• 제목/요약/키워드: Three-dimensional Measurements

검색결과 698건 처리시간 0.023초

비만관 개수로 유동 특성 연구 (A study on flow characteristics in a partially filled open channel)

  • 최중근;성재용;이명호;이석종
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2006년도 추계학술대회 논문집
    • /
    • pp.73-77
    • /
    • 2006
  • Flow rate measurement is one of the difficult problems in the industrial applications. Especially, flow rate in a partially filled pipeline is affected by many parameters such as water level, channel slop, etc. In the present study, prior to the development of a flowmeter, the flow characteristics has been investigated by particle image velocimetry (PIV) measurements. Three-dimensional velocity distributions were obtained from sectional measurements of velocity profiles according to the water level. As a result, it is found that there is no similarity in the velocity profile when the lateral position is changed. In addition, the maximum velocity does not always occur on the free surface. It depends on the water level. In the aspect of flow rate measurement, the previous calculus based upon point measurement techniques is proved to be inaccurate because of the lack of whole flow information.

  • PDF

CONTINUOUS DATA ASSIMILATION FOR THE THREE-DIMENSIONAL LERAY-α MODEL WITH STOCHASTICALLY NOISY DATA

  • Bui Kim, My;Tran Quoc, Tuan
    • 대한수학회보
    • /
    • 제60권1호
    • /
    • pp.93-111
    • /
    • 2023
  • In this paper we study a nudging continuous data assimilation algorithm for the three-dimensional Leray-α model, where measurement errors are represented by stochastic noise. First, we show that the stochastic data assimilation equations are well-posed. Then we provide explicit conditions on the observation density (resolution) and the relaxation (nudging) parameter which guarantee explicit asymptotic bounds, as the time tends to infinity, on the error between the approximate solution and the actual solution which is corresponding to these measurements, in terms of the variance of the noise in the measurements.

LiDAR Measurement Analysis in Range Domain

  • Sooyong Lee
    • 센서학회지
    • /
    • 제33권4호
    • /
    • pp.187-195
    • /
    • 2024
  • Light detection and ranging (LiDAR), a widely used sensor in mobile robots and autonomous vehicles, has its most important function as measuring the range of objects in three-dimensional space and generating point clouds. These point clouds consist of the coordinates of each reflection point and can be used for various tasks, such as obstacle detection and environment recognition. However, several processing steps are required, such as three-dimensional modeling, mesh generation, and rendering. Efficient data processing is crucial because LiDAR provides a large number of real-time measurements with high sampling frequencies. Despite the rapid development of controller computational power, simplifying the computational algorithm is still necessary. This paper presents a method for estimating the presence of curbs, humps, and ground tilt using range measurements from a single horizontal or vertical scan instead of point clouds. These features can be obtained by data segmentation based on linearization. The effectiveness of the proposed algorithm was verified by experiments in various environments.

Comparison of cone-beam computed tomography cephalometric measurements using a midsagittal projection and conventional two-dimensional cephalometric measurements

  • Jung, Pil-Kyo;Lee, Gung-Chol;Moon, Cheol-Hyun
    • 대한치과교정학회지
    • /
    • 제45권6호
    • /
    • pp.282-288
    • /
    • 2015
  • Objective: This study investigated whether it is possible to use a two-dimensional (2D) standard in three-dimensional (3D) analysis, by comparing the angles and lengths measured from a midsagittal projection in 3D cone-beam computed tomography (CBCT) with those measured by 2D lateral cephalometric radiography (LCR). Methods: Fifty patients who underwent both LCR and CBCT were selected as subjects. CBCT was reoriented in 3 different methods and the measuring-points were projected onto the midsagittal plane. Twelve angle values and 8 length values were measured on both LCR and CBCT and compared. Results: Repeated measures analysis of the variance revealed statistically significant differences in 7 angular and 5 linear measurements among LCR and 3 types of CBCT (p < 0.05). Of these 12 measurements, multiple comparisons showed that 6 measurements (ANB, AB to FH, IMPA, FMA, Co-Gn, Go-Me) were not significantly different in pairwise comparisons. LCR was significantly different from 3 types of CBCT in 3 angular (SN to FH, interincisal angle, FMIA) and 2 linear (S-Go, Co-ANS) measurements. The CBCT method was similar for all measurements, except for 1 linear measurement, i.e., S-N. However, the disparity between the mean values for all parameters was within the range of clinical measurement error. Conclusions: 3D-CBCT analysis, using midsagittal projection, is a useful method in which the 2D-LCR normative values can be used. Although the measurements changed with reorientation, these changes were not clinically significant.

Technical Performance of Two-Dimensional Shear Wave Elastography for Measuring Liver Stiffness: A Systematic Review and Meta-Analysis

  • Dong Wook Kim;Chong Hyun Suh;Kyung Won Kim;Junhee Pyo;Chan Park;Seung Chai Jung
    • Korean Journal of Radiology
    • /
    • 제20권6호
    • /
    • pp.880-893
    • /
    • 2019
  • Objective: To assess the technical performance of two-dimensional shear wave elastography (2D-SWE) for measuring liver stiffness. Materials and Methods: The Ovid-MEDLINE and EMBASE databases were searched for studies reporting the technical performance of 2D-SWE, including concerns with technical failures, unreliable measurements, interobserver reliability, and/or intraobserver reliability, published until June 30, 2018. The pooled proportion of technical failure and unreliable measurements was calculated using meta-analytic pooling via the random-effects model and inverse variance method for calculating weights. Subgroup analyses were performed to explore potential causes of heterogeneity. The pooled intraclass correlation coefficients (ICCs) for interobserver and intraobserver reliability were calculated using the Hedges-Olkin method with Fisher's Z transformation of the correlation coefficient. Results: The search yielded 34 articles. From 20 2D-SWE studies including 6196 patients, the pooled proportion of technical failure was 2.3% (95% confidence interval [CI], 1.3-3.9%). The pooled proportion of unreliable measurements from 20 studies including 6961 patients was 7.5% (95% CI, 4.7-11.7%). In the subgroup analyses, studies conducting more than three measurements showed fewer unreliable measurements than did those with three measurements or less, but no intergroup difference was found in technical failure. The pooled ICCs for interobserver reliability (from 10 studies including 517 patients) and intraobserver reliability (from 7 studies including 679 patients) were 0.87 (95% CI, 0.82-0.90) and 0.93 (95% CI, 0.89-0.95), respectively, suggesting good to excellent reliability. Conclusion: 2D-SWE shows good technical performance for assessing liver stiffness, with high technical success and reliability. Future studies should establish the quality criteria and optimal number of measurements.

Three-dimensional morphological evaluation of the hard palate in Korean adults with mild-to-moderate obstructive sleep apnea

  • Yu, Chen;Ahn, Hyo-Won;Kim, Seong-Hun
    • 대한치과교정학회지
    • /
    • 제48권3호
    • /
    • pp.133-142
    • /
    • 2018
  • Objective: The purpose of this study was to evaluate differences in three-dimensional (3D) morphology of the hard palate between Korean adults with and without mild-to-moderate obstructive sleep apnea (OSA) using cone-beam computed tomographic (CBCT) data. Methods: The protocol for the two-dimensional (2D) and 3D mathematical modeling was established by analyzing CBCT images of 30 adults with OSA and 30 matched controls without OSA, using MIMICS software. The linear and angular measurements were also determined using this software. The measurements were repeated for 30 palates, by the same operator, to assess reliability. Results: The palates of OSA patients were higher in the posterior part and narrower in the anterior-superior part than those of the control group (p < 0.05). The nasal cavities of patients with OSA were narrower (p < 0.05) than those of controls. The increasing angle of the first molar palatal root is a compensation of the upper dental arch to improve occlusion. However, for most palatal measurements, there were no significant differences between the OSA and control groups (p > 0.05). The results of 2D and 3D mathematical models were consistent for linear and angular measurements, indicating that 2D and 3D mathematical modeling of the palate is a reliable methodology. Conclusions: OSA is a multifactorial disease; the palates of adults with mild-to-moderate OSA do not have specific morphological features distinct from those of healthy controls.

Linear accuracy of cone-beam computed tomography and a 3-dimensional facial scanning system: An anthropomorphic phantom study

  • Oh, Song Hee;Kang, Ju Hee;Seo, Yu-Kyeong;Lee, Sae Rom;Choi, Hwa-Young;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • 제48권2호
    • /
    • pp.111-119
    • /
    • 2018
  • Purpose: This study was conducted to evaluate the accuracy of linear measurements of 3-dimensional (3D) images generated by cone-beam computed tomography (CBCT) and facial scanning systems, and to assess the effect of scanning parameters, such as CBCT exposure settings, on image quality. Materials and Methods: CBCT and facial scanning images of an anthropomorphic phantom showing 13 soft-tissue anatomical landmarks were used in the study. The distances between the anatomical landmarks on the phantom were measured to obtain a reference for evaluating the accuracy of the 3D facial soft-tissue images. The distances between the 3D image landmarks were measured using a 3D distance measurement tool. The effect of scanning parameters on CBCT image quality was evaluated by visually comparing images acquired under different exposure conditions, but at a constant threshold. Results: Comparison of the repeated direct phantom and image-based measurements revealed good reproducibility. There were no significant differences between the direct phantom and image-based measurements of the CBCT surface volume-rendered images. Five of the 15 measurements of the 3D facial scans were found to be significantly different from their corresponding direct phantom measurements(P<.05). The quality of the CBCT surface volume-rendered images acquired at a constant threshold varied across different exposure conditions. Conclusion: These results proved that existing 3D imaging techniques were satisfactorily accurate for clinical applications, and that optimizing the variables that affected image quality, such as the exposure parameters, was critical for image acquisition.

Accuracy and precision of polyurethane dental arch models fabricated using a three-dimensional subtractive rapid prototyping method with an intraoral scanning technique

  • Kim, Jae-Hong;Kim, Ki-Baek;Kim, Woong-Chul;Kim, Ji-Hwan;Kim, Hae-Young
    • 대한치과교정학회지
    • /
    • 제44권2호
    • /
    • pp.69-76
    • /
    • 2014
  • Objective: This study aimed to evaluate the accuracy and precision of polyurethane (PUT) dental arch models fabricated using a three-dimensional (3D) subtractive rapid prototyping (RP) method with an intraoral scanning technique by comparing linear measurements obtained from PUT models and conventional plaster models. Methods: Ten plaster models were duplicated using a selected standard master model and conventional impression, and 10 PUT models were duplicated using the 3D subtractive RP technique with an oral scanner. Six linear measurements were evaluated in terms of x, y, and z-axes using a non-contact white light scanner. Accuracy was assessed using mean differences between two measurements, and precision was examined using four quantitative methods and the Bland-Altman graphical method. Repeatability was evaluated in terms of intra-examiner variability, and reproducibility was assessed in terms of interexaminer and inter-method variability. Results: The mean difference between plaster models and PUT models ranged from 0.07 mm to 0.33 mm. Relative measurement errors ranged from 2.2% to 7.6% and intraclass correlation coefficients ranged from 0.93 to 0.96, when comparing plaster models and PUT models. The Bland-Altman plot showed good agreement. Conclusions: The accuracy and precision of PUT dental models for evaluating the performance of oral scanner and subtractive RP technology was acceptable. Because of the recent improvements in block material and computerized numeric control milling machines, the subtractive RP method may be a good choice for dental arch models.

에어 스포일러 장착에 따른 자동차 후류 3차원 와 구조의 변화 (A Change of Three-Dimensional Vortical Structures by an Air Spoiler in the Wake of a Road Vehicle)

  • 김진석;성재용;김성초;김정수
    • 한국가시화정보학회지
    • /
    • 제4권1호
    • /
    • pp.56-61
    • /
    • 2006
  • A change of three-dimensional vortical structures on the wake behind a road vehicle has been investigated according to the existence of an air spoiler. To reconstruct the three-dimensional velocity fields, two-dimensional PIV(particle image velocimetry) measurements were performed for lots of the x-y, y-z and z-x planes. Since the isovorticity surface does not represent exactly the vortical structures within the recirculation region due to strong shear flows, the velocity component normal to the x-y plane is obtained by interpolating those velocities in the z-x plane. Then, the ${\lambda}_2-definition$ is applied to visualize the vortices in the recirculation region. As a result, it is found that the air spoiler weakens C-pillar vortices and produces strong wing-tip vortices. Inside the recirculation region, the height and volume of coherent vortices are increased relatively when an air spoiler is equipped. On the other hand, two small coherent vortices are observed in case that an air spoiler is absent.

  • PDF

Three-dimensional changes in lip vermilion morphology of adult female patients after extraction and non-extraction orthodontic treatment

  • Liu, Zhi-Yu;Yu, Jie;Dai, Fan-Fan;Jiang, Ruo-Ping;Xu, Tian-Min
    • 대한치과교정학회지
    • /
    • 제49권4호
    • /
    • pp.222-234
    • /
    • 2019
  • Objective: To investigate the three-dimensional lip vermilion changes after extraction and non-extraction orthodontic treatment in female adult patients and explore the correlation between lip vermilion changes and incisor changes. Methods: Forty-seven young female adult patients were enrolled in this study (skeletal Class III patients were excluded), including 34 lip-protruding patients treated by extraction of four first premolars (18 patients requiring mini-implants for maximum anchorage control and 16 patients without mini-implants) and 13 patients requiring non-extraction treatment. Nine angles, seven distances, and the surface area of the lip vermilion were measured by using pre- and post-treatment three-dimensional facial scans. Linear and angular measurements of incisors were performed on lateral cephalograms. Results: There were no significant changes in the vermilion measurements in the non-extraction group. The vermilion angle, vermilion height, central bow angle, height/width ratio, and vermilion surface area decreased significantly after the orthodontic treatment in the extraction groups, but the upper/lower vermilion proportion remained unchanged. Significant correlations were found between the changes in incisor position and those in vermilion angles, vermilion height, and surface area. Conclusions: Extraction of the four first premolars probably produced an aesthetic improvement in lip vermilion morphology. However, the upper/lower vermilion proportion remained unchanged. The variations in the vermilion were closely related to incisor changes, especially the upper incisor inclination changes.