Control of Impinging Jet Heat Transfer Using Mesh Screens (메쉬 스크린을 이용한 충돌제트 열전달 제어에 관한 연구)

  • Jo, Jeong-Won;Lee, Sang-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.5
    • /
    • pp.722-730
    • /
    • 2001
  • The local heat transfer of an axisymmetric submerged air jet impinging on a heated flat plate is investigated experimentally with the variation of mesh-screen solidity. The screen installed in front of the nozzle exit modifies the flow structure and local heat transfer characteristics. The mean velocity and turbulence intensity profiles of streamwise velocity component are measured using a hot-wire anemometry. The temperature distribution on the heated flat surface is measured with thermocouples. The smoke-wire flow visualization technique was employed to understand the near-field flow structure qualitatively for different mesh screens. Large-scale toroidal vortices and high turbulence intensity enhance the heat transfer rate in the stagnation region. For a higher solidity, turbulence intensity become higher which increases the local heat transfer at small nozzle-to-plate spacings such as L/D<6. The local and average Nusselt numbers of impinging jet from the $\sigma$(sub)s=0.83 screen at L/D=2 are about 5.6∼7.5% and 7.1% larger than those for the case of no screen, respectively. For the nozzle-to-plate spacings larger than 6, however, the turbulence intensities for all tested screens approach to an asymptotic curve and the mean velocity along the jet centerline decreases monotonically. As the nozzle-to-plat spacing increases for high solidity screens, the heat transfer rate decreases due to the reduction in turbulence intensity and jet momentum.

Experimental Study on Heat Transfer Characteristics of Swirling Impinging Jet (스월 충돌제트의 열전달 특성에 관한 실험적 연굴)

  • Jo, Jeong-Won;Lee, Sang-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.10
    • /
    • pp.1346-1354
    • /
    • 2001
  • The heat transfer characteristics off swirling air jet impinging on a heated flat plate have been investigated experimentally. The main object is to enhance the heat transfer rate by increasing turbulence intensity of impinging jet with a specially designed swirl generator. The mean velocity and turbulent intensity profiles of swirling jet were measured using a hot-wire anemomety. The temperature distribution on the heated flat surface was measured with thermocouples. As a result the swirl effect on the local heat transfer rate on the impinging plate is confined mainly in the small nozzle-to-plate spacings such as L/D<3 at the stagnation region. For small nozzle-to-plate spacings, the local heat transfer in the stagnation region is enhanced from the increased turbulence intensity due to swirl motion, compared with the conventional axisymmetric impinging jet without swirl. For example, the local Nusselt number of swirling jet with swirl number Sw=0.75 and Sw=1 is about 9.7-76% higher than that of conventional impinging jet at the radial location of R/D=0.5. With the increase of the nozzle-to-plate distance, the stagnation heat transfer rate is decreased due to the diminishing axial momentum of the swirling jet. However, the swirling impinging jet for all nozzle-to-plate spacings tested in this study does not enhance the average heat transfer rate.

A Study on Thermal Ratcheting Structure Test of 316L Test Cylinder (316L 시험원통의 열라체팅 구조시험에 관한 연구)

  • Lee, H.Y.;Kim, J.B.;Koo, G.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.243-249
    • /
    • 2001
  • In this study, the progressive inelastic deformation, so called, thermal ratchet phenomenon which can occur in high temperature liquid metal reactor was simulated with thermal ratchet structural test facility and 316L stainless steel test cylinder. The inelastic deformation of the reactor baffle cylinder can occur due to the moving temperature distribution along the axial direction as the hot free surface moves up and down under the cyclic heat-up and cool-down of reactor operations. The ratchet deformations were measured with the laser displacement sensor and LVDTs after cooling the structural specimen which experiences thermal load up to $550^{\circ}$ and the temperature differences of about $500^{\circ}C$. During structural thermal ratchet test, the temperature distribution of the test cylinder along the axial direction was measured from 28 channels of thermocouples and the temperatures were used for the ratchet analysis. The thermal ratchet deformation analysis was performed with the NONSTA code whose constitutive model is nonlinear combined kinematic and isotropic hardening model and the test results were compared with those of the analysis. Thermal ratchet test was carried out with respect to 9 cycles of thermal loading and the maximum residual displacements were measured to be 1.8mm. It was shown that thermal ratchet load can cause a progressive deformation to the reactor structure. The analysis results with the combined hardening model were in reasonable agreement with those of the tests.

  • PDF

Effects of the Wire-screen Rib on Heat Transfer and Friction Factors (와이어 스크린 리브이 열전달과 마찰계수에 미치는 효과)

  • Oh, Se-Kyung;Ahn, Soo-Whan;Lee, Dae-Hee
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.2
    • /
    • pp.196-203
    • /
    • 2011
  • Experiments to determine heat transfer coefficients and friction factors are conducted on a stationary transverse parallel wire-screen rib roughened rectangular channel. The test section consists of 198 mm (W) x 40 mm (H) x 712 mm (L). The channel has the aspect ratio of 4.95 and hydraulic diameter of $D_h$=6.66 cm. Four wire screen ribs and a solid rib are used. 0.1 mm-thick-stainless steel foil heaters and thermocouples (T type) are used to measure the heat transfer coefficients. Reynolds numbers studied range from 20,000 to 60,000. The wire-screen rib height (e) to hydraulic diameter ($D_h$) ratio ($e/D_h$) is 0.075; spacing (p) to height ratio (p/e) is 10. Results indicate that the solid rib produces the greatest Nusselt number and friction factor.

Statistical Analysis on Residuals from No-Fault Reference Models of a Residential Heat Pump System in Normal Cooling Operation (가정용 열펌프 시스템의 정상냉방 운전조건에서 기준모델에 의한 잔차의 통계적 분석)

  • Kim, Min-Sung;Yoon, Seok-Ho;Baik, Young-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1351-1358
    • /
    • 2011
  • To approximate the threshold of the fault detection and diagnosis (FDD) system, validation of the measurements is mandatory. Naturally, the system shows uncertainties due to measuring sensors - mostly thermocouples or RTDs - and due to repeatability. The uncertainty of a thermocouple comes from natural variation or a drift of the thermocouple measurement. Considering the natural variation behaves like zero-mean white noise, its natural variation can be characterized closely by the steady-state standard deviation. However, residuals between measurements and no-fault references in FDD systems show a statistical distribution with various uncertainties. In this paper, steady-state variations of measurement residuals were investigated by utilizing built-in temperature sensors in a heat pump for the model development and the final application.

Investigation of Material Characteristics of Reinforced Concrete Beam After Exposure to Fire Test (화재 실험에 따른 철근 콘크리트 보의 재료특성 연구)

  • Ju, Min-Kwan;Park, Cheol-Woo;Oh, Ji-Hyun;Seo, Sang-Gil;Shim, Jae-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.3
    • /
    • pp.33-41
    • /
    • 2016
  • Concrete is inherently a good fire-resistance material among all other constrcution materials and protects the reinforcing steel inside. This study investigates the material characteristics of concrete and steel bar inside the full scale reinforced concrete(RC) beam exposed to fire test. The fire test specimen was 4 m long and the test was conducted under no loading condition following KS F 2257. Fire source is simulated by ISO 834 and number of thermocouples were installed to measure temperature variation of surfaces and inside of the beam. The measured compressive strength of cored specimen, which was exposed to fire test, was 11 MPa, about 66% lower than the strength before exposure. The yielding strength of steel bar also decreased about 75 MPa, about 17% lower. The measured temperature of protected steel bar was around $649^{\circ}C$, the critical limit, after 4 hour exposure.

Study on the Temperature Separation Phenomenon in a Vortex Chamber (와류실의 온도 분리 현상에 대한 연구)

  • Ye, A Ran;Zhang, Guang;Kim, Heuy Dong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.9
    • /
    • pp.731-737
    • /
    • 2014
  • A vortex chamber is a simple device that separates compressed gas into a high-temperature stream and a low-temperature stream. It is increasing in popularity as a next-generation heat exchanger, but the flow physics associated with it is not yet well understood. In the present study, both experimental and numerical analyses were performed to investigate the temperature separation phenomenon inside the vortex chamber. Static pressures and temperatures were measured using high-sensitivity pressure transducers and thermocouples, respectively. Computational fluid dynamics was applied to simulate 3D unsteady compressible flows. The simulation results showed that the temperature separation is strongly dependent on the diameter of the vortex chamber and the supply pressure at the inlet ports, where the latter is closely related to the viscous work. The previous concept of a pressure gradient wave may not be a reasoning for temperature separation phenomenon inside the vortex chamber.

The Study on Surface Fire Spread in Fuel Bed (Fuel Bed에서의 지표화 확산에 관한 연구)

  • Kim, Jeong-Hun;Kim, Eung-Sik;Kim, Dong-Hyun;Kim, Jang-Whan
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.22-27
    • /
    • 2014
  • In this study a Fuel bed where surface fire spreads through is made to measure the data such as the flame height, radiation, spread rate and temperature distribution of Fuel bed. As experimental variables species of trees, wind velocities and slop are chosen. Fallen leaves of Quercus Variabilis (Q.V.) and Pinus Densiflora (P.D.) are used as fuel. Wind velocity is controlled by simply designed wind turnnel from 1 to 5 m/s. Slope of fuel bed is changed from $0^{\circ}$ to $30^{\circ}$. For the measurements of temperature distribution and spread rate total 35 of K-type 1.6 mm thermocouples are positioned as a lattice design. Radiant heat flow meters are used besides video camera and thermovision camera.

Prediction Equations for Internal Temperature and Yields of Chicken Patties During Deep Fat Frying (닭고기 Patty를 튀길 때 Patty 내부온도와 수율 예측)

  • Yi, Young-Hyoun;Chen, T.C.
    • Korean Journal of Food Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.157-160
    • /
    • 1991
  • Copper constantan thermocouples connecting to a recording potentiometer were inserted at the center of the patties and the samples were fried. In general, the internal temperature of the patty samples increased approximately $11.1^{\circ}C$ after the samples were removed from the fryer. The desired internal temperature and maximum internal end-point temperature, at different frying temperatures, can be obtained by adjusting the frying time. The yields of the patties decreased as maximum internal end-point temperature increased or as frying time increased. The internal temperature and maximum internal end-point temperature of the patty samples at three frying temperatures were predicted using polynominal regression of a third-order model with one independent variable, frying time. Polynominal regression of a second-order model with maximum internal end-point temperature as the independent variable was used to predict frying yields at three frying temperatures.

  • PDF

Portable thermocouple thermometer on the nonlinearity compensation (비선형 특성을 보정한 휴대용 열전대 온도계)

  • Kim, Seong-Kuk;Song, Jae-Won
    • Journal of Sensor Science and Technology
    • /
    • v.4 no.1
    • /
    • pp.21-28
    • /
    • 1995
  • A portable type K thermocouple thermometer is designed and fabricated to compensate the linearity to the high temperature $1000^{\circ}C$. The problems to be solved, which use a thermocouple thermometer are the compensation of the nonlinearity characters and reference compensation. The nonlinear character of the thermocouple is compensated, using an EPROM, and the reference compensation done using an IC AD595A. Before this compensation, there was the maximum error of $23.6^{\circ}C$(2.69%) at $876^{\circ}C$. However the results measured by the portable type K thermocouple thermometer fabricated show the character of the error of ${\pm}2^{\circ}C$(0.2%) in the range of the total temperature. This character satisfies the precision specifications of the type K thermal sensors in the range available $1000^{\circ}C$, which can be measured by the use of type K thermocouples. Therefore the portable type K thermocouple thermometer fabricated can be comparatively exactly used for the wide range of temperature of interest. Then this technique of compensating the nonlinear characters can be applied to the other kinds of thermal sensor compensation.

  • PDF