• 제목/요약/키워드: Thread Profile

검색결과 20건 처리시간 0.028초

국산 척추경 나사못 설계를 위한 parametric study (Parametric study on the development of pedicular screw suitable for Korean)

  • 송정일;배성인;최영철;안면환
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.167-168
    • /
    • 1998
  • The purpose of this study is to verify the biomechanical characteristics of the custom-made(our) pedicle screws which are designed the different types of shape, pitch, and profile. The results of experiments for our pedicle screw were summarized. 1) The screw of larger outer diameter showed greater holding strength. 2) The holding strength of cylindrical shaped screw was superior to that of conical shaped screw. 3) The holding strength of buttress shape of thread profile showed superior to that of V-shape. 4) The pull out and holding strength of our pedicle screws was superior to that of commercialized screw (Diapason and CD) which is widely used.

  • PDF

광학적 기법을 이용한 회전체 인프로세스 측정에 관한 연구 (A Study on the In-Process Measurement of Rotary Body by Optical Technique)

  • 소의열;임영호;유봉환
    • 한국정밀공학회지
    • /
    • 제13권5호
    • /
    • pp.148-156
    • /
    • 1996
  • Automatic product system is gradually increasing according to development of industrial society. On-line measurement makes a important role in view of economic and effective side in industrial product system. Syncronization system is developed to measure screw thread which is rotating. In-process measuring of rotating body have a lot of difficuties even thoufht using various method containing high speed camera. So, now we suggest one of the new method which is not so expansive. In this study, digital value was produced through the image processing algorithm from acquired orignal image. As a result, we have a good agreement between measuring values calculated from image conture and measuring values acquired from profile project by means of experiment, respectively.

  • PDF

피치가 다른 다축 태핑에서의 가공 특성과 품질 평가에 관한 연구 (A Study on the Multi Tapping Process Characteristics and Tread Quality under Difference Pitch)

  • 이종형;이창헌;김영문;이상영;이상중
    • 한국산업융합학회 논문집
    • /
    • 제9권4호
    • /
    • pp.277-283
    • /
    • 2006
  • As the products such as HDD, Notebook, PDA, and Mobile Phone become smaller and thinner, the radius of threads as well as holes for assembling those products become smaller, even down to 1mm. To produce such small holes and thread efficiently, multi tapping is highly necessitated. However the multi tapping characteristics is not well known because its complicated cutting mechanism and thus the quality of the produced holes and threads is not well studied yet. In this paper, experiments have been conducted for small-radius threads using M2 and M2.6 and M3 cold forming tap to investigate multi tapping process using several useful signal such as torque and Z-axis encoder pulse. The surface and profile of the machined threads have been magnified and observed through a SEM.

  • PDF

광선추적을 이용한 정밀나사 비전검사용 광학계의 결상특성 향상 (Improvement of the Optical Characteristics of Vision System for Precision Screws Using Ray Tracing Simulation)

  • 백순보;이기연;주원종;박근;나승우
    • 한국정밀공학회지
    • /
    • 제28권9호
    • /
    • pp.1094-1102
    • /
    • 2011
  • Recent trends for the miniaturization and weight reduction of portable electronic parts is the use of subminiature components. Assembly of the miniaturized components requires subminiature screws of which pitch sizes are in a micrometer scale. To produce such a subminiature screw with high precision threads, not only a precision forming technology but also high-precision measurement technique is required. In the present work, a vision inspection system is developed to measure the thread profile of a subminiature screw. Optical simulation based on a ray tracing method is used to design and analyze the optical system of the vision inspection apparatus. Through this simulation, optical performance of the developed vision inspection system is optimized. The image processing algorithm for the precision screw inspection is also discussed.

Counter Flow 방식의 랙 다이를 이용한 고정밀도 Worm 전조기술 개발 (Development of form rolling technology for high precision worm using the rack dies of counter flow type)

  • 고대철;박준모;김병민
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1861-1864
    • /
    • 2003
  • The objective of this study is to suggest the form rolling technology to produce high precision worm. Rack dies and roll dies are usually used to roll parts with worm teeth. The form roiling processes of worm shaft used as automotive part using the rack dies of counter flow type and the roll dies are considered and simulated by the commercial finite element code, DEFORM-3D. It is also important to determine the initial blank diameter in form rolling because it affects the quality of thread. The calculation method of the initial blank diameter in form rolling is suggested and it is verified by FE-simulation. The experiments using rack dies and roll dies are performed under the same conditions as those of simulation. The results of simulation and experiment in this study show that the from rolling process of worm shaft using the rack dies is decidedly superior to that using rolling dies from the aspect of the surface roughness and the profile of worm.

  • PDF

내측연결 시스템에서 임플란트 고정체의 경부 형태에 따른 지지골에서의 유한요소 응력분석 (Finite Element Stress Analysis in Supporting Bone according to Crest Module Shape of Fixture in Internal Connection System)

  • 박영남;김희중;오상호;정재헌
    • 구강회복응용과학지
    • /
    • 제22권1호
    • /
    • pp.55-74
    • /
    • 2006
  • The external contour of an implant can have significant effects on the load transfer characteristics and may result in different bone failure rates for different implant system. The purpose of this study was to investigate the effects of crest module shape and occlusal load direction on bone failure modes of five commercially available dental implant systems. Five different implant systems with internal connection; ITI (Model 1), Astra (Model 2), Bicon (Model 3), Friadent (Model 4), and Paragon (Model 5), comparable in size, but different in thread profile and cest module shapes, were compared using the finite element method. Conclusively, in the internal connection system of the implant-abutment connection methods, the stress-induced pattern at the supporting bone according to the abutment connection form had differenence among them, and implants with narrowing crestal module cross-sections at the top of the cortical bone created more favorable load transfer characteristics in this region. But it is considered that the future study is necessary about how this difference in the magnitude of the stress have an effect on the practical clinic.

생불활성 질화물 이온도금된 티타늄 임프란트의 표면특성 및 생체적합성 (Surface characteristics and biocompatibility of bioinert nitrides ion plated titanium implant)

  • 장갑성;김흥중;박주철;김병옥;한경윤
    • Journal of Periodontal and Implant Science
    • /
    • 제29권1호
    • /
    • pp.209-231
    • /
    • 1999
  • Even though titanium(Ti) and its alloys are the most used dental implant materials, there are some problems that Ti wears easily and interferes normal osteogenesis due to the metal ions. Ti coated with bioactive ceramics such as hydroxyapatite has also such problems as the exfoliation or resorption of the coated layer, Recent studies on implant materials have been proceeding to improve physical properties of the implant substrate and biocompatibility of the implant surfaces. The purpose of the present study was to examine the physical property and bone tissue compatibility of bioinert nitrides ion plated Ti, Button type specimens(14mm in diameter, 2.32rrun in height) for the abrasion test and cytotoxicity test and thread type implants(3.75mm in diameter, 6mm in length) for the animal experiments were made from Ti(grade 2) and 316LVM stainless steel. Ti specimens were ion plated with TiN, ZrN by the low temperature arc vapor deposition, and the depth profile of the TiN/Ti, ZrN/Ti ion plated surface was examined by Auger Electron Spectroscopy. Three kind of button type specimens .of TiN/Ti, ZrN/Ti and Ti were used for abrasion test, and HEPAlClC7 cells and CCD cells were cultivated for 4 days with the specimens for cytotoxicity test. Thread type implants of TiN/Ti, ZrN/Ti, Ti, 316LVM were implanted on the femur of 6 adult dogs weighing 10kg-13kg. Two dogs were sacrified for histological examination after 45 days and 90 days, and four dogs were sacrified for the removal torque test of the implant') after 90 days. The removal torque force was measured by Autograph (Shimadzu Co., AGS-1000D series, Japan). Abrasion resistance of TiN/Ti was the highest, and that of ZrN/Ti and Ti were followed. The bioinert nitride ion plated Ti had much better abrasion resistance, compared with Ti, In the cytotoxicity test, the number of both cells were increased in all specimens, and there were no significant difference in cytotoxic reaction among all groups (p>0.1), In histological examination, 316LVM showed the soft tissue engagement in interface between the implant and bone, but the other materials after 45 days noted immature new bone formation in the medullary portion along the implant surface, and those after 90 days showed implant support by new bone formation in both the cortical and the medullary portion, The removal torque force of Tilv/Ti showed significantly higher than that of Ti(p(O,05). The difference in removal torque force between TiN/Ti and ZrN/Ti was not significant(p>0.05), and that of 316LVM was lowest among all groups(p<0.05). These results suggest that bioinert nitrides ion plated Ti can resolve the existing problems of Ti and bioactive ceramics, and it may be clinically applicable to human.

  • PDF

만곡수로에서 2차원 흐름해석 (A Two Dimensional in Bended Open Channel Flows)

  • 윤세의;이종태;이원환
    • 대한토목학회논문집
    • /
    • 제6권1호
    • /
    • pp.87-94
    • /
    • 1986
  • 일반적으로 자연하천은 수심에 비해 하폭이 크고 완만한 곡률을 나타내므로 2차원 수치모형이 실용적인 것으로 알려져 있다. 본 연구에서는 만곡수로의 흐름특성을 분석하기 위하여 2차원 부정류의 운동방정식과 연속방정식을 차분화하고 Double Sweep 알고리즘에 의한 수치해석모형을 개발하였다. 본 모형의 적용성을 입증하기 위해 L.F.M 실험수로 및 I.I.H.R 실험수로의 실측치와 비교하여 비교적 잘 일치함을 확인할 수 있었다. 벽면마찰의 영향을 감소시키기 위하여 Chezy 계수의 적절한 조정으로 실측치에 더욱 접근된 결과치를 얻을 수 있었으며, 이류항의 영향을 분석하였다. 만곡수로내의 수면형태, 최대유속선이 이동경로 및 깊이방향 평균유속의 크기와 방향을 계산할 수 있었다.

  • PDF

Whirling machine의 성능 개선을 위한 연구 (A Study on Performance Improvement of Whirling Machines)

  • 이정기;양우석;손재석;한희덕;김한수
    • 대한기계학회논문집A
    • /
    • 제29권10호
    • /
    • pp.1416-1429
    • /
    • 2005
  • In order to meet the increasing competitive pressures coupled with higher demands for component quality, whirling machines have been at the cutting edge of the automobile industry for more than 25 years. The hard whirling process can save on machining time and operation elimination. Hard whirling is done dry, without coolant. The chips carry away nearly all of the heat during cutting, leaving the workpiece cool and minimizing any thermal geometry variations. The surface finish and profile accuracy are close to grinding quality. Whirling machines usually consist of four major parts; 1) loading system that requires the necessary axial speeds, 2) head stock that needs high precision clamping and positioning system at the chuck and tailstock, 3) whirling unit that demands the high cutting speeds and cutting power fer cutting deep thread profiles and 4) unloading system that requires an easy workpiece unloading. Also, capabilities of the whirling machine can be improved by attaching a vision system to the machine. Most of whirling machines in Korean automobile industry are imported from the Leistritz company, Germany and the Hasegawa company, Japan. Tn this paper, a basic research will be performed to improve and enhance the existing whirling machines. Finally, a new Korean whirling machine will be proposed and developed.

나선형 토모테라피 방사선치료의 환자별 품질관리를 위한 라디오크로믹 필름 및 Dosimetry CheckTM의 성능평가 (Performance Evaluation of Radiochromic Films and Dosimetry CheckTM for Patient-specific QA in Helical Tomotherapy)

  • 박수연;채문기;임준택;권동열;김학준;정은아;김종식
    • 대한방사선치료학회지
    • /
    • 제32권
    • /
    • pp.93-109
    • /
    • 2020
  • 목 적: 나선형 토모테라피 방사선치료를 위한 환자별 품질관리용 라디오크로믹 필름 및 3차원 분석시스템인 Dosimetry CheckTM (DC, MathResolutions, USA)의 성능평가를 시행하였다. 대상 및 방법: 인체모형팬톰(Anderson Rando Phantom, USA)을 이용하여 위치 변이가 있는 3가지 형태의 복부 종양(130.6㎤), 복막 후면 종양(849.0㎤) 및 전 복부 전이 종양(3131.0㎤)을 모델링하였다. 조사면 고정너비(field width, FW)를 2.5-cm, 5.0-cm, 피치(pitch) 0.287, 0.43으로 하여 부위별 4개씩(plan01-plan04), 총 12개의 비교용 치료계획을 수립하였다. 이온전리함(1D)과 라디오크로믹 필름(Gafchromic EBT3, Ashland Advanced Materials, USA)을 치즈팬톰 내 삽입하는 방법(2D)과 빔 플루언스 로그정보를 이용하여 CT영상 위에 선량을 3차원으로 재구성하는 방식의 DC측정을 진행하였다. 스레드효과(thread effect)를 분석을 위해 리플(ripple) 진폭(%)를 계산하였고, 선량 분포의 패턴 분석을 위해 감마인덱스 분석(DD: 3%/DTA: 3mm, 합격 문턱 값: 95%)을 수행하였다. 결 과: 리플 진폭 측정 결과 복막 후면 종양이 평균 23.1%로 가장 높았다. 라디오크로믹 필름의 분석결과, 절대 선량 평균 1.0±0.9%, 감마인덱스분석 평균 96.4±2.2%로 95% 이상 통과하였으나 전 복부 전이 종양과 같이 넓은 부위 평가에 범위의 제한적이었다. 인체모형팬톰에 적용한 DC 분석결과 FW가 5.0-cm인 세 부위의 2D 및 3D 플랜 평균이 91.8±6.4%였다. 세 단면 및 선량 프로파일 분석을 통해 복막 후면 및 전 복부 종양 표적 전체 영역에 분석이 가능하였고, 선량-용적 히스토그램을 통한 계획 선량 대 측정의 선량 오차가 FW 및 pitch에 따라 커지는 것을 확인하였다. 결 론: DC측정방법은 별도의 측정기 없이 조사 중 측정된 빔 플루언스 로그정보만으로 3차원 환자 영상 데이터 위에 선량 오류를 구현할 수 있고 종양의 위치나 크기에 제한이 없어 크고 불규칙한 종양의 나선형 토모테라피의 치료 시 환자별 품질관리 성능이 매우 우수하며 활용도가 높을 것으로 생각한다.