• 제목/요약/키워드: Thickness measurement

검색결과 1,834건 처리시간 0.032초

외복사근과 다열근에 대한 초음파 영상과 표면 근전도 측정방법의 신뢰도와 타당도 (Reliability and Validity of Ultrasound Imaging and sEMG Measurement to External Abdominal Oblique and Lumbar Multifidus Muscles)

  • 김창용;최종덕;김선엽;오덕원;김진경
    • 한국전문물리치료학회지
    • /
    • 제18권1호
    • /
    • pp.37-46
    • /
    • 2011
  • The purpose of this study was to investigate intra-rater reliability and determine the validity of electromyography (EMG) measurements to represent muscle activity and ultrasonography (US) to represent muscle thickness during manual muscle testing (MMT) to external abdominal oblique (EO) and lumbar multifidus (MF). Twenty healthy subjects were recruited for this study and asked to perform MMT at differing levels. The subjects' muscle activity using EMG was measured by a ratio to maximum voluntary contraction (MVC) and root mean square (RMS) methods. The subjects' muscle thickness using US was measured by raw muscle thickness and change ratio of thickness to maximum (MVC) or resting condition. In three trials, measurements were performed on each subject by one examiner. The intra-rater reliability of measurements of EMG and US to EO and MF was calculated using intra-class coefficients. The intra-rater reliability of all measurements was excellent (ICC=.75~.98) in EMG and US. The conduct validity was calculated by one-way ANOVA with repeated measurements to compare whether the EMG and US measurements were different between MMT at different levels. There was only a significant difference between all grades at %MVC thickness measurement of US. These results suggest that a %MVC thickness measurement of US was a more sensitive and discriminate in all manual muscle testing grades. This information will be useful for the selection of US measurement and analysis methods in clinics.

광학적 기법에 의한 Frost 두께 측정방법의 개발 (Development of Frost Thickness Measurement Method Using Optical Technique)

  • 정재홍;윤상열;김경천
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.654-659
    • /
    • 2001
  • A new non-contact method of the frost thickness measurement has been developed. The method is based on the digital image processing technique to identify the reflection edge of the image captured by a CCD camera under laser sheet light illumination. To insure the accuracy of frost layer thickness, an in-situ calibration procedure is carried out with a calibration target with 0.5mm holes. Using the mapping function obtained by the calibration procedure, the contour of frost surface can be estimated with sub-pixel resolutions. The developed method is applied to study the effect of cooling plate temperature on the frost thickness in a small low speed wind tunnel.

  • PDF

모델에 의한 흡배관내 연료유동의 거동에 관한 실험염구 (An experimental study on the behavior of fuel flow in intake manifold by the model)

  • 박경석
    • 오토저널
    • /
    • 제5권3호
    • /
    • pp.33-44
    • /
    • 1983
  • This paper deals with the experimental study on the behavior of fuel (methanol) in intake manifold by using the basic apparatus which is manufactured the visible straight tube type model. In this study, the new device for liquid film thickness measurement and vaporization rate measurement are introduced to investigate the variation of liquid film thickness along the intake manifold and to observe the effect of vaporization of injected fuel. the results are summarized as follows: 1) The vaporization rate increases in proportion to decreasing of throttle valve angle and growing air fuel ratio. 2) The liquid film thickness along the intake manifold is mostly independent for the throttle valve angle in low air velocity and then affected in high air velocity, but the distribution of the liquid film thickness on circumferential position almost constant in the region of 300mm down stream from carburetor. 3) The mean liquid film thickness is 0.04 - 0.18mm in case of methanol in the region of air velocity Va = 12m/s - 55m/s and decreases with decreasing the throttle valve angle.

  • PDF

액막두께 측정방법을 이용한 스월 인젝터의 분무특성 연구 (Spray characteristics of swirl injector using liquid film thickness measurement)

  • 김성혁;김동준;김병선;윤영빈
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2005년도 제25회 추계학술대회논문집
    • /
    • pp.251-255
    • /
    • 2005
  • 본 연구에서는 스월 인젝터의 기하학적 형상에 따른 분무특성 파악을 위해 액막두께 측정방법을 사용하였다. 액막두께 측정을 위해 특별히 제작된 인젝터를 사용하였으며, 백홀과 스월챔버 그리고 오리피스의 길이에 따른 분무특성을 확인하였다. 분무특성 파악을 위해 분사압에 따른 유량변화, 오리피스 하단의 액막두께와 분무각을 측정하였다.

  • PDF

Dichromatic 투사광선에 따른 나노 미터 해상도의 점접촉 유막 두께 측정 연구 (Study on the Measurement Technology of Fluid Film Thickness with Nanometer Scale by Dichromatic Incident Light)

  • 공현상;장시열
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.686-689
    • /
    • 2003
  • Many technologies are applied to the measurement of elastohydrodynamic lubrication (EHL) film thickness. In particular, optical in-situ interferometric method has many advantages in making the actual contact behaviors realized with the experimental apparatus. Careful selection of incident lights greatly enhances the fringe resolution up to nanometer scale by using image processing technology. In this work, it is found that dichromatic incident light can provide much finer resolution of EHL film thickness than monochromatic incident light, because it has much more variables of color components to be discriminated among the wavelengths of colors according the variations of EHL film thickness. Some simulated interferometric images are shown how the film thickness is resolutionized in nanometer scale

  • PDF

나노인덴테이션을 이용한 나노 임프린트된 폴리머 박막의 잔류두께 측정기법 (A measurement technique for residual thickness of nano-imprinted polymer film using nano-indentation.)

  • 이학주;고순규;김재현;허신;이응숙;정준호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1921-1926
    • /
    • 2003
  • Nano-imprint technology has been vigorously studied by many researchers for it is one of the most promising technologies for manufacturing the pattern with its critical dimension below 100nm. In the nano-imprint technology, nano patterns are transferred on a polymer film and the transferred patterns are used as an etch mask to define the designed patterns on a substrate or a metal layer. To this end, it is important to keep the residual thickness of the imprinted polymer film uniform. In this study, a novel measurement technique to measure the residual thickness of films is proposed based on nanoindentation theory. This technique has advantages of saving time and measuring the residual thickness of highly-localized portions in comparison with other techniques, but has limitation of requiring calibration process.

  • PDF

Description of mandibular bone quality based on measurements of cortical thickness using Mental Index of male and female patients between 40-60 years old

  • Hardanti, Sylviana;Azhari, Azhari;Oscandar, Fahmi
    • Imaging Science in Dentistry
    • /
    • 제41권4호
    • /
    • pp.151-153
    • /
    • 2011
  • Purpose : The purpose of this study was to obtain the description of the mandibular bone quality of male and female patients between 40-60 years old and their differences based on mandibular cortical bone thickness measured using Mental Index (MI). Materials and Methods : Forty digital panoramic radiographs, which consisted of twenty male and twenty female patients, 40-60 years old, were observed. Mandibular cortical bone thickness was measured using MI on both sides of the mandible. The average MI score of two groups were then assessed using t-sample independent test. Results : There were significant differences of mandibular bone quality based on mandibular cortical bone thickness measurement using MI between male and female patients (p<0.05). Conclusion : Mandibular bone quality based on cortical bone thickness measurement using MI of male and female patients indicated a significant difference.

원전 배관의 두께 측정 데이터에 대한 신뢰도 분석 방법 및 적용 (Method and Application for Reliability Analysis of Measurement Data in Nuclear Power Plant)

  • 윤훈;황경모;이효승;문승재
    • Corrosion Science and Technology
    • /
    • 제14권1호
    • /
    • pp.33-39
    • /
    • 2015
  • Pipe wall-thinning by flow-accelerated corrosion and various types of erosion is significant damage in secondary system piping of nuclear power plants(NPPs). All NPPs in Korea have management programs to ensure pipe integrity from degradation mechanisms. Ultrasonic test(UT) is widely used for pipe wall thickness measurement. Numerous UT measurements have been performed during scheduled outages. Wall-thinning rates are determined conservatively according to several evaluation methods developed by Electric Power Research Institute(EPRI). The issue of reliability caused by measurement error should be considered in the process of evaluation. The reliability analysis method was developed for single and multiple measurement data in the previous researches. This paper describes the application results of reliability analysis method to real measurement data during scheduled outage and proved its benefits.

만성 뇌졸중 환자의 앞 톱니근과 하부 등세모근의 비대칭성 연구 (The Study of Asymmetrical of the Serratus Anterior and Lower Trapezius Muscles in Chronic Stroke Patients)

  • 정주리;이완희
    • 대한물리의학회지
    • /
    • 제10권4호
    • /
    • pp.81-90
    • /
    • 2015
  • PURPOSE: The purpose of this study was to compare the muscle architecture of serratus anterior and lower trapezius using rehabilitative ultrasound imaging (RUSI) in affected and unaffected side of chronic stroke patients. METHODS: The participants were thirty five patients with stroke hemiplegia in this study. RUSI was used to measure the muscle thickness of the serratus anterior and lower trapezius muscles. We compared the muscle thickness according to affected side and sex, determined the reliability of the measurement image. Independent t-test, intra-class correlation coefficient (ICC) and standard error of measurement (SEM) were used for statistical analysis. RESULTS: Significant difference in muscle thickness of serratus anterior was observed between affected and unaffected side (p<.001). Muscle thickness according to gender showed a significant difference in unaffected side of serratus anterior (p<.05). Compare asymmetry ratio of serratus anterior and lower trapezius muscle thickness showed a significant difference (p<.001). ICC for intra-reliability was .944~.962 in serratus anterior and .873~.925 in lower trapezius muscle thickness, respectively. SEM was .001~.004 in serratus anterior and .002~.008 in lower trapezius muscle. CONCLUSION: This study, using RUSI, showed significant difference in muscle thickness of serratus anterior in affected and unaffected side of stroke patients. RUSI is a practical tool for measuring soft-tissue thickness in the scapular region muscle of stroke.

4MV X-선을 이용한 조직보상체 두께비 연구 및 응용 (A study on tissue compensator thickness ratio and an application for 4MV X-rays)

  • 김영범;정희영;권영호;김유현
    • 대한방사선치료학회지
    • /
    • 제8권1호
    • /
    • pp.55-61
    • /
    • 1996
  • A radiation beam incident on irregular or sloping surface produces an inhomogeneity of absorbed dose. The use of a tissue compensator can partially correct this dose inhomogeneity. The tissue compensator should be made based on experimentally measured thickness ratio. The thickness ratio depends on beam energy, distance from the tissue compensator to the surface of patient, field size, treatment depth, tissue deficit and other factors. In this study, the thickness ratio was measured for various field size of $5cm{\times}5cm,\;10cm{\times}10cm,\;15cm{\times}15cm,\;20cm{\times}20cm$ for 4MV X-ray beams. The distance to the compensator from the X-ray target was fixed, 49cm, and measurement depth was 3, 5, 7, 9 cm. For each measurement depth, the tissue deficit was changed from 0 to(measurement depth-1)cm by 1cm increment. As a result, thickness ratio was decreased according to field size and tissue deficit was increased. Use of a representative thickness ratio for tissue compensator, there was $10\%$ difference of absorbed dose but use of a experimentally measured thickness ratio for tissue compensator, there was $2\%$ difference of absorbed dose. Therefore, it can be concluded that the tissue compensator made by experimentally measured thickness ratio can produce good distribution with acceptable inhomogeneity and such tissue compensator can be effectively applied to clinical radiotherapy.

  • PDF