• Title/Summary/Keyword: Three dimensional images

Search Result 1,309, Processing Time 0.026 seconds

Comparative Analysis of Surgical Outcomes of C1-2 Fusion Spine Surgery between Intraoperative Computed Tomography Image Based Navigation-Guided Operation and Fluoroscopy-Guided Operation

  • Lee, Jun Seok;Son, Dong Wuk;Lee, Su Hun;Ki, Sung Soon;Lee, Sang Weon;Song, Geun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.2
    • /
    • pp.237-247
    • /
    • 2020
  • Objective : Fixation of the C1-2 segment is challenging because of the complex anatomy in the region and the need for a high degree of accuracy to avoid complications. Preoperative 3D-computed tomography (CT) scans can help reduce the risk of complications in the vertebral artery, spinal cord, and nerve roots. However, the patient may be susceptible to injury if the patient's anatomy does not match the preoperative CT scans. The intraoperative 3D image-based navigation systems have reduced complications in instrument-assisted techniques due to greater accuracy. This study aimed to compare the radiologic outcomes of C1-2 fusion surgery between intraoperative CT image-guided operation and fluoroscopy-guided operation. Methods : We retrospectively reviewed the radiologic images of 34 patients who underwent C1-2 fusion spine surgery from January 2009 to November 2018 at our hospital. We assessed 17 cases each of degenerative cervical disease and trauma in a study population of 18 males and 16 females. The mean age was 54.8 years. A total of 139 screws were used and the surgical procedures included 68 screws in the C1 lateral mass, 58 screws in C2 pedicle, nine screws in C2 lamina and C2 pars screws, four lateral mass screws in sub-axial level. Of the 34 patients, 19 patients underwent screw insertion using intraoperative mobile CT. Other patients underwent atlantoaxial fusion with a standard fluoroscopy-guided device. Results : A total of 139 screws were correctly positioned. We analyzed the positions of 135 screws except for the four screws that performed the lateral mass screws in C3 vertebra. Minor screw penetration was observed in seven cases (5.2%), and major pedicle screw penetration was observed in three cases (2.2%). In one case, the malposition of a C2 pedicle screw was confirmed, which was subsequently corrected. There were no complications regarding vertebral artery injury or onset of new neurologic deficits. The screw malposition rate was lower (5.3%) in patients who underwent intraoperative CT-based navigation than that for fluoroscopy-guided cases (10.2%). And we confirmed that the operation time can be significantly reduced by surgery using intraoperative O-arm device. Conclusion : Spinal navigation using intraoperative cone-beam CT scans is reliable for posterior fixation in unstable C1-2 pathologies and can be reduced the operative time.

Automatic Segmentation of Trabecular Bone Based on Sphere Fitting for Micro-CT Bone Analysis (마이크로-CT 뼈 영상 분석을 위한 구 정합 기반 해면뼈의 자동 분할)

  • Kang, Sun Kyung;Kim, Young Un;Jung, Sung Tae
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.3 no.8
    • /
    • pp.329-334
    • /
    • 2014
  • In this study, a new method that automatically segments trabecular bone for its morphological analysis using micro-computed tomography imaging was proposed. In the proposed method, the bone region was extracted using a threshold value, and the outer boundary of the bone was detected. The sphere of maximum size with the corresponding voxel as the center was obtained by applying the sphere-fitting method to each voxel of the bone region. If this sphere includes the outer boundary of the bone, the voxels included in the sphere are classified as cortical bone; otherwise, they are classified as trabecular bone. The proposed method was applied to images of the distal femurs of 15 mice, and comparative experiments, with results manually divided by a person, were performed. Four morphological parameters-BV/TV, Tb.Th, Tb.Sp, and Tb.N-for the segmented trabecular bone were measured. The results were compared by regression analysis and the Bland-Altman method; BV/TV, Tb.Th, Tb.Sp, and Tb.N were all in the credible range. In addition, not only can the sphere-fitting method be simply implemented, but trabecular bone can also be divided precisely by using the three-dimensional information.

Morphological Changes of Hair Structure by UV Irradiation (자외선 조사에 의한 모발구조의 형태학적 변화)

  • Kim, Jung-Hoan;Lee, Ok-Sub;Han, Ji-Sook;Shin, Sung-Yeon;Baek, Doo-Hyun;Ha, Byung-Jo
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.34 no.4
    • /
    • pp.311-316
    • /
    • 2008
  • In this study, we have investigated the effects of ultraviolet (UV) irradiation on the external and internal structure of human hair. For changes in morphological and chemical structure of UV-exposed hair, we utilized several microscopic techniques such as scanning electron microscope (SEM), transmission electron microscope (TEM), confocal laser scanning microscope (CLSM), and etc. The SEM showed the scales of UV-exposed hair appeared to be rough and bulkier because of chemical oxidation during UV irradiation. Small bulgy area of UV_exposed hair surface was appeared as a result of the decomposition in cysteic acid. In the TEM picture the UV-exposed hair showed the cleaved aperture of hair and destruction of melanin granules. Three dimensional topographical images were obtained by using CLSM. In the optical single section, high fluorescent intensity appeared in virgin hair. In the case of UV-exposed hair, low fluorescence intensity appeared. This means the aromatic amino acids in virgin hair were more abundant than UV-exposed hair.

Moving Image Compression with Splitting Sub-blocks for Frame Difference Based on 3D-DCT (3D-DCT 기반 프레임 차분의 부블록 분할 동영상 압축)

  • Choi, Jae-Yoon;Park, Dong-Chun;Kim, Tae-Hyo
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.37 no.1
    • /
    • pp.55-63
    • /
    • 2000
  • This paper investigated the sub-region compression effect of the three dimensional DCT(3D-DCT) using the difference component(DC) of inter-frame in images. The proposed algorithm are the method that obtain compression effect to divide the information into subband after 3D-DCT, the data appear the type of cubic block(8${\times}$8${\times}$8) in eight difference components per unit. In the frequence domain that transform the eight differential component frames into eight DCT frames with components of both spatial and temporal frequencies of inter-frame, the image data are divided into frame component(8${\times}$8 block) of time-axis direction into 4${\times}$4 sub block in order to effectively obtain compression data because image components are concentrate in corner region with low-frequency of cubic block. Here, using the weight of sub block, we progressed compression ratio as consider to adaptive sub-region of low frequency part. In simulation, we estimated compression ratio, reconstructed image resolution(PSNR) with the simpler image and the complex image contained the higher frequency component. In the result, we could obtain the high compression effect of 30.36dB(average value in the complex-image) and 34.75dB(average value in the simple-image) in compression range of 0.04~0.05bpp.

  • PDF

Three Dimensional Study of Miniscrew about Installation Area and Angle (미니스크류 식립 각도 및 부위에 대한 3차원적 연구)

  • Jo, Hee-Sang;Lee, Jin-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.203-211
    • /
    • 2008
  • Minimizing damage to anatomical structure is a prerequisite for skeletal anchorage system to install a miniscrew. This research has focused on evaluating the stability and safety of installation in the maxillary molar buccal area, in which most miniscrews are installed clinically and initial fixation is weak. CT (computerized tomography)images were taken for surveying the possibility of damaging to adjucent teeth in accordance with installation angle. If we install a mini-screw($1.2{\times}6.0mm$) in the maxillary molar buccal area, it would be located generally in the 5~8mm upper of CEJ and 3~5mm inner of the cortical bone surface. We has measured the space between roots And comparison has been made for gender and the space between roots in accordance with the 3 different angles of installation(30 degree, 40 degree, 60 degree) in 3 categories. Category 1 : between 1st molar and 2nd molar Category 2 : between 1st molar and 2nd premolar Category 3 : between 1st premolar and 2nd premolar The result are as follow; 1. The space for category 1 was significantly small. 2. For the installation angle, it was safer to install with steeper angle in category 1 and category 2, but not in category 3. According to these results, the installation a miniscrew in category 2, 3 is safer than in category 1. And it is safer to install with steeper angle in category 1 and category 2.

Ex Vivo ${1}^H$ MR Spectroscopy: Normal gastric and cancer tissue (정상 위 조직과 위암 조직의 시험관 내 수소자기공명분광)

  • Cho Ji Youn;Shin Oon Jae;Choi Ki Seung;Kim Su Hyun;Eun Choong Ki;Yang Young Il;Lee Jung Hee;Mun Chi Woong
    • Journal of Gastric Cancer
    • /
    • v.3 no.3
    • /
    • pp.151-157
    • /
    • 2003
  • Purpose: In this study, we attempted to ascertain the proton magnetic resonance spectroscopy (${1}^H$ MRS) peak characteristics of human gastric tissue layers and finally to use the metabolic peaks of MRS to distinguish between normal and abnormal gastric specimens. Materials and Methods: Ex-vivo ${1}^H$ MRS examinations of thirty-five gastric specimens were performed to distinguish abnormal gastric tissues invaded by carcinoma cells from normal stomach-wall tissues. High-resolution 400-MHz (9.4-T) ${1}^H$ nuclear magnetic resonance (NMR) spectra of two gastric layers, a proper muscle layer, and a composite mucosasubmucosa layer were compared with those of clinical 64- MHz (1.5-T) MR spectra. Three-dimensional spoiled gradient recalled (SPGR) images were used to determine the size and the position of a voxel for MRS data collection. Results: For normal gastric tissue layers, the metabolite peaks of 400-MHz ${1}^H$ MRS were primarily found to be as follows: lipids at 0.9 ppm and 1.3 ppm; alanine at 1.58 ppm; N-acetyl neuraminic acid (sialic acid) at 2.03 ppm; and glutathione at 2.25 ppm in common. The broad and featureless featureless spectral peaks of the 64-MHz MRS were bunched near 0.9, 1.3, and 2.0, and 2.2 ppm in human specimens without respect to layers. In a specimen (Borrmmann type III) with a tubular adenocarcinoma, the resonance peaks were measured at 1.26, 1.36 and 3.22 ppm. All the peak intensities of the spectrum of the normal gastric tissue were reduced, but for gastric tumor tissue layers, the lactate peak split into 1.26 and 1.39 ppm, and the peak intensity of choline at 3.21 ppm was increased. Conclusion: We found that decreasing lipids, an increasing lactate peak that split into two peaks, 1.26 ppm and 1.36 ppm, and an increasing choline peak at 3.22 ppm were markers of tumor invasion into the gastric tissue layers. This study implies that MR spectroscopy can be a useful diagnostic tool for gastric cancer.

  • PDF

Lip and perioral soft tissue changes after bracket bonding using 3-D laser scanner (브라켓의 접착 전후 입술 주위 연조직의 3차원적 변화)

  • Lee, Won-Je;Lee, Kee-Joon;Yu, Hyung-Seog;Baik, Hyoung-Seon
    • The korean journal of orthodontics
    • /
    • v.41 no.6
    • /
    • pp.411-422
    • /
    • 2011
  • Objective: The aim of this study was to evaluate the lip and perioral soft tissue changes after bracket bonding. Methods: The soft tissue changes in 45 adult patients (age greater than 18 years and less than 29 years) without severe skeletal discrepancy were evaluated using three-dimensional images acquired with a laser scanner before and after bracket bonding was performed using 4 types of labial orthodontic brackets. Results: Among the statistically significant changes in distance observed for the landmarks, the biggest change was observed in forward movement. The landmarks on the lateral sides also showed significant changes. While the landmarks on the upper lip showed significant upward movement, those on the lower lip showed significant downward movement. However, the changes were smaller for the landmarks on the upper lip (average, 0.87 mm) than for the landmarks on the lower lip (average, 1.21 mm). The type of bracket used did not significantly affect the soft tissue changes. Conclusions: These findings will help predict soft tissue changes after bracket bonding for orthodontic treatment.

THE STUDY BY USING THE COMPUTERIZED TOMOGRAPHY IMAGING IN ORDER TO ACCESS TO MANDIBULAR FORAMEN WHILE INFERIOR ALVEOLAR NERVE ANESTHESIA (하치조신경 마취시 하악공으로의 접근을 위한 전산화단층촬영을 통한 방사선적 연구)

  • Kim, Ji-Kwang;Gu, Hong;An, Jin-Suk;Kook, Min-Suk;Park, Hong-Ju;Oh, Hee-Kyun;Cho, Jin-Hyoung
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.6
    • /
    • pp.566-574
    • /
    • 2006
  • Purpose : This study was performed to provide an anatomical information of the mandibular ramus for the successful inferior alveolar nerve block. Three dimensional images were reconstructed from the computerized tomography (CT) and the anatomical evaluation of the mandibular ramus was done. Materials and methods : Sixty-four patients who had been taken the facial CT scans from 2000, Jan to 2003, June was selected. The patients who had the anterior or posterior teeth misssing, edentulous ridge, and jaw fracture were excepted. In the occulusal plane, the lingual surface angle (LSA) between the mid-sagittal plane and the mandibular molar lingual surface from the 2nd premolar to the 2nd molar, the inner ramal surface angle (IRSA), the maximum inner ramal surface angle (MxIRSA), and the outer ramal surface angle (ORSA) to the-mid sagittal plane were measured. The inner ramal surface angle in the ligular tip level (IRSA-L) and the outer ramal surface angle in the ligular tip level (ORSA-L), the ramal length (RL), and the anterior ramal length (ARL) were also measured in the lingular tip level. Results : In the lingular tip level, the mean IRSA-L and ORSA-L were $28.6{\pm}6.3^{\circ}$ and $17.9{\pm}4.9^{\circ}$ respectively. The larger was the IRSA, the larger was the ORSA. In the lingular tip level, the mean ramal length was 35.8${\pm}$3.4 mm. The larger was the IRSA-L, the shorter was the ramal length. On the lingular tip level, the mean anterior ramal length from anterior ramus to lingular tip was 19.6${\pm}$3.3 mm. when the ramal length was longer, the anterior ramal length was also longer. On the lingular tip level, there was positive correlation vetween the IRSA and the ORSA, negative correlation between the IRSA and the ramal length, and positive correlation between the ramal length and the lingular tip level to the anterior ramus. There was no statistical meaning of data between sex and age. Conclusion : In the clinical view of the results so far achieved, if the direction of needle is closer to posterior it is able to contact bone on lingular tip when the internal surface of ramus is wided outer.

Accuracy of linear measurement using cone-beam computed tomography at different reconstruction angles

  • Nikneshan, Sima;Aval, Shadi Hamidi;Bakhshalian, Neema;Shahab, Shahriyar;Mohammadpour, Mahdis;Sarikhani, Soodeh
    • Imaging Science in Dentistry
    • /
    • v.44 no.4
    • /
    • pp.257-262
    • /
    • 2014
  • Purpose: This study was performed to evaluate the effect of changing the orientation of a reconstructed image on the accuracy of linear measurements using cone-beam computed tomography (CBCT). Materials and Methods: Forty-two titanium pins were inserted in seven dry sheep mandibles. The length of these pins was measured using a digital caliper with readability of 0.01 mm. Mandibles were radiographed using a CBCT device. When the CBCT images were reconstructed, the orientation of slices was adjusted to parallel (i.e., $0^{\circ}$), $+10^{\circ}$, $+12^{\circ}$, $-12^{\circ}$, and $-10^{\circ}$ with respect to the occlusal plane. The length of the pins was measured by three radiologists, and the accuracy of these measurements was reported using descriptive statistics and one-way analysis of variance (ANOVA); p<0.05 was considered statistically significant. Results: The differences in radiographic measurements ranged from -0.64 to +0.06 at the orientation of $-12^{\circ}$, -0.66 to -0.11 at $-10^{\circ}$, -0.51 to +0.19 at $0^{\circ}$, -0.64 to +0.08 at $+10^{\circ}$, and -0.64 to +0.1 at $+12^{\circ}$. The mean absolute values of the errors were greater at negative orientations than at the parallel position or at positive orientations. The observers underestimated most of the variables by 0.5-0.1 mm (83.6%). In the second set of observations, the reproducibility at all orientations was greater than 0.9. Conclusion: Changing the slice orientation in the range of $-12^{\circ}$ to $+12^{\circ}$ reduced the accuracy of linear measurements obtained using CBCT. However, the error value was smaller than 0.5 mm and was, therefore, clinically acceptable.

Real-Time Stereoscopic Visualization of Very Large Volume Data on CAVE (CAVE상에서의 방대한 볼륨 데이타의 실시간 입체 영상 가시화)

  • 임무진;이중연;조민수;이상산;임인성
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.8 no.6
    • /
    • pp.679-691
    • /
    • 2002
  • Volume visualization is an important subarea of scientific visualization, and is concerned with techniques that are effectively used in generating meaningful and visual information from abstract and complex volume datasets, defined in three- or higher-dimensional space. It has been increasingly important in various fields including meteorology, medical science, and computational fluid dynamics, and so on. On the other hand, virtual reality is a research field focusing on various techniques that aid gaining experiences in virtual worlds with visual, auditory and tactile senses. In this paper, we have developed a visualization system for CAVE, an immersive 3D virtual environment system, which generates stereoscopic images from huge human volume datasets in real-time using an improved volume visualization technique. In order to complement the 3D texture-mapping based volume rendering methods, that easily slow down as data sizes increase, our system utilizes an image-based rendering technique to guarantee real-time performance. The system has been designed to offer a variety of user interface functionality for effective visualization. In this article, we present detailed description on our real-time stereoscopic visualization system, and show how the Visible Korean Human dataset is effectively visualized on CAVE.