• Title/Summary/Keyword: Three Rs

Search Result 349, Processing Time 0.022 seconds

System Integration for M20J Simulator Develoment (M20J 시뮬레이터 개발을 위한 시스템 통합)

  • Hong, S.P.;Kim, Y.H.;Chung, S.H.;Baek, J.H.;Hwang, S.C.;Hwang, M.S.;Kim, C.Y.
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.7 no.1
    • /
    • pp.19-29
    • /
    • 1999
  • This paper proposes a system intergration method for M20J flight simulator development. The simulator consists of three modules. The first module is for flight dynamics simulation, and the second module is for avionic systems and flight instrument and the last module is for interface card which connects PC and input devices using rotary encoders and switches. Two computers are equipped in the simulator for instructor and trainee. An instructor can give a mission to a trainee, and control the flight simulation options through RS-232C serial port. Also, the instructor can monitor the training results of the trainee.

  • PDF

New Techology of Intercompany Information Communication: Development of EDI System (기업간 정보 통신의 신기술)

  • 최창원;김태윤
    • Korean Management Science Review
    • /
    • v.10 no.1
    • /
    • pp.59-80
    • /
    • 1993
  • Electronic data interchange (EDI) is a new technology of information communication which can make offices paperless. This study develop an EDI system to communicate informations among companies using computer systems. The system consists of five modules-document I/O, translation, system management, communication, and additional modules. The database of EDI documentation standards has been constructed by the table-driven method. The communication module provides three communication modes-RS232C, MODEM, and message handling system (MHS). The system performance has been improved by the method of data compression and data encryption which prevent the communication delay and illegal users. This EDI system can be used as a front-end, back-end, or stand-alone mode.

  • PDF

Analysis and Optimization of a 2-Class-based Dedicated Storage System (2지역/지정위치 저장시스템의 분석과 최적화)

  • Yang, Moonhee
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.29 no.3
    • /
    • pp.222-229
    • /
    • 2003
  • In this paper, we address a layout design problem, PTN[2], for determining an appropriate 2-class-based dedicated storage layout in a class of unit load storage systems. Our strong conjecture is that PTNI2] is NP-hard. Restricting PTN[2], we provide three solvable cases of PTN[2] in which an optimal solution to the solvable cases is one of the partitions based on the PAI(product activity index)-nonincreasing ordering. However, we show with a counterexample that a solution based on the PAI-non increasing ordering does not always give an optimal solution to PTN[2]. Utilizing the derived properties, we construct an effective heuristic algorithm for solving PTN[2] based on a PAI-non increasing ordering with performance ratio bound. Our algorithm with O($n^2$) is effective in the sense that it guarantees a better class-based storage layout than a randomized storage layout in terms of the expected single command travel time.

New Conceptual Handling Systems in Container Terminals

  • Kim, Kap Hwan;Phan, Mai-Ha Thi;Woo, Youn Ju
    • Industrial Engineering and Management Systems
    • /
    • v.11 no.4
    • /
    • pp.299-309
    • /
    • 2012
  • This paper introduces some of the developments related to the handling equipment in container terminals and various new conceptual handling systems that have been proposed during the last several decades. The basic ideas behind the previous equipment improvements are analyzed to identify future directions that can be used for devising new handling systems. The handling systems in the container terminals include a quayside handling system, transport system, and yard system. In response to the deployment of mega-sized vessels for container transportation systems, productivity improvement has become one of the most urgent issues in the container terminals. This paper analyzes the previous improvements made for achieving higher productivity in the three subsystems of container handling. Some conceptual handling systems are introduced including the linear motor conveyance system (LMCS), automated storage and retrieval systems (AR/RS), overhead grid rail (GRAIL), SPEEDPORT, SuperDock, the automated container system by ZPMC (ACS-ZPMC), and AUTOCON.

Comparison of Erythrocyte Traits Among European, Japanese and Korean

  • Kwon, Ji-Sun;Kim, Sang-Soo
    • Genomics & Informatics
    • /
    • v.8 no.3
    • /
    • pp.159-163
    • /
    • 2010
  • Erythrocyte traits are heritable and indirect indicators of blood diseases caused by erythrocyte, but their genetic factors are largely unknown. So we performed genome-wide association study in 8,842 Korean individuals to identify genetic factors influencing erythrocyte traits. We identified 40 associations for three erythrocyte traits at genome-wide significance levels (p < $1{\times}10^{-6}$). We compared these associated loci with those reported in genome-wide association studies of European and Japanese. Our findings include previously identified loci(HBS1L-MYB, TMPRSS6, USP49 and CCND3) in other studies and novel associations (MRDS1/OFCC1, CSDE1, NRAS and 8 other loci). For example, SNP rs4895440 of HBS1L-MYB intergenic region on chromosome 6q23.3 is one of the most associations influencing erythrocyte traits (p=$8.33{\times}10^{-27}$).

Calculation of correction factor in PLS luminous flux measurement with integrating sphere (적분구를 이용한 PLS 광속측정의 보정계수 산출 및 적용)

  • Lee, Jung-Wook;Park, Kyung-Hoon;Yoo, Jae-Kyu
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.13-15
    • /
    • 2006
  • This paper describes the problem generated in PLS luminous flux measurement with integrating sphere. In RS case, we don't use the center position of the sphere but side position for flux test The difference of the lamp position makes the luminous flux difference of same light source. We confirmed the phenomenon with three other kinds of lamps and ensured the repeatability and reliability of this work at two laboratories. finally, the correction factor which should be applied for the PLS test at Side position was calculated.

  • PDF

The Development of 3D based On-Machine Measurement Operating System (3D 기반의 기상측정 운영시스템 개발)

  • 윤길상;최진화;조명우;김찬우
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.7
    • /
    • pp.145-152
    • /
    • 2004
  • This paper proposed efficient manufacturing system using the OMM (on-machine measurement) system. The OMM system is software based 3D modeler for inspection on machine and it is interfaced tool machine with RS232C. The software is composed of two inspection modules that one is touch probe operating module and the other is laser displacement sensor operating module. The module for touch probe has need of inspection feature that extracted it from CAD data. Touch probe moves to workpiece by three operating modes as follows: manual, general and automatic mode. The operating module of laser displacement sensor is used inspection for profile and very small hole. An Advantage of this inspection method is to be able to execute on-line inspection during machining or after it. The efficiency of proposed system which can predict and definite the machining errors of each process is verified, so the developed system is applied to inspect the mold-base(cavity, core).

STRAIN CHANGES OF ACRYLIC RESIN SPECIMENS CURED BY THREE CURING CYCLES

  • Kang, In-Ho;Kim, Yung-Soo;Kim, Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.3
    • /
    • pp.236-245
    • /
    • 2002
  • The acrylic resin was first introduced as denture base materials in 1937 and it is commonly used for denture base fabrication nowadays. Three different curing cycles (Conventional curing cycle, short curing cycle and long curing cycle) and three commercially available heat-activated acrylic resins (Vertex RS, Lucitone 199 and ProBase Hot) were investigated to find the curing cycle and material that showed the minimum shrinkage of the resin during polymerization process. A brass master mold was fabricated and duplicated by additional silicone impression material. Stone molds were made by pouring of type III dental stone (SILKY-ROCK YELLOW, Whip-Mix, Louisville, Kentucky). It was embedded in the flask. Strain gauge and thermocouple were embedded in the specimen. Strain gauge and thermocouple were connected to signal conditioning amplifier and data was recorded by pre-programmed software. The parameters ESmax (Maximum expansion strain), Sb (Strain measured just before deflasking procedure), Sa (Strain measured just after deflasking procedure) and Sf (Strain measured at the end of the experiment) were measured. ${\Delta}$S was calculated from Sb and Sa (${\Delta}$S=Sb-Sa). In the experiment concerned about materials, the parameters 90-ESmax (Maximum expansion strain measured during early 90 minutes of curing procedure), 180-ESmax (Maximum expansion strain measured from 90 minutes to 180 minutes), Sb, Sa, ${\Delta}$S and Sf were measured and the following conclusions were made. 1. The ESmax value of conventional curing cycle showed the largest value and the 180-ESmax value of Lucitone 199 showed the smallest value. 90-ESmax values showed no significant difference (p<0.05). 2. ${\Delta}$S values of conventional curing cycle showed the positive values. ${\Delta}$S values of short curing cycle and long curing cycle showed the negative values. All three materials cured by conventional curing cycle showed the positive values. 3. The Sf values of long curing cycle and ProBase Hot (cured by conventional curing cycle) showed the smallest values.

Associations Between Three Polymorphisms in the Interleukin-4 Receptor Gene and Risk of Cancer: a Meta-analysis

  • Wang, Jia-Yi;Zhou, Yu-Qiao;Li, Xiao-Xu;Jin, Xin;Wang, Li-Li;Lei, Lei;Zhou, Yu;Lu, Jiang;Zeng, Xin;Dan, Hong-Xia;Liao, Ga;Chen, Qian-Ming
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.12
    • /
    • pp.6227-6232
    • /
    • 2012
  • Interleukin-4 receptor (IL-4R) gene single nucleotide polymorphisms (SNPs) are implicated in cancer development. However, results from the published reports have remained inconclusive. The objective of this study was to conduct a meta-analysis investigating the association between polymorphisms in IL-4R gene and cancer risk. Pubmed, EMBASE and China National Knowledge Infrastructure (CNKI) were searched for case-control studies published up to October 30, 2012 that investigated IL-4R polymorphisms and cancer risk. Odds ratios (ORs) and 95% confidence intervals (CIs) were used to evaluate the strength of any associations. Three IL-4R polymorphisms (Q576R, rs1801275; I75V, rs1805010; S503P, rs1805015) in 21 case-control studies were analyzed. Our meta-analysis indicated that these three polymorphisms are not associated with cancer risk when all studies were pooled together. In the subgroup analysis by tumor site, the results showed that Q576R G allele carriers were associated with a significantly decreased cervical cancer risk (recessive model: OR = 0.77, 95%CI = 0.60-0.98; homozygote comparison: OR = 0.76, 95%CI = 0.58-0.98). I75V G allele carriers were associated with a decreased risk of renal cancer (dominant model = 0.71, 95%CI = 0.57-0.89, heterozygote comparison: OR = 0.69, 95%CI = 0.55-0.87). When stratified by ethnicity, Q576R G allele carriers were associated with a decreased cancer risk in Caucasians (dominant model: OR = 0.90, 95%CI = 0.83-0.98; heterozygote comparison: OR = 0.89, 95%CI = 0.82-0.98). I75V G allele carriers were associated with a decreased cancer risk in Asians (heterozygote comparison: OR = 0.76, 95%CI = 0.62-0.94). S503P C allele carriers were also associated with a decreased cancer risk in Asians (CC VS TT: OR = 0.29, 95%CI = 0.08-0.99). Our results suggest that Q576R, I75V and S503P may be associated with a decreased cancer risk for certain types of cancers and in some specific ethnic groups. Future case-control studies with large sample size are needed to evaluate these associations in detail.

Verification of CDOM Algorithms Based on Ocean Color Remote Sensing Data in the East Sea (동해에서 해색센서를 이용한 CDOM추정 알고리즘 검증)

  • Kim, Yun-Jung;Kim, Hyun-Cheol;Son, Young-Baek;Park, Mi-Ok;Shin, Woo-Chur;Kang, Sung-Won;Rho, Tae-Keun
    • Korean Journal of Remote Sensing
    • /
    • v.28 no.4
    • /
    • pp.421-434
    • /
    • 2012
  • Colored Dissolved Organic Matter (CDOM) is one of the important components of optical properties of seawater to determine ecosystem dynamics in a given marine area. The optical characteristics of CDOM may depend on the various ecosystem and environmental variables in the sea and those variables may vary region to region. Therefore, the retrieval algorithm for determining light absorption coefficient of CDOM ($a_{CDOM}$) using satellite remote sensing reflectance ($R_{rs}$) developed from other region may not be directly applicable to the other region, and it must be validated using an in-situ ground-truth observation. We have tested 6 known CDOM algorithms (three Semi-analytical and three Empirical CDOM algorithms) developed from other regions of the world ocean with laboratory determined in-situ values for the East Sea using field data collected during seven oceanographic cruises in the period of 2009~2011. Our field measurements extended from the coastal waters to the open oceanic type CASE-1 Waters. Our study showed that Quasi-Analytical Algorithm (QAA_v5) derived $a_{CDOM}$(412) appears to match in-situ $a_{CDOM}$(412) values statistically. Semi-analytical algorithms appeared to underestimate and empirical ones overestimated $a_{CDOM}$ in the East Sea. $a_{CDOM}$(412) value was found to be relatively high in the relatively high satellite derived-chlorophyll-a area. $a_{CDOM}$(412) value appears to be influenced by the amount of chlorophyll-a in seawater. The outcome of this work may be referenced to develop $a_{CDOM}$ algorithm for the new Korean Geostationary Ocean Color Imager (GOCI).