• 제목/요약/키워드: Three-dimensional facial images

검색결과 87건 처리시간 0.028초

안면골 외상환자의 전산화단층상을 이용한 삼차원재구성상의 비교연구 (A COMPARATIVE STUDY OF THREE DIMENSIONAL RECONSTRUCTIVE IMAGES USING COMPUTED TOMOGRAMS OF FACIAL BONE INJURIES)

  • 최은숙;고광준
    • 치과방사선
    • /
    • 제24권2호
    • /
    • pp.413-423
    • /
    • 1994
  • The purpose of this study was to clarify the spatial relationship in presurgical examination and to aid surgical planning and postoperative evaluation of patients with facial bone injury. For this study, three-dimensional images of facial bone fracture were reconstructed by computed image analysis system and three-dimensional reconstructive program integrated in computed tomography. The obtained results were as follows: 1. Serial conventional computed tomograms were value in accurately depicting the facial bone injuries and three-dimensional reconstructive images demonstrated an overall look. 2. The degree of deterioration of spatial resolution was proportional to the thickness of the slice. 3. Facial bone fractures were the most distinctly demonstrated on inferoanterior views of three-dimensional reconstructive images. 4. Although three-dimensional reconstructive images made diagnosis of fracture lines, it was difficult to identify maxillary fractures. 5. The diagnosis of zygomatic fractures could be made equally well with computed image analysis system and three-dimensional reconstructive program integrated in computed tomography. 6. The diagnosis of mandibular fractures could be made equally well with computed image analysis system and three-dimensional reconstructive program integrated in computed tomography.

  • PDF

Image-based Realistic Facial Expression Animation

  • Yang, Hyun-S.;Han, Tae-Woo;Lee, Ju-Ho
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 1999년도 KOBA 방송기술 워크샵 KOBA Broadcasting Technology Workshop
    • /
    • pp.133-140
    • /
    • 1999
  • In this paper, we propose a method of image-based three-dimensional modeling for realistic facial expression. In the proposed method, real human facial images are used to deform a generic three-dimensional mesh model and the deformed model is animated to generate facial expression animation. First, we take several pictures of the same person from several view angles. Then we project a three-dimensional face model onto the plane of each facial image and match the projected model with each image. The results are combined to generate a deformed three-dimensional model. We use the feature-based image metamorphosis to match the projected models with images. We then create a synthetic image from the two-dimensional images of a specific person's face. This synthetic image is texture-mapped to the cylindrical projection of the three-dimensional model. We also propose a muscle-based animation technique to generate realistic facial expression animations. This method facilitates the control of the animation. lastly, we show the animation results of the six represenative facial expressions.

전산화단층상을 이용한 안면골의 3차원재구성상의 비교 연구 (COMPARATIVE STUDY OF THREE-DIMENSIONAL RECONSTRUCTIVE IMAGES OF FACIAL BONE USING COMPUTED TOMOGRAPHY)

  • 송남규;고광준
    • 치과방사선
    • /
    • 제22권2호
    • /
    • pp.283-290
    • /
    • 1992
  • The purpose of this study was to evaluate the spatial relationship of facial bone more accurately. For this study, the three-dimensional images of dry skull were reconstructed using computer image analysis system and three-dimensional reconstructive program involved CT. The obtained results were as follows: 1. Three-dimensional reconstructive CT results in images that have better resolution and more contrast 2. It showed good marginal images of anatomical structure on both three-dimensional CT and computer image analysis system, but the roof of orbit, the lacrimal bone and the squamous portion of temporal bone were hardly detectable. 3. The partial loss of image data were observed during the regeneration of saved image data on three-dimensional CT. 4. It saved the more time for reconstruction of three-dimensional images using computer image analysis system. But, the capacity of hardware was limited for inputting of image data and three-dimensional reconstructive process. 5. We could observe the spatial relationship between the region of interest and the surrounding structures by three-dimensional reconstructive images without invasive method.

  • PDF

Validity of Three-dimensional Facial Scan Taken with Facial Scanner and Digital Photo Wrapping on the Cone-beam Computed Tomography: Comparison of Soft Tissue Parameters

  • Aljawad, Hussein;Lee, Kyungmin Clara
    • Journal of Korean Dental Science
    • /
    • 제15권1호
    • /
    • pp.19-30
    • /
    • 2022
  • Purpose: The purpose of the study was to assess the validity of three-dimensional (3D) facial scan taken with facial scanner and digital photo wrapping on the cone-beam computed tomography (CBCT). Materials and Methods: Twenty-five patients had their CBCT scan, two-dimensional (2D) standardized frontal photographs and 3D facial scan obtained on the same day. The facial scans were taken with a facial scanner in an upright position. The 2D standardized frontal photographs were taken at a fixed distance from patients using a camera fixed to a cephalometric apparatus. The 2D integrated facial models were created using digital photo wrapping of frontal photographs on the corresponding CBCT images. The 3D integrated facial models were created using the integration process of 3D facial scans on the CBCT images. On the integrated facial models, sixteen soft tissue landmarks were identified, and the vertical, horizontal, oblique and angular distances between soft tissue landmarks were compared among the 2D facial models and 3D facial models, and CBCT images. Result: The results showed no significant differences of linear and angular measurements among CBCT images, 2D and 3D facial models except for Se-Sn vertical linear measurement which showed significant difference for the 3D facial models. The Bland-Altman plots showed that all measurements were within the limit of agreement. For 3D facial model, all Bland-Altman plots showed that systematic bias was less than 2.0 mm and 2.0° except for Se-Sn linear vertical measurement. For 2D facial model, the Bland-Altman plots of 6 out of 11 of the angular measurements showed systematic bias of more than 2.0°. Conclusion: The facial scan taken with facial scanner showed a clinically acceptable performance. The digital 2D photo wrapping has limitations in clinical use compared to 3D facial scans.

안면 비대칭 환자의 하악골 수술 후 하악골 변화에 대한 3차원 CT 영상 비교 (Comparision of Mandible Changes on Three-Dimensional Computed Tomography image After Mandibular Surgery in Facial Asymmetry Patients)

  • 김미령;진병로
    • Journal of Yeungnam Medical Science
    • /
    • 제25권2호
    • /
    • pp.108-116
    • /
    • 2008
  • Background : When surgeons plan mandible ortho surgery for patients with skeletal class III facial asymmetry, they must be consider the exact method of surgery for correction of the facial asymmetry. Three-dimensional (3D) CT imaging is efficient in depicting specific structures in the craniofacial area. It reproduces actual measurements by minimizing errors from patient movement and allows for image magnification. Due to the rapid development of digital image technology and the expansion of treatment range, rapid progress has been made in the study of three-dimensional facial skeleton analysis. The purpose of this study was to conduct 3D CT image comparisons of mandible changes after mandibular surgery in facial asymmetry patients. Materials & methods : This study included 7 patients who underwent 3D CT before and after correction of facial asymmetry in the oral and maxillofacial surgery department of Yeungnam University Hospital between August 2002 and November 2005. Patients included 2 males and 5 females, with ages ranging from 16 years to 30 years (average 21.4 years). Frontal CT images were obtained before and after surgery, and changes in mandible angle and length were measured. Results : When we compared the measurements obtained before and after mandibular surgery in facial asymmetry patients, correction of facial asymmetry was identified on the "after" images. The mean difference between the right and left mandibular angles before mandibular surgery was $7^{\circ}$, whereas after mandibular surgery it was $1.5^{\circ}$. The right and left mandibular length ratios subtracted from 1 was 0.114 before mandibular surgery, while it was 0.036 after mandibular surgery. The differences were analyzed using the nonparametric test and the Wilcoxon signed ranks test (p<0.05). Conclusion: The system that has been developed produces an accurate three-dimensional representation of the skull, upon which individualized surgery of the skull and jaws is easily performed. The system also permits accurate measurement and monitoring of postsurgical changes to the face and jaws through reproducible and noninvasive means.

  • PDF

3D 스캔 데이터를 이용한 얼굴 애니메이션 시스템 (A Facial Animation System Using 3D Scanned Data)

  • 구본관;정철희;이재윤;조선영;이명원
    • 정보처리학회논문지A
    • /
    • 제17A권6호
    • /
    • pp.281-288
    • /
    • 2010
  • 본 논문에서는 3차원 얼굴 스캔 데이터와 사진 이미지를 이용하여 고화질의 3차원 얼굴 모델과 모핑 애니메이션을 생성하는 시스템 개발에 대해 기술한다. 본 시스템은 얼굴 특징점 입력 도구, 얼굴 텍스처매핑 인터페이스, 3차원 얼굴 모핑 인터페이스로 구성되어 있다. 얼굴 특징점 입력 도구는 3차원 텍스처매핑과 모핑 애니메이션을 위한 보조 도구로서 얼굴의 특징점을 입력하여 텍스처매핑과 임의의 두 얼굴간의 모핑 영역을 정할 때 사용된다. 텍스처매핑은 3D 스캐너로부터 획득한 얼굴의 기하 데이터에 세 방향의 사진 이미지를 이용하여 매핑한다. 3D 얼굴모핑은 얼굴 특징점 입력 도구로부터 얻은 특징점을 중심으로 얼굴 영역을 분류하여 임의의 두 얼굴 간의 영역간 매핑을 실현한다. 본 시스템은 사용자가 별도의 프로그래밍 작업 없이 대화형 인터페이스에서 3D 스캐너에서 획득한 얼굴 메쉬 데이터를 이용하여 사진 이미지로 텍스처 매핑을 실행하여 사실적인 3D 얼굴 모델을 얻을 수 있고, 임의의 서로 다른 얼굴 모델들간의 모핑 애니메이션을 쉽게 실현할 수가 있다.

3차원 얼굴 모델링과 예측 시스템 (A Three-Dimensional Facial Modeling and Prediction System)

  • 구본관;정철희;조선영;이명원
    • 한국컴퓨터그래픽스학회논문지
    • /
    • 제17권1호
    • /
    • pp.9-16
    • /
    • 2011
  • 본논문에서는 3차원 3D 얼굴 스캔 데이터와 사진 이미지를 이용하여 3D 얼굴 모델을 생성하고 향후의 얼굴을 예측하는 시스템 개발에 대해 기술한다. 본 시스템은 3차원 텍스처매핑, 얼굴 정의 파라미터 입력 도구, 3차원 예측 알고리즘으로 구성 되어 있다. 3차원 텍스처매핑 기능에서는 3D 스캐너로 획득한 얼굴 모델과 사진 이미지를 이용하여 특정 연령에서의 새로운 얼굴모델을 생성한다. 텍스처매핑은 3D 스캐너로부터 획득한 메쉬 데이터에 정면과 좌우 측면의 세 방향의 사진 이미지를 이용하여 매핑하였다. 얼굴 정의 파라미터 입력도구는 3차원 텍스처매핑에 필요한 사용자 인터페이스 도구로서, 얼굴 모델의 정확한 재질값을 얼굴 사진으로부터 얻기 워하여 사진과 3D 얼굴 모델의 특징점을 일치시키는데 사용된다. 본 연구에서는 한 얼굴의 향후 연령대에서의 얼굴 모델을 구하기 위하여 100여개의 얼굴 스캔 데이터베이스를 이용한 통계적 분석에 의해 재질값을 예측 계산하여 해상도 높은 재질값을 가지는 모든 연령대의 3D 얼굴모델을 구성하였다.

Can a spontaneous smile invalidate facial identification by photo-anthropometry?

  • Pinto, Paulo Henrique Viana;Rodrigues, Caio Henrique Pinke;Rozatto, Juliana Rodrigues;da Silva, Ana Maria Bettoni Rodrigues;Bruni, Aline Thais;da Silva, Marco Antonio Moreira Rodrigues;da Silva, Ricardo Henrique Alves
    • Imaging Science in Dentistry
    • /
    • 제51권3호
    • /
    • pp.279-290
    • /
    • 2021
  • Purpose: Using images in the facial image comparison process poses a challenge for forensic experts due to limitations such as the presence of facial expressions. The aims of this study were to analyze how morphometric changes in the face during a spontaneous smile influence the facial image comparison process and to evaluate the reproducibility of measurements obtained by digital stereophotogrammetry in these situations. Materials and Methods: Three examiners used digital stereophotogrammetry to obtain 3-dimensional images of the faces of 10 female participants(aged between 23 and 45 years). Photographs of the participants' faces were captured with their faces at rest (group 1) and with a spontaneous smile (group 2), resulting in a total of 60 3-dimensional images. The digital stereophotogrammetry device obtained the images with a 3.5-ms capture time, which prevented undesirable movements of the participants. Linear measurements between facial landmarks were made, in units of millimeters, and the data were subjected to multivariate and univariate statistical analyses using Pirouette® version 4.5 (InfoMetrix Inc., Woodinville, WA, USA) and Microsoft Excel® (Microsoft Corp., Redmond, WA, USA), respectively. Results: The measurements that most strongly influenced the separation of the groups were related to the labial/buccal region. In general, the data showed low standard deviations, which differed by less than 10% from the measured mean values, demonstrating that the digital stereophotogrammetry technique was reproducible. Conclusion: The impact of spontaneous smiles on the facial image comparison process should be considered, and digital stereophotogrammetry provided good reproducibility.

Accuracy and precision of integumental linear dimensions in a three-dimensional facial imaging system

  • Kim, Soo-Hwan;Jung, Woo-Young;Seo, Yu-Jin;Kim, Kyung-A;Park, Ki-Ho;Park, Young-Guk
    • 대한치과교정학회지
    • /
    • 제45권3호
    • /
    • pp.105-112
    • /
    • 2015
  • Objective: A recently developed facial scanning method uses three-dimensional (3D) surface imaging with a light-emitting diode. Such scanning enables surface data to be captured in high-resolution color and at relatively fast speeds. The purpose of this study was to evaluate the accuracy and precision of 3D images obtained using the Morpheus 3D$^{(R)}$ scanner (Morpheus Co., Seoul, Korea). Methods: The sample comprised 30 subjects aged 24.34 years (mean $29.0{\pm}2.5$ years). To test the correlation between direct and 3D image measurements, 21 landmarks were labeled on the face of each subject. Sixteen direct measurements were obtained twice using digital calipers; the same measurements were then made on two sets of 3D facial images. The mean values of measurements obtained from both methods were compared. To investigate the precision, a comparison was made between two sets of measurements taken with each method. Results: When comparing the variables from both methods, five of the 16 possible anthropometric variables were found to be significantly different. However, in 12 of the 16 cases, the mean difference was under 1 mm. The average value of the differences for all variables was 0.75 mm. Precision was high in both methods, with error magnitudes under 0.5 mm. Conclusions: 3D scanning images have high levels of precision and fairly good congruence with traditional anthropometry methods, with mean differences of less than 1 mm. 3D surface imaging using the Morpheus 3D$^{(R)}$ scanner is therefore a clinically acceptable method of recording facial integumental data.

Linear accuracy of cone-beam computed tomography and a 3-dimensional facial scanning system: An anthropomorphic phantom study

  • Oh, Song Hee;Kang, Ju Hee;Seo, Yu-Kyeong;Lee, Sae Rom;Choi, Hwa-Young;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • 제48권2호
    • /
    • pp.111-119
    • /
    • 2018
  • Purpose: This study was conducted to evaluate the accuracy of linear measurements of 3-dimensional (3D) images generated by cone-beam computed tomography (CBCT) and facial scanning systems, and to assess the effect of scanning parameters, such as CBCT exposure settings, on image quality. Materials and Methods: CBCT and facial scanning images of an anthropomorphic phantom showing 13 soft-tissue anatomical landmarks were used in the study. The distances between the anatomical landmarks on the phantom were measured to obtain a reference for evaluating the accuracy of the 3D facial soft-tissue images. The distances between the 3D image landmarks were measured using a 3D distance measurement tool. The effect of scanning parameters on CBCT image quality was evaluated by visually comparing images acquired under different exposure conditions, but at a constant threshold. Results: Comparison of the repeated direct phantom and image-based measurements revealed good reproducibility. There were no significant differences between the direct phantom and image-based measurements of the CBCT surface volume-rendered images. Five of the 15 measurements of the 3D facial scans were found to be significantly different from their corresponding direct phantom measurements(P<.05). The quality of the CBCT surface volume-rendered images acquired at a constant threshold varied across different exposure conditions. Conclusion: These results proved that existing 3D imaging techniques were satisfactorily accurate for clinical applications, and that optimizing the variables that affected image quality, such as the exposure parameters, was critical for image acquisition.