• 제목/요약/키워드: Thermal-load

검색결과 1,834건 처리시간 0.024초

태양열 난방 일체형 복합시스템의 축열조 효율개선에 관한 연구 (The Study on Efficiency Improvement of Thermal Storage Tank for Solar Combined Heating System)

  • 류남진;고광수;한유리;박윤철
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.188-192
    • /
    • 2006
  • This study is conducted to improve efficiency of thermal storage tank. The thermal storage tank was designed to store heat energy that obtained from solar or the others heat sources. However, it has difficulties in storing heat with uniform temperature through the entire tank with respect to vertical direction. This kind of maldistribution of the supplied heat to the storage tank effects on the system performance. In this study is focused on utilization of the thermal stratification to improve thermal comfort for people in the house. To enhance temperature stratification of the tank, a distributor was designed and Installed in the middle of the tank. The distributor is supplies hottest water to the top side of the tank which is very close to inlet of the supply line to the heating load. The hottest water that is accumulated on top side of the tank is firstly supplied to the load with higher temperature. Reminder water takes a little time to warming up until desired supply temperature reached. This kind alternating selection of the supply temperature is improve thermal comfort with moderated system performance.

  • PDF

Thermal catalytic de-NOX 공정에서 첨가제가 촉매의 활성에 미치는 영향에 관한 연구 (Effect of Additives on Catalytic Activity in Thermal Catalytic De-NOx Process)

  • 이진구;김태원;최재순;김정호;이재수;장경욱;박해경
    • 한국대기환경학회지
    • /
    • 제15권3호
    • /
    • pp.249-255
    • /
    • 1999
  • We sdudied effect of additives on catalytic activity in thermal catalytic de-NOx process which was composed of thermal reduction, catalytic reduction and catalytic oxidation stage. Pd-Pt/${\gamma}$-$Al_2O_3$ catalysts with the addition of transition metals(Co, Cu, Fe, Ni, W, Zn, Zr) and rare earth metals(Ce, Sr) were prepared by the conventional washcoating method. Those catalysts were characterized by CO pulse chemisorption, ICP, $N_2$ adsorption, SEM and XRD. The effect of catalyst additives on NOx removal for diesel emission was studied in thermal catalytic de-NOx process at reduction temperature(350~50$0^{\circ}C$), space velocity(5,000~20,000 $hr^{-1}$) and the engine load(0~120kW). The concentraton of CO, $CO_2$, NO and $NO_2$ in the exhaust gas increased with the engine load. On the other hand the concentration of $O_2$ decreased. The de-NOx activityof all prepared catalysts increased with respect to high CO and low $O_2$ level in the thermal reduction stage of the process. Insertion of Ce to Pt-Pd/${\gamma}$-$Al_2O_3$ catalyst showed the best activity of all the catalysts under these experimental conditions. De-NOx catalysts are effective to remove CO in addition to NOx in the catalytic reduction stage.

  • PDF

Stress wave법에 의한 열적 열화된 목재의 휨탄성계수 예측 (Estimating MOE of Thermal Degraded Wood by Stress Wave Method)

  • 이전제;김정원
    • Journal of the Korean Wood Science and Technology
    • /
    • 제26권3호
    • /
    • pp.9-15
    • /
    • 1998
  • The strength and stiffness of structures would be weakened by thermal degradation of wood members which are exposed to a variety of heat including a fire. For this reason, thermal degraded wood members can't pertinently support the load. However, it is easy to repair or rehabilitate wood structures. So, the degraded wood members which can't support the load can be replaced with new members. For the sake of this advantage, there is a need for nondestructive evaluation(NDE) technique, which is very effective to assess wood members in service. In this paper, it was considered whether the stress wave method is adequate to estimate static bending MOE of thermal degraded wood. As the result, the relationship between static bending MOE and MOEsw in elevated temperature was found out significant. Therefore, the application of stress wave method for estimating static bending MOE of thermal degraded zzwood would be possible. However, it is thought that further research for the effects of exposure temperature, time, and thermal degradation on the relationship between static bending MOEb and MOEsw would be needed.

  • PDF

Dynamic Thermal Rating of Overhead Transmission Lines Based on GRAPES Numerical Weather Forecast

  • Yan, Hongbo;Wang, Yanling;Zhou, Xiaofeng;Liang, Likai;Yin, Zhijun;Wang, Wei
    • Journal of Information Processing Systems
    • /
    • 제15권4호
    • /
    • pp.724-736
    • /
    • 2019
  • Dynamic thermal rating technology can effectively improve the thermal load capacity of transmission lines. However, its availability is limited by the quantity and high cost of the hardware facilities. This paper proposes a new dynamic thermal rating technology based on global/regional assimilation and prediction system (GRAPES) and geographic information system (GIS). The paper will also explore the method of obtaining any point meteorological data along the transmission line by using GRAPES and GIS, and provide the strategy of extracting and decoding meteorological data. In this paper, the accuracy of numerical weather prediction was verified from the perspective of time and space. Also, the 750-kV transmission line in Shaanxi Province is considered as an example to analyze. The results of the study indicate that dynamic thermal rating based on GRAPES and GIS can fully excavate the line power potential without additional cost on hardware, which saves a lot of investment.

재하된 H형강 휨재의 열응력해석을 이용한 한계온도 산정 (Calculation of Limit Temperature on H-Beam Flexural Member Through the Thermal Stress Analysis under the Lateral Load)

  • 윤성기;이치형;구본훈
    • 한국강구조학회 논문집
    • /
    • 제27권4호
    • /
    • pp.387-397
    • /
    • 2015
  • 국내의 내화성능평가는 대부분 사양적설계 방법인 품질시험을 통해 이뤄지고 있다. 하지만 시험 특성상 많은 비용과 시간을 요구하며 다양한 건축구조에 대한 내화성능평가에는 어려움이 많다. 따라서 본연구에서는 성능적 설계를 위한 연구로 유한요소 구조해석 프로그램인 ABAQUS를 사용해 H형강 휨재를 대상으로 변수에 따른 열응력 해석을 통해 내화성능을 검토하며, 하중비별 한계온도를 제안한다.

건물에너지 성능 분석을 위한 간이 건물에너지 시뮬레이션 프로그램 개발에 관한 연구 (Development of Simplified Building Energy Simulation Program for Building Energy Performance Analysis)

  • 박종일;강윤석;임병찬
    • 설비공학논문집
    • /
    • 제21권1호
    • /
    • pp.9-15
    • /
    • 2009
  • There are various types of energy simulation tool to predict both thermal load and energy use. However, the problem about these software is that they have too much input variables and need expert with skills to run the simulation. Therefore, the purpose of this study is to develop the thermal analysis simulation program with input variables which eliminates coordinates of building components instead of using full coordinates by using DOE2. Since the simulation engine of the program is DOE2, the validity of S-DOE is performed by comparing peak heating and cooling load results with VisualDOE and annual energy use results with actual energy use of 1996. The results have shown that there are little difference between VisualDOE and S-DOE. Also it showed that there are little difference between actual energy use and S-DOE energy use results. S-DOE took less time to model a building than VisualDOE. These results reveals that the application of S-DOE have potentials in accurately predicting both energy load and energy use of the building and still have an advantage of taking less time to model a building.

복토 주택의 복토 방법에 따른 열부하의 변화에 관한 연구 (A Study on the Variation of the Thermal Load for a House According to the Earth Sheltering Method)

  • 이재혁;최원기;서승직;조동우
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.166-171
    • /
    • 2008
  • We cannot imagine any more the environment and energy problems are separated from our lives. The various attempts to solve these problems are made all over the world. In this study it was performed to analyze a different heating and cooling load depending on the earth-sheltering method and kind of soils by using TRNSYS 16 as the first step to establish the design guidelines for earth-sheltered architecture, one of the eco-friendly and low energy consuming building types. After performing this simulation, we found the result like this. It is the most lowest load in case of all of walls and roof being earth-sheltered. But considering of the load reduction rate, the effect of earth-sheltering the exterior vertical wall is more efficient for load reduction than the one of earth-sheltering a roof. And we got a lower thermal load in case of a lower heat conductivity of soil. Afterwards we will conduct a further study for boundary condition at earth-sheltered surface and the simulation analysis about the sensitivity variables. The final goal of this study is preparing the design guidelines for earth-sheltered architecture. so we will contribute to building energy saving.

  • PDF

주거용 건물의 개별 환기시스템 필요성에 관한 연구 (The Individual Heat-recovery ventilation system of Residential Buildings)

  • 신우철;이왕제;윤종호;백남춘
    • KIEAE Journal
    • /
    • 제14권6호
    • /
    • pp.99-104
    • /
    • 2014
  • Recently supply of low energy house is increasing which can enhance energy efficiency and indoor environment comfort. Low energy house have to secure air tightness as well as thermal performance so house become high airtightness and inevitably need heat recovery ventilator to enhance indoor air quality. However, most of current ventilation systems are one-click, controlling the entire space so it causes increasing of heating load and fan power which makes it hard to save energy. Thus, Individual Control system is required which can achieve both enhancing indoor air quality and decreasing heating load and electric fan power. Thereby, in this study, we analyzed the correlation between ventilation and fan power through mock-up experiment and measured ventilation load under individual control system. As a result, under the condition of $24^{\circ}C$ of indoor temperature for 6 month(November to April) in Daejeon, ventilation load by fan speed was $10.9{\sim}19.6kWh/m^2{\cdot}a$ when operated 24 hours and $7.6{\sim}13.7kWh/m^2{\cdot}a$ when operated 12 hours in night time. In addition, it is possible to reduce at most 60% of ventilation load under the individual control system; measured ventilation load was $7.4kWh/m^2{\cdot}a$ when operated 24 hours, and $5.5kWh/m^2{\cdot}$ when operated 12 hours in night time.

EVALUATION OF THE FINITE ELEMENT MODELING OF A SPOT WELDED REGION FOR CRASH ANALYSIS

  • Song, J.H.;Huh, H.;Kim, H.G.;Park, S.H.
    • International Journal of Automotive Technology
    • /
    • 제7권3호
    • /
    • pp.329-336
    • /
    • 2006
  • The resistance spot-welded region in most current finite element crash models is characterized as a rigid beam at the location of the welded spot. The region is modeled to fail with a failure criterion which is a function of the axial and shear load at the rigid beam. The calculation of the load acting on the rigid beam is important to evaluate the failure of the spot-weld. In this paper, numerical simulation is carried out to evaluate the calculation of the load at the rigid beam. At first, the load on the spot-welded region is calculated with the precise finite element model considering the residual stress due to the thermal history during the spot welding procedure. And then, the load is compared with the one obtained from the model used in the crash analysis with respect to the element size, the element shape and the number of imposed constraints. Analysis results demonstrate that the load acting on the spot-welded element is correctly calculated by the change of the element shape around the welded region and the location of welded constrains. The results provide a guideline for an accurate finite element modeling of the spot-welded region in the crash analysis of vehicles.

100 마력급 고온초전도 전동기의 열적설계에 관한 연구 (A Study on the Thermal Design of the 100 hp High Temperature Superconductin)

  • 서무교;조영식;손명환;김석환;백승규;권영길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.732-734
    • /
    • 2002
  • The rotor thermal analysis consists of determining the heat load to the rotor, sizing the cryogenic system, and ensuring that the HTS rotor will operate at the design goal of 30 K. The heat load to the rotor is due to heat conduction through the torque tubes, current leads, instrumentation. and radiation from the thermal shield and the end caps. Coil operating temperature is determined from the coil losses and the heat transport to the coolant. An FEM thermal conductivity model is developed to allow calculation of heat transport in HTS field coil according to the heat exchanger shape and coolant feeding method. The losses determine the size of the cryocooler.

  • PDF