• Title/Summary/Keyword: Theta wave

Search Result 140, Processing Time 0.025 seconds

EEG 16 channel variations between the non-stimulation and the moxibustion stimulated subjects for CV4, CV8, and CV12 acupuncture points (중완, 신궐 및 관원 경혈의 뜸 자극과 무 자극 대상군의 16채널 뇌파 변화에 관한 연구)

  • Yoon, Dong-Eop;Song, Hong-Bok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.12
    • /
    • pp.2755-2760
    • /
    • 2010
  • The moxibustion therapy of orient medical is well known. Moxibustion method is used to burning moxibustion. The variation factors of the moxibustion stimulation for body can be applied to the electronic moxibustion method. This study is to analyze and examine the electroencephalogram(EEG) variations for moxibustion stimulation. In experiment, we divided six healthy male subjects into two same sized groups : with and without stimuli. The given stimuli are the moxibustion for CV4(Kwan-Won), CV8(Shin-Guel), and CV12(Jung-wan) acupuncture points. We have analyzed the power spectrum for ${\alpha}$, ${\beta}$, ${\delta}$, ${\Theta}$ waves and the average EEG variation level and each channels variation level of EEG. The result was that the moxibustion stimulation decreased the EEG levels of parietal lobe(ch 2, 3, 6, 7) according to the somatosensory system. And the apparent different points are that mild-heat($42{\sim}44^{\circ}C$) stimulation generating ${\alpha}$-wave is increased and ${\beta}$-wave is decreased, also slight-hot($45{\sim}48^{\circ}C$) stimulation made ${\alpha}$-wave decrease and ${\beta}$-wave increase for occipital lobe(ch 4,8) on the simulation group.

Frontal Asymmetry Analysis of Theta Wave in the Audio Emotional Experiment Revealed by Event-related Spectral Perturbation

  • Du, Ruoyu;Lee, Hyo Jong
    • Annual Conference of KIPS
    • /
    • 2014.04a
    • /
    • pp.992-994
    • /
    • 2014
  • Hemispheric asymmetry in prefrontal activation have been proposed in two decades ago, as measured by electroencephalographic (EEG) power in the theta band (4-8Hz), is related to reactivity to affectively pleasure audio stimuli. In this study, we designed an emotional audio stimulus experiment in order to verify frontal EEG asymmetry by analyzing ERSP results. Thirty healthy college students volunteered the stimulus experiment with the standard IADS affective sounds. These affective sound clips are classified in three emotion states, happy, neutral and fear. ERSP image results revealed that there are the stronger responses of high arousal (fear and happy) in the left prefrontal lobe, while the stronger responses of low arousal (neutral) in the right pre-frontal lobe. However, the high pleasure emotions (happy) can elicit greater relative right EEG activity, while the low and middle pleasure emotions (fear and neutral) can elicit the greater relative left EEG activity. Additionally, the most response differences of theta band have been found out in the medial frontal lobe, which is proved as the frontal midline theta.

Evaluation of Cranial Sacral Therapy (CST) Based Pillow on Sleep Induction Using the Electroencephalogram (EEG) (뇌파를 이용한 두개천골요법 기반 베개의 수면유도 효과 검증)

  • Kwon, Hyeok Chan;Phyo, Jung Bin;Park, Yong Gil;Lee, Hyun Ju;Tae, Ki Sik
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.1
    • /
    • pp.55-61
    • /
    • 2018
  • The purpose of this study was to investigate the effect of a pillow simulated with cranial sacral therapy (CST) on sleep induction using electroencephalography (EEG). This study included 12 voluntary participants divided into experimental group (CST group) and control group (Non-CST group) to observe EEG changes. The position of the electrode for EEG measurement consists of 8 channels electrodes (Fp1, Fp2, F3, F4, T3, T4, P3 and P4). In this study, we measured the fall asleep time, change of brain activity and sleep wave ratio using EEG wave (${\delta}$, ${\theta}$, ${\alpha}$, ${\beta}$ and ${\gamma}$). As a result, the mean fall asleep time of the experimental group was shorter than that of the control group significantly (p < 0.001). Also in comparison with the control group, both the delta (d) and theta (q) wave corresponding to the slow waves showed a larger increase and the alpha (a) wave showed a larger decrease significantly. The slow waves of experimental group showed a higher rate of significant increase than the control group (p < 0.001). Therefore this study showed that pillow based on CST had an effective in improving sleep induction and quality.

The Effect of Acupuncture at PC7(Daereung) on EEG in Normal Human Subject (대릉(大陵)(PC7) 침자가 뇌파에 미치는 영향)

  • Park, Cheol-Jin;Lee, Sang-Ryong
    • Korean Journal of Acupuncture
    • /
    • v.27 no.2
    • /
    • pp.141-157
    • /
    • 2010
  • Objectives : The aim of this study is to examine the effects of acupuncture at PC7(Daereung) on normal human EEG using power spectral analysis. Methods : EEG power spectrum exhibits site-specific and state-related differences in specific frequency bands. In this study, power spectrum was used as a measure of complexity. 30 subjects (16 males and 14 females; averaged age = 23.4 years) were engaged with thirty channel EEG study. Results : In $\alpha$(alpha) band, the power values at Fp1, Fp2, F7, F8 channels(p<0.05) during PC7 treatment were significantly decreased. But, the power values at Fz channel(p<0.05) during non-acupoint treatment was significantly decreased. In $\beta$(beta) band, the power values at Fp1, Fp2 channels(p<0.05) during PC7 treatment were significantly decreased. But, the power values at Fz channel(p<0.05) during non-acupoint treatment was significantly decreased and at F8, TCP2 channels(p<0.05) during non-acupoint treatment were increased. In $\theta$(theta) band, the power values at Fp1, Fp2, F7, F8 channels(p<0.05) during PC7 treatment were significantly decreased. But, the power values at Fz channel(p<0.05) during non-acupoint treatment was significantly decreased. In $\delta$(delta) band, the power values at Fp1, Fp2, F7, Fz, F8 channels (p<0.05) during PC7 treatment were significantly decreased. But, the power values at Fz channel (p<0.05) during non-acupoint treatment was significantly decreased. $\alpha/\beta$ values during PC7 treatment were decreased. $\beta/\theta$ values during PC7 treatment were decreased. Conclusion : These results suggest that acupuncture at PC7 induce the change on $\alpha$(alpha), $\beta$(beta), $\theta$ (theta), $\delta$(delta) wave values being decreased and and bothe $\alpha/\beta$ and $\beta/\theta$ values being decreased respectively. This is considered that acupuncture at PC7 affects the activity of cerebral cortex and endocrine system.

An Implicit Method to Analysis Unsteady Flow (부정류의 IMPLICIT 수치해석)

  • 이종태
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.17 no.2
    • /
    • pp.71-76
    • /
    • 1981
  • In order to make a numerical modeling for the one dimensional unsteady flow which expressed by Saint Venant partial differential equations, Preissmann's implicit scheme was used, and it's stability and accuracy was mentioned. By introducing recurrence relations make it possible to use double sweep algorithm. Effective parameters to the result were the values of the $\Delta$t/$\Delta$x, $\theta$ and the chezy coefficient. In oder to get numerical solutions with enough accuracy, $\Delta$t/$\Delta$x should not be far from the value of 1, and the criteria of the $\theta$ was 0.6<$\theta$<1.0 for the stability without condition. This model should be calibrated by real field data, and expected to be developed for the simulation of the river system and to the long wave analysis for one dimensional coastal zone problem.

  • PDF

Response State of EEG Wave Type on Visual Cortex According to Color Vision Target (색각 시표에 따른 시피질 뇌파의 반응 상태)

  • Kim, Douk Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.5-9
    • /
    • 2000
  • The visual evoked potential was electrophysiological method for the identify of the EEG response on visual cortex. This test was objective test method on the eye function. This study was used the visual evoked potential for the objective color test. The subjects was a normal color function in Korean adults. The test condition was performed on the differens distance and illumination. According to convergence condition of color vision target. On the appearance of EEG wave of visual stimulation on visual cortex. The most EEG wave style was delta wave, and the next amount wave form was beta wave and theta wave, and the least EEG wave form was alpha wave. The histogram of amplitude of EEG wave form was almost non-Gaussian shape, and the phase diagram of amplitude was almost all linear shape. On the kinds of color vision target, the frequency of EEG wave style appeared a similar results.

  • PDF

A Study on EEG based Concentration transmission and Brain Computer Interface Application (뇌파기반 집중도 전송 및 BCI 적용에 관한 연구)

  • Lee, Chung-Heon;Kwon, Jang-Woo;Kim, Gyu-Dong;Lee, Jun-Oh;Hong, Jun-Eui;Lee, Dong-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.155-156
    • /
    • 2008
  • This research measures EEG signals which are generating on head skin and extracts brain concentration level related with brain activity. We develop concentration wireless transmission system for controlling hardware by using this signal. Two channels are used for measuring EEG signal on front head and Biopac system with MP-100 and EEG100C was used for measuring EEG signal, amplifying and filtering the signal. LabView 8.5 was also used for FFT transformation, frequency and spectrum analysis of the measure EEG signal. As a result, ${\alpha}$ wave, ${\beta}$ wave, ${\theta}$ wave and ${\delta}$ wave were classified. we extracted the concentration index by adapting concentration extraction algorithm. This concentration index was transferred into lego automobile device by wireless module and applied for BCI application.

  • PDF

Measurement of Electrophysiological Changes Caused by Electromagnetic Radiation Absorbed in Biobody (전자파에 노출된 생체의 전기 생리적 변화의 측정)

  • Ju-Tae Park
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.7 no.4
    • /
    • pp.353-362
    • /
    • 1996
  • In this paper, SAR distribution is calculated according to the rabbit's head using approximation of its medium three layers model. Our experiment was classified 5 groups dependent on the power intensity of 2,450MHz microwave to measure EEG(Electroencephalograph) of rabbit, which was checked in left frontal lobe before and after irradiation of microwave. In results, mean total power of EEG was slightly decreased and mean composition percentages of $\theta$, $\delta$ and $\beta$ wave were increased after irradiation in observation. It means to decrease of elect- rophysiologic activity and trend of fast wave in brain after irradiation of its microwave. We analyzed the electrophysiological effect of the biobody quantitatively using measured EEG and estimated MPE (Maximum Permissible Exposure).

  • PDF

Effectiveness Measurement of TV Advertisement for Fashion Goods with EEG and Affective Responses as Determined by the Types of Appeal (뇌파와 감정반응 평가를 통한 패션제품의 TV 광고효과 연구)

  • Choi Ju-Young;Kim Mi-Sook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.9_10 s.146
    • /
    • pp.1230-1240
    • /
    • 2005
  • The purpose of this study was to apply a scientific and systematic method for assessing fashion goods' TV ads effects by EEG and questionnaires as determined by the type of ads appeal. Ads stimulants used in the survey were limited to underwear and sportswear that were advertised during $2000{\sim}2002$ on TV: 4 information-transferring and 4 emotion-evoking ads were used. Subjects were thirty healthy male and female college students. EEG was extracted from six lobes and the recorded EEG was analyzed by the range of frequency of ${\theta},\;{\alpha}\;and\;{\beta}$ waves. Data were analyzed by SPSS 11.0 with reliability test, $x^2$-analysis, t-test and frequency analysis. The emotion-evoking ads showed higher scores in memory, recall and attitude towards the ads. The responses of ${\theta}\;and\;{\alpha}$ wave were active throughout the ads but the response of ${\beta}$ wave was not. The results by the survey and the EEG test showed high similarities, indicating the EEG tests could be used as the supplementary tool for measuring ads effects.

Numerical Analysis of a Weak Shock Wave Propagating in a Medium Using Lattice Boltzmann Method (LBM)

  • Kang, Ho-Keun;Michihisa Tsutahara;Ro, Ki-Deok;Lee, Young-Ho
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.12
    • /
    • pp.2034-2041
    • /
    • 2003
  • This study introduced a lattice Boltzmann computational scheme capable of modeling thermo hydrodynamic flows with simpler equilibrium particle distribution function compared with other models. The equilibrium particle distribution function is the local Maxwelian equilibrium function in this model, with all the constants uniquely determined. The characteristics of the proposed model is verified by calculation of the sound speeds, and the shock tube problem. In the lattice Boltzmann method, a thermal fluid or compressible fluid model simulates the reflection of a weak shock wave colliding with a sharp wedge having various angles $\theta$$\sub$w/. Theoretical results using LBM are satisfactory compared with the experimental result or the TVD.