• 제목/요약/키워드: Three-dimensional automatic measurement

검색결과 33건 처리시간 0.028초

3차원 안면자동인식기의 Positioning 오차분석 (An Positioning Error Analysis of 3D Face Recognition Apparatus)

  • 곽창규;조용범;손은혜;유정희;고병희;김종원;김규곤;이의주
    • 사상체질의학회지
    • /
    • 제18권2호
    • /
    • pp.34-40
    • /
    • 2006
  • 1. Objectives We are going to develope 3D Face Recognition Apparatus to analyse the facial characteristics of the Sasangin. In the process, we should identify the recognition rate of the three dimensional position using this Apparatus. 2. Methods We took a photograph of calibrator($280{\times}400mm$) with interval of 20mm longitudinal direction of 10 times using 3D Face Recognition Apparatus. In the practice, we obtained 967 point to the exclusion of points deviating from the visual field of dual camera. And we made a comparison between measurement values and three dimensional standard values to calculate the errors. 3. Results and Conclusions In this test, the average error rate of X axis values was 0.019% and the maximum error rate of X axis values was 0.033%, the average error rate of Y axis values was 0.025% and the maximum error rate of Y axis values was 0.044%, the average error rate of Z axis values was 0.158% and the maximum error rate of Z axis values was 0.269%. This results exhibit much improvement upon the average error rate 1% and the maximum error rate 2.242% of the existing 3D Recognition Apparatus. In conclusion, we assessed that this apparatus was adaptable to abstract the facial characteristic point from three dimensional face shape in the mechanical aspects.

  • PDF

Three-dimensional shape measurement using grating patterns form an optical spatial modulator

  • Tsujioka, Katsumi;Ito, Hiroshi;Furuhashi, Hideo;Higa, Shuntaro;Hayashi, Niichi;Yamada, Jun;Hatano, Kazuo;Uchida, Yoshiyuki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1994년도 Proceedings of the Korea Automatic Control Conference, 9th (KACC) ; Taejeon, Korea; 17-20 Oct. 1994
    • /
    • pp.561-565
    • /
    • 1994
  • An automatic measuring system of three dimensional shape by a projection method with grating pattern from in optical spatial modulator has been developed. The characteristics of the system were studied. This system is composed of a projector, an optical spatial modulator, a CCD camera, and computer. A liquid crystal is used as the optical spatial modulator. The grating patterns that ire projected on the surface of the object are controlled by the computer connected with the optical spatial modulator. The projector patterns are measured by the CCD camera. The data are transferred to the computer. After a transformation into line data, the data are analyzed to obtain the coordinate of the surface of the object. This system has advantages as follows. (1) It is possible to capture the surface topography without any contact. (2) The time required for the measurements is shorter than the light-section method. (3) An optical spatial modulator using a liquid crystal is possible to control the grating patterns accurately by a computer. Surfaces of a plate and a cylinder were measured. The threshold level had an influence on the measurement. It was shown that this system has adequae accuracy in the measurements.

  • PDF

체형별 허리 다트량을 활용한 플리츠 스커트 원형 설계에 관한 연구 (A Study on a Pattern Design for Pleated Skirts Based on the Amount of Waist Darts by Somatotype)

  • 이정화;마루타 나오미;히로카와 타에코
    • 한국의류학회지
    • /
    • 제35권8호
    • /
    • pp.933-945
    • /
    • 2011
  • This research proposes a pattern design method for 24 pleated skirts in order to develop an automatic draft program for pleated skirts that will enhance fit and enable mass production. The research method and results are outlined as follow. 1. Three-dimensional body measurements were conducted on 30 randomly selected women in their 20s. By using 34 body measurement items and 6 types of calculations among the items, the items required in the designing of an original pleated skirt were extracted. They were then interpreted through correlation analysis, variance analysis, a t-test, linear regression analysis and multiple regression analysis. 2. An extra amount was added to the waist measurement and external capsule measurement according to the number of times the pleats coincided and the thickness of the fabric by the degree of polymerization of the horizontal cross section (the test of this research: 0.518mm). The extra amount of waist measurement was 3.6cm while the hip measurement was 4.3cm larger than the hip measurement combined with the external capsule measurement and the extra amount. 3. Based on the ${\pm}$standard deviation/2 as the average of the difference between the external capsule measurement and waist measurement, the subjects were classified into 3 somatotypes. Somatotype 1 presented an average total length of waist darts of 23.6cm while that of somatotype 2 was 26.2cm and that of somatotype 3 was 30.2cm. It has been confirmed that there is a significant difference among somatotypes in the total length of waist darts from the front center to the front side and the total length of waist darts from the side to the back center in terms of the average amount of waist darts for every 12 parts on the WL.

밸브 수압측정기의 유동해석 (Computational Fluid Dynamics of Hydraulic Valve Meter)

  • 이종선
    • 한국산학기술학회논문지
    • /
    • 제13권5호
    • /
    • pp.1963-1968
    • /
    • 2012
  • 본 논문은 현장에서 사용하고 있는 밸브 수압측정기를 3차원 자동설계 프로그램인 CATiA를 활용하여 설계하였다. 또한 유한요소 해석코드인 ANSYS를 활용하여 설계된 밸브 수압측정기에 대하여 유동해석을 수행하여 내부압력에 따른 유체의 흐름을 구하였다. 이러한 해석결과는 새로운 밸브 수압측정기를 개발하는데 기초자료로 활용될 계획이며 개발예정인 밸브 수압측정기는 밸브 점검 시 시간을 단축하고, 사고를 방지하여 안전성을 향상시킨다.

USING WEB CAMERA TECHNOLOGY TO MONITOR STEEL CONSTRUCTION

  • Kerry T. Slattery;Amit Kharbanda
    • 국제학술발표논문집
    • /
    • The 1th International Conference on Construction Engineering and Project Management
    • /
    • pp.841-844
    • /
    • 2005
  • Computer vision technology can be used to interpret the images captured by web cameras installed on construction sites to automatically quantify the results. This information can be used for quality control, productivity measurement and to direct construction. Steel frame construction is particularly well suited for automatic monitoring as all structural members can be viewed from a small number of camera locations, and three-dimensional computer models of steel structures are frequently available in a standard electronic format. A system is being developed that interprets the 3-D model and directs a camera to look for individual members as regular intervals to determine when each is in place and report the results. Results from a simple lab-scale system are presented along with preliminary full-scale development.

  • PDF

입자 홀로그래피에서 입자의 광축 방향 위치 특성에 관한 연구 (The Characteristics of the Particle Position Along an Optical Axis in Particle Holography)

  • 추연준;강보선
    • 대한기계학회논문집B
    • /
    • 제30권4호
    • /
    • pp.287-297
    • /
    • 2006
  • The Holographic Particle Velocimetry system can be a promising optical tool for the measurements of three dimensional particle velocities. One of inherent limitations of particle holography is the very long depth of field of particle images, which causes considerable difficulty in the determination of particle positions in the optical axis. In this study, we introduced three auto-focusing parameters corresponding to the size of particles, namely, Correlation Coefficient, Sharpness Index, and Depth Intensity to determine the focal plane of a particle along the optical axis. To investigate the suitability of the above parameters, the plane image of dot array screens containing different size of dots was recorded by diffused illumination holography and the positions of each dot in the optical axis were evaluated. In addition, the effect of particle position from the holographic film was examined by changing the distance of the screen from the holographic film. All measurement results verified that the evaluated positions using suggested auto-focusing parameters remain within acceptable range of errors. These research results may provide fundamental information for the development of the holographic velocimetry system based on the automatic image processing.

터널 시공 및 유지관리 단계 내공변위 계측시스템 적용사례 연구 (Case Studies on Applications of Convergence Measurement Systems at the Stages of Tunnel Construction and Maintenance)

  • 이대혁;한일영;김기선;진석우
    • 한국터널지하공간학회 논문집
    • /
    • 제2권3호
    • /
    • pp.59-69
    • /
    • 2000
  • 3차원 광파기 계측장비와 당사에서 개발한 핵심부품인 Target Pin 및 자료처리 분석프로그램 TEMS3D을 통합한 3차원 광파기 계측시스템을 구축하여 터널의 시공중 내공변위 및 천단침하를 계측하였다. 적용결과 천단침하 계측 및 전방지반 예측 측면에서 시스템의 효용성을 검증하였다. 터널의 유지관리 단계의 내공변위 계측을 위해 DOCS시스템을 지하철 단면에 적용하여 계측치의 진동, 시스템의 검증, 열차 운행, 터널내 온도변화 및 고전압에 의한 영향을 검토하여 향후 유지관리 방안을 제시하였다.

  • PDF

프로그레시브 금형의 품질관리를 위한 정도관리 시스템 개발 (Development of a Precision Management System for Quality Control of Progressive die)

  • 박종남
    • 한국산학기술학회논문지
    • /
    • 제15권9호
    • /
    • pp.5434-5439
    • /
    • 2014
  • 금속의 표면관리는 공구 현미경이나 표면 조도 측정기를 이용하고 있다. 이러한 방법은 구조적인 문제로 인하여 생산현장에서 금형의 표면 상태 확인을 하기에는 효율성이 떨어진다. 이런 이유로 완성된 금형의 노후화에 따른 마모, 흠집 및 표면 상태를 관리할 수 있는 분석시스템 또는 측정시스템이 필요하다. 본 연구는 금형이나 가공품의 자동분석 및 기준화를 위한 표면상태 분석 소프트웨어를 개발하였다. 소프트웨어는 기본적으로 원, 점, 선 등의 요소들을 측정할 수 있게 개발하였으며, 캡처한 사진을 3차원 이미지로 구현하여 금형에 생긴 홈의 깊이와 단면 프로파일을 추정할 수 있도록 중점을 두었다. 실험분석결과 표면 조도는 93.2%이상의 정확도를 나타냈으며, 조명밝기에 대한 표면 조도의 최대편차는 $3{\mu}m$ 이내로 매우 정밀하였다. 이런 결과로 금형의 측정 및 표면분석을 통한 품질관리의 효율성을 확인 할 수 있었다.

HPLC법을 이용한 HbA1c 측정시 Abnormal Peak의 빈도와 원인 (Factors Influencing Frequency of Abnormal Peak in the Measurement of HbA1c by HPLC)

  • 김선경;배애영;최대용;김명수;유광현;기창석
    • 대한임상검사과학회지
    • /
    • 제37권2호
    • /
    • pp.71-77
    • /
    • 2005
  • We experienced the specimen that contains a hemoglobin variant known as interference from HbAS in October 2003. It was the first case of Hb variants since Samsung Medical Center began conducting glycohemoglobin College of American Pathologists surveys in 1997. The purpose of this study is to share our experience with the specimen and promote the understanding of Hb variants & derivatives. We've performed cross checks to examine HbA1c by using two pieces of equipment; the TOSHOH G7 and BIO-RAD VARIANT-T(turbo), and Automatic High Performance Liquid Chromatography(HPLC) as an analytic measurement method. HPLC provides different fractional information of hemoglobin with a two-dimensional graph as well as numeric results. We have been performing a "Systematic Checking Process". Three specimen suspicious of Hb variants & derivatives were found through this process. College of American Pathologists notified that it is important for users to be aware of the limitation of their glycohemoglobin method to avoid reporting incorrect results due to interference from hemoglobin variants or hemoglobin adducts. Therefore, laboratory findings of Hb variants & derivatives are very important. The experience of qualified technicians with professional knowledge in Hb variants is the most important aspect in finding Hb variants. Korea is homogeneous in race and is not in an area with a higher finding rate of Hb variants. While 1,024 cases of Hb variants have been found in Japan, we do not have specific data on how many cases of Hb variants have been found in Korea. Considering Hb variant cases in Japan, which is geographically close to us, it is presumed that there must be various Hb variant cases in Korea. If domestic laboratories set a systemic protocol and build a network to share our experience in Hb variants, I expect the Korean Hb variants could also be listed on the world's Hb variant list.

  • PDF

다중시기 항공 LiDAR를 활용한 도시림 개체목 수고생장분석 (Analysis of the Individual Tree Growth for Urban Forest using Multi-temporal airborne LiDAR dataset)

  • 김성열;김휘문;송원경;최영은;최재용;문건수
    • 한국환경복원기술학회지
    • /
    • 제22권5호
    • /
    • pp.1-12
    • /
    • 2019
  • It is important to measure the height of trees as an essential element for assessing the forest health in urban areas. Therefore, an automated method that can measure the height of individual tree as a three-dimensional forest information is needed in an extensive and dense forest. Since airborne LiDAR dataset is easy to analyze the tree height(z-coordinate) of forests, studies on individual tree height measurement could be performed as an assessment forest health. Especially in urban forests, that adversely affected by habitat fragmentation and isolation. So this study was analyzed to measure the height of individual trees for assessing the urban forests health, Furthermore to identify environmental factors that affect forest growth. The survey was conducted in the Mt. Bongseo located in Seobuk-gu. Cheonan-si(Middle Chungcheong Province). We segment the individual trees on coniferous by automatic method using the airborne LiDAR dataset of the two periods (year of 2016 and 2017) and to find out individual tree growth. Segmentation of individual trees was performed by using the watershed algorithm and the local maximum, and the tree growth was determined by the difference of the tree height according to the two periods. After we clarify the relationship between the environmental factors affecting the tree growth. The tree growth of Mt. Bongseo was about 20cm for a year, and it was analyzed to be lower than 23.9cm/year of the growth of the dominant species, Pinus rigida. This may have an adverse effect on the growth of isolated urban forests. It also determined different trees growth according to age, diameter and density class in the stock map, effective soil depth and drainage grade in the soil map. There was a statistically significant positive correlation between the distance to the road and the solar radiation as an environmental factor affecting the tree growth. Since there is less correlation, it is necessary to determine other influencing factors affecting tree growth in urban forests besides anthropogenic influences. This study is the first data for the analysis of segmentation and the growth of the individual tree, and it can be used as a scientific data of the urban forest health assessment and management.