• Title/Summary/Keyword: Thermometer

Search Result 355, Processing Time 0.037 seconds

Realization of Triple Point of Ne, $O_2$, Ar, Hg and $H_2O$ for International Comparison of Capsule-type Platinum Resistance Thermometer (캡슐형 백금저항온도계 국제비교를 위한 네온, 산소, 아르곤, 수은 및 물의 삼중점 실현)

  • Kang, Kee-Hoon;Kim, Yong-Gyoo;Gam, Kee-Sool
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.153-162
    • /
    • 2000
  • Triple points of high purity materials have been used to calibrate primarily the capsule-type platinum resistance thermometer (PRT) in the temperature range of the triple point of equilibrium hydrogen (13.8033 K) and water (273.16 K). In this work, triple points of Ne, $O_2$, Ar, Hg and $H_2O$ except for the triple point of equilibrium hydrogen were realized to establish the International Temperature Scale of 1990 (ITS-90). At each fixed point, two capsule-type PRTs, which were selected for the international comparison, were tested two times. The combined uncertainties of the realization of each triple point were calculated considering the type A and type B evaluation. In Korea Research Institute of Standards and Science, the combined standard uncertainties of the defining triple Points by the ITS-90 were estimated to about 0.18 mK for Ne, 0.14 mK for $O_2$, 0.14 mK for Ar, 0.24 mK for Hg and 0.11 mK for $H_2O$, respectively.

  • PDF

The Fabrication and Characteristics of RTD(Resistance Thermometer Device) for Micro Thermal Sensors (마이크로 열 센서용 측온저항체 온도센서의 제작 및 특성)

  • Chung, Gwiy-Sang;Hong, Seog-Woo
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.171-176
    • /
    • 2000
  • The physical and electrical characteristics of MgO and Pt thin-films on it, deposited by reactive sputtering and rf magnetron sputtering, respectively, were analyzed with annealing temperature and time by four-point probe, SEM and XRD. Under annealing conditions of $1000^{\circ}C$ and 2 hr, MgO thin-film had the properties of improving Pt adhesion to $SiO_2$ and insulation without chemical reaction to Pt thin-film, and the sheet resistivity and the resistivity of Pt thin-film deposited on it were $0.1288\;{\Omega}/{\square}$ and $12.88\;{\mu}{\Omega}{\cdot}cm$, respectively. We made Pt resistance pattern on $SiO_2$/Si substrate by lift-off method and fabricated thin-film type Pt-RTD(resistance thermometer device) for micro thermal sensors by Pt-wire, Pt-paste and SOG(spin-on-glass). In the temperature range of $25{\sim}400^{\circ}C$, the TCR value of fabricated Pt-RTD with thickness of $1.0{\mu}m$ was $3927\;ppm/^{\circ}C$ close to the Pt bulk value. Resistance values were varied linearly within the range of measurement temperature.

  • PDF

Inter-comparison of temperature measurement capability using standard platinum resistance thermometers (표준백금저항온도계를 이용한 온도측정능력 상호비교)

  • Gam, K.S.;Kang, C.S.;Lee, Y.J.;Lee, K.B.;Kim, Y.G.;Park, S.N.
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.86-94
    • /
    • 2009
  • Temperature measurement capability was inter-compared using the transfer standard platinum resistance thermometers(SPRT) among four laboratories of KRISS. The transfer SPRTs were primarily calibrated at the triple point of water and Ga melting point, then used at inter-comparison experiment. Temperature difference of calibration value between temperature laboratory and length laboratory at $20^{\circ}C$ was -0.7 mK and +2.4 mK at density laboratory. Temperature measured near $20^{\circ}C$, $25^{\circ}C$ and $30^{\circ}C$ at fluid flow laboratory was deviated by $34.2{\sim}80.4\;mK$ from the calibration values of the transfer SPRT. Ga melting points was inter-compared among three laboratories, and the difference of Ga melting points against the standard Ga melting point of temperature laboratory were $0.03{\sim}0.54\;mK$ at length laboratory and 0.02 mK at density laboratory.

Monitoring Pig Body Temperature Using Infrared Sensors

  • Jang, Jin Cheol;Lee, Min Ho;Lee, Jun Yeop;Choi, Hee Chul;Choi, Dong Yun;Kim, Hyeok Ju;Kim, Hyeon Tae
    • Journal of Biosystems Engineering
    • /
    • v.40 no.4
    • /
    • pp.368-372
    • /
    • 2015
  • Purpose: The purpose of this study is to verify the feasibility of using an infrared sensor to measure the body temperature of a sow. We first conducted experiments on three pigs by using three infrared sensors and one indoor temperature sensor. Methods: The three infrared sensors were installed inside our model house and were used to take temperature measurements per second of the backs of the pigs. While feeding, the temperatures of the backs of the pigs were measured at distances of 10 cm, 20 cm, and 30 cm from the infrared sensors. Results: We concluded that the relation between the temperature of the pigs' backs and the indoor temperature was y =0.549x + 18.459 at a measuring distance of 30 cm. The relation was y = 0.645x + 15.461 for a distance of 20 cm and y = 0.760x + 11.913 for a distance of 10 cm. We found high correlation between the indoor temperature and the temperature of the pigs' backs. Conclusions: It is possible to use an infrared thermometer to monitor the temperature of pigs' backs. This system seems to be feasible and effective in monitoring pig temperature. The use of an infrared thermometer will also make daily monitoring easy. In later experiments, the possibility of developing a system that can determine if an error can be corrected by using infrared sensor is explored by considering humidity variables.

Analysis of infrared thermal image for melting processes of Co-Cr-Mo based alloy using high frequency induction casting machine (치과용 고주파 주조기를 이용한 Co-Cr-Mo계 합금 용해과정의 적외선 열화상 분석)

  • Kang, Hoo-Won;Park, Young-Sik;Hwang, In;Lee, Chang-Ho;Heo, Yong;Won, Yong-Gwan
    • Journal of Technologic Dentistry
    • /
    • v.36 no.3
    • /
    • pp.149-158
    • /
    • 2014
  • Purpose: Dental casting Co-Cr-Mo based alloys of five kinds of ingot type and two kinds of shot type were analyzed the melting processes with heating time of high frequency induction centrifugal casting machine using infrared thermal image analyzer. Methods: When Co-Cr-Mo based alloys were put about 30g/charge in the ceramic crucible of high frequency induction centrifugal casting machine and heat, Infrared thermal image analyzer and IR thermometer indicated these alloys in the crucible were set and operated. Results: The melting temperatures of alloys measuring infrared thermal image analyzer were deviated ${\pm}10^{\circ}C$ compared to those of manufacturing company. On the other hand, the melting time of alloys were differently appeared with the shape of alloys(ingot and shot type). Conclusion: The melting temperatures of dental Co-Cr-Mo based alloys were measured the degree of $1,360{\sim}1410^{\circ}C$ and the heating time with the alloys of ingot and shot type were deviated ${\pm}10sec$.

Design of a 2.5V 10-bit 300MSPS CMOS D/A Converter (2.5V 10-bit 300MSPS 고성능 CMOS D/A 변환기의 설계)

  • Kwon, Dae-Hoon;Song, Min-Kyu
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.7
    • /
    • pp.57-65
    • /
    • 2002
  • In this paper, a 2.5V 10-bit 300MSPS CMOS D/A Converter is described. The architecture of the D/A Converter is based on a current steering 8+2 segmented type, which reduces non-linearity error and other secondary effects. In order to achieve a high performance D/A Converter, a novel current cell with a low spurious deglitchnig circuit and a novel inverse thermomeer decoder are proposed. To verify the performance, it is integrated with $0.25{\mu}m$ CMOS 1-poly 5-metal technology. The effective chip area is $1.56mm^2$ and power consumption is about 84mW at 2.5V power supply. The simulation and experimental results show that the glitch energy is 0.9pVsec at fs=100MHz, 15pVsec at fs=300MHz in worst case, respectively. Further, both of INL and DNL are within ${\pm}$1.5LSB, and the SFDR is about 45dB when sampling, frequency, is 300MHz and output frequency is 1MHz.

The Effects of Korean Ginseng and American Ginseng on Body Temperature in Koreans and Chineses -Double-blind Randomized Controlled Trials- (한국인과 중국인에서 체온에 대한 고려삼과 화기삼의 영향 -이중맹컴 무작위배정 임상시험-)

  • Seo Jung Chul;Heo Zheng Jie;Han Sang Won;Lee Kyung Lim;Byun Joon Seok;Kim Myung Soo;Ha Il Do;Leem Kang hyun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.17 no.3
    • /
    • pp.837-841
    • /
    • 2003
  • In East-South Asia it has been widely known that Korean ginseng(Panax ginseng) increases body temperature, whereas American ginseng(Panax quinquefolius) decreases it. This study was designed to find out if Korean ginseng could increase body temperature comparing with American ginseng. Double-blind randomized controlled trials on body temperature of Korean ginseng and American ginseng in Koreans and Chineses was performed by using electronic thermometer at the ear. There was no significant difference between Korean ginseng and American ginseng in Koreans as well as Chineses by repeated-measures ANOVA. It was revealed that Korean ginseng does not increase body temperature. Maybe the concept that Korean ginseng increase body temperature is concerned with commercial interests dealing with American Ginseng.

Al-Fe Partitioning between Coexisting Garnet and Epidote from Metamorphic Rocks

  • Kim, Hyung-Shik;Kim, Young-Kyum;Jang, Young-Nam
    • The Journal of the Petrological Society of Korea
    • /
    • v.2 no.2
    • /
    • pp.63-73
    • /
    • 1993
  • The assemblage epidote and grandite garnet occurs in low-to medium-grade metabasites and calc schists of various geotectonic settings and in hydrothermally altered calcareous rocks in skarn deposits. The compositions of sixteen epidote-garnet paris have been analysed by means of electron microprobe. Al-Fe partitioning between coexisting grandite garnet and epidote is considered and measured at the grain boundaries on the supposition that the surface equilibrium was maintained in the following exchange reaction: 2$Ca_2Al_3Si_3O_12$(OH)+$Ca_3Fe_2Si_3O_12$=2$Ca_2A_l2FeSi_3O_12$(OH)+$Ca_3Al_2Si_3O_12$ Partition coefficients confirms the differences in thermal conditions between low-grade and medium-grade metamorphic rocks. $K_D$ values ($X_{$CO_2$}$=($Fe^{+3}$/Al)$^{Ep}$/($Fe^{+3}$/Al)$^{Gr}$, where Fe=$Fe^{+3}$) from greenschist facies rocks of the estimated metamorphic temperatures, 330~$390^{\circ}C$, range approximately between 0.02 and 0.17. Epidote-amphibolite facies rocks and calcareous skarns of the estimated temperatures, 400~$550^{\circ}C$, have $K_D$ values between 0.24 and 0.37. $K_D$ values from the rocks of the temperatures, 640~$700^{\circ}C$, range nearly between 0.58 and 0.75. The diagrams in Figs. 2 and 3 can serve as a mineralogic thermometer for relatively shallow rocks, assuming that the pressure dependence of partition coefficients for the iron-exchange reaction in the two minerals can be neglected.

  • PDF

I-Q Channel 12bit 1GS/s CMOS DAC for WCDMA (WCDMA 통신용 I-Q 채널 12비트 1GS/s CMOS DAC)

  • Seo, Sung-Uk;Shin, Sun-Hwa;Joo, Chan-Yang;Kim, Soo-Jae;Yoon, Kwang-S.
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.1
    • /
    • pp.56-63
    • /
    • 2008
  • This paper describes a 12 bit 1GS/s current mode segmented DAC for WCDMA communication. The proposed circuit in this paper employes segmented structure which consists of 4bit binary weighted structure in the LSB and 4bit thermometer decoder structure in the mSB and MSB. The proposed DAC uses delay time compensation circuits in order to suppress performance decline by delay time in segmented structure. The delay time compensation circuit comprises of phase frequency detector, charge pump, and control circuits, so that suppress delay time by binary weighted structure and thermometer decoder structure. The proposed DAC uses CMOS $0.18{\mu}m$ 1-poly 6-metal n-well process, and measured INL/DNL are below ${\pm}0.93LSB/{\pm}0.62LSB$. SFDR is approximately 60dB and SNDR is 51dB at 1MHz input frequency. Single DAC's power consumption is 46.2mW.

Development of Deep-Heating Stimulation System for Substituting the Heat Effect of Moxibustion (뜸의 열적효과를 구현하기 위한 심부 열 자극 시스템 개발)

  • Cha, Ji-Young;Myoung, Hyoun-Seok;Cho, Sung-Pil;Lee, Kyoung-Joung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.6
    • /
    • pp.50-57
    • /
    • 2009
  • In this paper, a deep-heating stimulation system and protocol were designed to substitute the heat effect of moxibustion. Moxibustion is used to increase immunity and cure disease. But, it is difficult to control power of heat stimulation. A designed deep-heating stimulation system using Radio-Frequency(RF) is easy to control power of heat stimulation. Also, the stimulation protocol for substitution of the heat effect of moxibustion is proposed. Core temperature was applied to infrared camera, thermometer, and infrared sensor, and then was compared with that of moxibustion. The proposed system showed that it is more effective than moxibustion in transferring heat effect in such a deep part. Also, it shows the possibility of usefulness of deep-heating stimulation system and heat stimulation protocol.