The purpose of this study was to observe the sealing ability and durability of All-Bond 2, Gluma Bonding System, Scotch bond 2 and Superbond D-liner which are dentin bonding agents used as desensitizing agents. The durability of the sealing ability of the materials were compared after 0, 140, 420, 840 tooth brushing strokes. 120 extracted teeth were divided into 5 groups and the agents were applied to the exposed dentin. No agents was applied on group I, the control group. Each specimen went through thermocycling from $5^{\circ}$ to $55^{\circ}C$, 200 times. Each group was devide into 4 subgroups and artificial tooth brushing strokes were done for 0, 140, 420, 840 times. Finally the specimens were stored in 0.5 % methylene blue solution for 24 hours in a incubator set at $37^{\circ}C$. The tooth were sectioned perpendicular to the long axis and the dye penetration ratio to the pulp was measured. The following results were obtained. 1. All four dentin bonding agents initially showed excellent sealing ability. 2. All-bond 2, Gluma Bonding System and Superbond D-liner showed durability of dentinal tubule sealing effect after 840 strokes(6-week) artificial tooth brushing. 3. Scotchbond 2 showed a significant decrease in sealing ability after 420 strokes(3-week) artificial tooth brushing. (P<0.05).
PURPOSE. This study aimed to evaluate the effect of surface treatments on bond strength of indirect composite material (Tescera Indirect Composite System) to monolithic zirconia (inCoris TZI). MATERIALS AND METHODS. Partially stabilized monolithic zirconia blocks were cut into with 2.0 mm thickness. Sintered zirconia specimens were divided into different surface treatment groups: no treatment (control), sandblasting, glaze layer & hydrofluoric acid application, and sandblasting + glaze layer & hydrofluoric acid application. The indirect composite material was applied to the surface of the monolithic zirconia specimens. Shear bond strength value of each specimen was evaluated after thermocycling. The fractured surface of each specimen was examined with a stereomicroscope and a scanning electron microscope to assess the failure types. The data were analyzed using one-way analysis of variance (ANOVA) and Tukey LSD tests (${\alpha}$=.05). RESULTS. Bond strength was significantly lower in untreated specimens than in sandblasted specimens (P<.05). No difference between the glaze layer and hydrofluoric acid application treated groups were observed. However, bond strength for these groups were significantly higher as compared with the other two groups (P<.05). CONCLUSION. Combined use of glaze layer & hydrofluoric acid application and silanization are reliable for strong and durable bonding between indirect composite material and monolithic zirconia.
Objectives: The aim of this in vitro study was to evaluate the bond strength of 2 universal adhesives used in different application modes to bleached enamel. Materials and Methods: Extracted 160 sound human incisors were used for the study. Teeth were divided into 4 treatment groups: No treatment, 35% hydrogen peroxide, 16% carbamid peroxide, 7.5% carbamid peroxide. After bleaching treatments, groups were divided into subgroups according to the adhesive systems used and application modes (n = 10): 1) Single Bond Universal, etch and rinse mode; 2) Single Bond Universal, self-etch mode; 3) Gluma Universal, etch and rinse mode; 4) Gluma Universal, self-etch mode. After adhesive procedures nanohybrid composite resin cylinders were bonded to the enamel surfaces. All specimens were subjected to shear bond strength (SBS) test after thermocycling. Data were analyzed using a 3-way analysis of variance (ANOVA) and Tukey post hoc test. Results: No significant difference were found among bleaching groups (35% hydrogen peroxide, 16% carbamid peroxide, 7.5% carbamid peroxide, and no treatment groups) in the mean SBS values. There was also no difference in SBS values between Single Bond Universal and Gluma Universal at same application modes, whereas self-etch mode showed significantly lower SBS values than etch and rinse mode (p < 0.05). Conclusions: The bonding performance of the universal adhesives was enhanced with the etch and rinse mode application to bleached enamel and non-bleached enamel.
Mostafavi, Azam Sadat;Memarian, Maryam;Seddigh, Mohammad Ali
The Journal of Advanced Prosthodontics
/
제13권1호
/
pp.65-70
/
2021
Purpose. Implant mechanical complications, including screw loosening, can influence dental implant success. It has been shown that torque values are affected by contamination occurred in implant-abutment (I/A) interface. This study aimed to examine the effects of blood, saliva, fluoride and chlorhexidine contamination on reverse torque values (RTVs) of abutment screws in oral conditions. Materials and Methods. 50 fixtures were mounted into the stainless-steel holders and divided into five groups (n = 10). Except control group (NC), fixture screw holes in other groups were contaminated with chlorhexidine (CG), saliva (SG), blood (BG), or fluoride (FG). Abutment screws were tightened with a digital torque meter. I/A assemblies were subjected to thermocycling and cyclic loading. The mean RTVs were recorded and data were analyzed with one-way ANOVA and Tukey test. Results. Except for specimens in SG (20.56 ± 1.33), other specimens in BG (21.11 ± 1.54), CG (22.89 ± 1.1) and FG (24.00 ± 1.12) displayed significantly higher RTVs compared to NC (19.00 ± 1.87). The highest RTVs were detected in CG and FG. Conclusion. The obtained data robustly suggest that RTVs were significantly affected by fluid contaminations. Specimens in FG and CG displayed the highest RTVs. Therefore, clinicians should have enough knowledge about probable contaminations in I/A interface in order to manage them during clinical procedure and to inform patients about using oral care products.
PURPOSE. The purpose of this study is to evaluate if pre-treatment with desensitizers have a negative effect on microtensile bond strength before cementing a restoration using recently introduced self-adhesive resin cement to dentin. MATERIALS AND METHODS. Thirty-five human molars' occlusal surfaces were ground to expose dentin; and were randomly grouped as (n=5); 1) Gluma-(Glutaraldehyde/HEMA) 2) Aqua-Prep F-(Fluoride), 3) Bisblock-(Oxalate), 4) Cervitec Plus-(Clorhexidine), 5) Smart protect-(Triclosan), 6) Nd:YAG laser, 7) No treatment (control). After applying the selected agent, RelyX U200 self-adhesive resin cement was used to bond composite resin blocks to dentin. All groups were subjected to thermocycling for 1000 cycles between $5-55^{\circ}C$. Each bonded specimen was sectioned to microbars ($6mm{\times}1mm{\times}1mm$) (n=20). Specimens were submitted to microtensile bond strength test at a crosshead speed of 0.5 mm/min. Kolmogorov-Smirnov, Levene's test, Kruskal-Wallis One-way Analysis of Variance, and Conover's nonparametric statistical analysis were used (P<.05). RESULTS. Gluma, Smart Protect and Nd:YAG laser treatments showed comparable microtensile bond strengths compared with the control group (P>.05). The microtensile bond strengths of Aqua-Prep F, and Cervitec Plus were similar to each other but significantly lower than the control group (P<.05). Bisblock showed the lowest microtensile bond strength among all groups (P<.001). Most groups showed adhesive failure. CONCLUSION. Within the limitation of this study, it is not recommended to use Aqua-prep F, Cervitec Plus and Bisblock on dentin when used with a self-adhesive resin cement due to the decrease they cause in bond strength. Beside, pre-treatment of dentin with Gluma, Smart protect, and Nd:YAG laser do not have a negative effect.
The purpose of this study was to investigate the effect of cavity configurations on the marginal leakage of class 5 glass ionomer cement and composite resin restorations. Four types of cavities such as saucer shape. notch shape. combined shape(notch shape occlusally and saucer shape gingivally). and U shape were prepared on the buccal and lingual surfaces of 80 extracted premolars(40 cavities for each shape). Occlusal cavity margins were placed at enamel and cervical margins were placed at dentin. 10 cavities of each shape were restored with Ketac Fil as a conventional glass ionomer cement. Fuji II LC improved as a resin modified glass ionomer cement, Z 100 as a hybrid composite resin. and Tetric Flow as a flowable composite resin (40 cavities for each material). After thermocycling, teeth were immersed in 5% basic fuchsin solution for 6 hours and sectioned longitudinally in a buccolingual direction through the center of the restoration. The dye penetrations at the tooth restoration interface were examined by stereomicroscope. The Result were as follows 1. In saucer shape, notch shape and combined shape, composite resin restorations showed lesser leakage than glass ionomer restorations(p<0.05) and in U shape. Tetric Flow showed the least marginal leakage and others were decreased as Z 100. Fuji II LC improved, Ketac Fil in that order. There were statistically significant difference between Tetric Flow and Fuji II LC improved. Ketac Fil and between Z 100 and Ketac Fil(p<0.05). 2. In Ketac Fil restoration group, saucer shape showed the highest marginal leakage and U shape showed the least marginal leakage and others were decreased as notch shape, combined shape in that order. There were statistically significant difference between saucer shape and combined shape, U shape and between notch shape and U shape(p<0.05). 3. In Fuji II LC improved restoration group, U shape showed the least marginal leakage. There were statistically significant difference between U shape and other three shapes(p<0.05). 4. The cavity configuration had no significant effect on marginal leakage of composite resin restorations(p>0.05).
An alternative design to conventional class II cavity preparation for proximal carious lesions is the tunnel preparation. It preserves the marginal ridge intact, thus making it possible to maintain the natural contact relationship with the adjacent tooth and minimize tooth reduction. This in vitro study was purposed to evaluate the effect of the materials' elastic constants and shear-bond strength on the marginal ridge fracture resistance of teeth restored by the tunnel technique, and to find the materials of choice for tunnel restorations. $Resinomer^{(R)}$, $Ketac-silver^{(R)}$, $Miracle-Mix^{(R)}$, and Tytin were used as restorative material. The elastic constants of each restorative material were evaluated by ultrasonic pulse measurement. Young's modulus and bulk modulus of the restorative materials were evaluated in three specimens for each material type. The shear-bond strength of the restorative materials to the dentin surface was measured after thermocycling 400 times between 6 and $60^{\circ}C$, using ten specimens for each material type. For measuring marginal ridge strength, 60 sound extracted molar teeth were distributed into six groups by size. Sound molar teeth were used as a Control group and unfilled prepared teeth were grouped as Unrestored. Another four groups were named Resinomer group, Ketac-Silver group, Miracle Mix group, and Tytin group by type of restorative material. Tunnel cavity preparation was done with ' 1/2, 2, and 4 round burs in sequence. Initial access to proximal surface was made through an occlusal access preparation started at least 2mm from the marginal ridge, and the proximal opening was formed about 2.5mm below the marginal ridge. After restoration and thermocycling, marginal ridge strength was measured using a universal testing machine. The results were as follows: 1. The Young's modulus of $Tytin^{(R)}$ was 63.95 GPa, followed by $Ketac-Silver^{(R)}$ 27.60 GPa, $Miracle-mix^{(R)}$ 18.48 GPa, and $Resinomer^{(R)}$ 10.74 GPa showing significant differences between the groups(P<0.05). The bulk modulus of the materials showed the same order as Young's modulus. The value of $Tytin^{(R)}$ showed 59.57 GPa indicating that it will deform less than other materials under the same stress. It was followed by $Ketac-Silver^{(R)}$ 23.57 GPa, Miracle $Mix^{(R)}$ 12.50 GPa, and $Resinomer^{(R)}$ 11.60 GPa. 2. The Resinomer group had a shear-bond strength of 7.41 MPa which was significantly higher than those of the Ketac-Silver group (1.80 MPa) and the Miracle Mix group (2.84 MPa) (P<0.01). All the specimens of Tytin group detatched from the dentin surface during thermocycling. 3. The mean marginal ridge strength of the Unrestored group(46.14 kgf) was significantly lower than that of the Control group (84.24 kgf) (P<0.01). The marginal ridge strength of teeth restored by the tunnel technique was, in order, Ketac-Silver group 74.06 kgf, Miracle Mix group 73.36 kgf, Resinomer group 63.47 kgf, and Tytin group 58.76 kgf. The Ketac-Silver, Miracle Mix, and Resinomer groups showed no significant difference with the Control group (P>0.05), but the Tytin group showed significantly lower strength compared to the Control group(P<0.05). The results showed that the marginal ridge strength of the teeth restored by the tunnel technique was not significantly lower than that of sound teeth. They also demonstrated that the bonding strength of the restorative material to the tooth surface should be high and the modulus of elasticity should not be lower than that of the tooth in order to restore the marginal ridge strength to its natural condition.
To evaluate the marginal leakage in Class V cavity this study has been undertaken to compare the sandwich technique with the conventional method, and find out the effect of lining material, lining method, and polishing time on sandwich technique. Ninty extracted teeth were divided into eight test groups and a control group, and were prepared with a buccal Class V cavity. Four test groups were lined with Dentin Cement whereas the other four test groups were lined with Vitrabond. Half of the either group were lined 0.5mm short of the carvosurface margin and the rest were lined completely to the carvosurface margin. The four subgroups were further divided into specimens which were polished immediately and 24 hours after resin filling. The polished specimens were immersed in $37^{\circ}C$, 0.5% methylene blue solution for 24 hous after thermocycling at $5^{\circ}C$ and $55^{\circ}C$, 200 times and buccolingually sectioned. The sectioned specimens were examined dye penetration under the light microscope. The following results were obtained, 1. At the enamel margin, the conventional method showed a lower microleakage than the sandwich technique. The difference between the control and Vitrabond group was statistically significant(P<0.05), but no difference between the control and Dentin Cement group, and between the lining materials was observed. 2. At the dentinal margin, the sandwich technique showed a significant lower amount of microleakage (P<0.05), but there was no significant difference between the lining materials. 3. Regardless of the lining material, lining method, and polishing time used, values of microleakage were significantly higher at the dentinal margin compared to the enamel margin(P<0.05). 4. In specimens till the cavosurface margin, microleakage at the dentinal margin was less with the light-cured base than with the chemically-cured base, but there was no siginificantly difference between the lining materials regarding the lining method and polishing time. 5. The lining material, lining method, and polishing time did not affect the amount of micro leakage in the sandwich technique(P<0.05).
The purpose of the study was to evaluate the marginal sealing effect of composite resin inlays according to the luting techniques and compare them to the conventional direct resin filling technique. 90 cavities of class V were prepared on the buccal surface of 90 extracted molar teeth, which were divided into four groups. Cavities of control group were directly filled with Scotchbond 2 and P - 50, and those of composite resin inlay groups were luted with one of the followings: Adhesive bond followed by Adhesive cement, All bond followed by Adhesive cement, Fuji - ionomer type L All the specimens were immersed in India ink dye solution for 7 days at $37^{\circ}C$ incubator after thermocycling between $5^{\circ}C$ and $60^{\circ}C$ and longitudinally sectioned with diamond disk inot two parts All the specimens were observed at the occlusal and gingival margins and statistical analysis was performed. The results were as follows: 1. Groups filled with composite resin inlay showed less marginal leakage than the group directly filled(p<0.01). 2. There was no significant difference in marginal leakage between composite resin inlay groups luted with Adhesive bond followed by Adhesive cement and the group luted with All bond followed by Adhesive cement(p>0.05). 3. At occlusal margins, Composite resin inlay group luted with Adhesive bond followed by Adhesive cement showed less marginal leakage than the group luted with Fuii ionomer type I(p<0.01). At gingival margins, composite resin inlay group luted with All bond followed by Adhesive cement showed less marignal leakage than the group luted with Fuji ionomer type I(P<0.01).
보철물을 기능적으로 평가하기 위해 임시 시멘트로 임시 합착을 한 경우 보철물 내면의 잔여 임시 시멘트는 레진 시멘트를 이용한 최종 합착에 있어서 부정적인 영향을 미칠 수 있다. 이에 본 연구는 다양한 임시 시멘트 제거 방법과 임시 시멘트의 잔여 성분이 임플란트 전용 레진 시멘트와 보철물의 유지력에 어떠한 영향을 미치는지를 알아보고자 하였다. 임플란트 지대주는 일반적인 시멘트 유지형 보철물 제작에 사용되는 높이 5.5 mm, 직경 4.5mm, 6도의 축면 경사도와 chamfer 변연을 갖는 기성품(Solid abutment, GSRAS4621, Osstem Implant Co., Busan, Korea)을 사용하였다. 40개의 주조시편을 제작하여 합착 전 70 psi하에 공기입자 분사법을 시행하였고, 10개의 시편을 임시 시멘트의 합착과정 없이 바로 최종 시멘트로 합착하여 대조군으로 설정하였으며 나머지 시편을 각 10개씩 임시 시멘트 제거를 위하여 오렌지 솔벤트를 이용한 군, 초음파 세척을 이용한 군, 공기입자 분사법을 이용한 군으로 나누었다. 임시 시멘트의 합착과 분리 후 제거과정을 거쳐 최종 시멘트로 임플란트 전용 시멘트($Premier^{(R)}$ Implant $Cement^{TM}$, Premier Co., PA, U.S.A.)를 사용하여 최종 합착을 실시하였다. 각 시편은 10분간 5 kg의 하중 하에 합착하였으며 열순환을 거쳐 만능시험기에서 분당 0.5 mm의 속도로 인장접착강도를 측정하였다. 측정이 끝난 뒤 모든 시편을 초음파 세척과 공기입자 분사법, 증기 세척의 과정을 통해 내면의 잔여 성분을 제거하였다. 완전 건조 후 비유지놀계 임시 시멘트를 사용하여 다시 임시 합착, 분리를 거친 후 동일한 실험 과정을 반복하였고 인장접착강도를 측정하여 다음의 결과를 얻었다. 오렌지 솔벤트를 사용한 군이 가장 작은 유지력을 나타냈으며 초음파 세척법을 사용한 군과 공기 입자 분사법을 사용한 군과 비교시 통계적으로 유의한 차이가 있었다(p<0.05). 초음파 세척법을 사용한 군과 공기 입자 분사법을 사용한 군 간의 비교시 통계적으로 유의한 차이가 없었다. 오렌지 솔벤트를 사용한 군은 대조군과 비교시 통계적으로 유의한 차이가 있었으며(p<0.05), 초음파 세척법을 사용한 군과 공기 입자 분사법을 사용한 군은 대조군과 비교시 통계적으로 유의한 차이가 없었다. 임시 시멘트의 유지놀 성분의 유무에 따른 비교시 통계적으로 유의한 차이가 없었다. 이상의 결과로부터 임시 시멘트 제거를 위해 오렌지 솔벤트만을 사용하는 것은 임플란트 전용 시멘트를 사용한 최종 합착시 유지력 감소의 원인이 될 수 있음을 알 수 있었으며, 임플란트 보철물 내면의 임시 시멘트를 효과적으로 제거하기 위한 방법으로 초음파 세척법, 공기 입자 분사법, 또는 이들의 복합적인 사용이 필요함을 알 수 있었다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.