• Title/Summary/Keyword: Thin films

Search Result 9,529, Processing Time 0.04 seconds

Optical Property of Super-RENS Optical Recording Ge2Sb2Te5 Thin Films at High Temperature (초해상 광기록 Ge2Sb2Te5 박막의 고온광물성 연구)

  • Li, Xue-Zhe;Choi, Joong-Kyu;Lee, Jae-Heun;Byun, Young-Sup;Ryu, Jang-Wi;Kim, Sang-Youl;Kim, Soo-Kyung
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.5
    • /
    • pp.351-361
    • /
    • 2007
  • The samples composed of a GST thin film and the protective layers of $ZnS-SiO_2$ or $Al_2O_3$ coated on c-Si substrate were prepared by using the magnetron sputtering method. Samples of three different structures were prepared, that is, i) the GST single film on c-Si substrate, ii) the GST film sandwiched by the protective $ZnS-SiO_2$ layers on c-Si substrate, and iii) the GST film sandwiched by $Al_2O_3$ protective layers on c-Si substrate. The ellipsometric constants in the temperature range from room temperature to $700^{\circ}C$ were obtained by using the in-situ ellipsometer equipped with a conventional heating chamber. The measured ellipsometric constants show strong variations versus temperature. The variation of ellipsometric constants at the temperature region higher than $300^{\circ}C$ shows different behaviors as the ambient medium is changed from in air to in vacuum or the protective layers are changed from $ZnS-SiO_2$ to $Al_2O_3$. Since the long heating time of 1-2 hours is believed to be the origin of the high temperature variation of ellipsometric constants upon the heating environment and the protective layers, a PRAM (Phase-Change Random Access Memory) recorder is introduced to reduce the heating time drastically. By using the PRAM recorder, the GST samples are heated up to $700^{\circ}C$ decomposed preventing its partial evaporation or chemical reactions with adjacent protective layers. The surface image obtained by SEM and the surface micro-roughness verified by AFM also confirmed that samples prepared by the PRAM recorder have smoother surface than the samples prepared by using the conventional heater.

Development of B4C Thin Films for Neutron Detection (스퍼터링 코팅기법을 이용한 중성자 검출용 B4C 박막 개발)

  • Lim, Chang Hwy;Kim, Jongyul;Lee, Suhyun;Cho, Sang-Jin;Choi, Young-Hyun;Park, Jong-Won;Moon, Myung Kook
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.2
    • /
    • pp.79-86
    • /
    • 2015
  • $^3He$ gas has been used for neutron monitors as the neutron converter owing to its advantages such as high sensitivity, good ${\gamma}$-discrimination capability, and long-term stability. However, $^3He$ is becoming more difficult to obtain in last few years due to a global shortage of $^3He$ gas. Accordingly, the cost of a neutron monitor using $^3He$ gas as a neutron converter is becoming more expensive. Demand on a neutron monitor using an alternative neutron conversion material is widely increased. $^{10}B$ has many advantages among various $^3He$ alternative materials, as a neutron converter. In order to develop a neutron converter using $^{10}B$ (actually $B_4C$), we calculated the optimal thickness of a neutron converter with a Monte Carlo simulation using MCNP6. In addition, a neutron converter was fabricated by the Ar sputtering method and the neutron signal detection efficiencies were measured with respect to various thicknesses of fabricated a neutron converter. Also, we developed a 2-dimensional multi-wire proportional chamber (MWPC) for neutron beam profile monitoring using the fabricated a neutron converter, and performed experiments for neutron response of the neutron monitor at the 30 MW research reactor HANARO at the Korea Atomic Energy Research Institute. The 2-dimensional MWPC with boron ($B_4C$) neutron converter was proved to be useful for neutron beam monitoring, and can be applied to other types of neutron imaging.

Nanoscale Pattern Formation of Li2CO3 for Lithium-Ion Battery Anode Material by Pattern Transfer Printing (패턴전사 프린팅을 활용한 리튬이온 배터리 양극 기초소재 Li2CO3의 나노스케일 패턴화 방법)

  • Kang, Young Lim;Park, Tae Wan;Park, Eun-Soo;Lee, Junghoon;Wang, Jei-Pil;Park, Woon Ik
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.4
    • /
    • pp.83-89
    • /
    • 2020
  • For the past few decades, as part of efforts to protect the environment where fossil fuels, which have been a key energy resource for mankind, are becoming increasingly depleted and pollution due to industrial development, ecofriendly secondary batteries, hydrogen generating energy devices, energy storage systems, and many other new energy technologies are being developed. Among them, the lithium-ion battery (LIB) is considered to be a next-generation energy device suitable for application as a large-capacity battery and capable of industrial application due to its high energy density and long lifespan. However, considering the growing battery market such as eco-friendly electric vehicles and drones, it is expected that a large amount of battery waste will spill out from some point due to the end of life. In order to prepare for this situation, development of a process for recovering lithium and various valuable metals from waste batteries is required, and at the same time, a plan to recycle them is socially required. In this study, we introduce a nanoscale pattern transfer printing (NTP) process of Li2CO3, a representative anode material for lithium ion batteries, one of the strategic materials for recycling waste batteries. First, Li2CO3 powder was formed by pressing in a vacuum, and a 3-inch sputter target for very pure Li2CO3 thin film deposition was successfully produced through high-temperature sintering. The target was mounted on a sputtering device, and a well-ordered Li2CO3 line pattern with a width of 250 nm was successfully obtained on the Si substrate using the NTP process. In addition, based on the nTP method, the periodic Li2CO3 line patterns were formed on the surfaces of metal, glass, flexible polymer substrates, and even curved goggles. These results are expected to be applied to the thin films of various functional materials used in battery devices in the future, and is also expected to be particularly helpful in improving the performance of lithium-ion battery devices on various substrates.

Development and Evaluation of Traffic Conflict Criteria at an intersection (교차로 교통상충기준 개발 및 평가에 관한 연구)

  • 하태준;박형규;박제진;박찬모
    • Journal of Korean Society of Transportation
    • /
    • v.20 no.2
    • /
    • pp.105-115
    • /
    • 2002
  • For many rears, traffic accident statistics are the most direct measure of safety for a signalized intersection. However it takes more than 2 or 3 yearn to collect certain accident data for adequate sample sizes. And the accident data itself is unreliable because of the difference between accident data recorded and accident that is actually occurred. Therefore, it is rather difficult to evaluate safety for a intersection by using accident data. For these reasons, traffic conflict technique(TCT) was developed as a buick and accurate counter-measure of safety for a intersection. However, the collected conflict data is not always reliable because there is absence of clear criteria for conflict. This study developed objective and accurate conflict criteria, which is shown below based on traffic engineering theory. Frist, the rear-end conflict is regarded, when the following vehicle takes evasive maneuver against the first vehicle within a certain distance, according to car-following theory. Second, lane-change conflict is regarded when the following vehicle takes evasive maneuver against first vehicle which is changing its lane within the minimum stopping distance of the following vehicle. Third, cross and opposing-left turn conflicts are regarded when the vehicle which receives green sign takes evasive maneuver against the vehicle which lost its right-of-way crossing a intersection. As a result of correlation analysis between conflict and accident, it is verified that the suggested conflict criteria in this study ave applicable. And it is proven that estimating safety evaluation for a intersection with conflict data is possible, according to the regression analysis preformed between accident and conflict, EPDO accident and conflict. Adopting the conflict criteria suggested in this study would be both quick and accurate method for diagnosing safety and operational deficiencies and for evaluation improvements at intersections. Further research is required to refine the suggested conflict criteria to extend its application. In addition, it is necessary to develope other types of conflict criteria, not included in this study, in later study.

Adaptive Data Hiding Techniques for Secure Communication of Images (영상 보안통신을 위한 적응적인 데이터 은닉 기술)

  • 서영호;김수민;김동욱
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.5C
    • /
    • pp.664-672
    • /
    • 2004
  • Widespread popularity of wireless data communication devices, coupled with the availability of higher bandwidths, has led to an increased user demand for content-rich media such as images and videos. Since such content often tends to be private, sensitive, or paid for, there exists a requirement for securing such communication. However, solutions that rely only on traditional compute-intensive security mechanisms are unsuitable for resource-constrained wireless and embedded devices. In this paper, we propose a selective partial image encryption scheme for image data hiding , which enables highly efficient secure communication of image data to and from resource constrained wireless devices. The encryption scheme is invoked during the image compression process, with the encryption being performed between the quantizer and the entropy coder stages. Three data selection schemes are proposed: subband selection, data bit selection and random selection. We show that these schemes make secure communication of images feasible for constrained embed-ded devices. In addition we demonstrate how these schemes can be dynamically configured to trade-off the amount of ded devices. In addition we demonstrate how these schemes can be dynamically configured to trade-off the amount of data hiding achieved with the computation requirements imposed on the wireless devices. Experiments conducted on over 500 test images reveal that, by using our techniques, the fraction of data to be encrypted with our scheme varies between 0.0244% and 0.39% of the original image size. The peak signal to noise ratios (PSNR) of the encrypted image were observed to vary between about 9.5㏈ to 7.5㏈. In addition, visual test indicate that our schemes are capable of providing a high degree of data hiding with much lower computational costs.

Detection of IgY Specific to Salmonella enteritidris and S. typhimurium in the Yolk of Commercial Brand Eggs using ELISA (ELISA 방법으로 계란의 난황에 존재하는 Salmonella enteritidis와 S. typhimurium에 대한 IgY 측정)

  • 이승배
    • Food Science of Animal Resources
    • /
    • v.23 no.2
    • /
    • pp.161-167
    • /
    • 2003
  • Identification of salmonellosis-infected commercial poultry flocks has become a pivotal component of efforts to reduce incidence of egg-associated transmission of S. enteritidis and S. typhimurium to humans. As a basic study for sanitary control of S. enteritidis and S. typhimurium, main food-borne pathogenic bacteria in eggs produced by domestic hens, commercial egg samples were tested for specific antibodies to whole cells of S. enteritidis and S. typhimurium and outer membrane protein(OMP) of S. typhimurium by ELISA to detect infection of S. enteritidis and S. typhimurium in various groups of hens. When the antibody titers of yolks from three commercial brand eggs were tested after diluting in the ratio from 1:100 to 1:1,600 with double dilution method, ELISA values of the specific antibodies could be shown as differences in dilution patterns by comparing with negative control egg. When the antibody titers of the yolks from two commercial brand eggs were tested after diluting in the ratio of 1:200 and 1:1,000, ELISA values of specific antibodies were different among same brand eggs. When the antibody titers of yolks from five eggs sampled randomly from twenty one commercial brand eggs were tested after diluting in the ratio of 1:1,000, ELISA value of the specific antibodies were shown generally high. ELISA values of 28.5, 30, and 28.5% of yolks from 21 brand eggs were shown low and similar to negative control egg in antibody titers to whole cells of S. enteritidis and S. typhimurium and OMP of S. typhimurium, respectively. The results demonstrated that ELISA test of egg yolk antibody could provide a highly sensitive indicator to detect contamination of S. typhimurium and S. enteritidis in poultry, and could be used effectively to reduce incidence of S. typhimurium and S. enteritidis infection in poultry.

Diagnostic Value of Transbronchial Lung Biopsy -Including Diagnostic Yield According to Tumor-bronchus Relationship- (경기관지폐생검의 진단적 가치 -병변과 기관지의 관계에 따른 진단율을 포함한 연구-)

  • Kang, Tae-Kyong;Cha, Seung-Ick;Park, Jae-Yong;Chae, Sang-Chul;Kim, Chang-Ho;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.4
    • /
    • pp.438-447
    • /
    • 2000
  • Background : Transbronchial lung biopsy (TBLB) is a relatively simple and convenient procedure to obtain lung tissue from a patient with diffuse or localized lesion on chest radiographs, whose disease cannot be diagnosed through routine tests. The authors tried to evaluate the diagnostic value of TBLB, especially, the concordance between CT scan and TBLB with respect to the location of the lesion and diagnostic yield according to tumor-bronchus relationship. Method : We reviewed the medical records, plain chest films, and chest CT scans of 278 patients who underwent TBLB at Kyungpook National University Hospital between January 1996 and June 1998. Results : One hundred and sixteen (41.7 %) patients were diagnosed by TBLB. Diagnostic yield of TBLB of malignant tumors tended to be higher than that of benign diseases (64.7% versus 53.9%, p=0.09). Of primary lung cancers, TBLB was more diagnostic in adenocarcinoma and small-cell carcinoma than other cell types (p<0.01) and, of benign diseases, more diagnostic in tuberculosis than in non-tuberculous diseases (p<0.05). There was no significant difference in the diagnostic rate according to the location of the tumor. The diagnostic rate tended to increase with the size of tumor (p=0.06). The diagnootic rate of TBLB did not differ according to the pattern of lesion in benign diseases. However, in malignant diseases TBLB was more diagnostic in diffuse/multiple nodular lesions than in localized lesions(p<0.05). According to the tumor-bronchus relationship, TBLB was more diagnootic in type I/II groups than in other types. CT scan and TBLB showed a strong correlation with respect to the localization of the lesion (r=0.994, p<0.01). Conclusion : The above results show that TBLB is useful in the diagnosis of lung disease. CT scan and TBLB showed a strong correlation in determining the location of the lesion. Diagnostic yield of TBLB is higher in lesions with 'bronchus sign' (type I and II). TBLB and other diagnootic methods such as transthoracic needle aspiration are expected to complement one another in the diagnosis of lung diseases.

  • PDF

The Study on New Radiating Structure with Multi-Layered Two-Dimensional Metallic Disk Array for Shaping flat-Topped Element Pattern (구형 빔 패턴 형성을 위한 다층 이차원 원형 도체 배열을 갖는 새로운 방사 구조에 대한 연구)

  • 엄순영;스코벨레프;전순익;최재익;박한규
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.7
    • /
    • pp.667-678
    • /
    • 2002
  • In this paper, a new radiating structure with a multi-layered two-dimensional metallic disk array was proposed for shaping the flat-topped element pattern. It is an infinite periodic planar array structure with metallic disks finitely stacked above the radiating circular waveguide apertures. The theoretical analysis was in detail performed using rigid full-wave analysis, and was based on modal representations for the fields in the partial regions of the array structure and for the currents on the metallic disks. The final system of linear algebraic equations was derived using the orthogonal property of vector wave functions, mode-matching method, boundary conditions and Galerkin's method, and also their unknown modal coefficients needed for calculation of the array characteristics were determined by Gauss elimination method. The application of the algorithm was demonstrated in an array design for shaping the flat-topped element patterns of $\pm$20$^{\circ}$ beam width in Ka-band. The optimal design parameters normalized by a wavelength for general applications are presented, which are obtained through optimization process on the basis of simulation and design experience. A Ka-band experimental breadboard with symmetric nineteen elements was fabricated to compare simulation results with experimental results. The metallic disks array structure stacked above the radiating circular waveguide apertures was realized using ion-beam deposition method on thin polymer films. It was shown that the calculated and measured element patterns of the breadboard were in very close agreement within the beam scanning range. The result analysis for side lobe and grating lobe was done, and also a blindness phenomenon was discussed, which may cause by multi-layered metallic disk structure at the broadside. Input VSWR of the breadboard was less than 1.14, and its gains measured at 29.0 GHz. 29.5 GHz and 30 GHz were 10.2 dB, 10.0 dB and 10.7 dB, respectively. The experimental and simulation results showed that the proposed multi-layered metallic disk array structure could shape the efficient flat-topped element pattern.

Effect of Ta/Cu Film Stack Structures on the Interfacial Adhesion Energy for Advanced Interconnects (미세 배선 적용을 위한 Ta/Cu 적층 구조에 따른 계면접착에너지 평가 및 분석)

  • Son, Kirak;Kim, Sungtae;Kim, Cheol;Kim, Gahui;Joo, Young-Chang;Park, Young-Bae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.1
    • /
    • pp.39-46
    • /
    • 2021
  • The quantitative measurement of interfacial adhesion energy (Gc) of multilayer thin films for Cu interconnects was investigated using a double cantilever beam (DCB) and 4-point bending (4-PB) test. In the case of a sample with Ta diffusion barrier applied, all Gc values measured by the DCB and 4-PB tests were higher than 5 J/㎡, which is the minimum criterion for Cu/low-k integration without delamination. However, in the case of the Ta/Cu sample, measured Gc value of the DCB test was lower than 5 J/㎡. All Gc values measured by the 4-PB test were higher than those of the DCB test. Measured Gc values increase with increasing phase angle, that is, 4-PB test higher than DCB test due to increasing plastic energy dissipation and roughness-related shielding effects, which matches well interfacial fracture mechanics theory. As a result of the 4-PB test, Ta/Cu and Cu/Ta interfaces measured Gc values were higher than 5 J/㎡, suggesting that Ta is considered to be applicable as a diffusion barrier and a capping layer for Cu interconnects. The 4-PB test method is recommended for quantitative adhesion energy measurement of the Cu interconnect interface because the thermal stress due to the difference in coefficient of thermal expansion and the delamination due to chemical mechanical polishing have a large effect of the mixing mode including shear stress.