• Title/Summary/Keyword: Thin-Film

Search Result 11,251, Processing Time 0.037 seconds

Surface Modification of Polystyrene (PS) by Atmospheric Pressure Plasma (상압 플라즈마를 이용한 Polystyrene (PS)의 표면개절)

  • Lee, Jong-Su;Shin, Hyun-Seok;Seok, Jin-Woo;Jang, Gyu-Wan;Beag, Yeong-Hwan
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • Hydrophilic Surface modification of Polysarene (PS) was performed by Atmospheric Pressure Plasma (APP). Air or 0, gases were used for carrier gases and RF power was changed from 150 to 350 W. We controlled the treatment time as 1 time to 4 time passing through the plasma region. when the carrier gas was air, the water contact angle on the PS surface was decreased from $91^{\circ}$ to $20^{\circ}$. And the surface energy increased from 45.74 dyne/cm to 68.48 dyne/cm. In case of the $O_2$ plasma treatment, at 300 W of RF power and 4 times treatment, the water contact angle on the PS. Surface was decreased from $91^{\circ}$ to $17^{\circ}$ and the surface energy was increased from 45.74 dyne/cm to 69.73 dyne/cm. The surface energy was increased by polar force not by dispersion force. Improvement of surface properties can be explained by the formation of new hydrophilic groups which is identified as C-O, C=O by XPS analysis. The contact angle of APP treated PS surface kept in air was increased with time elapse, but maintained same value when it was kept in water. We treated the PS surface by APP and deposited Cu as $4,000\;{\AA}$ and $8,000\;{\AA}$ by thermal evaporation. The adhesion between sample and Cu thin film improvement of treated PS surface against untreated sample. could be verifiable by Tape test (ASTM D3359)

Thermal Stability of Ti-Si-N as a Diffusion Barrier (Cu와 Si간의 확산방지막으로서의 Ti-Si-N에 관한 연구)

  • O, Jun-Hwan;Lee, Jong-Mu
    • Korean Journal of Materials Research
    • /
    • v.11 no.3
    • /
    • pp.215-220
    • /
    • 2001
  • Amorphous Ti-Si-N films of approximately 200 and 650 thickness were reactively sputtered on Si wafers using a dc magnetron sputtering system at various $N_2$/Ar flow ratios. Their barrier properties between Cu (750 ) and Si were investigated by using sheet resistance measurements, XRD, SEM, RBS, and AES depth profiling focused on the effect of the nitrogen content in Ti-Si-N thin film on the Ti-Si-N barrier properties. As the nitrogen content increases, first the failure temperature tends to increase up to 46 % and then decrease. Barrier failure seems to occur by the diffusion of Cu into the Si substrate to form Cu$_3$Si, since no other X- ray diffraction intensity peak (for example, that for titanium silicide) than Cu and Cu$_3$Si Peaks appears up to 80$0^{\circ}C$. The optimal composition of Ti-Si-N in this study is $Ti_{29}$Si$_{25}$N$_{46}$. The failure temperatures of the $Ti_{29}$Si$_{25}$N$_{465}$ barrier layers 200 and 650 thick are 650 and $700^{\circ}C$, respectively.ely.

  • PDF

Development and Performance Evaluation of Anti-cavitation Paint with a Lamella Glass-flake (판상형 Glass-flake를 이용한 내캐비테이션 도료 개발 및 성능평가)

  • Park, Hyeyoung;Kim, Sung-gil;Kim, Sang-suk;Choi, I-chan;Kim, Byungwoo;Kim, Seung-jin
    • Korean Chemical Engineering Research
    • /
    • v.54 no.2
    • /
    • pp.145-151
    • /
    • 2016
  • In response to the cavitation caused by the partial vacuum caused by the fluid flow, a paint was developed by dispersing the lamella-shaped glass-flake in resin for anti-cavitation. This composite paint was developed by using the inorganic filler (lamella shaped glass-flake) and the NBR (Acrylonitrile-butadiene rubber) which was modified epoxy resin. Especially, the glass-flake was a thin film with a thickness of about 100~200 nm and length of about $20{\sim}30{\mu}m$, the aspect ratio was about 200 to 300 times that of the plate-shaped. So the paint for anti-cavitation have shown excellent performance in corrosion resistance. The results of evaluating anti-cavitation performance was below, tensile strength $4.8{\sim}6N/mm^2$ or more, rupture elongation 30% or higher, abrasive speed $10mm^2/h$ or less. In particular, it showed more than twice the superior performance compared to existing advanced foreign products in anti-cavitation performance evaluation.

Generation of Testability on High Density /Speed ATM MCM and Its Library Build-up using BCB Thin Film Substrate (고속/고집적 ATM Switching MCM 구현을 위한 설계 Library 구축 밀 시험성 확보)

  • 김승곤;지성근;우준환;임성완
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.6 no.2
    • /
    • pp.37-43
    • /
    • 1999
  • Modules of the system that requires large capacity and high-speed information processing are implemented in the form of MCM that allows high-speed data processing, high density circuit integration and widely applied to such fields as ATM, GPS and PCS. Hence we developed the ATM switching module that is consisted of three chips and 2.48 Gbps data throughput, in the form of 10 multi-layer by Cu/Photo-BCB and 491pin PBGA which size is $48 \times 48 \textrm {mm}^2$. hnologies required for the development of the MCM includes extracting parameters for designing the substrate/package through the interconnect characterization to implement the high-speed characteristics, thermal management at the high-density MCM, and the generation of the testability that is one of the most difficult issues for developing the MCM. For the development of the ATM Switching MCM, we extracted signaling delay, via characteristics and crosstalk parameters through the interconnect characterization on the MCM-D. For the thermal management of 15.6 Watt under the high-density structure, we carried out the thermal analysis. formed 1.108 thermal vias through the substrate, and performed heat-proofing processing for the entire package so that it can keep the temperature less than $85^{\circ}C$. Lastly, in order to ensure the testability, we verified the substrate through fine pitch probing and applied the Boundary Scan Test (BST) for verifying the complex packaging/assembling processes, through which we developed an efficient and cost-effective product.

  • PDF

growth of Cadmium Sulfide (CdS) Thin Film by Solution Growth Technique and Study of Quantum Size Effects (용액성장법에 의한 Cadmium Sulfide(CdS) 박막 성장 및 양자 사이즈 효과에 관한 연구)

  • 임상철
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.4 no.1
    • /
    • pp.1-12
    • /
    • 1997
  • 본 연구에서는 용액성장법에 의해 양자 입자로 구성된 CdS 박막을 슬라이드 유리기 판위에 성장시키고 이들의 구조적 광학적 특성에 대하여 연구하였고 이들 결과를 토대로 용 액성장법으로 성장된 CdS 박막의 양자 사이즈 효과에 대하여 연구하였다. 성장시간은 1, 3, 10, 20분이었고 성장온도는 75$^{\circ}C$였다. X-선 회절 분석결과 본 연구에서 합성된 CdS 박막은 hexagonal상의 결정구조를 갖는 것으로 나타났고 성장시간에 따라 막의 투께는 61~195nm, 입자사이즈는 8.5~22.5nm로 나타났다. 광에너지 변화에 따른 투과도 측정결과 본 연구의 CdS 시료는 성장시간에 따라 에너지 밴드갭이 2.43~2.51 eV로 나타나서 벌크 CdS의 에너 지 밴드갭인 2.42 ev보다 높은 에너지 밴드갭을 갖게 되어 양자 사이즈 효과에 의한 blue shift 현상이 용액성장법에 의해 합성된 CdS 시료에도 존재한다는 것이 밝혀졌다 그리고 이 같은 용액성장법으로 성장된 CdS에 대해 최초로 수행된 Raman 산란 실험결과 이성장방법 으로 성장된 CdS에는 1TO, E2, 1LO 포논 모드가 존재함을 알수 있었고 또한 입자 사이즈 감소에 의한 1LO포논 모드의저주파수 shift 현상 즉 포논 모드의 softening 현상이 있음이 밝혀졌고 softening은 최대6.2%까지 발생하였다. 이와같은 높은 softening은 본연구의 CdS 박막 내 양자 입자의 입도가 작은것에 기인하는 것으로 밝혀졌다. 또한 본 CdS 시료의 양 자 사이즈 효과의 결과로 1TO 포논도 나타났는데 이 1TO 포논과 E2 포논의 Raman shift 는 성장시간 즉 막의 두께와는 무관한 것으로 나타났다.행렬모형(二重比例行列模型)을 이용하여, 산업구조의 변화로 인한 직업별 인력수요 변화가 충분히 고려되도록 하였다. 전망의 결과에 따르면 향후 우리 경제는 지식기반경제(knowledge-based economy)로 이행하고 있다고 볼 수 있다. 우선 산업구조면에서 지식집약적산업으로의 구조조정이 일어나게 되고 이에 따라 산업별 취업구조에서도 고기술산업의 취업준비중이 급속히 증가하게 된다. 직업별 취업분포에 있어서도 전문기술직 행정관리직 등의 고숙련 사무직의 비중은 크게 증가하는 반면 생산관련직과 농림어업직의 비중은 감소하게 된다. 이처럼 경제가 지식집약화되어 감에 따라 고학력자에 대한 수요는 지속적으로 증가하지만 현재 적절한 인력양성과 공급이 이루어지지 않고 있어 향후 기술이나 기능에 따른 수급부일정(需給不一政)(skill mismatch)현상이 매우 심해질 것으로 보인다. 따라서 앞으로의 인력정책에서 가장 주안점을 두어야 할 부분은 첨단기술산업과 관련된 인력의 양성에 있다고 하겠다.2시간까지 LPDG용액은 MEC용액보다 비교적 나은 회복을 보였고 재관류 3일과 7일의 폐기능 평가에서 두 용액 모두에서 폐기능의 점차적 소실을 보였으며 이는 병리조직검사에서 보듯이 폐혐에 의한 외적인 요소라고 생각되며 따라서 LPDG용액은 허혈재관류손상 방지 및 급성폐렴 등 염증을 잘 관리한다면 20시간 이상 LPDG용액의 안전한 폐보존의 가능성 을 얻을 수 있었다.ic 형태로 외래유전자가 발현되었지만 대조구에서 87.0% (26/30개) 배반포기가 $\beta$-Gal 활력을 보인 반면, G418 처리구에서는 모든 배반포기가 $\beta$-Gal 활력을 보였다 (P<0.05). 그러나 대조구 및 G418 처리구의 ICM

Graphoepitaxy of ZnO thin films by Zn evaporation (Graphoepitaxy법을 이용하여 SiO$_2$ 기판 위에 제작한 ZnO 박막의 특성에 관한 연구)

  • Kim, Gwang-Hui;Choi, Seok-Cheol;Lee, Tae-Hun;Jung, Jin-U;Park, Seung-Hwan;Jung, Mi-Na;Jung, Myeong-Hun;Yang, Min;Yao, Takafumi;Chang, Ji-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.1
    • /
    • pp.1026-1029
    • /
    • 2005
  • The feasibility of graphoepitaxial growth of compound semiconductors has been studied. Two kinds of substrates were prepared; one is smooth substrate, the other one is a periodic structured substrate. ZnO film was formed on both substrates by thermal evaporation of elemental Zn and natural oxidation of the deposited Zn. Thermal treatment was performed to improve the crystal quality and to investigate the effect of the periodic structure. Atomic force microscopy (AFM) and photoluminescence (PL) were used to characterize the samples. As a result, the improvement of crystallinity as annealing temperature increase, has been observed from both samples. The samples, annealed at 800 $^{\circ}$C, show the best crystal quality in terms of PL linewidth. Also the sample grown on grating structure shows better crystal quality than the sample grown on flat substrate. It implies that the periodic structure affects the crystallinity of the films, and the graphoepitaxy of compound semiconductors is possible by using appropriate surface structure.

  • PDF

Electrical Properties of Al3+ and Y3+ Co-doped SnO2 Transparent Conducting Films (Al3+와 Y3+ 동시치환 SnO2 투명전극 박막의 전기적 특성)

  • Kim, Geun-Woo;Seo, Yong-Jun;Sung, Chang-Hoon;Park, Keun-Young;Cho, Ho-Je;Heo, Si-Nae;Koo, Bon-Heun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.10
    • /
    • pp.805-810
    • /
    • 2012
  • Transparent conducting oxides (TCOs) have wide range of application areas in transparent electrode for display devices, Transparent coating for solar energy heat mirrors, and electromagnetic wave shield. $SnO_2$ is intrinsically an n-type semiconductor due to oxygen deficiencies and has a high energy-band gap more than 3.5 eV. It is known as a transparent conducting oxide because of its low resistivity of $10^{-3}{\Omega}{\cdot}cm$ and high transmittance over 90% in visible region. In this study, co-doping effects of Al and Y on the properties of $SnO_2$ were investigated. The addition of Y in $SnO_2$ was tried to create oxygen vacancies that increase the diffusivity of oxygen ions for the densification of $SnO_2$. The addition of Al was expected to increase the electron concentration. Once, we observed solubility limit of $SnO_2$ single-doped with Al and Y. $\{(x/2)Al_2O_3+(x/2)Y_2O_3\}-SnO_2$ was used for the source of Al and Y to prevent the evaporation of $Al_2O_3$ and for the charge compensation. And we observed the valence changes of aluminium oxide because generally reported of valence changes of aluminium oxide in Tin - Aluminium binary system. The electrical properties, solubility limit, densification and microstructure of $SnO_2$ co-doped with Al and Y will be discussed.

Regional Differences of Entry Rate of Freely Diffusible Substances from Peritoneal Cavity (복강내 확산성 물질의 부위별 흡수속도)

  • Cho, Byeong-Deuck;Shin, Dong-Hoon
    • The Korean Journal of Physiology
    • /
    • v.1 no.2
    • /
    • pp.157-168
    • /
    • 1967
  • The entry of antipyrine and urea from the peritoneal cavity of rabbit into organ tissue and blood plasma was studied. Two hundred mg of antipyrine plus 300 mg of urea in 10 ml Ringer's solution was injected into the peritoneal cavity of anesthetized rabbit. The injection was made from above of a rabbit kept tying right side down and it enabled part of the abdominal organs (liver, intestine, kidney) was immersed in the injected solution and kept high concentration gradient throughout the experimental period. The remaining part of the organs was revered only by a thin film of the test solution. Subsequently, in this part of the organs the concentration gradient of the diffusible substances during entry was presumed to decrease as time elapsed. Four pieces of the liver tissue were taken namely, the right superficial, right deep, left superficial and left deep portions. Two were taken from the small intestine, one from the portion which was immersed in. the fluid and the other from that above the fluid mass. Both kidneys were separately analyzed. As a remote organ the gastrocnemius muscle was taken from the right leg of the animal. The intervals which were the time periods elapsed after injections were 5,7,10,15 or 30 minutes. At each point 5 animals were sacrificed and the concentrations of the test substances in the tissue water were measured. The results obtained were as follows. 1. In the liver the right portion which was immersed in the fluid showed higher concentration if the test substances than the left portion and the superficial region exceeded the deep region. The concentrations diminished as the time elapsed after infusion, particulary in the case of antipyrine, suggesting circulatory removal of the substances. In urea such decreasing tendency of the concentration was not obvious, and suggested slower removal rate of it as compared with that of antipyrine. 2. In the small intestine there was no regional difference in the concentration of the test substances. Because of the intestinal motility different portions of the intestine were seemed to have bathed in the fluid of the same concentration. In general the concentrations in the intestinal wall exceeded those of the liver, suggesting a slower removal rate than in the latter. 3. In the kidney the accumulation of the endogenous urea was predominant, and the accumulating mechanism in the renal tissue went on during the period of the experiment. Therefore it revealed increasing tendencies as the time elapsed. The penetration of the test substances in this organ from the peritoneal cavity seemed to be slower than in other abdominal organs, namely liver or small intestine. Part of the test substances in the kidney were obviously brought by the blood stream. 4. Rapid exponential decay of the concentration of antipyrine and of the osmolality of the peritoneal fluid was attributed to the extensive removal through the whole dimension of the peritoneal surface, and the remote organ such as the gastrocnemius muscle attained a fairly close value to that of the abdominal organs in less than 30 minutes. The factors which related to the absorption rate were discussed. They were the concentration gradient, permeability and the regional perfusion rate.

  • PDF

Effect of X-ray Irradiation on the Pulmonary Surfactant in Rabbits (흉부(胸部) X-선조사(線照射)가 가토폐포(家兎肺胞) 표면활성물질(表面活性物質)에 미치는 영향(影響))

  • Lee, Chull
    • The Korean Journal of Physiology
    • /
    • v.2 no.2
    • /
    • pp.63-73
    • /
    • 1968
  • It is well known that mammalian alveolar membrane is covered with a very thin layer of surfactant film which characteristically reduces surface tension of alveolar membrane, and maintains alveolar stability. Since Clements in 1957 demonstrated that the surfactant is extractable by mincing the lung tissue in saline, various studies on the subject have been succeeded by many workers. However, the effect of radiation on the surfactant is not well clarified. Present study was attempted to observe the effect of x-irradiation on the activity of surfactant in rabbits. X-ray in dose of 300 r, 600 r or 900 r was irradiated to the chest of rabbits. The lung was removed from normal or irradiated rabbits sacrificed by arterial blood shedding, and lung-saline extract, adding 3 grams of lung tissue to 50 mili-liters of saline, was prepared by means of Vertis homogenizer. Tension-area diagram of lung extract was recorded automatically by a modified Langmuir-Wilhelmy balance with a synchronized recording system designed in this department. The surface tension of lung extract was measured at 1st, 2 nd, 3 rd, 7 th and 15 th post-radiation day in 300 r irradiated group, at 3 rd, 7 th and 15 th post-radiation day in 600 r irradiated group, 3 rd and 7 th post-radiation day in 900 r irradiated group respectively. For the histo-pathological study, lung tissue preparations were made in all irradiatiated groups on the day of experiment and in normal group. The results obtained are summarized as follows: 1. The minimal surface tension, maximal surface tension and stability index of normal rabbits lung extracts were 7.68 dynes/cm, 38.84 dynes/cm, and 1.39 respectively. 2. The activity of surfactant was depressed prominently by x-irradiation. However, increase in the dose of x-irradiation did not show any significant change in the degree of surfactant activity suppression. The most marked depression in surfactant was observed at the third post-radiation day in all irradiated groups. 3. Activity of surfactant depressed by x-irradiation showed a tendency of recovering to normal on 15 th post-radiation day. 4. The tendency of change in activity of surfactant following x-irradiation was somewhat correlative with histo-pathological changes. But the degree of depression of surfactant by x-irradiation did not correspond to the degree of histo-pathological changes, and recovery of lung tissue from radiation damage, tissue edema and congestion, seemed to be followed by restoration of surfactant activity. 5. The width of the tension-area diagram was measured at the surface area of 40% in lung extract of normal and x-irradiated rabbits. And it was found that the changes of the width corresponded well with that of minimum surface tension and of stability index in all normal and x-irradiated groups.

  • PDF

Characteristics of Constructed SPR (Surface Plasmon Resonance) Sensor System for the Detection of Salmonella and hIgG Antigen-Antibody Reaction. (살모넬라와 면역글로블린(hIgG)의 항원-항체반응 감지를 위한 표면 플라즈몬 공명형 센서시스템의 특성)

  • Um, N.S.;Koh, K.N.;Hahm, S.H.;Kim, J.H.;Lee, S.H.;Kang, S.W.
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.263-270
    • /
    • 1998
  • Surface Plasmon Resonance (SPR) sensor system, has rapid response and high sensitivity, can be applicable for detecting reaction times of many biospecific interactions. A SPR sensor system was constructed to detect the antigen-antibody reactions of salmonella and hIgG (human immunoglobulin G). Sensor chips made of gold thin film were used for detecting biological bindings of antigen and antibody reactions. The antigen and antibody reactions for salmonella and hIgG were carried out with various time intervals to observed characteristics of these reactions using SPR sensor system. The resonance angle shift changes were clearly observed at the time of salmonella or hIgG antibody injection into sample cell since each antibody was self-assembled on gold chip surface of the sensor. It was found that the antibodies of salmonella and hIgG reacted with its sensor chip surface in 10 minutes and 60 minutes respectively. And the antigens of both salmonella and hIgG were bound to its antibody within 1 minute.

  • PDF