• 제목/요약/키워드: Thermo

검색결과 2,366건 처리시간 0.038초

Production of Transgenic Orchardgrass Overexpressing a Thermotolerant Gene, DgP23 (내열성 유전자 DgP23을 도입한 형질전환 오차드그라스의 생산)

  • Kim Ki-Yong;Jang Yo-Soon;Park Geun Je;Choi Gi Jun;Seong Byung Ryul;Seo Sung;Cha Joon-Yung;Son Daeyong
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • 제25권4호
    • /
    • pp.267-274
    • /
    • 2005
  • To develop transgenic orchardgrass (Dactylis glomerata L.) resistant to high temperature, a thermptolerance gene, DgP23, was introduced into orchardgrass using Agrobacterium - mediated transformation method. PCR and Southern blot analyses using genomic DNA showed specific DNA band on agarose gel and hybridization signal on X- ray film in transgenic orchardgrass harboring the recombinant DgP23 gene, but not in the wild type and empty vector control plants. RT-PCR and Southern blot analyses using total RNA also showed specific DNA band and hybridization signal. Transgenic orchardgrass did not showed ny morphological aberration both in the green house and field cultivation. Thermotolerance of transgenic plants was not detected in laboratory test. but may detected in field test.

Study on the Superplasticity in Al-Li Alloy Systems (AI-Li계 합금의 초소성에 관한 연구)

  • Jin, Y.C.;Kook, J.S.;Kim, Y.S.;Hong, E.S.;Lee, M.S.;Lee, M.H.;Yoo, C.Y.
    • Journal of the Korean Society for Heat Treatment
    • /
    • 제5권1호
    • /
    • pp.41-49
    • /
    • 1992
  • The effects of alloying elements on the superplastic properties of Al-Li based alloys had been investigated. The intermediate thermo-mechanical treated (ITMT) Al-2.0wt%Li, Al-2.0wt%Li-1.0wt%Mg, Al-2.0wt%Li-0.12wt%Zr and Al-2.0wt%Li-1.2wt%Cu-1.0wt%Mg-0.12wt%Zr alloys were tested in tension at various temperature (400, 450, 500 and $550^{\circ}C$) and strain rate($6.7{\times}10^{-3}$, $1.0{\times}10^{-2}$, $1.6{\times}10^{-2}$ and $5.0{\times}10^{-2}/sec$). The results were as follows : The superplasticity in binary, ternary and pentanary alloys appeared at 500 to $550^{\circ}C$, and good strain rate for superplasticity. $1.6{\times}10^{-2}/sec{\sim}1.0{\times}10^{-2}/sec$ for a binary alloy and $1.0{\times}10^{-2}/sec{\sim}6.7{\times}10^{-3}/sec$ for ternary and pentanary alloys. A Zr-added ternary alloy had best value of elongation (730%) in four alloys at $550^{\circ}C$ of tension temperature and $1.0{\times}10^{-2}/sec$ of strain rate. The strain rate was greatly dependent on tension temperature and true strain rate was more than 1.0 at all test temperature and strain rate. In binary and Mg-added teranry alloys. the necks were slightly formed and their fracture surface had lips shape, but Zr-added ternary and pentanary alloy fractured along the grain boundary without necking. Their dislocations moved to grain boundary during superplasticity deformation and arranged perpendicular to grain boundary. Super plastic deformation was made by grain boundary slip of dislocation slip creep and model of core and mantle.

  • PDF

Development of Integrated Wireless Sensor Network Device with Mold for Measurement of Concrete Temperature (콘크리트 온도 측정을 위한 거푸집 일체형 무선센서네트워크 장치 개발)

  • Lee, Sung Bok;Park, Seong Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • 제16권5호
    • /
    • pp.129-136
    • /
    • 2012
  • Temperature of fresh concrete can be effectively used to predict the strength of concrete being cured and make an informed decision for stripping the molds. A hygrothermograph and thermo-couple sensors that require an extensive wiring have been applied to measure a temperature of concrete at the early stage of the curing process on site. However, these methods have limits to provide the temperature data in real time due to harsh working environment including frequent cutting of wires. Therefore, this study is aiming at developing a device based on wireless sensor network to measure the temperature of concrete being cured in formwork. The result showed that the wireless sensor with probe type thermistor which is developed had the same temperature data compared to the existed wire type thermistor, and we confirmed the temperature history of concrete in real time for 28 days throughout the gateway by wireless network that collects the temperature data measured from specimens in laboratory. Also, the network device for transmission can be easily separated from the probe sensor part and reused consistently. If the wireless sensor network device developed uses in the field, the temperature management of concrete will be systematically conducted from at the early stage of the curing, and especially be effective for cold weather concrete construction. In addition, it will contribute to the establishment of advanced quality control system for concrete and productivity of supervisors on site will be increased in the future.

Thermal and Water Transmission Properties of Vapor Permeable Water Repellent Fabrics and Thermal Insulation Batting Materials (투습발수직물과 보온단열소재의 열 및 수분전달 특성)

  • Cho Gil Soo;Choi Jong Myoung;Lee Jung Ju;Lee Sern Woo
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • 제16권2호
    • /
    • pp.237-244
    • /
    • 1992
  • The purpose of this study was to comparatively evaluate thermal and water transmission properties of several vapor permeable water repellent (VPWR) fabrics and synthetic battings that became available in recent years. Five VPWR fabrics evaluated were Hipora in three coating variants, $Gore-Tex^{\circledR}$ and $Aitace^{\circledR}$. Battings evaluated were $Viwarma^{\circledR}$, $Uniwarmr^{\circledR}$, $Thinsulate^{\circledR}$, and $Airseal^{\circledR}$ Thermal resistance and water vapor transmission were measured for each fabric and batting and in all combinations. Thermal resistance at zero and 37 cm/sec air velocity was determined by the Thermo Labo II technique for simultaneously measuring conduction and radiation heat transfer. Water vapor transmission over 24 hours was measured by a modified weight-gain method in a compact humid chamber at conditions simulating the clothing climate under heavy exercise ($40{\pm}1^{\circ}C$, $90{\pm}2\%$ R.H., and 0.5 m/sec air velocity). Fabric porosity was calculated from fiber density and fabric weight, thickness, and area. Thermal resistance results for the fabrics showed the effectiveness of coatings in inhibiting heat transfer. Measurements taken in wind were: $31.1\~37.6\%$ for $Hipora^{\circledR}$ variants; $31.0\%$ for $Gore-Tex^{\circledR}$; and $18.4\%$ for $Aitaca^{\circledR}$ Measurements without wind were higher but in the same order. Water vapor transmission results were in reverse order: $Aitac^{\circledR}$, $8.8 kg/m^{2};\;Gore-Tex^{\circledR}$, 6.4 kg/$m^{2}$; and $Hipora^{\circledR},\;4.4\~6.0\;kg/m^{2}$. In general thermal resistance increased with porosity. For battings, the thermal resistance with wind results were: $Viwarmu^{\circledR}$, $65.0\%;\; Thinsulate^{\circledR}$, $62.0\%$; $Uniwarm^{\circledR}$, $61.0\%$; and $Airseala^{\circledR},\;53.1\%$. Thermal resistance was proportional to thickness. Thermal resistance of fabric-batting combinations were $20\%$ higher than those of the battings only. Water vapor transmission for combinations was mainly affected by that for the VPWR fabric used.

  • PDF

Efficacy of Cooling Vests for Alleviating Heat Strain of Farm Workers in Summer (여름철 농민의 서열 부담 경감을 위한 냉각조끼의 성능 평가)

  • Choi Jeong-Wha;Kim Myung-Ju;Lee Joo-Young
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • 제29권8호
    • /
    • pp.1176-1187
    • /
    • 2005
  • The purpose of this study was to evaluate the efficiency of cooling vests developed for farm workers harvesting red pepper in summer. The study was performed using the following two steps: 1) Climatic chamber test, 2) Field test. For the chamber test, a work environment was simulated as $33^{\circ}C$ and $65\%$RH, and the thermo-physiological and subjective responses were measured with and without cooling vests. Twelve young males participated as subjects. For the field test, three farmers participated while harvesting red pepper on the form, in summer. The measurements used were same as in the chamber test. Subjects were tested without any cooling vests, as a control. They were tested wearing vests with 2 frozen gel packs (CV2: Cooling area, $308cm^2$), and vests with 4 frozen gel packs (CV4: Sooting area, $616cm^2$). As a result of the chamber test, rectal temperature($T_{re}$) and mean skin temperature( $T_{sk}$) were lower in both CVs than in Control, and this tendency was statistically significant in CV4 (p<.05). Clothing microclimate temperature ($T_{clo}$) and total sweat rate (TSR) were significantly lower when wearing cooling vests (p<.05) Heart rate (HR) was also lower in wearing cooling vests than in Control, and the speed of recovery to the comfort level was faster when the subjects wore cooling vests. In addition, subjects felt 'less hot, less humid, and less uncomfortable' in both CVs than in Control. Field tests showed a similar tendency with the chamber tests. In particular, wearing the cooling vest was effective in restraining the raise of $T_{clo}$ on the back. It can be concluded that the cooling vest was effective in alleviating heat strain and discomfort in both the chamber test and the field test, despite the cooling area of the cooling vest being just $3.4\%$ of the body surface area ($616cm^2$).

Effects of NaCl/H3PO4 Flame Retardant Treatment on Lyocell Fiber for Thermal Stability and Anti-oxidation Properties (NaCl/H3PO4 내염화 처리가 라이오셀 섬유의 열 안정 및 내산화 특성에 미치는 영향)

  • Kim, Eun Ae;Bai, Byong Chol;Jeon, Young-Pyo;Lee, Chul Wee;Lee, Young-Seak;In, Se Jin;Im, Ji Sun
    • Applied Chemistry for Engineering
    • /
    • 제25권4호
    • /
    • pp.418-424
    • /
    • 2014
  • The improved thermal stability and anti-oxidation properties of Lyocell fiber were studied based on flame retardant treatment by using NaCl/$H_3PO_4$ solution. The optimized conditions of flame retardant treatment were studied on various maxing ratio of NaCl and $H_3PO_4$ and the mechanism was proposed through experimental results of thermal stability anti-oxidation. The IPDT (integral procedural decomposition temperature), LOI (limited oxygen index) and $E_a$ (activation energy) increased 23, 30 and 24% respectively via flame retardant treatment. It is noted that thermal stability and anti-oxidation improved based on char and carbon layer formation by dehydrogenation and dissociation of C-C bond resulting the hindrance of oxygen and heat energy into polymer resin. The optimized conditions for efficient flame retardant property of Lyocell fiber were provided using NaCl/$H_3PO_4$ solution and the mechanism was also studied based on experimental results such as IDT (initial decomposition temperature), IPDT, LOI and $E_a$.

Preparation and Heating Characteristics of N-doped Graphite Fiber as a Heating Element (질소가 도핑 된 흑연섬유 발열체의 제조 및 발열특성)

  • Kim, Min-Ji;Lee, Kyeong Min;Lee, Sangmin;Yeo, Sang Young;Choi, Suk Soon;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • 제28권1호
    • /
    • pp.80-86
    • /
    • 2017
  • In this study, nitrogen functional groups were introduced on graphite fiber (GF) to modify their electrical properties, and heating properties were investigated according to the treatment conditions. GF was prepared by a thermal solid-state reaction at $200^{\circ}C$ for 2 h. Surface properties of the nitrogen doped GF were examined by XPS, and its resistance and heating temperature were measured using a programmable electrometer and thermo-graphic camera, respectively. The XPS result showed that the nitrogen functional groups on the GF surface were increased with increasing of urea contents, and the heating property of the GF was also improved as nitrogen functional groups were introduced. The maximum heating temperature of GF treated by urea was $53.8^{\circ}C$ at 60 V, which showed 55% improved heating characteristics compared to that of non-treated GF. We ascribe this effect to introduced nitrogen functional groups on the GF surface by thermal solid-state reaction, which significantly affects the heating characteristics of GF.

Neutron Dose Measurements Using TLDs in a 252Cf Neutron Field (252Cf 중성자장에서 열형광선량계(TLD)를 이용한 중성자 방사선량 측정)

  • Chang, Insu;Kim, Sang In;Lee, Jung Il;Kim, Jang Lyurl;Kim, Bong Hwan
    • Journal of Radiation Protection and Research
    • /
    • 제38권1호
    • /
    • pp.37-43
    • /
    • 2013
  • In case of neutron dose measurement using TLDs (thermo-luminescence dosimeters), because the neutron energy dependence of the TLD is very high, the calibration of the energy response according to the characteristics of the neutron spectrum of workplace is required. In the present study, the ambient dose equivalent rates inside and around the Long-Counter (neutron detector) with narrow and complex inside in the neutron field of $^{252}Cf$ were evaluated. The calibration factors to account for the neutron energy dependence of TLDs were established for both the bare and $D_2O$ modulated $^{252}Cf$ neutron beams, respectively. The values of the TLD's measurement were compared with the computational results of the MCNPX (Monte Carlo N-Particles transport code). When using the two calibration factors of the TLD than a single calibration factor, the measured and the calculated values at the point of verification outside and inside the Long-Counter were in more good agreement. This results show that TLD should be calibrated in the reference neutron field similar to workplace situation.

Comparative Study of the Rheologic Properties of Elastic Impression Materials (수종 고무인상재의 유변학적 특성에 관한 비교)

  • Hong, Jun-Won;Ahn, Seung-Geun;Park, Ju-Mi;Song, Kwang-Yeob
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • 제25권1호
    • /
    • pp.31-40
    • /
    • 2009
  • The rheologic properties of elastic impression materials is a very important role as taking high accuracy impression. But, the studies that are focused on the rheologic properties of Korean elastic impression materials are not sufficient. The purpose of this study is to help clinical high accuracy impression taking by testing rheologic properties of elastic impression material that is made by Korea and other countries. Six type III elastic impression materials are tested. Subjects are 2 Korean polyvinylsiloxane(PVS), 2 imported PVS, 1 polyether, and 1 polysulfide. HAAKE RheoStress $1^{(R)}$(Thermo Electron Co. Germany)is used in measuring. HAAKE RheoStress $1^{(R)}$ is plate to plate type rheometer. All subjects is tested 3 times and measuring time is 900 seconds. We measured G′ and loss tangent after mixing. All elastic impression materials had a sigmoid shape on increasing G′ by time and decreasing loss tangent after setting, maximum G' is appeared highest in polyether, and lowest in polysulfide. Initial loss tangent is highest in polyether, and is lowest in Koreans PVS. Significant difference is showed in initial loss tangent between Korean PVS and imported PVS.

Reaction Rate Analysis of Combustion for Indonesian Coal Char Applied by External/Internal Diffusion (외부 및 내부 확산을 적용한 인도네시아 석탄촤의 연소 반응율 분석)

  • Hwang, Chan-Won;Kim, Ryang-Gyoon;Ryu, Kwang-Il;Wu, Ze-Lin;Jeon, Chung-Hwan
    • Korean Chemical Engineering Research
    • /
    • 제52권1호
    • /
    • pp.133-140
    • /
    • 2014
  • The experiment was designed to compare the char combustion kinetics of pulverized Indonesia coals commonly utilized in Korea power plants. The reaction rate of coal char has been formulated using the external and internal effectiveness factors to describe the diffusion effect quantitatively. The Random Pore Model (RPM) was used for applying internal specific surface area as a function of carbon conversion ratio. Reaction rate was obtained from reaction time using the Wire Heating Reactor (WHR) which can heat and measure the char particle temperature at the same time. BET and TGA were used to obtain physical properties such as internal specific surface area and structural parameter. Three kinds of Indonesia Sub-bituminous coals "BARAMULTI, ENERGYMAN, AGM" were used in order to derive the activation energy and pre-exponential factor. The results of this study showed that the effect of internal diffusion than that of external diffusion is the dominant as comparison of kinetics was reflected in external and internal effectiveness factors. For three kinds of coal char, finally, activation energy of intrinsic kinetics indicates 110~118 kJ/mol.