• 제목/요약/키워드: Three phase Current Unbalance

검색결과 77건 처리시간 0.028초

교류전기철도 불평형 전력 개선을 위한 전력보상장치 제어 (Power Compensator Control for Improving Unbalanced Power of AC Electric Railway)

  • 우제훈;조종민;이태훈;차한주
    • 전력전자학회논문지
    • /
    • 제25권3호
    • /
    • pp.213-218
    • /
    • 2020
  • In this study, we propose a control algorithm to reduce the unbalanced characteristics of a three-phase system power caused by the unbalanced load of the AC electric railway. Then, we verify its performance through the design of a power compensator and experiments applying it. Like electric railway systems, a Scott transformer is applied, and the load and single-phase back-to-back converters are connected to the M-phase and T-phase outputs. The back-to-back converter monitors the difference in active power between the unbalanced loads in real-time and compensates for the power by using bidirectional characteristics. The active power is performed through PI control in the synchronous coordinate system, and DC link overall voltage and voltage balancing control are controlled jointly by M-phase and T-phase converters to improve the responsiveness of the system. To verify the performance of the proposed power compensation device, an experiment was performed under the condition that M-phase 5 kW and T-phase 1 kW unbalanced load. As a result of the experiment, the unbalance rate of the three-phase current after the operation of the power compensator decreases by 58.66% from 65.04% to 6.38%, and the excellent performance of the power compensator proposed in this study is verified.

불평형시 반복추정기법을 이용한 배전계통 고장점 표정 알고리즘 (A fault location algorithm using iterative method at unbalance conditions for distribution feeder systems)

  • 이덕수;진보건;이승재;최면송;강상희;안복신;윤남선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.121-123
    • /
    • 2001
  • This paper presents a fault location algorithm using iterative method at unbalance condition for distribution feeder systems. Distribution feeders include single phase and three phase laterals. The proposed algorithm achieves a high accuracy by continuously updating voltage and current phasor using the phase components and admittance load model.

  • PDF

3상 시스템의 무효전력, 불평형 전류 보상 기능을 갖는 태양광 전력변환장치 설계 (Design of a Photovoltaic PCS with Compensation Control of Reactive Power and Unbalance Current in Three-phase systems)

  • 박상민;김창순;레딘브엉;박민원;유인근
    • 한국산업정보학회논문지
    • /
    • 제21권3호
    • /
    • pp.29-33
    • /
    • 2016
  • 청정에너지 발전설비의 요구가 늘면서 태양광, 풍력, 연료 전지 등의 분산전원 개발이 급속도로 증가하고 있다. 반면에 이러한 증가로 인하여 배전시스템은 복잡해지고 있으며 무효전력으로 인한 역률 저감, 불평형 부하에 의한 불평형 전류 등의 문제점을 가지고 있다. 이러한 문제점들을 해결하기 위하여 본 논문에서는 태양광용 3상 4선 타입의 전력변환장치에 무효전력, 불평형 전류를 보상하는 알고리즘을 적용하였다. 제안한 태양광 전력변환장치는 기본 출력동작 뿐만 아니라 계통 전력 품질의 저해요소들에 대해서 보상이 가능하며 PSCAD/EMTDC를 이용한 시뮬레이션을 통하여 그 성능을 검증하였다.

Design of a Cascaded H-Bridge Multilevel Inverter Based on Power Electronics Building Blocks and Control for High Performance

  • Park, Young-Min;Ryu, Han-Seong;Lee, Hyun-Won;Jung, Myung-Gil;Lee, Se-Hyun
    • Journal of Power Electronics
    • /
    • 제10권3호
    • /
    • pp.262-269
    • /
    • 2010
  • This paper proposes a practical design for a Cascaded H-Bridge Multilevel (CHBM) inverter based on Power Electronics Building Blocks (PEBB) and high performance control to improve current control and increase fault tolerance. It is shown that the expansion and modularization characteristics of the CHBM inverter are improved since the individual inverter modules operate more independently, when using the PEBB concept. It is also shown that the performance of current control can be improved with voltage delay compensation and the fault tolerance can be increased by using unbalance three-phase control. The proposed design and control methods are described in detail and the validity of the proposed system is verified experimentally in various industrial fields.

3상 4 스위치 Z-소스 PWM정류기의 출력전압과 역률에 관한 연구 (A Study On the Output Voltage and Power Factor of the Three-Phase Four Switches Z-Source PWM Rectifier)

  • 수효동;엄준현;정영국;임영철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 추계학술대회 논문집
    • /
    • pp.48-49
    • /
    • 2013
  • In this paper, the four switches three-phase Z-source rectifier is studied. The conventional three-phase four switches rectifier can only either perform buck or boost operation, distortion and unbalance of the input current are serious. Therefore, we proposed the four switches three-phase Z-source rectifier which can realize buck function simply by applying the Z-impedance network. We will verify characteristics of Z-network by the simulation and experiment.

  • PDF

DVR 기능을 갖는 3상 하이브리드형 직렬 능동전력필터 (3-Phase Hybrid Series Active Power Filter with Dynamic Voltage Restorer)

  • 한석우;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.598-602
    • /
    • 2002
  • This paper presents the 3-phase hybrid series active power filter with dynamic voltage restorer(DVR) which serve as an energy buffer and current harmonics blocking resistor connected to sensitive loads, such as, to compensate voltage dips and current harmonics in power distribution system. The DVR is to inject a dynamically controlled voltage generated by a forced commutated converter in series to the bus voltage by means of a booster transformer. The momentary amplitudes of the three injected phase voltages are controlled such as to eliminate any detrimental effects of a bus fault to the load voltage. The proposed system is able to simultaneously compensate current harmonics, voltage fluctuating and voltage unbalance in power distribution systems. The reference phase angle detected by synchronized with the positive sequence component of the unbalanced source by using symmetrical component transformation. The effectiveness of proposed system is verified by the computer simulation.

  • PDF

계통연계 인버터의 주요 부하 불평형 시 상전류 제어를 통한 부하 상전압 평형 제어 (An Output Voltage Balance Control of Grid Connected Inverter by Phase Current Control at Critical Load Unbalanced Condition)

  • 박태현;김학원;조관열;민준기;최원일
    • 전력전자학회논문지
    • /
    • 제28권1호
    • /
    • pp.22-29
    • /
    • 2023
  • A grid-connected inverter can be used in grid-connected or stand-alone modes. Generally, a grid-connected inverter operates in a grid-connected mode, but the inverter operates in stand-alone mode if grid faults occur. In the stand-alone mode, the grid-connected inverter must supply electric power to a critical load that needs to receive stable power even though grid faults occur. Generally, three-phase loads are used as critical loads, but a single phase is configured in some cases. In these conditions, the critical load is required to unbalance the load power consumption, which makes the three-phase load voltage unbalancd. This unbalanced voltage problem can cause fatal problems to the three-phase critical loads, and thus must be addressed. Hence, this paper proposes an algorithm to solve this unbalanced voltage problem by the individual phase current control. The proposed method is verified using Psim simulation and experiments.

삼상 중성점 전압을 이용한 전압불평형 사고 방지용 보호장치 개발 (Development of Protection Device for Voltage Unbalance Faults using Three-Phase Neutral Voltage)

  • 곽동걸;김대석;김진환;김수창;정원석;손재현
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.621-622
    • /
    • 2012
  • The thermal over-current relay or electronic motor protection relay is mostly used as the open-phase detection device of the three-phase motor or load. When the over-current or overheat of electric line is generated, it detects and operates circuit breaker, but there is the defect that the sensing speed is slow, the operation can be sometimes failed, and the precision is decreased. In order to improve these problems, this paper is proposed a new control circuit topology for open-phase protection using semiconductor devices. Therefore, the proposed open-phase protection device enhances the sensing speed and precision, and has the advantage of simple fitting in the three-phase motor control panel in the field, as it manufactures into small size and light weight.

  • PDF

조건부 적분기를 가지는 LQ 제어기를 이용한 3상 PWM 컨버터의 전류제어 (Current Control for Three Phase PWM Converter Using LQ Controller with Conditional Integrator)

  • 김홍성;전윤석;조영준;목형수;최규하;김한성
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.345-351
    • /
    • 1997
  • In this paper, controller for PWM converter considering unsymetrical input voltage is designed and current controller using LQ controller with conditional integrator is proposed. And the proposed current controller is compared with other current controller-predictive controller, decoupling PI controller. As simulation results, LQ controller with Conditional Integrator shows the improved performance for DC link voltage regulation through transient test of load variation. And when unsymeritrical input voltage is applied to converter with conventional current controller considering only symetrical input voltage, input current is distorted but it is showed that current controller considering unsymetrical input has robust control characteristics under phase voltage unbalance.

  • PDF

DC 오프셋 전류 주입에 의한 4-Switch 3-Phase Inverter의 커패시터 전압 불평형 보상 (Compensation of Unbalanced Capacitor Voltage for Four-switch Three-phase Inverter Using DC Offset Current Injection)

  • 박영주;손상훈;최익
    • 한국전자통신학회논문지
    • /
    • 제10권3호
    • /
    • pp.365-373
    • /
    • 2015
  • 기존 6스위치 3상 인버터(SSTPI)의 한 상을 스위치 대신 커패시터로 대체한 4스위치 3상 인버터(FSTPI)에서 양 커패시터 전압의 불평형에 의한 출력전압의 오차를 보상하는 것은 FSTPI의 성능을 결정하는 중요한 요소이다. 본 논문에서는 DC 오프셋 전류 주입에 의하여 FSTPI의 커패시터 전압 불평형을 보상하는 새로운 방법과 FSTPI에 적용할 수 있는 간략화된 SVPWM 방법을 제안한다. 제안된 방법은 컴퓨터 시뮬레이션을 통해 타당성을 검증하였다.