• Title/Summary/Keyword: Thoracic X-Ray Images

Search Result 23, Processing Time 0.022 seconds

Investigation of Tube Voltage Range using Dose Comparison based on Effective Detector Exposure Index in Chest Radiography (흉부 X-ray 검사 시 선량 비교를 활용한 유효 Detector Exposure Index 기반의 적절한 관전압 범위 제안)

  • Shim, Jina;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.139-145
    • /
    • 2021
  • This study is to confirm the range of tube voltage for Chest X-ray in DR system by comparing with dose area product (DAP) and effective dose in efficient detector exposure index (DEI) range. GE definium 8000 was used to for the phantom study. The range of tube voltage is 60~130 kVp and of mAs is 2.5~40 mAs. The acquired images were classified into efficient DEI groups, then calculated effective dose with DAP by using a PC-Based Monte Carlo Program 2.0. The signal to noise ratio (SNR) was measured at 4 regions, including the thoracic spine, the lung area with the ribs, the lung area without the ribs, and the liver by using Picture Archiving and Communication System. The significance of the group for each tube voltage was verified by performing the kruskal-wallis test and the mann-whitney test as a post-test. When set to 4 groups dependned on the tube voltage, DAP showed significant differences; 60 kVp and 80 kVp, and 60 kVp and 90 kVp (p= 0.034, 0.021). Effective dose exhibited no statistically significant differences from the all of the group (p>0.05). SNR exhibited statistically significant differences from the all of the group in the liver except compared to 80 kVp and 90 kVp (p<0.05). Therefore, high tube voltages of 100 kVp or more need to be reconsidered in terms of patient dose and imaging in order to represent an appropriate chest X-ray image in a digital system.

Geometry and Property Database for Korean Spine Research (한국인 척추 연구를 위한 형상 / 물성 정보 구축)

  • Lee, Seung-Bock;Lee, Sang-Ho;Han, Seung-Ho;Kwak, Dai-Soon
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.10
    • /
    • pp.488-493
    • /
    • 2011
  • The Korean spine geometry and property data for researchers were made by KISTI and Catholic Institute for Applied Anatomy. We took whole spine CT, X-Ray, BMD scan for making high resolution cross-sectional spine images using more 20 donated cadavers(60 - 80 years). Then we constructed 3-dimensional volume model using serial CT images by Mimics software. The major morphometric parameters of vertebrae were measured. Mechanical motion and property data were obtained by the same cadavers using the DEXA for BMD and the spine simulator. The Korean spine geometry and property data could be used for research and development of medical device.

A study on uncertainty by passage of time of stereotactic body radiation therapy for spine metastasis cancer (척추 전이암 환자의 정위적방사선치료 시 시간 경과에 따른 불확실성에 관한 연구)

  • Cho, Yong Wan;Kim, Joo Ho;Ahn, Seung Kwon;Lee, Sang Kyoo;Cho, Jeong Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.79-86
    • /
    • 2015
  • Purpose : The purpose of this study was to determine the proper treatment time of stereotactic body radiation therapy for spine metastasis cancer by using the image guidance system of CyberKnife(Accuray Incorporated, USA) which is able to correct movements of patients during the treatment. Materials and Methods : Fifty seven spine metastasis cancer patients who have stereotactic body radiation therapy of CyberKnife participate, 8 of them with cervical spine cancer, 26 of them with thoracic spine cancer, and 23 of them with lumbar spine cancer. X-ray images acquired during the treatment were classified by treatment site. From the starting point of treatment, motion tendency of patients is analyzed in each section which is divided into every 5 minutes. Results : In case of cervical spine, there is sudden increase of variation in 15 minutes after the treatment starts in rotational direction. In case of thoracic spine, there is no significantly variable section. However, variation increases gradually with the passage of time so that it is assumed that noticeable value comes up in approximately 40 minutes. In case of lumbar spine, sharp increase of variation is seen in 20 minutes in translational and rotational direction. Conclusion : Without having corrections during the treatment, proper treatment time is considered as less than 15 minutes for cervical spine, 40 minutes for thoracic spine, and 20 minutes for lumbar spine. If treatment time is longer than these duration, additional patient alignments are required or PTV margin should be enlarged.

  • PDF

Comparison of Based on Histogram Equalization Techniques by Using Normalization in Thoracic Computed Tomography (흉부 컴퓨터 단층 촬영에서 정규화를 사용한 다양한 히스토그램 평준화 기법을 비교)

  • Lee, Young-Jun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.473-480
    • /
    • 2021
  • This study was purpose to method that applies for improving the image quality in CT and X-ray scan, especially in the lung region. Also, we researched the parameters of the image before and after applying for Histogram Equalization (HE) such as mean, median values in the histogram. These techniques are mainly used for all type of medical images such as for Chest X-ray, Low-Dose Computed Tomography (CT). These are also used to intensify tiny anatomies like vessels, lung nodules, airways and pulmonary fissures. The proposed techniques consist of two main steps using the MATLAB software (R2021a). First, the technique should apply for the process of normalization for improving the basic image more correctly. In the next, the technique actively rearranges the intensity of the image contrast. Second, the Contrast Limited Adaptive Histogram Equalization (CLAHE) method was used for enhancing small details, textures and local contrast of the image. As a result, this paper shows the modern and improved techniques of HE and some advantages of the technique on the traditional HE. Therefore, this paper concludes that various techniques related to the HE can be helpful for many processes, especially image pre-processing for Machine Learning (ML), Deep Learning (DL).

A Case of Nonrecurrent Inferior Laryngeal Nerve (비반회후두신경 치험 1례)

  • 김찬우;오승철;김선태;차흥억
    • Korean Journal of Bronchoesophagology
    • /
    • v.4 no.1
    • /
    • pp.132-136
    • /
    • 1998
  • Nonrecurrence of the inferior laryngeal nerve always results from a vascular anomaly during embryonic development of the aortic arches. The nonrecurrent inferior laryngeal nerve is important clinically for two reasons, it is vulnerable during thyroid surgery and it is associated with difficulty in swallowing. It can be suspected preoperatively from signs associated with the vascular anomaly : dysphagea, thoracic x-ray images showing evidence of retroesophageal subclavian artery, or situs inversus viscerum. If such signs are noted, a barium swallow test and chest computed tomography are justified. We experienced a case of Rt. nonrecurrent inferior laryngeal nerve, which is diagnosed thyroid papillary carcinoma.

  • PDF

Is a Camera-Type Portable X-Ray Device Clinically Feasible in Chest Imaging?: Image Quality Comparison with Chest Radiographs Taken with Traditional Mobile Digital X-Ray Devices (카메라형 휴대형 X선 장치는 흉부 촬영에서 임상적 사용이 가능한가?: 기존의 이동형 디지털 X선 장치로 촬영한 흉부 X선 사진과 영상품질 비교)

  • Sang-Ji Kim;Hwan Seok Yong;Eun-Young Kang;Zepa Yang;Jung-Youn Kim;Young-Hoon Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.138-146
    • /
    • 2024
  • Purpose To evaluate whether the image quality of chest radiographs obtained using a camera-type portable X-ray device is appropriate for clinical practice by comparing them with traditional mobile digital X-ray devices. Materials and Methods Eighty-six patients who visited our emergency department and underwent endotracheal intubation, central venous catheterization, or nasogastric tube insertion were included in the study. Two radiologists scored images captured with traditional mobile devices before insertion and those captured with camera-type devices after insertion. Identification of the inserted instruments was evaluated on a 5-point scale, and the overall image quality was evaluated on a total of 20 points scale. Results The identification score of the instruments was 4.67 ± 0.71. The overall image quality score was 19.70 ± 0.72 and 15.02 ± 3.31 (p < 0.001) for the mobile and camera-type devices, respectively. The scores of the camera-type device were significantly lower than those of the mobile device in terms of the detailed items of respiratory motion artifacts, trachea and bronchus, pulmonary vessels, posterior cardiac blood vessels, thoracic intervertebral disc space, subdiaphragmatic vessels, and diaphragm (p = 0.013 for the item of diaphragm, p < 0.001 for the other detailed items). Conclusion Although caution is required for general diagnostic purposes as image quality degrades, a camera-type device can be used to evaluate the inserted instruments in chest radiographs.

Massive hemothorax resulting from spontaneous pneumothorax (자연성 기흉으로 인한 대량의 혈흉)

  • Hong, Ji Yeon;Kim, Su Wan
    • Journal of Medicine and Life Science
    • /
    • v.17 no.1
    • /
    • pp.16-20
    • /
    • 2020
  • Spontaneous hemopneumothorax is a rare disease, and it can cause life threatening condition. It is characterized by the accumulation of more than 400 mL of blood and air in the pleural cavity without any other apparent causes. A previously healthy 22-year-old female patient presented with acute chest pain and dyspnea. Chest X-ray and computed tomography revealed a massive hemopneumothorax in the left hemithorax. The images showed a completely collapsed left lung with right-sided tracheal deviation, several pleural adhesion bands, and fluid collection with air-fluid level. We emergently performed a closed thoracostomy, and then 560 mL of fresh bloods were initially drained. We considered an emergent video-assisted thoracoscopic surgery for pulmonary wedge resection and bleeding control because of the massive hemothorax. However, the patient's vital signs were stabilized after blood transfusion and supportive cares for re-expansion pulmonary edema. The patient discharged from the hospital on 11th in-hospital day after removal of the chest tube, and there had not been any recurrence of the pneumothorax for 10 months. We suggest that treatment strategy should be decided upon individually based on the patient's condition and clinical course of the disease.

Evaluation of Approximate Exposure to Low-dose Ionizing Radiation from Medical Images using a Computed Radiography (CR) System (전산화 방사선촬영(CR) 시스템을 이용한 근사적 의료 피폭 선량 평가)

  • Yu, Minsun;Lee, Jaeseung;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.455-464
    • /
    • 2012
  • This study suggested evaluation of approximately exposure to low-dose ionization radiation from medical images using a computed radiography (CR) system in standard X-ray examination and experimental model can compare diagnostic reference level (DRL) will suggest on optimization condition of guard about medical radiation of low dose space. Entrance surface dose (ESD) cross-measuring by standard dosimeter and optically stimulated luminescence dosimeters (OSLDs) in experiment condition about tube voltage and current of X-ray generator. Also, Hounsfield unit (HU) scale measured about each experiment condition in CR system and after character relationship table and graph tabulate about ESD and HU scale, approximately radiation dose about head, neck, thoracic, abdomen, and pelvis draw a measurement. In result measuring head, neck, thoracic, abdomen, and pelvis, average of ESD is 2.10, 2.01, 1.13, 2.97, and 1.95 mGy, respectively. HU scale is $3,276{\pm}3.72$, $3,217{\pm}2.93$, $2,768{\pm}3.13$, $3,782{\pm}5.19$, and $2,318{\pm}4.64$, respectively, in CR image. At this moment, using characteristic relationship table and graph, ESD measured approximately 2.16, 2.06, 1.19, 3.05, and 2.07 mGy, respectively. Average error of measuring value and ESD measured approximately smaller than 3%, this have credibility cover all the bases radiology area of measurement 5%. In its final analysis, this study suggest new experimental model approximately can assess radiation dose of patient in standard X-ray examination and can apply to CR examination, digital radiography and even film-cassette system.

Effects of Neck and Shoulder Exercise Program on Spino-Pelvic Alignment in Subject with Forward Head Posture (목과 어깨근육 운동프로그램이 전방머리자세의 척추-골반 정렬 변화에 미치는 영향)

  • Kang, Hyojeong;Yang, Hoesong
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.7 no.4
    • /
    • pp.265-272
    • /
    • 2019
  • Purpose : Excessive computer use frequently results in musculoskeletal disorders of the neck and shoulder such as forward head posture (FHP). The purpose of this study was to investigate effects of neck and shoulder exercise program on spino-pelvic alignment and the correlation between change in head and neck posture and spino-pelvic alignment in FHP. Methods : The study included 44 participants with FHP. The participants performed the exercise for correction of FHP 2-3 times a week for 4 weeks. We examined whole spine X-ray images in the lateral standing position with both arms crossed. We measured anterior head translation distance (AHT), craniovertebral angle (CVA), cervical lordosis (CL), thoracic kyphosis (TK), lumbosacral lordosis (LSL), sacral slope (SS), pelvic tilt (PT), and pelvic incidence (PI) of the subjects. The association between change in AHT and each spino-pelvic parameter was also subjected to Pearson's correlation coefficient analysis. Results : There were statistically significant differences before and after exercise in the parameters of AHT, CVA, and SS (p<.05). Significant negative correlation was observed between the change in AHT and CVA (r=-.768, p<.001), and CL (r=-.388, p<.05). There was significant positive correlation between the change in AHT and SS (r=.328, p<.05), and PI (r=.333, p<.05). However, no significant correlation was observed in change in AHT with that of TK, LSL, and PT. Conclusion : Based on the above results, we conclude that there is a relationship between change in AHT, which is a parameter associated with forward displacement of the head, and that of CVA, CL, SS, and PI after exercise in cases of FHP.

Chest Radiographic and CT Findings of the 2019 Novel Coronavirus Disease (COVID-19): Analysis of Nine Patients Treated in Korea

  • Soon Ho Yoon;Kyung Hee Lee;Jin Yong Kim;Young Kyung Lee;Hongseok Ko;Ki Hwan Kim;Chang Min Park;Yun-Hyeon Kim
    • Korean Journal of Radiology
    • /
    • v.21 no.4
    • /
    • pp.494-500
    • /
    • 2020
  • Objective: This study presents a preliminary report on the chest radiographic and computed tomography (CT) findings of the 2019 novel coronavirus disease (COVID-19) pneumonia in Korea. Materials and Methods: As part of a multi-institutional collaboration coordinated by the Korean Society of Thoracic Radiology, we collected nine patients with COVID-19 infections who had undergone chest radiography and CT scans. We analyzed the radiographic and CT findings of COVID-19 pneumonia at baseline. Fisher's exact test was used to compare CT findings depending on the shape of pulmonary lesions. Results: Three of the nine patients (33.3%) had parenchymal abnormalities detected by chest radiography, and most of the abnormalities were peripheral consolidations. Chest CT images showed bilateral involvement in eight of the nine patients, and a unilobar reversed halo sign in the other patient. In total, 77 pulmonary lesions were found, including patchy lesions (39%), large confluent lesions (13%), and small nodular lesions (48%). The peripheral and posterior lung fields were involved in 78% and 67% of the lesions, respectively. The lesions were typically ill-defined and were composed of mixed ground-glass opacities and consolidation or pure ground-glass opacities. Patchy to confluent lesions were primarily distributed in the lower lobes (p = 0.040) and along the pleura (p < 0.001), whereas nodular lesions were primarily distributed along the bronchovascular bundles (p = 0.006). Conclusion: COVID-19 pneumonia in Korea primarily manifested as pure to mixed ground-glass opacities with a patchy to confluent or nodular shape in the bilateral peripheral posterior lungs. A considerable proportion of patients with COVID-19 pneumonia had normal chest radiographs.