• Title/Summary/Keyword: Thermodynamics.

Search Result 432, Processing Time 0.034 seconds

INVESTIGATION ON MATERIAL DEGRADATION OF ALLOY 617 IN HIGH TEMPERATURE IMPURE HELIUM COOLANT

  • Kim, Dong-Jin;Lee, Gyeong-Geun;Jeong, Su-Jin;Kim, Woo-Gon;Park, Ji-Yeon
    • Nuclear Engineering and Technology
    • /
    • 제43권5호
    • /
    • pp.429-436
    • /
    • 2011
  • The corrosion of materials exposed to high temperature helium in a very high temperature reactor is caused by interaction with the impurities in the helium. This interaction then induces high temperature mechanical deterioration. By considering the effect of the impurity concentration on material corrosion, a long-term coolant chemistry guideline can be determined for the range of impurity concentration at which the material is stable for a long time. In this work, surface reactions were investigated by analyzing the thermodynamics and the experimental results for Alloy 617 exposed to controlled impure helium at $950^{\circ}C$. Moreover, the surfaces were examined for the Alloy 617 crept in air and in uncontrolled helium, which was explained by possible surface reactions.

혼합물의 열역학 (제1보). 이상기체 (Thermodynamics of Mixtures (I). Ideal Gases)

  • 윤창구
    • 대한화학회지
    • /
    • 제17권5호
    • /
    • pp.324-331
    • /
    • 1973
  • 이상기체 혼합물을 연속체의 물질역학과 비가역 변화의 열역학에서 개발된 방법으로 연구하였다. 자유 에너지의 함수 형태와 각개 성분의 기체법칙을 엔트로피 부등식으로부터 직접 유도하고 혼합물의 변형, 열 전도, 확산 및 화학반응이 받는 제약을 명시함으로서 앞으로 이 방법을 다른 물질들에 응용하는 데에 도움이 되도록 하였다.

  • PDF

In-Situ Diagnosis of Vapor-Compressed Chiller Performance for Energy Saving

  • Shin Younggy;Kim Youngil;Moon Guee-Won;Choi Seok-Weon
    • Journal of Mechanical Science and Technology
    • /
    • 제19권8호
    • /
    • pp.1670-1681
    • /
    • 2005
  • In-situ diagnosis of chiller performance is an essential step for energy saving business. The main purpose of the in-situ diagnosis is to predict the performance of a target chiller. Many models based on thermodynamics have been proposed for the purpose. However, they have to be modified from chiller to chiller and require profound knowledge of thermodynamics and heat transfer. This study focuses on developing an easy-to-use diagnostic technique that is based on adaptive neuro-fuzzy inference system (ANFIS). The effect of sample data distribution on training the ANFIS is investigated. It is found that the data sampling over 10 days during summer results in a reliable ANFIS whose performance prediction error is within measurement errors. The reliable ANFIS makes it possible to prepare an energy audit and suggest an energy saving plan based on the diagnosed chilled water supply system.

Transport Coefficients Across A Charged Mosaic Membrane III

  • Lee, Jungwoon;Minho Kang;Song, Myung-Kwan;Wongkang Yang;Lee, Jang-Woo
    • Korean Membrane Journal
    • /
    • 제5권1호
    • /
    • pp.61-67
    • /
    • 2003
  • Various characteristics of ion transport properties of a charged mosaic membrane with a parallel array of positive and negative functional charges were investigated, From the analysis of the volume flux, it was found that the salt flux based on nonequilibrium thermodynamics, preferential salt transport across the charged mosaic membrane. Transport properties of the magnesium sulfate(MgSO$_4$) and sucrose across the charged mosaic membrane were estimated. As a result, metal salts transport depended largely on the charged states and molecular weight otherwise nonelectrolyte solution was rejected under all experimental conditions. On the other hand, the reflection coefficient s indicated the negative value that suggested preferential material transport and was independent of charged mosaic thickness.

현열 축열조의 성능에 관한 엑서지 해석 (Exergy analysis on the storage performance of the sensible heat storage unit)

  • 김시범;권순석
    • 한국해양공학회지
    • /
    • 제2권1호
    • /
    • pp.176-182
    • /
    • 1988
  • The exergy analysis on the heat storage performance of the senible heat storage unit which consists of the heat storage material in the concentric annulus and the hot fluid flowing through the inner tube is performed. Heat transfer characteristics which are necessary for the performance of the exergy analysis is obtained from the energy balance equations and the second law of thermodynamics. As the index of heat storage performance, the exergy lossnumber $N_{s}$, and exergy storage ratio from the concepts of the second law of thermodynamics are defined. Results are ovtained for the grometry of the storage unit, the Biot number Bi, ambient temperature $T_{o}$ as parameters. From these results the exergy storage ratio can be considered as the efficiency of the hat storage unit and is introduced as a guide to design.

  • PDF

Bi 초전도 박막에서 단일상 형성을 위한 열역학 분석 (Analysis of Thermodynamics for Formation of Single Phase in Bi-superconducting Thin Films)

  • 천민우;박용필
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2002년도 춘계종합학술대회
    • /
    • pp.623-626
    • /
    • 2002
  • High quality BSCCO thin films have been fabricated by means of an ion beam sputtering at various substrate temperatures, Tsub, and ozone gas pressures, pO$_3$. The correlation diagrams of the BSCCO phases with Tsub and pO$_3$are established in the 2212 and 2223 compositional films. In spite of 2212 compositional sputterina Bi2201 and Bi2223 as well as Bi2212 phases come out as stable phases depending on Tsub and pO$_3$. From these results, the thermodynamic evaluation of ΔH and ΔS, which are related with Gibbs' free energy change for single Bi2212 or Bi2223 phase, was performed.

  • PDF

Smart Air Condition Load Forecasting based on Thermal Dynamic Model and Finite Memory Estimation for Peak-energy Distribution

  • Choi, Hyun Duck;Lee, Soon Woo;Pae, Dong Sung;You, Sung Hyun;Lim, Myo Taeg
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.559-567
    • /
    • 2018
  • In this paper, we propose a new load forecasting method for smart air conditioning (A/C) based on the modified thermodynamics of indoor temperature and the unbiased finite memory estimator (UFME). Based on modified first-order thermodynamics, the dynamic behavior of indoor temperature can be described by the time-domain state-space model, and an accurate estimate of indoor temperature can be achieved by the proposed UFME. In addition, a reliable A/C load forecast can be obtained using the proposed method. Our study involves the experimental validation of the proposed A/C load forecasting method and communication construction between DR server and HEMS in a test bed. Through experimental data sets, the effectiveness of the proposed estimation method is validated.

시동기의 정 출력 시동 기법에 의한 마이크로터빈 시동 구간의 운전 시뮬레이터 개발 (Simulator for a Micro-Turbine during Start-up by Constant Power Output Motoring Method using Starter)

  • 노민식
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.2028-2037
    • /
    • 2009
  • This paper presents the simulator for dynamic modeling of a MT(micro turbine) during start-up period. The simulator is implemented by modeling a dynamic power of main components of a MT including compressor, combustor and turbine. A modeling for a MT under steady state operation can be accurately built from thermodynamics analysis. But dynamic modeling during start-up period is very difficult because efficiency of main components is very low and the designed value has big error and nonlinear characteristics during start-up. In this paper, new method without using thermodynamics analysis during start-up is proposed for the simulator. The power models of main components are derived from analysis of the experimental operation data by test motoring using a electric starter under constant power output. The simulator is developed using MATLAB/Simulink. For constant power output control, sensorless vector inverter is designed and algorithms for starting from stall and method for controling a output power are proposed. The performance of developed simulator is verified by comparing experimental and simulation start-up results.

Thermodynamics for Formation of Each Stable Single Phase in BSCCO Thin Films

  • Yang, Sung-Ho;Park, Yong-Pil;Kim, Gwi-Yeol
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.104-107
    • /
    • 2000
  • High quality BSCCO thin films have been fabricated by means of an ion beam sputtering at various substrate temperatures, T$\_$sub/, and ozone gas pressures, PO$_3$. The correlation diagrams of the BSCCO Phases appeared against T$\_$sub/ and PO$_3$ are established in the 2212 and 2223 compositional films. In spite of 2212 compositional sputtering, Bi2201 and Bi2223 phases as well as Bi2212 one come out as stable phases depending on T$\_$sub/ and PO$_3$. From these results, the thermodynamic evaluations of ΔH and ΔS which are related with Gibbs' free energy change for single Bi2212 or Bi2223 phase are performed.

  • PDF

Salt-Induced Protein Precipitation in Aqueous Solution: Single and Binary Protein Systems

  • Kim, Sang-Gon;Bae, Young-Chan
    • Macromolecular Research
    • /
    • 제11권1호
    • /
    • pp.53-61
    • /
    • 2003
  • A molecular-thermodynamic model is developed for the salt-induced protein precipitation. The protein molecules interact through four intermolecular potentials. An equation of state is derived based on the statistical mechanical perturbation theory with the modified Chiew's equation for the fluid phase, Young's equation for the solid phase as the reference system and a perturbation based on the protein-protein effective two body potential. The equation of state provides an expression for the chemical potential of the protein. In a single protein system, the phase separation is represented by fluid-fluid equilibria. The precipitation behaviors are simulated with the partition coefficient at various salt concentrations and degree of pre-aggregation effect for the protein particles. In a binary protein system, we regard the system as a fluid-solid phase equilibrium. At equilibrium, we compute the reduced osmotic pressure-composition diagram in the diverse protein size difference and salt concentrations.