• Title/Summary/Keyword: Thoracic Spine

Search Result 355, Processing Time 0.022 seconds

Kyphotic Angle Measurement Accuracy for Vertebral Osteoporotic Compression Fracture; Reliable Method for Kyphotic Angle Measurement

  • Hong, Jae-Taek;Lee, Sang-Won;Son, Byung-Chul;Sung, Jae-Hoon;Park, Choon-Keun;Kim, Moon-Chan
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.4
    • /
    • pp.256-259
    • /
    • 2006
  • Objective : Having a reliable and reproducible measurement technique to measure the sagittal contour in vertebral fractures is paramount to clinical decision making. This study is designed to determine the most reliable measurement technique in osteoporotic vertebral compression fracture. Methods : Fifteen lateral radiographs of thoracic and lumbar fractures were selected and measured on two separate occasions by three spine surgeons using six different measurement techniques [Centroid, Harrison Posterior Tangent Methods and 4 different types of modified Cobb method]. The radiograph quality was assessed and the center beam location was determined. Statistical analysis including ANOVA for repeated measures was carried out using the SAS software [v 8.0]. Results : The inter and intraobserver variance of the Cobb method 4 and Harrison posterior tangent method were significantly lower than the other four methods. The intraobserver correlation coefficients were the most consistent using the Cobb method 4 [0.982]. which was followed by the Harrison posterior tangent [0.953] and Cobb methods 1 [0.874]. The intraobserver agreement [% of repeated measures within 5 degrees of the original measurement] ranged from 42% to 98% for each technique for all three observers, with the Cobb method 4 showing the best agreement [97.8%] followed by the Harrison posterior tangent method [937%]. Conclusion : The Cobb method-4 and Harrison posterior tangent methods, when applied to measuring the kyphosis, are reliable and have a similar small error range. The Cobb method 4 shows the best overall reliability. However, the centroid method and Cobb method using a fractured endplate do not produce an accurate result due to inter and intraobserver differences in determining the baseline.

Evaluation of Global Sagittal Balance in Koreans Adults

  • Cho, Yongjae
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.5
    • /
    • pp.560-566
    • /
    • 2017
  • Objectvie : The global sagittal postural patterns as characterized by Roussouly classification have been previously described in various ethnicities, there were no studies investigated in Koreans. To analyze the distribution of the global sagittal postural patterns in Korean adults using Roussouly classification, the author prospectively studied. Methods : 252 asymptomatic Korean adults was recruited. Data was obtained by reviewing the films for each subject. Spinopelvic parameters were measured and sagittal postural patterns were then determined according to Roussouly classification. We compared the data across different ethnicities from our study and a previous study to further characterize Korean sagittal postures. Results : The subject included 151 males and 101 females, with mean age of $33.2{\pm}8.2years$. The average descriptive results were as below : thoracic kyphosis $28.6{\pm}7.7^{\circ}$, lumbar lordosis $48.3{\pm}10.2^{\circ}$, sacral slope $37.8{\pm}5.8^{\circ}$, pelvic incidence $45.1{\pm}7.5^{\circ}$, pelvic tilt $9.4{\pm}6.7^{\circ}$, spinosacral angle $130.1{\pm}5.4^{\circ}$, and sagittal vertical axis $16.25{\pm}22.5mm$. 125 subjects among 252 (49.6%) belonged to Roussouly type 3 (namely neutral). There were also 58 (23%), 33 (13.1%), and 36 (14.3) subjects in type 1, 2, and 4 (namely non-neutral), respectively. Conclusion : Enrolling 252 asymptomatic Korean adults, this prospective study found that 49.6% of asymptomatic Korean adults possessed a sagittal posture of Roussouly type 3. All radiologic parameters follows general concept of spinal sagittal balance pattern. Overall, this study might be a basis for further investigation of spinal sagittal balance.

Torticollis Management Using the Customized Soft Neck Collar in CATCH 22 Syndrome Combined with Klippel-Feil Anomaly: A Case Report

  • Moon, Myung-Hoon;Kim, Soo-Yeon
    • Journal of Interdisciplinary Genomics
    • /
    • v.1 no.2
    • /
    • pp.19-22
    • /
    • 2019
  • CATCH 22 syndrome is rare genetic disease that has various manifestations. Cervical vertebral anomaly, such as Klippel-Feil anomaly, is frequently observed in the patients with CATCH22 syndrome. We present the case of an 11-year-old female patient with CATCH22 syndrome and Klippel-Feil anomaly who had been treated torticollis using the customized soft neck collar. During the patient's first visit to our clinic, she presented with low ear set, skull deformity, intellectual disability, and tilting of the head to the left by approximately 25 degrees. Imaging studies revealed multisegmental fusion and C3 hemivertebrae of the cervical spine and left thoracic scoliosis at T4 with 50 degrees of Cobb's angle. We instructed passive stretching and applied the customized soft neck collar we invented. The ipsilateral aspect of the neck collar is designed to provide vertical support between the clavicle and mandibular angle and is adjustable in height. The Velcro was attached to the neck collar at the point of contact with the ipsilesional mandibular angle, which provides negative sensory feedback, inducing her to tilt neck to the contralesional side. We applied the neck collar for 2 hours a day. After 1 year of treatment, her neck inclination angle improved from 25 to 10 degrees. Providing negative sensory feedback using the customized soft neck collar can be one of the treatment options of postural management in patients with torticollis in cases of CATCH 22 syndrome combined with Klippel-Feil anomaly.

Outcomes of Non-Operative Management for Pseudarthrosis after Pedicle Subtraction Osteotomies at Minimum 5 Years Follow-Up

  • Kim, Yong-Chan;Kim, Ki-Tack;Kim, Cheung-Kue;Hwang, Il-Yeong;Jin, Woo-Young;Lenke, Lawrence G.;Cha, Jae-Ryong
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.5
    • /
    • pp.567-576
    • /
    • 2019
  • Objective : Minimal data exist regarding non-operative management of suspected pseudarthrosis after pedicle subtraction osteotomy (PSO). This study reports radiographic and clinical outcomes of non-operative management for post-PSO pseudarthrosis at a minimum 5 years post-detection. Methods : Nineteen consecutive patients with implant breakage indicating probable pseudarthrosis after PSO surgery (13 women/six men; mean age at surgery, 58 years) without severe pain and disability were treated with non-operative management (mean follow-up, 5.8 years; range, 5-10 years). Non-operative management included medication, intermittent brace wearing and avoidance of excessive back strain. Radiographic and clinical outcomes analysis was performed. Results : Sagittal vertical axis (SVA), proximal junctional angle, thoracic kyphosis achieved by a PSO were maintained after detection of pseudarthrosis through ultimate follow-up. Lumbar lordosis and PSO angle decreased at final follow-up. There was no significant change in Oswestry Disability Index (ODI) scores and Scoliosis Research Society (SRS) total score, or subscales of pain, self-image, function, satisfaction and mental health between detection of pseudarthrosis and ultimate follow-up. SVA greater than 11 cm showed poorer ODI and SRS total score, as well as the pain, self-image, and function subscales (p<0.05). Conclusion : Non-operative management of implant failure of probable pseudarthrosis after PSO offers acceptable outcomes even at 5 years after detection of implant breakage, provided SVA is maintained. As SVA increased, outcome scores decreased in this patient population.

Spinal Cord Infarction after C7 Transforaminal Epidural Steroid Injection Using Dexamethasone (덱사메타손을 이용한 경추 7번 경막 외 스테로이드 주사 후 척수 경색)

  • Lee, Jong Hwa;Kim, Young Sam;Kim, Sang Beom;Lee, Kyeong Woo;Kim, Young Hwan
    • Clinical Pain
    • /
    • v.19 no.2
    • /
    • pp.116-119
    • /
    • 2020
  • Cervical transforaminal epidural steroid injection (TFESI) is commonly performed to provide relief of pain caused by radiculopathy. Intra-arterial injection of particulate steroid or direct needle injury can lead to spinal artery embolism or thrombosis. Also there is a possibility of vascular spasm. To our knowledge, this is the first reported case of spinal cord infarction that occurred after TFESI with non-particulate steroid in Korea. A 47-year-old female patient underwent C7 TFESI at local pain clinic. Injected materials were dexamethasone and mepivacaine. Right after the intervention, she felt muscle weakness and decreased sensation. On physical examination, she had decreased sensation from C4 to T2 dermatome in light touch and pin-prick test. Proprioception and vibration were intact. The motor grades of upper extremities were grade 1. Cervical and thoracic spine MRI was checked. Diffusion-weighted image and apparent diffusion coefficient image showed long extension of spinal cord infarction from C2 to T1 level.

Constant score in asymptomatic shoulders varies with different demographic populations: derivation of adjusted score equation

  • Nitesh Gahlot;Ankit Rai;Jeshwanth Netaji
    • Clinics in Shoulder and Elbow
    • /
    • v.25 no.4
    • /
    • pp.274-281
    • /
    • 2022
  • Background: In the present study, the age- and sex-adjusted Constant score (CS) in a normal Indian population was calculated and any differences with other population cohorts assessed. Methods: The study participants were patients who visited the outpatient department for problems other than shoulder and healthy volunteers from the local population. Patients without shoulder pain/discomfort during activity were included in the study. Subjects with any problem that might affect shoulder function (e.g., cervical, thoracic spine, rib cage deformity, inflammatory arthritis) were excluded. Constant scoring of all participants was performed by trained senior residents under the supervision of the senior faculty. Shoulder range of movement and strength were measured following recommendations given by the research and Development Committee of the European Society for Shoulder and Elbow Surgery (2008). A fixed spring balance was used for strength measurement; one end was fixed on the floor and the other end tied with a strap to the wrist of the participant, arm in 90° abduction in scapular plane with palm facing down. Results: Among the 248 subjects (496 shoulders), the average age was 37 years (range, 18-78 years), 65.7% were males (326 shoulders) and 34.3% females (170 shoulders). The mean CS was 84.6±2.9 (males, 86.1±3.0; females, 81.8±2.9). CS decreased significantly after 50 years of age in males and 40 years of age in females (p<0.05). The mean CS was lower than in previous studies for both males and females. Heavy occupation workers had higher mean CS (p<0.05). A linear standardized equation was estimated for calculating the adjusted CS for any age. Conclusions: Mean CS and its change with age differed from previous studies among various population cohorts.

Case Report of Type-1 Diabetes Mellitus with Uncontrolled Blood Sugar Improved by Complex Korean Medicine Treatment (혈당 조절이 되지 않는 1형 당뇨병 환자에 대한 한방 치험 1례)

  • Soo-duk Kim;Min-jo Seo;Hyun-a Sim;Woo-jin Jung;Hye-ri Jo;Geon-sik Kong;Yo-sup Choi
    • The Journal of Internal Korean Medicine
    • /
    • v.44 no.2
    • /
    • pp.269-276
    • /
    • 2023
  • Objective: This study reported the effectiveness of Korean medicine for a patient with Type-1 diabetes mellitus after pancreatectomy with a compression fracture of the thoracic spine. Methods: A patient diagnosed with Type-1 diabetes mellitus after a pancreatectomy was treated with acupuncture, pharmacopuncture, Gami-hwanggigyejiomul-tang (modified Huangqi Guizhi Wuwu decotion), Jindang-won, etc. The conventional treatment was maintained using an insulin pump and insulin injection. Results: Blood glucose (FBS/PP2hrs), ESR and CRP decreased after one month of treatment. Conclusion: Gami-hwanggigyejiomul-tang and Jindang-won may be effective treatments for Type-1 diabetes mellitus. Further studies are needed to confirm the findings of this case.

The Evaluation and Development of Head and Neck Radiation Protective Device for Chest Radiography in 10 Years Children (소아(10세) 흉부 방사선촬영에서의 두경부 방사선 방어기구 개발 및 평가)

  • Lee, Jun Ho;Lim, Hyun Soo;Lee, Seung Yeol
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.2
    • /
    • pp.118-123
    • /
    • 2015
  • The frequency of diagnostic radiation examinations in medical institutions has recently increased to 220 million cases in 2011, and the annual exposure dose per capita was 1.4 mSv, 51% and 35% respectively, compared to those in 2007. The number of chest radiography was found to be 27.59% of them, the highest frequency of normal radiography. In this study, we developed a shielding device to minimize radiation exposure by shielding areas of the body which are unnecessary for image interpretation, during the chest radiography. And in order to verify its usefulness, we also measured the difference in entrance surface dose (ESD) and the absorbed dose, before and after using the device, by using an international standard pediatric (10 years) phantom and a glass dosimeter. In addition, we calculated the effective dose by using a Monte Carlo simulation-based program (PCXMC 2.0.1) and evaluated the reduction ratio indirectly by comparing lifetime attributable risk of cancer incidence (LAR). When using the protective device, the ESD decreased by 86.36% on average, nasal cavity $0.55{\mu}Sv$ (74.06%), thyroid $1.43{\mu}Sv$ (95.15%), oesophagus $6.35{\mu}Sv$ (78.42%) respectively, and the depth dose decreased by 72.30% on average, the cervical spine(upper spine) $1.23{\mu}Sv$ (89.73%), salivary gland $0.5{\mu}Sv$ (92.31%), oesophagus $3.85{\mu}Sv$ (59.39%), thyroid $2.02{\mu}Sv$ (73.53%), thoracic vertebrae(middle spine) $5.68{\mu}Sv$ (54.01%) respectively, so that we could verify the usefulness of the shielding mechanism. In addition, the effective dose decreased by 11.76% from $8.33{\mu}Sv$ to $7.35{\mu}Sv$ before and after wearing the device, and in LAR assessment, we found that thyroid cancer decreased to male 0.14 people (95.12%) and female 0.77 people (95.16%) per one million 10-year old children, and general cancers decreased to male 0.14 people (11.70%) and female 0.25 people (11.70%). Although diagnostic radiation examinations are necessary for healthcare such as the treatment of diseases, based on the ALARA concept, we should strive to optimize medical radiation by using this shielding device actively in the areas of the body unnecessary for the diagnosis.

A Study on the Use of Dong-Si Acupuncture Points at Movement System Impairment Syndrome of Shoulder and Cervical Spine (견(肩).경항부(頸項部) 동태손상증후군에서의 동씨침 혈위 활용 방안)

  • Youn, Woo Suck;Park, Young Jae;Park, Young Bae
    • Journal of Acupuncture Research
    • /
    • v.30 no.5
    • /
    • pp.1-9
    • /
    • 2013
  • Objectives : The purpose of this study was to present clinical utility of therapeutic exercise on the neck and shoulder parts based on the movement system impairment syndrome(MSIS) as Dong-Qi therapy of the Dong-Si Acupuncture and was to examine which Dong-Si acupoints were most effective and non-invasive when performing therapeutic exercise of the MSIS. Methods : Totally eight therapeutic exercises correspondent to eight neck and shoulder MSIS were summarized and tabulated from the Diagnosis and Treatment of Movement Impairment Syndrome and Movement System Impairment Syndromes Of The Extremities, Cervical and Thoracic Spines by Sahrmann SA. Together with the MSIS summaries, acupuncture points and Dong-Qi therapy were summarized and tabulated from Yangweijiequanji 1 and Yangweijiequanji 2 by Yangweijie. According to the posture and movement of the MSIS exercise, effective and non-invasive acupoints were selected. Thereafter, clinical pilot study which five normal volunteers participated in were performed to examine whether these acupoints resulted in any side effects of acupuncture therapy such as pain and distortion of the needle during the MSIS exercises. Results : Through clinical pilot study, ZhongZi, ZhongXian, ZhengJin, ZhengZong and MuLiu in a sitting position, and HuaGuYi, ZhongZi and ZhongXian in a supine position were finally determined as safe and non-invasive Dong-Si acupoints to treat cervical pain. In terms of shoulder pain, ZuQianJin, ZuWuJin, HuaGuEr and JianZhong in a supine position, SiHuaZhong, ZuQianJin, ZuWuJin, QuLing, JianZhong, ShenGuan and JiuLi in a standing position, and ZuQianJin, ZuWuJin, HuaGuEr, QuLing and JianZhong in a prone position were finally accepted as safe and non-invasive Dong-Si acupoints. Conclusion : It is concluded that Dong-Si acupoints can be safely and non-invasively used together with therapeutic exercises of the MSIS to treat cervical and shoulder pains.

Evaluation of Lung Dose Using Linac Photon Beam in Geant 4 Simulation (Geant4 Simulation에서 Linac 광자선을 이용한 폐 선량평가)

  • Jang, Eun-Sung;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.443-450
    • /
    • 2018
  • The Geant 4 simulated the linear accelerator (VARIAN CLINAC) based on the previously implemented BEAMnrC data, using the head structure of the linear accelerator. In the 10 MV photon flux, Geant4 was compared with the measured value of the percentage of the deep dose and the lateral dose of the water phantom. In order to apply the dose calculation to the body part, the actual patient's lung area was scanned at 5 mm intervals. Geant4 dose distributions were obtained by irradiating 10 MV photons at the irradiation field ($5{\times}5cm^2$) and SAD 100 cm of the water phantom. This result is difficult to measure the dose absorbed in the actual lung of the patient so the doses by the treatment planning system were compared. The deep dose curve measured by water phantom and the deep dose curve calculated by Geant4 were well within ${\pm}3%$ of most depths except the build-up area. However, at the 5 cm and 20 cm sites, 2.95% and 2.87% were somewhat higher in the calculation of the dose using Geant4. These two points were confirmed by the geometry file of Genat4, and it was found that the dose was increased because thoracic spine and sternum were located. In cone beam CT, the dose distribution error of the lungs was similar within 3%. Therefore, if the contour map of the dose can be directly expressed in the DICOM file when calculating the dose using Geant4, the clinical application of Geant4 will be used variously.