• Title/Summary/Keyword: Third Electrode

Search Result 71, Processing Time 0.029 seconds

The Effects of Constant Direct Current on the New Bone Formation of Fractured Fibula in Rabbits (지속적인 직류자극이 토끼 비골 골절의 신생골 형성에 미치는 영향)

  • Chung Hyung-Kuk;Kim Jin-Sang;Park Rae-Joon
    • The Journal of Korean Physical Therapy
    • /
    • v.6 no.1
    • /
    • pp.95-107
    • /
    • 1994
  • This study was performed to identify the effect of constant direct current and to give us methods which can be applied easily in clinic. Six rabbits was used at this experiment. After each animal was fractured at left fibula, divided into experimental group(n=3) and central group(n=3). Experiment duration of electrical stimulation on experimental rabbits was 35 days. Direct current from fifteen microampere to twenty microampere was passed continously through the placed electrode between fracture area and thigh. Negative electrode was placed at fracture area and positive at thigh. Roentgenography was used to observe bone-healing progression wet three times-at 15days, 25days and 35days after electrical stimulation. The results obtained are as followings: 1. Both experimental group and control group do not obtain callus formation on the first roentgenography(15 days after ES). 2. On the second roentgenography(25 days after ES), experimental group achieves above $70\%$ on fracture-healing, but control group achieves about $20-30\%$ on fracture healing. 3. On the third roentgenegraphy(35 nays after ES), experimental group achieves above $85-95\%$ on fracture healing and control group achieves about $60-70\%$ of bone union. Thus, statistically significance(independent t-test) was occured ie the second and third roentgenography between experimental group and control group.

  • PDF

Adhesion of Cu/Interlayer/Polyimide Flexible Copper Clad Laminate Depending on the Ni-Cr-X Interlayers

  • Kim, Si Myeong;Jo, Yoo Shin;Kim, Sung June;Kim, Sang Ho
    • Journal of Surface Science and Engineering
    • /
    • v.50 no.3
    • /
    • pp.164-169
    • /
    • 2017
  • Ni-Cr-X ternary interlayers were investigated to improve the adhesion of Cu/Ni-Cr/Polyimide flexible copper clad laminates. The ternary compounds are sputtered Ni-Cr-X films (where X is one of Nb, V, Mo, or Ti), and the effect of third elements on the adhesion was evaluated and investigated chemically and mechanically. The feel strength was higher in the order of Ni-Cr-Nb > Ni-Cr-V > Ni-Cr > Ni-Cr-Mo > Ni-Cr-Ti. Nb, which has a comparable standard electrode potential to Cr, increased the adhesion, while Ti, with a low standard electrode potential, degraded the adhesion. The Ni-Cr-Nb interlayer was amorphous, while Ni-Cr-Ti was partially crystalline. The similar morphology structure of the Ni-Cr-Nb interlayer with polyimide resulted in a better adhesion.

The Properties of Low Hydrogen Content α-Si Thin Film Using DC-bias Enhanced or Addition of H2Gas in Mesh-type PECVD System (Mesh-type PECVD를 이용한 DC-bias인가 및 수소가스 첨가에 따른 저수소화 비정질 실리콘 박막에 관한 연구)

  • Ryu, Se-Won;Gwon, Do-Hyeon;Park, Seong-Gye;Nam, Seung-Ui;Kim, Hyeong-Jun
    • Korean Journal of Materials Research
    • /
    • v.12 no.4
    • /
    • pp.235-239
    • /
    • 2002
  • In this study mesh-type PECVD system was suggested to minimize the hydrogen concentration. The main structural difference between the triode system and a conventional system is that, a third electrode, a mesh, is inserted between the powered and the ground electrode. We investigated several conditions to compare with conventional PECVD. The main effect of mesh was to minimize the substrate damage by ion bombardment and to enhance the surface reaction to induce hydrogen desorption. It was also found that hydrogen concentration decreased but deposition rate increased as increasing applied bias. Applied DC-bia s enhanced sputtering process. Intense ion bombardment causes the weakly bonded hydrogen or hydrogen-containing species to leave the growing film and increased adatom mobility. Furthermore, addition of hydrogen gas enhance the surface diffusion of adatom.

Electrical Properties of p-GaAs Photoelectrode for Solar Energy Conversion (태양광 변환을 위한 p형 GaAs 광전극의 전기적 특성)

  • 윤기현;이정원;강동헌
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.11
    • /
    • pp.1262-1268
    • /
    • 1995
  • Photoelectrochemical properties of p-GaAs electrode have been investigated. I-V characteristic shows that the cathodic photocurrent is observed at -0.7 V vs. SCE. The photoresponse at near 870~880nm wavelength indicates that the photogenerated carriers contibuted to the observed current. The maximum converson efficiency of 35% is obtained for a Xe lamp light source at 400nm. In C-V relation, capacitance peaks appeared at the frequencies of 100Hz and 300Hz due to the activation of the interfacial states which exist at the energy level corresponding to the one-third of the GaAs band gap. The difference of about 1.1V between flatband potential (Vfb) from the Mott-Schottky method and onset voltage from I-V curve is observed due to the trap of carriers at the interfacial states in the boundary between GaAs and electrolyte. In case of WO3 deposited p-GaAs electrode, higher positive onset current and photocurent density are obtained. This can be explained by the fact that carriers are generated by light penetrated into the WO3 thin flm as well as p-GaAs substrate and then move into the electrolyte effectively.

  • PDF

The Mobile Health-Care Garment System for Measurement of Cardiorespiratory Signal (ECG와 호흡 측정이 가능한 모바일 헬스케어 의류 시스템)

  • Kim, Jeong-Do;Kim, Kap-Jin;Chung, Gi-Su;Lee, Jung-Hwan;Ahn, Jin-Ho;Lee, Sang-Goog
    • The KIPS Transactions:PartA
    • /
    • v.17A no.3
    • /
    • pp.145-152
    • /
    • 2010
  • Most wearable system for mobile healthcare applications consists of three parts. The first part is the sensing elements based on bio-signal, the second is the circuit module for control, data acquisition and wireless communication and control and the third is garment with a built-in electrodes and circuits. The existing healthcare garment systems have to find a solution to signal-wire and uncomfortable and inappropriate electrode to long-term attachment. Even if the wireless communication is used for healthcare garment system, the interface between sensors and circuits have to use wires. To solve these problems, this paper use electrode using PEDOT coated PVDF nanoweb for ECG signal and PVDF film sensor for respiratory signal. And, we constructed garment network using digital yarn of 10um, and transmitted ECG and respiratory signal to mobile phone through the integrated circuit with bluetooth called station To evaluate feasibility of the proposed mobile healthcare garment system, we experimented with transmission and measurement of ECG and respiratory signal using nanoweb electrode and digital yarn. We got a successful result without noise and attenuation.

$3^{rd}$ Overtone Mode Energy-Trapped Filter Using $PbTiO_{3}$ System Ceramics ($PbTiO_{3}$계 조성 세라믹스를 이용한 3차 진동모드 에너지 트랩형 필터에 관한 연구)

  • Oh, Dong-On;Yoo, Ju-Hyun;Park, Chang-Yub;Yoon, Hyun-Sang;Lee, Su-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.83-86
    • /
    • 2002
  • In this paper, $3^{rd}$ overtone mode energy-trapped filter using modified $PbTiO_3$ system ceramics was manufactured to apply for intermediate frequency SMD-type filter with the variations of splitted electrode size. To investigate the effects of splitted electrode size on filter characteristics of $3^{rd}$ overtone mode energy-trapped filter, ceramic wafers were fabricated by etching splitted rectangular electrode size($b{\times}d$) of b=0.4, 0.6, 0.8, 1mm, d=0.3, 0.4, 0.5mm, respectively. And then, SMD-type ceramic filter were fabricated with the size of $3.7{\times}3.1mm$. With the variations of b size, insertion loss, 3dB bandwidth and 25dB stop bandwidth showed nearly constant value, but with the variations of d size, insertion loss, 3dB bandwidth, selectivity(shape factor) decreased.⨀؀က?⨀Ⴣ?⨀਀Ⴣ?⨀ꞻꎀ̀ကꮻꎀༀ뮻ꎀ᠀Ȁ햻ꎀĀힻꎀȀ?ꎀ̀?ꎀȀꎀĀꎀĀꎀĀꎀĀꎀЀȀꎀࠀꎀഀڼꎀഀᒼꎀ؀ᮼꎀ䈀ȀȀ悼ꎀऀ檼ꎀഀȀ禼ꎀഀ螼ꎀऀȀȀ鎼ꎀഀȀꊼꎀഀ낼ꎀࠀ즼ꎀԀ쾼ꎀ܀ힼꎀ

  • PDF

Effect of Different Front Metal Design on Efficiency Affected by Series Resistance and Short Circuit Current Density in Crystalline Silicon Solar Cell (결정질 실리콘 태양전지의 전면 전극의 패턴에 따른 전류 밀도 및 특성 저항 변화에 대한 영향과 효율 변화)

  • Jeong, Sujeong;Shin, Seunghyun;Choi, Dongjin;Bae, Soohyun;Kang, Yoonmook;Lee, Hae-seok;Kim, Donghwan
    • Korean Journal of Materials Research
    • /
    • v.27 no.10
    • /
    • pp.518-523
    • /
    • 2017
  • In commercial solar cells, the pattern of the front electrode is critical to effectively assemble the photo generated current. The power loss in solar cells caused by the front electrode was categorized as four types. First, losses due to the metallic resistance of the electrode. Second, losses due to the contact resistance of the electrode and emitter. Third, losses due to the emitter resistance when current flows through the emitter. Fourth, losses due to the shading effect of the front metal electrode, which has a high reflectance. In this paper, optimizing the number of finger on a $4{\times}4$ solar cell is demonstrated with known theory. We compared the short circuit current density and fill factor to evaluate the power loss from the front metal contact calculation result. By experiment, the short circuit current density($J_{sc}$), taken in each pattern as 37.61, 37.53, and $37.38mA/cm^2$ decreased as the number of fingers increased. The fill factor(FF), measured in each pattern as 0.7745, 0.7782 and 0.7843 increased as number of fingers increased. The results suggested that the efficiency(Eff) was measured in each pattern as 17.51, 17.81, and 17.84 %. Throughout this study, the short-circuit current densities($J_{sc}$) and fill factor(FF) varied according to the number of fingers in the front metal pattern. The effects on the efficiency of the two factors were also investigated.

Electromyographic studies on the masseter and temporal muscles during exchange of the deciduous teeth (유치 교환기의 교근 및 측두근의 근전도 연구)

  • Lee, Jong-Heun
    • The Korean Journal of Physiology
    • /
    • v.3 no.1
    • /
    • pp.33-44
    • /
    • 1969
  • Electoromyographic studies were performed on the action of the muscles of the temporomandibular joints following exfoliation of the deciduous teeth. The subjects examined, being 50 children. between the age of 6 and 13 years, divided into 5 groups. They were; 1) Deciduous dentition were complete in the first group. 2) Deciduous incisors were missing in either upper or lower jaw in the second group. 3) Deciduous canine and molars were missing in the left side of either upper or lower jaw in the third group. 4) Deciduous canine and molars were missing in the right side of either upper or lower jaw in the fourth group. 5) Permanent dentition completed in the fifth group(except third molars). Electromyogram was recorded with 4 channel polygraph (Grass model VII modified for 7P3). Electrodes which were the cup-typed gold discs, 9 millimeters in the diameter, were located on the anterior, middle and posterior lobes of the temporal muscles, and also on the superficial and deep layers of the masseter muscles. Paired electrodes were held by electrode cream so that they were pressed on the skin surface at right angle, adhesive tape being used to anchor them. The distance of the pair electrodes was about 5 millimeters. The results obtained were as follow: 1) In rest position of mandible; All groups showed slight, electrical activities in the muscles involved, but in the middle lobe of temporal muscle they were slightly higher. 2) In molar occlusion of mandible; High activity-anterior lobe of temporal muscle and superficial layer of masseter muscle. Moderate activity-deep layer of masseter muscle. Low activity-middle and posterior lobes of masseter muscle. There were no differences among the first, the second and the fifth groups. In the third group the muscle activity was weaker than that of the right, and in the fourth group opposite characteristics was revealed. 3) In incisal bite of mandreble; Hight activity-superficial layer of masseter muscle. Modertae activity-deep layer of masseter muscle. Low activity-anterior, middle and posterior lobes of temporal muscle. The first, the third, the fourth and the fifth groups showed no differences but the second group showed less activity than those of others. 4) In protrusion of mandible; High activity-deep layer of masseter muscle Moderate activity-superficial layer of masseter muscle. Low activity-anterior, middle and posterior lobes of temporal muscle. In the first, the fourth and the fifth groups, there were no differences in the activities, but the second group showed less activity than the others. 5) In retrusion of mandible; High activity-deep layer of masseter muscle. Moderate activity-superficial layer of masseter muscle. Low activity-anterior, middle and posterior lobes of temporal muscle. In the first, the third, the fourth and the fifth groups, there were no differences but the second group showed less activity than the others. 6) In lateral excursion of the mandible (either direction); High activity-posterior lobe of temporal muscle. Moderate activity-anterior and middle lobes of temporal muscle. Low activity-superficial and deep layers of masseter muscle. The muscle action potentials were weaker than those of the right side in the third group and vice ver'sa in the fourth group. 7) In chewing movement; Temporal muscle activities were higher than those of masseter, especially in the middle lobe of temporal muscle the activity was highest. Right side muscle activities were higher than those of the left in the third group and, on the contrary, the left side was dominant over the right in the fourth group.

  • PDF

Reliability Evaluation of STD-11 Cutting Surface on the Machined Condition using the Back-Propagation Neural Network (역전파 신경회로망을 이용한 가공조건에 따른 STD-11 절단면의 신뢰성 평가)

  • Kim Sun-Jin;Sung Back-Sub;Cho Gyu-Jae;Kim Ha-Sik;Ban Jae-Sam
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.5
    • /
    • pp.7-15
    • /
    • 2004
  • The purpose of this study was to present the method to choose the optimum machining condition for the wire EDM. This was completed by examining the ever-changing quality of the material and by improving the function of the wire electric discharge machine. Precision metal mold products and the unmanned wire electric discharge machining system were used and then applied in industrial fields. This experiment uses the wire electric discharge machine with brass wire electrode of 0.25mm. To measure the precision of the machining surface, average values are obtained from 3 samples of measures of center-line average roughness by using a third dimension gauge and a stylus surface roughness gauge.

Magnetic Field Analysis of the Electrode Arc Furnace in Steel Making Foundries

  • Kim, C.W.;Im, J.I.
    • Journal of Magnetics
    • /
    • v.8 no.2
    • /
    • pp.79-84
    • /
    • 2003
  • Finite element analysis showed that strong magnetic fields were distributed around the arc furnace where the strongest magnetic fields were generated around the three phase cables. The second and third strongest fields near the arc furnace were found to be generated around the electrodes and the mast-arms, respectively. The generated field intensities were greatly influenced by the mast arm structure of the arc furnace as well as the phase differences and operation currents of the supplied power, Magnetic field decay patterns around the arc furnace could be smoothly fitted by this equation of exponential formula, H=H$0_$+Ae$^{\frac{r}{t}}$. These results revealed that magnetic field intensities around the arc furnace could be estimated at any 3-dimensional position using finite element method (FEM).