• 제목/요약/키워드: Thermal-infrared camera

검색결과 231건 처리시간 0.026초

열차 제어의 연속 제동시 마찰특성과 온도분포 (The Friction Characteristic and Distribution of Temperature in The Continuous Braking Effort on The Train Control)

  • 최경진;이시우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.55-58
    • /
    • 2005
  • During braking at a train, thermal energy is generated due to the frictions between disk and lining and wheel and shoe. In general, the braking transfers the kinetic energy into thermal energy. Therefore, the frictional characteristics are varied according to the braking force, the thermal resistance, and the thermostable, etc. Using a Dynamo testing we have studied the frictional characteristics and the thermal distribution to investigate a stable speed and to improve the testing method through comparing and analysing in the measurement of the thermocouple temperature and infrared camera.

  • PDF

풍력발전용 복합소재 블레이드의 적외선 열화상 검사를 이용한 신뢰성 검증 (A Study on Reliability Validation by Infrared Thermography of Composite Material Blade for Wind Turbine Generator)

  • 강병권;남문호;임익성
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제14권3호
    • /
    • pp.176-181
    • /
    • 2014
  • In these days, new and renewable energy is getting popular around globe and wind power generator is one of the renewable energy. In this study, we conducted a study on defect detection of composite material blade for wind power generator by applying active infrared thermography and produced a defect test piece by applying composite material used for blade of wind power generator. An infrared thermal camera and 2 kW halogen lamp are used for the purpose of research as equipments. Also, we analyzed temperature characteristic by using infrared thermal camera after checking a heat source on a test piece and found effectiveness of infrared thermography to blade of wind power generator by detecting defects resulting from temperature difference of a test piece, which eventually improve the safety and reliability of the composite material blade.

재난 감시를 위한 적외선 열화상 처리 시스템의 구현 (Implementation of Infrared Thermal Image Processing System for Disaster Monitoring)

  • 김원호;김동근
    • 융합신호처리학회논문지
    • /
    • 제11권1호
    • /
    • pp.9-12
    • /
    • 2010
  • 본 논문은 재난 감시를 위한 디지털 미디어 프로세서 기반의 적외선 열화상 처리 시스템의 설계 및 구현에 대하여 기술한다. 디지털 열화상 처리 보드는 DM642 디지털 미디어 프로세서와 비디오 인코더, 비디오 디코더 상용 칩을 기반으로 설계하고 구현하였다. 또한, 재난 감시 기능은 적외선 열화상의 온도분포를 분석하고 화재발생과 같은 재난상황을 감시하는 알고리즘을 구현하였으며, 적외선 열화상 입력은 $320\;{\times}\;240\;{\mu}$-bolometer 타입의 적외선 열화상 카메라를 사용하였다. 구현된 시제품의 시험 평가 결과, 10 프레임/초의 처리 속도로 요구되는 적외선 열화상 분석과 화재 검출 기능이 잘 동작 하였으며 구현 시스템의 실용성을 확인하였다.

Temperature Measurement of Photovoltaic Modules Using Non-Contact Infrared System

  • Jovanovic, Ugljesa;Mancic, Dragan;Jovanovic, Igor;Petrusic, Zoran
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.904-910
    • /
    • 2017
  • This paper presents temperature measurement of solar photovoltaic modules using the custom-made system composed of an infrared temperature sensor and a microcontroller. The obtained measurement results are processed, displayed and stored on a PC using the custom-made virtual instrument. The proposed system overcomes some of the problems related to the contact sensor application, and at the same time offers accurate readings and better flexibility. The proposed system is especially suitable for applications where the cost is a limiting factor in the choice of measuring system. The conducted analysis and the obtained results have shown an excellent accuracy of the proposed system in comparison to a high quality thermal imaging camera used as the reference instrument.

열전달 시뮬레이션을 통한 최적공극탐지 차트개발 (Development of an Optimum Void Detection Chart using Heat Transfer Simulation)

  • 최현호;박진형;지광습
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.241-244
    • /
    • 2006
  • It is essential to develop a large capacity, non-contact nondestructive inspection system having high reliability to investigate repaired and strengthened structures. Nowadays, an infrared camera is widely used in non-contact nondestructive inspection system. Because an infrared camera is sensitive to the surrounding environment, it is necessary to improve a sensitivity of thermal image information and a relationship between defects and thermal image information. In this papaer, presented is an optimum void detection chart for the optimum conditions to detect infrared rays from inside and outside defects like voids and cracks in concrete structures using extensive computer simulation. Sensitivity studies are performed with respect to variables influencing the temperature distribution such as heating temperature, heating time, and geometries of defect, etc. It may be stated that it could be successfully utilized for the non-contact nondestructive inspection system to detect defects in concrete structures.

  • PDF

기-액 기둥에서 기포유동에 관한 연구 (A Study on the Bubble Flow in the Gas-Liquid Plume)

  • 서동표;홍명석;오율권
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.2105-2108
    • /
    • 2003
  • The characteristics of upward bubble flow were experimentally investigated in a liquid bath. In the present study, a thermal-infrared camera and high speed CCO camera were used to measure their temperature and local rising velocity, respectively. Heat transfer from bubble surface to water is largely completed within z=10mm from the nozzle, and then the temperature of bubble surface reaches that of water rapidly. The rising velocity of bubble was calculated for two different experimental conditions: 1) bubble flow without kinetic energy 2) with kinetic energy. Bubble flow without kinetic energy starts to undergo the effect of inertia force 10cm away from the nozzle. Whereas, kinetic energy is dominant before 30 cm away from the nozzle in bubble flow, but after this point, kinetic energy and inertial force are applied on bubble flow at the same time.

  • PDF

드론 열화상활용 저수지 제체 누수탐사 (Drone Infrared Thermography Method for Leakage Inspection of Reservoir Embankment)

  • 이준구;유영철;김영화;최원;김한중
    • 한국농공학회논문집
    • /
    • 제60권6호
    • /
    • pp.21-31
    • /
    • 2018
  • The result of examination of diagnostic method, which is composed of a combination of a thermal camera and a drone that visually shows the temperature of the object by detecting the infrared rays, for detecting the leakage of earth dam was driven in this research. The drone infrared thermography method was suggested to precise safety diagnosis through direct comparing the two method results of electrical resistivity survey and thermal image survey. The important advantage of the thermal leakage detection method was the simplicity of the application, the quickness of the results, and the effectiveness of the work in combination with the existing diagnosis method.

적외선 카메라-레이저 공통광학계의 레이저빔 열 영향성 분석 (Analysis of Laser-beam Thermal Effects In an Infrared Camera and Laser Common-path Optical System)

  • 김성재
    • 한국광학회지
    • /
    • 제28권4호
    • /
    • pp.153-157
    • /
    • 2017
  • 지향성적외선방해장비의 정렬 정밀도를 높히고 중량을 감소시키기 위해 적용된 적외선 카메라-레이저 공통광학계 구조에서 영상 성능 저하를 야기시키는 레이저빔 열 영향성을 분석하였다. 높은 에너지 밀도를 가지는 레이저빔이 광부품에 흡수되면 열이 발생하고 온도가 상승한다. 공통광학계 광부품 표면에서 발생한 열은 시스템 투과율을 감소시켜 적외선 카메라의 영상 품질을 저하시킬 수 있다. 지향성적외선방해장비의 운용개념을 고려하여 파장 $4{\mu}m$, 출력 3 W의 레이저빔이 10초간 미러(알루미늄, 실리카 글래스, 실리콘) 및 렌즈(사파이어, 셀레늄화아연, 실리콘, 게르마늄) 재료에 조사되는 상황을 가정하여 온도 분포를 계산하였다. 계산 결과, 미러 재료로는 실리카 글래스, 렌즈 재료로는 사파이어의 온도 상승이 상대적으로 컸고, 재료 온도 분포에 가장 큰 영향을 미치는 요소는 재료의 레이저빔 흡수율과 열전도도임을 확인하였다. 결론적으로 적외선 카메라-레이저 공통광학계에 사용하는 광부품은 흡수율이 낮고 열전도도가 높은 특성을 갖도록 선정되어야 광부품 온도 상승에 의한 적외선 카메라의 영상 품질 저하를 방지할 수 있다.

화재 특성 고찰을 통한 농연 극복 센서 모듈 (A Sensor Module Overcoming Thick Smoke through Investigation of Fire Characteristics)

  • 조민영;신동인;전세웅
    • 로봇학회논문지
    • /
    • 제13권4호
    • /
    • pp.237-247
    • /
    • 2018
  • In this paper, we describe a sensor module that monitors fire environment by analyzing fire characteristics. We analyzed the smoke characteristics of indoor fire. Six different environments were defined according to the type of smoke and the flame, and the sensors available for each environment were combined. Based on this analysis, the sensors were selected from the perspective of firefighter. The sensor module consists of an RGB camera, an infrared camera and a radar. It is designed with minimum weight to fit on the robot. the enclosure of sensor is designed to protect against the radiant heat of the fire scene. We propose a single camera mode, thermal stereo mode, data fusion mode, and radar mode that can be used depending on the fire scene. Thermal stereo was effectively refined using an image segmentation algorithm, SLIC (Simple Linear Iterative Clustering). In order to reproduce the fire scene, three fire test environments were built and each sensor was verified.

몰드성형 광학렌즈를 이용한 의료기기용 열화상카메라 체열진단의 적용도 평가 (Evaluation of Thermography Camera Using Molded Optical Lens for Medical Applications)

  • 유성미;김혜정
    • 한국전기전자재료학회논문지
    • /
    • 제26권8호
    • /
    • pp.624-628
    • /
    • 2013
  • With the recent development of less-costly uncooled detector technology, expensive optics are among the remaining significant cost drivers in the thermography camera. As a potential solution to this problem, the fabrication of IR lenses using chalcogenide glass has been studied in recent years. We report on the molding and evaluation of a ultra-precision chalcogenide-glass lens for the thermography camera for body-temperature monitoring. In addition, we fabricated prototype thermography camera using the chalcogenide-glass lens and obtained the thermal image from the camera. In this work, it was found out that thermography camera discerned body-temperature between 20 and $50^{\circ}C$ through the analysis of thermal image. It is confirmed that thermography camera using the chalcogenide-glass lens is applicable to the body-temperature monitoring system.