• 제목/요약/키워드: Third harmonic

검색결과 218건 처리시간 0.029초

Analysis of Surface Tracking of Micro and Nano Size Alumina Filled Silicone Rubber for High Voltage AC Transmission

  • Loganathan, N.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권2호
    • /
    • pp.345-353
    • /
    • 2013
  • This paper discusses the experimental results in an effort to understand the tracking and erosion resistance of the micro and nano size $Al_2O_3$ filled silicone rubber (SIR) material which has been studied under the AC voltages, with ammonium chloride as a contaminant, as per IEC 60587 test procedures. The characteristic changes in the tracking resistance of the micro and nano size filled specimens were analyzed through leakage current measurement and the eroded masses were used to evaluate the relative erosion and tracking resistance of the composites. The fundamental, third and fifth harmonic of the leakage current during the tracking study were analyzed using moving average current technique. It was observed that the harmonic components of leakage current show good correlation with the tracking and erosion resistance of the material. The thermogravimetry-derivative thermo gravimetric (TG-DTG) studies were performed to understand the thermal degradation of the composites. The physical and chemical studies were carried out by using scanning electron microscope (SEM), Energy Dispersive X-ray analysis (EDAX) and Fourier Transform Infra-red (FTIR) Spectroscopy. The obtained result indicated that the performance of nano filled SIR was better than the micro filled SIR material when the % wt. of filler increased.

Harmonic Winding Factors and MMF Analysis for Five-phase Fractional-slot Concentrated Winding PMSM

  • Kang, Huilin;Zhou, Libing;Wang, Jin
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권1호
    • /
    • pp.20-26
    • /
    • 2014
  • To enhance torque density by harmonic current injection, optimal slot/pole combinations for five-phase permanent magnet synchronous motors (PMSM) with fractional-slot concentrated windings (FSCW) are chosen. The synchronous and the third harmonic winding factors are calculated for a series of slot/pole combinations. Two five-phase PMSM, with general FSCW (GFSCW) and modular stator FSCW (MFSCW), are analyzed and compared in detail, including the stator structures, star of slots diagrams, and MMF harmonic analysis based on the winding function theory. The analytical results are verified by finite element method, the torque characteristics and phase back-EMF are also taken into considerations. Results show that the MFSCW PMSM can produce higher average torque, while characterized by more MMF harmonic contents and larger ripple torque.

고조파 제거 기능을 갖는 브랜치라인 커플러의 설계 (Modified Design of Branch-Line Coupler for Harmonic Suppression)

  • 김종성
    • 대한전자공학회논문지TC
    • /
    • 제47권6호
    • /
    • pp.22-25
    • /
    • 2010
  • 이 논문은 브랜치라인 커플러에서 고조파 신호를 제거할 수 있는 변형된 설계 방법을 제안한다. 기존의 1/4 파장 길의의 전송선로의 중앙에 개방형 스터브를 추가한 후에, 설계 주파수에서는 커플러의 기능을 제공하고 고조파 주파수에서는 전송을 제한하는 특성을 갖는 커플러의 해를 구하는 것이 가능하다. 이의 검증 예로서 1.0GHz에서 커플러를 제작하였으며 2.0GHz와 3.0GHz에서 -37.5dB 및 -42.7dB의 억압비를 나타내었다.

Harmonic Generator의 저주파 혼변조 신호 성분을 이용한 전치왜곡 선형화기 설계 (The Design of Predistortion Linearizer using the Low Frequency Intermodulation Terms of Harmonic Generator)

  • 김영;장익수;장형순
    • 대한전자공학회논문지TC
    • /
    • 제39권9호
    • /
    • pp.28-34
    • /
    • 2002
  • 본 논문에서 제시한 새로운 형태의 전치왜곡 회로는 Harmonic Generator에서 발생되는 저주파 혼변조 신호 성분만을 추출하여, 이것을 Vector Modulator에서 원 신호와 진폭 변조시키는 것이다. 이러한 회로를 이용하여 3차, 5차 혼변조 신호를 발생시켜 전력 증폭기의 혼변조 신호를 감쇠시키는 선형화기를 구현하였다. 구현된 전치왜곡 선형화기는 국내 개인 휴대 통신(PCS) 기지국 송신 대역인 1840MHz~1870MHz주파수에서 동작되도록 제작, 측정을 하였다. 그 결과 반송파 2-tone 신호를 인가할 때 3차 혼변조 왜곡 특성은20dB 이상, 5차 혼변조 왜곡 특성은 10dB 이상의 개선효과를 얻었고, IS-95 CDMA 신호를 인가하였을 때 인접채널 전력 비를 10dB이상 개선시켰다.

단상 변압기 지그재그 결선에 의한 3고조파 전류 저감 효과 분석 (Analysis of Reduction Effect of Three Harmonic Currents by Zigzag Wiring of Single Phase Transformer)

  • 김종겸;김지명
    • 전기학회논문지P
    • /
    • 제66권3호
    • /
    • pp.99-104
    • /
    • 2017
  • The three-phase four-wire power distribution system can be used to supply power to single-phase and three-phase loads at the same time. There are linear loads and nonlinear loads as single-phase loads connected to each phase. The nonlinear load generates a harmonic current during the power energy conversion process. In particular, the single-phase nonlinear load has a higher proportion of generation of the third harmonic current than the harmonics of the other orders. In a three-phase four-wire system, the third harmonic current flows through the neutral wire to the power supply side, affecting the power supply side and the line. Furthermore, the magnitude of the current flowing in the neutral line can be higher than the current flowing in the individual phase. If the neutral current is higher than the phase current, the breaker may be blocked. Therefore, it is necessary to reduce the amount of current flowing in the neutral line by harmonics. There is a method of zigzag connecting a single phase transformer by a method of reducing 3 harmonic current. In this study, the method of reducing the magnitude of the three harmonic currents flowing through the zigzag wire by comparing the polarity and the negative polarity characteristics of the single phase transformer was compared through measurement and simulation.

Optical Third-Harmonic Generation of Poly(2-Bromo-1,4-phenylenevinylene)

  • Hwang Do-Hoon;Lee Jeong-Ik;Lee Minyung;Shim Hong-Ku
    • Bulletin of the Korean Chemical Society
    • /
    • 제15권1호
    • /
    • pp.25-28
    • /
    • 1994
  • Weakly electron withdrawing bromine substituted poly(2-bromo-1,4-phenylenevinylene) (PBrPV) was synthesized th-rough water-soluble precursor method. The linear and nonlinear optical properties of PBrPV were compared with those of poly(1,4-phenylenevinylene) (PPV). The third-order nonlinear optical susceptibility, X^{(3)}$, was measured by using third-harmonic generation (THG) technique at 1907 nm, fundamental wavelength. The calculated $X^{(3)}$ values of PPV and PBrPV were 3${\times}$ 10$^{-12}$ esu and 2${\times}$10$^{-12}$ esu, respectively.

다중 대역 송신을 위한 디지털 사전 왜곡 기법을 이용한 비선형 전력 증폭기의 고조파 신호 선형화 (Harmonic Signal Linearization of Nonlinear Power Amplifier Using Digital Predistortion for Multiband Wireless Transmitter)

  • 오경태;구현철;김동수;한철구
    • 한국전자파학회논문지
    • /
    • 제19권12호
    • /
    • pp.1339-1349
    • /
    • 2008
  • 본 논문에서는 입력 복소 포락선 신호와 m차 고조파 대역의 출력 복소 포락선 신호 사이의 비선형성 관계를 이론적으로 분석하고, 이를 모델링하기 위하여 AM/$AM_m$, AM/$PM_m$을 정의하였다. 제안된 모델을 측정 데이터로부터 추출하는 방안을 제안하였고, InGaP 전력 증폭기에 대하여 기본 주파수 대역과 3차 고조파 대역에서의 신호를 측정하여 제안된 모델 및 기법의 유효성을 검증하였다 또한, 제안된 고조파 신호 대역에 대한 모델을 기반으로 고조파 대역 신호의 선형화를 위한 디지털 사전 왜곡 기법을 제안하였다 디지털 사전 왜곡기에서 비선형역함수 구현을 위해 수치 해석적인 방법과 Look-Up Table(LUT) 방식을 이용하였다. 고조파 신호 선형화를 위한 디지털 사전 왜곡기를 포함하는 송신기를 구현하고 16-QAM과 64-QAM의 입력 신호에 대해서 3차 고조파 출력신호의 스펙트럼과 I/Q 신호 성상도를 측정하였다. 고조파 대역에서 비선형 왜곡에 의해서 의미 없는 신호는 제안된 기법으로 구성된 송신기에 의해 선형화되었으며, 그 결과 각 신호에 대한 Error-Vector Magnitudes(EVM)이 6.4 %와 6.5 %로 측정되었다. 제안된 기법은 향후 SDR과 CR 등의 차세대 다중 대역 송신 시스템에 적용될 수 있을 것으로 사료된다.

8 GHz 대역 국부발진기용 주파수 3체배기 설계 및 제작 (Design and Fabrication of the Frequency Tripper for 8 GHz Local Oscillator)

  • 정미경;홍성용
    • 한국전자파학회논문지
    • /
    • 제13권4호
    • /
    • pp.379-385
    • /
    • 2002
  • 본 논문에서는 MESFET을 이용하여 8 GHz 대역 국부발진기용 주파수 3체배기를 설계 및 제작하였다. A급에 동작점을 두어 3차 하모닉 성분을 발생시켰고, λ$_{g}$/2 개방형 스터브와 대역통과 여파기를 이용하여 기본주파수와 2차 하모닉성분을 억제하였다. 측정결과 0 ㏈m 입력신호에 대해 출력주파수인 8.31 GHz에서의 변환이 득은 2.67 ㏈, -41.17 ㏈c의 고조파 쳐압 특성을 얻었다. 또한 -3 ㏈ 이상의 변환이득을 갖는 대역폭은 510 MHz로 나타났다.다.

A Co-design Study of Filters and Oscillator for Low Phase Noise and High Harmonic Rejection

  • Zhang, Bing;Zhang, Wenmei;Ma, Runbo;Zhang, Xiaowei;Mao, Junfa
    • ETRI Journal
    • /
    • 제30권2호
    • /
    • pp.344-346
    • /
    • 2008
  • In this paper, we present a novel oscillator (OSC) design. Bandpass filters, which can suppress harmonics, are incorporated into a co-design with an OSC to improve the OSC phase noise and harmonic rejection. The proposed OSC/bandpass filter co-design achieves a phase noise of -130.1 dBc/Hz/600 kHz and harmonic rejection of 37.94 dB and 40.85 dB for the second and third harmonics, respectively, as compared to results achieved by the OSC before co-design of -101.6 dBc/Hz/600 kHz and 21.28 dB and 19.68 dB. Good agreement between the measured and simulated results is achieved.

  • PDF