• Title/Summary/Keyword: Third Winding

Search Result 33, Processing Time 0.022 seconds

Double quench and fault current limiting characteristics due to winding ratio of transformer type SFCL with third winding

  • Han, Tae-Hee;Ko, Seok-Cheol;Lim, Sung-Hun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.3
    • /
    • pp.38-42
    • /
    • 2019
  • To protect the power systems from fault current, the rated protective equipment should be installed. However growth of power system scale and concentration of loads caused the large fault current in power transmission system and distribution system. And capacities of installed protective equipment have been exceeded the due to increase of fault current. This increase is not temporary phenomenon but will be steadily as long as the industry develops. The power system need a counter measurement for safety, so superconducting fault current limiter (SFCL) has been received attention as an effective solutions to reduce the fault current. For the above reasons various type SFCL is studied recently. In this paper, the operational characteristics and power burden of trigger type SFCL is studied. The trigger type SFCL has been used for real system research in many countries. And another trigger type SFCL (double quench trigger type SFCL) is also studied. For this paper, short circuit test is performed.

Electric Power Characteristics of a SFCL based on Turn-ratio of 3-Phase Transformer (3상 변압기의 권수비에 따른 초전도 한류기의 전력특성)

  • Jeong, In-Sung;Choi, Hyo-Sang;Jung, Byung-Ik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.3
    • /
    • pp.414-417
    • /
    • 2014
  • At present, the demand for electric power increases, the electric power system is complicated. The size of the line-to-ground fault and the line-to-line fault occurred with complication of electric power system continue to increase, therefore several issues are raised. To address these issues effectively, the superconducting fault current limiter (SFCL) has been proposed, this study is ongoing. In this paper, we applied the SFCL in three-phase transformer and comparative analysis of the electric power burden to the SFCL. The superconductor is combined to the third winding of transformers in connection structure. In case of a third line-to-line fault, we did comparative analysis of the electric power burden to the SFCL based on the turn ratio of transformer third winding. In this case, we could confirm as the third turn ratio increased, electric power impressed to the superconducting element increased.

Detection of Stator Winding Inter-Turn Short Circuit Faults in Permanent Magnet Synchronous Motors and Automatic Classification of Fault Severity via a Pattern Recognition System

  • CIRA, Ferhat;ARKAN, Muslum;GUMUS, Bilal
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.416-424
    • /
    • 2016
  • In this study, automatic detection of stator winding inter-turn short circuit fault (SWISCFs) in surface-mounted permanent magnet synchronous motors (SPMSMs) and automatic classification of fault severity via a pattern recognition system (PRS) are presented. In the case of a stator short circuit fault, performance losses become an important issue for SPMSMs. To detect stator winding short circuit faults automatically and to estimate the severity of the fault, an artificial neural network (ANN)-based PRS was used. It was found that the amplitude of the third harmonic of the current was the most distinctive characteristic for detecting the short circuit fault ratio of the SPMSM. To validate the proposed method, both simulation results and experimental results are presented.

A Study of On-line Monitoring System for a KEPCO Pumped Storage Generator/Motor

  • Kim Hee-Dong;Ju Young-Ho;Kim Yong-Joo;Cho Kyu-Bock
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.2
    • /
    • pp.90-95
    • /
    • 2006
  • An on-line diagnostic test has been studied and performed for the pumped storage generator/motor. This study aims at reducing the diagnostic cost, minimizing the technical dependency on third party manufactures. Further design of on-line diagnostic system such as shorted-turn of rotor winding, partial discharge (PD) of stator winding and air-gap between stator and rotor for pumped storage generator/motor has been verified. In addition, it needs to be validated on site performance of the developed continuous on-line monitoring system for corresponding tasks for the improvement of the availability & reliability during operation.

The Travelling Field of Two phase Linear Induction Motor (2상 Linear Induction Motor의 이동자계)

  • 이윤종;임달호
    • 전기의세계
    • /
    • v.19 no.1
    • /
    • pp.1-10
    • /
    • 1970
  • The foundation for the theoretical establishment of the linear motor lies in the investigation of the magnetic flux distribution in its airgaps. Generally speaking, the linear motor is similar, in the principle of its operation, to the general induction motor. However, there are great differences in the aspects of its structure and characteristics, especially, in the fact that the formation of its travelling magnetic field depends on the method of its winding. This paper is written in order to introduce the method of calculating the air gap magnetic flux distribution on the basis of its ampere-conductor in the case that 2 phase winding is applied on its open magnetic circuit iron core, and to present the results of investigation of the pulsation in its travelling fields. the first and second example of winding show the case of travelling magnetic field with the constant amplitude except the end region. The third example deals with the configuration of coil-side displaced outside the core and which produce the increased flux density at the ends, but, on the contrary, forms the pulsated travelling field.

  • PDF

Feature Extraction Technique for Insulation Fault of High Voltage Motor Stator Winding (고압전동기 고정자권선의 절연결함에 대한 특징추출기법)

  • Park Jae-Jun;Lee Sung-Young;Mun Dae-Chul
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.10
    • /
    • pp.976-983
    • /
    • 2006
  • Multi-resolution Signal Decomposition (MSD) Technique of Wavelet Transform has interesting properties of capturing the embedded horizontal, vertical and diagonal variations within an image in a separable form. This feature was exploited to identify individual partial discharge sources present in multi-source PD pattern, usually encountered during practical PD measurement. Employing the Daubechies wavelet, feature were extracted from the third level decomposed and reconstructed horizontal and vertical component images. These features were found to contain the necessary discriminating information corresponding to the individual PD sources and multi-PD soruces.

Phase transformer method and its application (위상변성방식과 그 응용)

  • 오상세
    • 전기의세계
    • /
    • v.13 no.2
    • /
    • pp.1-4
    • /
    • 1964
  • Phase transformation is used to change some phase from phase in A.C. system. We have been used Scott or Fork connection in phase transformation the otherwise phase transformation was constructed from M-G set. From this M-G set, we could make phase shift facilities by mannual. Now, I can derive more easy phase transformation from taking another method. I believe this new phase transformation method in the first thing in the world. And so, I am going to explain about phase transformer construction process. The first, we could devide into equal part of core around the iron core as to be same size. The second, you will make primary and secondary winding on the core. The third, when you will supplied three phase A.C. at the terminal of primary winding you can get e.m.f. inducing of some phase at secondary. And so, we could make phase change from some phase A.C. We can apply this principle in many fields, i.e., freequency changer, phase leader of no use condenser, voltage regulator in keeping balance, and D.C. generator. And more, I will introduce in details concerning main pinciple and theory through following chapter.

  • PDF

Analysis of Magnetic Field Application Effect on Fault Current Limiting Characteristics of a Flux-lock Type SFCL

  • Lim, Sung-Hun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.6
    • /
    • pp.255-259
    • /
    • 2008
  • The magnetic field application effect on resistance of a high-$T_c$ superconducting (HTSC) element comprising a flux-lock type superconducting fault current limiter (SFCL) was investigated. The YBCO thin film, which was etched into a meander line using a lithography, was used as a current limiting element of the flux-lock type SFCL. To increase the magnetic field applied into HTSC element, the capacitor was connected in series with a solenoid-type magnetic field coil installed in the third winding of the flux-lock type SFCL. There was no magnetic field application effect on the resistance of HTSC element despite the application of larger magnetic field into the HTSC element when a fault happened. The resistance of HTSC element, on the contrary, started to decrease at the point of four periods from a fault instant although the amplitude of the applied magnetic field increased.

Field Weakening Control for Five-Phase IPM Motor (Five-Phase IPM Motor의 약계자 제어)

  • Kim Nam-Hun;Kim Min-Huei;Baik Won-Sik;Hwang Don-Hwa;Kim Dong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.95-97
    • /
    • 2006
  • This paper investigates the field weakening operation of a five-phase IPMSM(inner permanent magnet synchronous motor). The five-phase motor can supply sinusoidal voltage and third harmonic voltage because of more freedom of control. This paper present field weakening algorithm and experimental results for five-phase IPMSM which has trapzoidal back-EMF and concentrate winding to prove the validity of the proposed algorithm.

  • PDF

Analysis and Design of a PFC AC-DC Converter with Electrical Isolation

  • Lin, Chia-Ching;Yang, Lung-Sheng;Zheng, Ren-Jun
    • Journal of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.874-881
    • /
    • 2014
  • This study presents a single-phase power factor correction AC-DC converter that operates in discontinuous conduction mode. This converter uses the pulse-width modulation technique to achieve almost unity power factor and low total harmonic distortion of input current for universal input voltage $90V_{rms}$ to $264V_{rms}$) applications. The converter has a simple structure and electrical isolation. The magnetizing-inductor energy of the transformer can be recycled to the output without an additional third winding. The steady-state analysis of voltage gain and boundary operating conditions are discussed in detail. Finally, experimental results are shown to verify the performance of the proposed converter.