• 제목/요약/키워드: Three-Dimensional Two-Phase Flow

검색결과 110건 처리시간 0.026초

단일 카메라를 이용한 이상유동 기포율 측정방법의 개발과 응용 (A Void Fraction Measurement Technique by Single Camera and Its Application)

  • 최동환;유정열;송진호;성재용
    • 대한기계학회논문집B
    • /
    • 제31권11호
    • /
    • pp.904-911
    • /
    • 2007
  • A measurement technique fur void fraction has been proposed using a time-resolved two-phase PIV system and the bubble dynamics has been investigated in gas-liquid two-phase flows. For the three-dimensional evaluation of the bubble information, both the images from the front and side views are simultaneously recorded into a high speed CCD camera by reflecting the side view image on a $45^{\circ}$ oriented mirror to be juxtaposed with the front view image. Then, a stereo-matching technique is applied to calculate the void fraction, bubble size and shape. To obtain the rising bubble velocities, the 2-frame PTV method was adopted. The present technique is applied to freely rising bubby flows in stagnant liquid. The results show that the increase of bubble flow rate gives rise to the increase of bubble size and rising velocity at first. If it goes over a certain level, the rising velocity becomes constant and the horizontal velocity grows bigger instead due to the obstruction of other bubbles.

냉각제의 분사조건 및 상변화가 혼합가스 사출시스템의 성능에 미치는 영향 (Effect of Heat Transfer and Phase Change of Coolant on the Performance of Mixed-gas Ejection System)

  • 김현묵;김정수
    • 한국추진공학회지
    • /
    • 제22권6호
    • /
    • pp.84-93
    • /
    • 2018
  • 냉각제 분사조건이 변화할 때 혼합가스 사출시스템 (또는 가스-스팀 발사체계) 냉각효율 및 발사체 사출성능의 변화를 확인하기 위해 3차원 수치모사를 수행하였다. 선행연구를 참조하여 구축한 1차원 모델을 통해 3차원 단상(single-phase) 계산모델을 검증한 후, Discrete Phase Model을 활용하여 고온의 기체에 냉각제 분사를 모사한 이상(two-phase) 유동 계산을 수행하였다. 냉각제 유량과 분사구 개수를 각각 변화시키면서 계산을 수행한 결과, 분사구 개수를 증가시켰을 경우 냉각효율이 보다 개선되었다. 또한 분사조건에 따라 냉각제 액적 서로간의 coalescence 발생 빈도 및 공간분포 변화가 발생하여 액적의 직경이 달라졌고, 이는 냉각제 증발률에 영향을 미쳤다. 냉각제의 증발은 breech 내부의 온도를 감소시키는 반면에 압력감소를 억제하여 사출시스템 최적화 설계에 있어 중요한 요소임을 확인하였다.

Mode analysis and low-order dynamic modelling of the three-dimensional turbulent flow filed around a building

  • Lei Zhou;Bingchao Zhang;K.T. Tseb
    • Wind and Structures
    • /
    • 제38권5호
    • /
    • pp.381-398
    • /
    • 2024
  • This study presents a mode analysis of 3D turbulent velocity data around a square-section building model to identify the dynamic system for Kármán-type vortex shedding. Proper orthogonal decomposition (POD) was first performed to extract the significant 3D modes. Magnitude-squared coherence was then applied to detect the phase consistency between the modes, which were roughly divided into three groups. Group 1 (modes 1-4) depicted the main vortex shedding on the wake of the building, with mode 2 being controlled by the inflow fluctuation. Group 2 exhibited complex wake vortexes and single-sided vortex phenomena, while Group 3 exhibited more complicated phenomena, including flow separation. Subsequently, a third-order polynomial regression model was used to fit the dynamics system of modes 1, 3, and 4, which revealed average trend of the state trajectory. The two limit cycles of the regression model depicted the two rotation directions of Kármán-type vortex. Furthermore, two characteristic periods were identified from the trajectory generated by the regression model, which indicates fast and slow motions of the wake vortex. This study provides valuable insights into 3D mode morphology and dynamics of Kármán-type vortex shedding that helps to improve design and efficiency of structures in turbulent flow.

비정렬 격자 기반의 결빙 액적 해석을 위한 유한체적 기법 (A THREE-DIMENSIONAL UNSTRUCTURED FINITE VOLUME METHOD FOR ANALYSIS OF DROPLET IMPINGEMENT IN ICING)

  • 정기영;정성기;명노신
    • 한국전산유체공학회지
    • /
    • 제18권2호
    • /
    • pp.41-48
    • /
    • 2013
  • Ice accretion on the solid surface is an importance factor in assessing the performance of aircraft and wind turbine blade. Changes in the external shape due to ice accretion can greatly deteriorate the aerodynamic performance. In this study, a three-dimensional upwind-type second-order positivity-preserving finite volume CFD scheme based on the unstructured mesh topology is developed to simulate two-phase flow in atmospheric icing condition. The code is then validated by comparing with NASA IRT experimental data on the sphere. The present results of the collection efficiency are found to be in close agreement with experimental data and show improvement near the stagnation region.

슬리트케이슨제에 의한 반사율과 구조물에 작용하는 파압에 관한 2차원 및 3차원해석 (Two and Three Dimensional Analysis about the Reflection Coefficient by the Slit Caisson and Resulting Wave Pressure Acting on the Structure)

  • 이광호;최현석;백동진;김도삼
    • 한국해안·해양공학회논문집
    • /
    • 제22권6호
    • /
    • pp.374-386
    • /
    • 2010
  • 최근 슬리트케이슨제와 같은 유공방파제의 파랑제어특성에 대한 이론적 실험적 연구가 활발히 진행되고 있다. 본 연구에서는 규칙파의 작용하에 슬리트케이슨에 의한 반사율의 특성과, 전면유공부 및 유수실의 내부벽면에 작용하는 파압을 2차원 및 3차원수치파동수로에서 각각 추정하고, 그 결과를 검토하였다. 수치실험에서는 주기 7초, 9초, 11초 및 13초와 각각의 주기에 대해 파형경사 0.02, 0.03 및 0.04를 갖는 입사파고의 수치실험안을 설정하였고, 본 연구에서 사용된 2차원 및 3차원의 수치해석은 Navier-Stokes운동방정식에 기초한 이상류(이상류(二相流)) 수치 모델로서, 이는 타해석기법에 비해 복잡한 수면변동에 대한 물리현상을 쉽게 재현할 수 있으며, 수치프로그램의 구성이 보다 간략하게 되는 장점이 있다. 실험결과에 의하면, 반사율에 있어서 주기가 짧은 경우에는 2차원해석이 상당히 큰 값을 나타내지만, 주기가 길어지고 파형경사가 큰 경우에는 2차원해석과 3차원해석의 결과가 거의 동일한 값을 나타낸다. 파압에 있어서 주기가 짧은 경우에는 두 해석법에서 차이는 작지만, 주기가 길어지고 파형경사가 큰 경우에는 차이가 크게 나타나는 경향을 확인할 수 있었다.

상변화 물질을 이용한 이동전화기의 냉각에 관한 연구 (A Study of Cooling of Mobile Phone Using PCM Module)

  • 이상진;정수진;김우승
    • 대한기계학회논문집B
    • /
    • 제29권11호
    • /
    • pp.1173-1181
    • /
    • 2005
  • The cooling effect of a mobile phone using PCM(Phase Change Material) module has been numerically investigated. A transient three-dimensional numerical analysis of heat and fluid flow with natural convection is performed in this study. Governing conservation equations for mass, momentum and energy are solved by an implicit finite volume method. An enthalpy-porosity technique has been used for modeling of the melting process. Two different ways of placing the PCM module are considered. One is to place a PCM module between the substrate and battery pack, and the other is to place a PCM module between MCM(multichip module) and battery pack. Three different types of PCMs are used to predict the performance of PCM. The results show that passive cooling with PCM can reduce the temperature rise and the effect of natural convection in PCM module considered in this study is negligible.

2상 유동 해석코드 CUPID를 이용한 CANDU 원자로 감속재 열수력 예비해석 (Preliminary Analysis of the CANDU Moderator Thermal-Hydraulics using the CUPID Code)

  • 박상기;이재룡;윤한영;김형태;정재준
    • 에너지공학
    • /
    • 제21권4호
    • /
    • pp.419-426
    • /
    • 2012
  • 본 연구에서는 기기 스케일 2상 유동(Two-phase flow) 해석 코드 CUPID를 사용하여 CANDU 원자로의 칼란드리아 용기 내부 감속재의 열수력 거동을 분석하기 위한 사전연구를 수행하였다. 먼저, Stern 연구소에서 수행한 단상유동 실험 3종류를 이용하여 CUPID 코드를 검증하였다. 칼란드리아 관다발 영역 격자생성의 복잡성을 피하기 위하여 다공성 매질 모델을 해당 영역에 적용하였고, 다공성 매질 영역의 유동 저항은 실험에서 얻은 관계식을 이용하여 계산하도록 하였다. 계산결과, CUPID 코드는 칼란드리아 용기 내부의 강제 및 자연 대류의 혼합 유동 양식을 성공적으로 예측하였다. 다음으로 2상 유동이 발생하는 경우를 해석하였다. 이들 계산을 통해 CUPID 코드의 CANDU 원자로 감속재 해석 능력을 보였다. 또한, 국부 과냉각 여유도를 예측하는데 사용할 수 있는 유입유량 대비 칼란드리아 용기의 국부 최대 감속재 온도 그래프를 제시하였다.

배플의 높이 변화에 따른 3 차원 사각 탱크 내부의 슬로싱 현상에 관한 수치적 연구 (Numerical Study on Liquid Sloshing in the Three-dimensional Rectangular Tank with Various Baffle Heights)

  • 이창열;윤현식;정재환
    • 대한조선학회논문집
    • /
    • 제47권1호
    • /
    • pp.38-46
    • /
    • 2010
  • This study aims at investigating the effect of the baffle height on the liquid sloshing in the three-dimensional (3D) rectangular tank. In order to simulate the 3D incompressible viscous two-phase flow in the 3D tank with partially filled liquid, the present study has adopted the volume of fluid (VOF) method based on the finite-volume method which has been well verified by comparing with the results of the relevant previous researches. The ratio of the baffle height ($h_B$) to filling level (h) has been changed in the range of $0{\leq}h_B/h{\leq}1.2$ to observe the effect on the impact loads on the side wall and free surface behavior. Generally, as baffle height increases, the impact pressure on the wall decreases and the deformation of free surface becomes weaker. However it seemed that a critical ratio of the baffle height existed to reveal the lowest impact pressure on the wall. Consequently, $h_B/h=0.8$ among $h_B/hs$ considered in the study showed the lowest impact pressure.

챔퍼가 3차원 사각 탱크 내부의 액체 슬로싱에 미치는 영향 (Effect of Chamfering Top Corners on Liquid Sloshing in the Three-dimensional Rectangular Tank)

  • 정재환;이창열;윤현식
    • 대한조선학회논문집
    • /
    • 제47권4호
    • /
    • pp.508-516
    • /
    • 2010
  • This study aims at investigating the effect of the chamfer on the liquid sloshing in the three-dimensional (3D) rectangular tank. In order to simulate the 3D incompressible viscous two-phase flow in the 3D tank with partially filled liquid, the present study has adopted the volume of fluid (VOF) method based on the finitevolume method which has been well verified by comparing with the results of the relevant previous researches. The effects of the chamfering top corners of the tank on the liquid sloshing characteristics have been investigated. The angle of the chamfering top corners (${\theta}$) has been changed in the range of $0^{\circ}{\leq}{\theta}{\leq}60^{\circ}$(${\Delta}{\theta}=15^{\circ}$) to observe the free surface behavior, and the effect on wall impact load. Generally, as the angle of the chamfering top corners increases, the impact pressure on the upper knuckle point decreases. However it seemed that a critical angle of the chamfering top corners exists to reveal the lowest impact pressure on the wall.

유한요소법을 이용한 level set 공식화의 해석 (FINITE ELEMENT ANALYSIS OF LEVEL SET FORMULATION)

  • 최형권
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2009년 추계학술대회논문집
    • /
    • pp.223-227
    • /
    • 2009
  • In the present study, a least square weighted residual method and Taylor-Galerkin method were formulated and tested for the discretization of the two hyperbolic type equations of level set method; advection and reinitialization equations. The two approaches were compared by solving a time reversed vortex flow and three-dimensional broken dam flow by employing a four-step splitting finite element method for the solution of the incompressible Navier-Stokes equations. From the numerical experiments, it was shown that the least square method is more accurate and conservative than Taylor-Galerkin method and both methods are approximately first order accurate when both advection and reinitialization phase are involved in the evolution of free surface.

  • PDF