a situation where a vertical dimension has to be increased, the normal occlusion, function and aesthetics should be restored after taking into consideration the neuromuscular system and temporomandibular join. In order to do this, the provisional prosthesis should be made according to the patient's information. Moreover, the period of adjustment should be made through the provisional prosthesis modification, if necessary. The patient is then transferred to the final prosthesis to obtain results that are satisfactory. In the modern-day world, provisional prosthesis are replicated using three dimensional scanning and computer aided design/computer aided manufacturing (CAD/CAM) then made into final prosthesis. The adaptability of stomatognathic system can be judged by the PMMA provisional restoration. Functional and aesthetical aspect can be obtained. The adjustment period can be shortened by an intraoral correction and proper wear between provisional restorations. By using the CAD/CAM technology that transfers the information right into the final prosthesis.

Construction of Abalone Sensory Texture Evaluation System Based on BP Neural Network

  • Li, Xiaochen;Zhao, Yuyang;Li, Renjie;Zhang, Ning;Tao, Xueheng;Lee, Eung-Joo
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.7
    • /
    • pp.790-803
    • /
    • 2019
  • The effects of different heat treatments on the sensory characteristics of abalones are studied in this study. In this paper, the sensory evaluation of abalone samples under different heat treatment conditions is carried out, and the evaluation results are analyzed. The three-dimensional (3D) scanning and reverse engineering are used in tooth modeling of the sensory evaluation of abalone samples under different heat treatment conditions. Besides, the chewing movement models are simplified into three modes, including the cutting mode, compressing mode and grinding mode, which are simulated using finite element simulation. The elastic modulus of the abalone samples is obtained through the compression testing using a texture analyzer to distinguish their material properties under different heat treatments and to obtain simulated mechanical parameters. Finally, taking the mechanical parameters of the finite element simulation of abalone chewing as input and sensory evaluation parameters as the output, BP neural network is established in which the sensory texture evaluation model of abalone samples is obtained. Through verification, the neural network prediction model can meet the requirements of food texture evaluation, with an average error of 9.12%.

The comparison of accuracy on three-unit fixed dental prosthesis made with CAD/CAM milling machines (치과 캐드캠 밀링장비에 따른 3본브릿지의 정확도 비교)

  • Bae, So-Yeon;Park, Jin-Young;Kim, Ji-Hwan;Kim, Hae-Young;Kim, Myung-Bae;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.37 no.1
    • /
    • pp.9-15
    • /
    • 2015
  • Purpose: The purpose of this study was to compare the accuracy of the maxillary three-unit fixed dental prosthesis (FDPs) made using two CAD/CAM milling machines : DCM Group(Dentaim CAD/CAM milling machine), WCM Group(Wieland CAD/CAM milling machine). Methods: Each of 10 duplicate models was scanned by blue light scanner(Identica, Medit, Korea), and the three-unit FDPs (STL file) was designed using DelcamCAD. A total of 20 three-unit FDPs was fabricated, comprising 2 groups of 10 specimens each (shrinkage ratio is 1:1). The first three-unit FDPs STL file was used as a CAD reference model (CRM). Obtained STL files by scanning the inner surface of three-unit FDPs were convened into the point clouds-ASC II files. Discrepancies between the point clouds and CRM were measured by superimposition software. Statistical methods to analyze the data were used non-parametric method. The mean (SD) values were compared by a Mann-Whitney U-test. Type one error rate was set at 0.05. Results: WCM group had small discrepancies with $2.17{\mu}m$ of mean value compared to $4.44{\mu}m$ in DCM group. The accuracy values between the two groups showed a sratistically significant difference (Table 2, p<.05). Conclusion: The accuracy of the three-unit fixed dental prosthesis(FDPs) made of two CAD/CAM milling machines were statistically different. Accuracy with which the prosthesis made of WCM group was superior.

The Study of automated inspection technology using a three-dimensional reconstruction of stereo X-ray image based dual-sensor Environment (Dual-Sensor 기반 스테레오 X-선 영상의 3차원 형상복원기술을 이용한 검색 자동화를 위한 연구)

  • Hwang, Young-Gwan;Lee, Nam-Ho;Kim, Jong-Ryul
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.695-698
    • /
    • 2014
  • As most the scanning systems developed until now provide radiation scan plane images of the inspected objects, there has been a limitation in judging exactly the shape of the objects inside a logistics container exactly with only 2-D radiation image information. Two 2-dimensional radiation images which have different disparity values are acquired from a newly designed stereo image acquisition system which has one additional line sensor to the conventional system. Using a matching algorithm the 3D reconstruction process which find the correspondence between the images is progressed. In this paper, we proposed a new volume based 3D reconstruction algorithm and experimental results show the proposed new volume based reconstruction technique can provide more efficient visualization for cargo inspection. The proposed technique can be used for the development of the high speed and more efficient non-destructive auto inspection system.

  • PDF

Effect of seeding using an avidin-biotin binding system on the attachment of periodontal ligament fibroblasts to nanohydroxyapatite scaffolds: three-dimensional culture

  • Jang, Yong-Ju;Jung, Im-Hee;Park, Jung-Chul;Jung, Ui-Won;Kim, Chang-Sung;Lee, Yong-Keun;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.41 no.2
    • /
    • pp.73-78
    • /
    • 2011
  • Purpose: For periodontal tissue engineering, it is a primary requisite and a challenge to select the optimum types of cells, properties of scaffold, and growth factor combination to reconstruct a specific tissue in its natural form and with the appropriate function. Owing to fundamental disadvantages associated with using a two-dimensional substrate, several methods of seeding cells into three-dimensional scaffolds have been reported and the authors have asserted its usefulness and effectiveness. In this study, we explore the cell attachment of periodontal ligament fibroblasts on nanohydroxyapatite (n-HA) scaffold using avidin biotin binding system (ABBS). Methods: Human periodontal ligament fibroblasts were isolated from the health tooth extracted for the purpose of orthodontic procedure. HA nanoparticles were prepared and $Ca(NO_3)_2-_4H_2O$ and $(OC_2H_5)_3P$ were selected as precursors of HA sol. The final scaffold was 8 mm in diameter and 3 mm in height disk with porosity value of 81.55%. $1{\times}10^5$ periodontal ligament fibroblasts were applied to each scaffold. The cells were seeded into scaffolds by static, agitating and ABBS seeding method. Results: The number of periodontal ligament fibroblasts attached was greater for ABBS seeding method than for static or agitating method (P<0.05). No meaningful difference has been observed among seeding methods with scanning electron microscopy images. However, increased strength of cell attachment of ABBS could be deduced from the high affinity between avidin and biotin ($Kd=10^{-15}\;M$). Conclusions: The high-affinity ABBS enhances the ability of periodontal ligament fibroblasts to attach to three-dimensionally constructed n-HA scaffold.

3D Image Analysis for Digital Restoration and Structural Stability Evaluation of Stone Cultural Heritage: Five-storied Magoksa Temple Stone Pagoda (석조문화재 디지털복원 및 구조안정성 평가를 위한 3차원 영상분석: 마곡사오층석탑)

  • Jo, Young-Hoon;Lee, Chan-Hee
    • Journal of Conservation Science
    • /
    • v.25 no.2
    • /
    • pp.115-130
    • /
    • 2009
  • This study was focused on digital restoration and structural stability evaluation applying 3D scanning system of five-storied Magoksa temple stone pagoda in Gongju. For these, the digital restoration of the pagoda was completed using laser scan data which is measured 16 directions and data processing program of 7 stages. As a result of digital restoration, the overall height and width of stone properties showed a little difference in directions and the width of roof stones appeared very high difference of each floor. The width of pagoda body become smaller to the fifth floor, but gradual decrease rate showed irregular characteristics. Also, as result of 3D image analysis for structural stability evaluation, the displacement occurred toward northwest in second body stone to upper final stone except for central axis of the first body stone which inclines toward southwest. Such 3D image analysis is required quantification of survey method and should be applied to various field such as quantitative damage maps in order to utilize a conservation of stone cultural heritages, continuously.

  • PDF

Serial Block-Face Imaging by Field Emission Scanning Electron Microscopy (전계방사형 주사전자현미경에 의한 연속블록면 이미징)

  • Kim, Ki-Woo
    • Applied Microscopy
    • /
    • v.41 no.3
    • /
    • pp.147-154
    • /
    • 2011
  • Backscattered electrons (BSE) are generated at the impact of the primary electron beam on the specimen. BSE imaging provides the compositional contrast to resolve chemical features of sectioned block-face. A focused ion beam (FIB) column can be combined with a field emission scanning electron microscope (FESEM) to ensure a dual (or cross)-beam system (FIB-FESEM). Due to the milling of the specimen material by 10 to 100 nm with the gallium ion beam, FIB-FESEM allows the serial block-face (SBF) imaging of plastic-embedded specimens with high z-axis resolution. After contrast inversion, BSE images are similar to transmitted electron images by transmission electron microscopy. As another means of SBF imaging, a specialized ultramirotome has been incorporated into the specimen chamber of FESEM ($3View^{(R)}$). Internal structures of plastic-embedded specimens can be serially revealed and analyzed by $3View^{(R)}$ with a large field of view to facilitate three-dimensional reconstruction. These two SBF approaches by FESEM can be employed to unravel spatial association of (sub)cellular entities for a comprehensive understanding of complex biological systems.